Página 1 dos resultados de 887 itens digitais encontrados em 0.002 segundos

Effect of different polishing systems on the surface roughness of microhybrid composites

SCHEIBE, Kristine Guará Brusaca Almeida; ALMEIDA, Karoline Guará Brusaca; MEDEIROS, Igor Studart; COSTA, José Ferreira; ALVES, Cláudia Maria Coêlho
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
37.44783%
The use of composite resins in dentistry is well accepted for restoring anterior and posterior teeth. Many polishing protocols have been evaluated for their effect on the surface roughness of restorative materials. This study compared the effect of different polishing systems on the surface roughness of microhybrid composites. Thirty-six specimens were prepared for each composite $#91;Charisma® (Heraeus Kulzer), Fill Magic® (Vigodent), TPH Spectrum® (Dentsply), Z100® (3M/ESPE) and Z250® (3M/ESPE)] and submitted to surface treatment with Enhance® and PoGo® (Dentsply) points, sequential Sof-Lex XT® aluminum oxide disks (3M/ESPE), and felt disks (TDV) combined with Excel® diamond polishing paste (TDV). Average surface roughness (Ra) was measured with a mechanical roughness tester. The data were analyzed by two-way ANOVA with repetition of the factorial design and the Tukey-Kramer test (p<0.01). The F-test result for treatments and resins was high (p<0.0001 for both), indicating that the effect of the treatment applied to the specimen surface and the effect of the type of resin on surface roughness was highly significant. Regarding the interaction between polishing system and type of resin used, a p value of 0.0002 was obtained...

Influência do acabamento e polimento de resina composta na resistência adesiva à dentina e no ângulo cavo-superficial em esmalte; The influence of finishing and polishing procedures on dentin bond strength of resin composite and at the interface enamel/restoration

Regalado, Diego Ferreira
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 17/08/2007 PT
Relevância na Pesquisa
37.530107%
O objetivo desse trabalho foi verificar a influência do procedimento de acabamento e polimento das restaurações de resina composta na resistência adesiva à dentina, através de testes de microtração, assim como, analisar em microscopia eletrônica de varredura a interface dente/restauração no nível do ângulo cavo-superficial. Terceiros molares humanos extraídos e hígidos foram utilizados nesse estudo, após aprovação pelo Comitê de Ética em Pesquisa da FOB-USP. Os dentes foram restaurados com sistema adesivo Solobond M (VOCO) e resina composta Grandio (VOCO) e distribuídos nos seguintes grupos: G1 (controle) - sem acabamento e polimento, G2 - acabamento e polimento imediato, G3 - sem acabamento e polimento e armazenado por sete dias e G4 - acabamento e polimento após sete diasem estufa a 37ºC. Palitos com dimensões de 1mm x 1mm foram obtidos e submetidos a uma força de tração em uma máquina de ensaios universal EMIC à velocidade de 0.5mm/min. Para a análise em microscopia eletrônica de varredura, 20 terceiros molares receberam quatro preparos cavitários com 1mm de diâmetro e 3mm de altura que foram restaurados com o mesmo sistema restaurador utilizado para os testes de resistência adesiva e distribuídos nos mesmos grupos descritos acima. Após a obtenção dos espécimes de cada grupo...

Polimento de rochas ornamentais: um enfoque tribológico ao processo; Dimension stones polishing: a tribological approach

Silveira, Leonardo Luiz Lyrio da
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 02/08/2007 PT
Relevância na Pesquisa
37.44783%
Este trabalho apresenta uma contribuição experimental cujo objetivo é fornecer elementos para o aprimoramento tecnológico das etapas de polimento de rochas ornamentais. Alguns aspectos da tribologia, ramo do conhecimento amplamente utilizado nas engenharias mecânica e de materiais, foram transferidos para o estudo do polimento de rochas ornamentais e subsidiaram a investigação da interação do tribossistema composto pela rocha, pelo abrasivo e por condições operacionais. Foi desenvolvido um equipamento em laboratório que possibilitou a simulação do processo de polimento, em diversas condições operacionais, considerando as variáveis tempo, velocidade de rotação e intensidade das cargas aplicadas. Foram comparados polimentos, em condições industrial e laboratorial de rochas graníticas, visando estabelecer as influências das suas características composicionais, texturais e estruturais no processo. Os resultados permitiram definir as condições ideais para a obtenção de melhor qualidade no brilho das rochas e representa uma contribuição tanto para o entendimento do processo de polimento propriamente dito como também para a otimização do processo industrial.; This work shows an experimental contribution which goal is to provide elements to the technological improvement of each step of dimension stones polishing. Some aspects of tribology...

Polishing for glass ceramics: Which protocol?

Silva, Tania Mara da; Rodrigues Danzi Salvia, Ana Carolina; Carvalho, Rodrigo Furtado de; Pagani, Clovis; Rocha, Daniel Maranha da; Silva, Eduardo Galera da
Fonte: Elsevier B.V. Publicador: Elsevier B.V.
Tipo: Artigo de Revista Científica Formato: 160-170
ENG
Relevância na Pesquisa
37.530107%
Purpose: The execution of adjustments on ceramic restorations is sometimes necessary for either correction of occlusion and/or inadequate contours or esthetical improvements. Clinically, the surfaces undergo weariness through fine grinding diamond burs which remove the superficial glazing layer. Several materials for ceramic polishing have been used in an attempt to reach a satisfactory surface smoothness. The aim of this study was to perform a literature review on different polishing protocols of several dental ceramics. Study selection: This is a literature review performed through scientific articles published between 2004 and 2012, indexed in MEDLINE, PubMed and Scielo databases. The study selected and analyzed a total of 20 relevant articles that evaluated different types of ceramics, polishing treatment and surface roughness.Results: After an extensive literature review, this study observed: 1 - after the rupture of the glazing layer due to the adjustments of the restorations, the best choice for the polishing of the surface will depend on the type of ceramics used; 2 - glazing procedure provide excellent results regarding to the superficial smoothness; however, if reglazing is impossible, either abrasive rubber cups/points or sandpaper discs followed by the use of diamond polishing pastes results in a satisfactory superficial smoothness; 3 - clinical studies that take into account the behavior of the protocols polishing are scarce and should be encouraged; 4 - the large number of variables influence the final outcome of polishing should be considered. Conclusions: The necessity in standardization of methodologies to enable a comparison among researches. (c) 2014 Japan Prosthodontic Society. Published by Elsevier Ireland. All rights reserved.

Avaliação da rugosidade do esmalte dental apos microabrasão e polimento e da microdureza superficial apos microabrasão, polimento e armazenamento em saliva artificial; Evaluation of the enamel roughness after microabrasion and polishing and the superficial microhardness after microabrasion, polishing and storage in artificial saliva

Larissa Silveira de Mendonça Fragoso
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 09/02/2010 PT
Relevância na Pesquisa
37.68824%
Os objetivos deste estudo "in vitro" foram: 1) avaliar o efeito da microabrasão sobre a microdureza e a rugosidade do esmalte dental bovino, bem como a ação do polimento realizado com pastas apropriadas no esmalte abrasionado; 2) avaliar o armazenamento em saliva artificial, em diferentes tempos de ação sobre a microdureza do esmalte dental bovino. Para isso, foram utilizados 144 blocos de esmalte bovino (6,0mm x 6,0mm) que constituíram os grupos: I- tratamento com ácido fosfórico a 37% e pedra pomes (n=48), II- tratamento com Opalustre (Ultradent) (n=48), III- tratamento com Whiteness RM (FGM) (n=48). Os três grupos foram divididos em três subgrupos, de acordo com os seguintes tratamentos: a) polimento com pasta diamantada; b) polimento com pasta profilática fluoretada e c) sem polimento (controle). Foram realizados ensaios de microdureza nos seguintes tempos estabelecidos: 1) inicial (antes da realização da microabrasão e polimento); 2) após a realização da microabrasão com e sem polimento; 3) após a realização da microabrasão com e sem polimento e imersão em saliva artificial por períodos de 24 horas; 4) após a realização da microabrasão com e sem polimento e imersão em saliva artificial por 7 dias. Foram realizados ensaios de rugosidade nos seguintes tempos pré-estabelecidos: 1) inicial (antes da realização da microabrasão e polimento) e final (após a realização da microabrasão com e sem polimento (controle). Os dados obtidos foram submetidos à análise estatística ANOVA "dois fatores"...

Alterações nas caracteristicas da superficie de compositos restauradores sumetidas a diferentes tecnicas de acabamento e polimento; Changes in surface characteristics of restorative composites subjected to different techniques for finishing and polishing

Vera Lucia Schmitt
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 22/04/2010 PT
Relevância na Pesquisa
37.530107%
Inúmeras alterações foram feitas na fabricação das resinas compostas fotoativáveis, especialmente na tentativa de obter melhor estabilidade de cor, adequada resistência ao desgaste e lisura de superfície clinicamente aceitável. Neste contexto, fabricantes têm, promovido alterações no tamanho das partículas de carga e incorporado a maior quantidade de componentes inorgânicos no interior da matriz resinosa. Além da composição do material, os procedimentos de acabamento e polimento podem também influenciar na qualidade superficial da resina composta, relacionando-se diretamente com rugosidade. Superfícies rugosas predispõem a restauração a maior retenção de biofilme bacteriano, facilitando o desenvolvimento de lesões cariosas, manchamentos além de interferir no seu brilho e estética finais. Neste contexto, esta tese propôs a avaliar qualitativamente a topografia de superfície de resinas compostas microhíbridas e nanoparticuladas, em função de diferentes combinações entre técnicas de polimento e resinas compostas. Com objetivo didático, esta tese foi dividida em 3 partes, como descrito a seguir. Parte 1: avaliar a influência que diferentes técnicas de acabamento e polimento exercem sobre a rugosidade da superfície de uma resina composta nanoparticulada. Parte 2: comparar a estabilidade de cor e a característica de superfície promovida por técnicas de acabamento e polimento que empregam um ou múltiplos passos sobre resinas microhíbridas e nanoparticuladas...

Avaliação do brilho, rugosidade e integridade da superfície de cerâmicas odontológicas após o polimento, abrasão por escovação e repolimento das superfícies; Evaluation of surface gloss, roughness and integrity of dental ceramics after polishing, mechanical toothbrushing and repolishing

Wagner José Silva Ursi
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 03/02/2011 PT
Relevância na Pesquisa
37.49344%
O objetivo neste estudo foi avaliar a influência de sistemas de polimento, da escovação mecânica e do repolimento sobre o brilho, rugosidade e morfologia da superfície de materiais cerâmicos. Três cerâmicas foram avaliadas: IPS Eris (Ivoclar Vivadent), Vita VM7 (VITA Zahnfabrik) e Cercon CS (Degudent). Trinta amostras cilíndricas padronizadas de cada material foram confeccionadas e aleatoriamente divididas em 3 grupos (n=10) sendo que cada grupo foi submetido a um dos três procedimentos de polimento (taça de borracha; disco de feltro+pasta diamantada; taça de borracha + disco de feltro + pasta diamantada). Após o polimento, o brilho da superfície polida foi mensurado com medidor de brilho (ZGM 1120 Glossmeter – Zehntner) e a rugosidade avaliada através de rugosímetro (Surfcorder SE1700 – Kosaka Lab.). As amostras foram submetidas a 30.000 ciclos mecânicos de escovação, utilizando solução de dentifrício e água deionizada. Após a escovação, as mensurações de brilho e rugosidade foram repetidas. Em seguida, as amostras foram submetidas novamente aos procedimentos de polimento, e o brilho e a rugosidade avaliados novamente. Inicialmente foi realizada análise exploratória dos dados pelo aplicativo GUIDED DATA ANALYSIS do SAS (SAS...

Effects of polishing procedures on color stability of composite resins

Güler,Ahmet Umut; Güler,Eda; Yücel,Ali Çağin; Ertaş,Ertan
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/04/2009 EN
Relevância na Pesquisa
37.625137%
The purpose of this study was to investigate the effect of different polishing methods on color stability of posterior, universal and nanohybrid composite resin restorative materials upon exposure to a staining agent. Twenty-five specimens were prepared for each of 5 different composite resins (Filtek Z250, Filtek P60, Quadrant LC, Grandio and Filtek Supreme). Specimens were divided into 5 groups and different polishing procedures, including polishing discs (Pd), polishing discs then diamond polishing paste (PdP), polishing discs then a liquid polishing system (Biscover) (PdB), and combinations of these (PdPB) were used. Unpolished specimens served as the control (C). The specimens were stored for 48 h in a coffee solution. The color of all specimens was measured before and after exposure with a colorimeter, and total color change (DE*) were calculated. The data were analyzed with a two-way ANOVA and the means were compared by Tukey HSD test (a=0.05). The lowest color difference was observed in the groups PdP and C, while the highest color difference was observed in PdPB, and PdB. When comparing the five different restorative materials, no significant difference was observed between FiltekP60 and FiltekZ250, and these materials demonstrated significantly less color change than Quadrant LC and the nanohybrid materials (Grandio...

Effects of different polishing techniques on the surface roughness of dental porcelains

Sarikaya,Işil; Güler,Ahmet Umut
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/02/2010 EN
Relevância na Pesquisa
37.625137%
OBJECTIVE: The purpose of this study was to evaluate the effects of different polishing techniques on the surface roughness of dental porcelains. MATERIAL AND METHODS: Fifty-five cylindirical specimens (15x2 mm) were prepared for each feldspathic (Vita VMK 95, Ceramco III) and low-fusing dental porcelain (Matchmaker). Fifty-five specimens of machinable feldspathic porcelain blocks (Vitablocs Mark II), (12x14x18 mm) were cut into 2-mm-thick slices (12x14 mm) with low speed saw. The prepared specimens were divided into 11 groups (n=5) representing different polishing techniques including control ((C) no surface treatment), glaze (G) and other 9 groups that were finished and polished with polishing discs (Sof-Lex) (Sl), two porcelain polishing kits (NTI (Pk), Dialite II (Di)), a diamond polishing paste (Sparkle) (Sp), a zirconium silicate based cleaning and polishing prophy paste (Zircate) (Zr), an aluminum oxide polishing paste (Prisma Gloss) (Pg), and combinations of them. The surface roughness of all groups was measured with a profilometer. The data were analyzed with a 2-way analysis of variance, and the mean values were compared by the Tukey Honestly Significant Difference test (a=0.05). RESULTS: For all porcelain material groups...

Effects of air-polishing powders on color stability of composite resins

Güler,Ahmet Umut; Duran,Ibrahim; Yücel,Ali Çağin; Özkan,Pelin
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/10/2011 EN
Relevância na Pesquisa
37.530107%
OBJECTIVES: The purpose of this study was to investigate the effect of different air-polishing powders on the color stability of different types of composite resin restorative materials. MATERIAL AND METHODS: Thirty cylindrical specimens (15×2 mm) were prepared for each of 7 composite resin restorative materials. All specimens were polished with a series of aluminum oxide polishing discs (Sof-Lex). The prepared specimens of each composite resin were randomly divided into 3 groups of 10 specimens each, for control (Group-C) and two air-powder applications (Group-CP: Cavitron Prophy-Jet; Group-PS: Sirona ProSmile prophylaxis powder). A standard air-polishing unit (ProSmile Handly) was used. All specimens were air-powdered for 10 s at 4-bar pressure. The distance of the spray nosel from the specimens was approximately 10 mm and angulation of the nosel was 90°. Specimens were stored in 100 mL of coffee (Nescafe Classic) for 24 h at 37°C. Color measurement of all specimens was recorded before and after exposure to staining agent with a colorimeter (Minolta CR-300). Color differences (∆E*) between the 2 color measurements (baseline and after 24 h storage) were calculated. The data were analyzed with a 2-way ANOVA test, and mean values were compared by the Tukey HSD test (p<0.05). RESULTS: According to the 2-way ANOVA results...

"Análise 'in vitro'da rugosidade superficial apresentada pelas porcelanas omega 900 e vitadur alpha após a utilização de três diferentes sistemas de polimento" ; Omega 900 e vitadur alpha ceramics using three different polishing systems

Araujo, Jesuina Lamartine Nogueira
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 25/06/2003 PT
Relevância na Pesquisa
37.56023%
RESUMO A qualidade da superfície de trabalhos cerâmicos que requer ajuste durante a sua adaptação ao remanescente dentário desperta a atenção durante os procedimentos odontológicos restauradores estéticos. Observa-se a necessidade freqüente de realizar desgastes superficiais nas restaurações cerâmicas, sendo que a preservação de uma superfície lisa é importante para as propriedades destes materiais, bem como para o seu comportamento clínico. Este trabalho propõe-se a avaliar a técnica com maior capacidade de polimento da superfície cerâmica asperizada, através da medição com ponta apalpadora de um rugosímetro, e utilizando o MEV para observações visuais com relação às técnicas empregadas. Para tal 80 corpos-de-prova foram confeccionados utilizando-se as porcelanas Omega 900 e Vitadur Alpha, constituindo quatro grupos experimentais: A – glaze (controle); B – polimento com borrachas abrasivas da DFL mais pasta para polimento da KOTA; C – polimento com borrachas abrasivas mais rodas de feltro mais pasta para polimento Porcelize (Cosmedent); D – polimento com borrachas abrasivas mais pasta porcelize mais discos Flexibuff mais pasta diamantada para brilho Enamelize (Cosmedent). Os dados receberam tratamento estatístico por meio da Análise de variância (ANOVA) e teste de Tukey...

Polishing methods of an alumina-reinforced feldspar ceramic

Bottino,Marco Cícero; Valandro,Luiz Felipe; Kantorski,Karla Zanini; Bressiani,José Carlos; Bottino,Marco Antonio
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2006 EN
Relevância na Pesquisa
37.49344%
The purpose of this study was to test the hypothesis that mechanical polishing methods of ceramic surfaces allow similar superficial roughness to that of glazed surfaces. Twenty-five Vitadur Alpha ceramic discs (5 mm x 2 mm) were prepared according to the manufacturer's specifications. All specimens were glazed and randomly assigned to 5 groups (n=5), according to finishing and polishing protocols: G1: glazed (control); G2: diamond bur finishing; G3: G2 + silicon rubber tip polishing; G4: G3 + felt disc/diamond polishing paste; G5: G3 + felt disc impregnated with fine-particle diamond paste. Next, surface roughness means (Ra - µm) were calculated. Qualitative analysis was made by scanning electron microscopy. Surface roughness data were submitted to ANOVA and Tukey's test at 5% significance level. G1 and G4 were statistically similar (p>0.05). G2 presented the highest roughness means (p<0.05) followed by groups G3, G5, G4 and G1 in a decreasing order. The hypothesis was partially confirmed as only the mechanical polishing (G4) produced similar superficial roughness to that of surface glazing, although finishing and polishing are technically critical procedures.

Surface roughness of a dental ceramic after polishing with different vehicles and diamond pastes

Camacho,Guilherme Brião; Vinha,Dionísio; Panzeri,Heitor; Nonaka,Tomio; Gonçalves,Mariane
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2006 EN
Relevância na Pesquisa
37.56023%
During fabrication of bonded ceramic restorations, cervical adaptation, occlusal adjustment and final finishing/polishing are procedures to be performed at the dental office after adhesive cementation. Final adjustments may result in loss of ceramic glaze, which requires new polishing of the ceramic surface, with special attention for selection of adequate materials and instruments. The purpose of this study was to evaluate the efficiency of different vehicles associated with diamond pastes indicated for dental ceramic polishing. Two polishing pastes (Crystar Paste and Diamond Excell) associated with four vehicles (rubber cup, Robinson bristle brush, felt wheel and buff disc) were evaluated. Disc-shaped specimens were fabricated from Ceramco II dental ceramic. Surface roughness means (Ra) of the ceramic specimens were determined with a rugosimeter. Data were analyzed statistically by two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant difference (p>0.01) between the polishing pastes. However, there were statistically significant differences (p<0.01) among the tested vehicles. Vehicle-paste interaction showed statistically significant difference (p<0.05) as well. It may be concluded that: 1) Robinson bristle brush...

Adaptation of complete denture bases submitted to chemical polishing

Gomes,Márcia; Broilo,Josué Ricardo; Walber,Luiz Fernando; Maccari,Paulo César Armani; Shinkai,Rosemary Sadami Arai
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2004 EN
Relevância na Pesquisa
37.58541%
OBJECTIVE: This study evaluated the effect of chemical polishing on the internal adaptation of complete denture bases fabricated with Veracril® resin and polymerized by either the conventional (C) or microwave (M) techniques. MATERIAL AND METHODS: Six groups (n=6/group) were tested: 1) C + no polishing (CO); 2) C + chemical polishing (CQ); 3) C + immersion in hot water at 75ºC (CW); 4) M + no polishing (MO); 5) M + chemical polishing (MQ); and 6) M + immersion in hot water at 75ºC (MW). Internal adaptation immediately after the polishing treatment and after 30 days of storage in water at 37ºC was evaluated by weighing a vinyl polysiloxane film reproducing the gap between resin base and metallic master model, using a precision scale. Data were analyzed by ANOVA and Tukey test and paired Student's t test, at a significance level of 0.05. RESULTS: No significant difference in immediate adaptation was found as a function of technique, polishing treatment, or interaction of technique/polishing. After 30 days, adaptation means (g) were: CO=2.46±0.32 a; CQ=3.40±0.23 d; CW=3.14±0.22 c; MO=3.23±0.37 c, d; MQ=3.41±0.47 d; MW=2.81±0.33 b (means followed by different letters are statistically different at alpha=0.05). All groups but group CO had significant increase of misfit over the tested period. CONCLUSION: The present results suggest that Veracril® resin denture bases submitted to chemical polishing had decrease of internal adaptation in 30 days...

Effect of finishing and polishing on surface roughness of composite resins after bleaching

Bittencourt,Bruna Fortes; Gomes,Giovana Mongruel; Trentini,Felipe Auer; Azevedo,Mônica Regina de; Gomes,João Carlos; Gomes,Osnara Maria Mongruel
Fonte: Faculdade de Odontologia de Piracicaba - UNICAMP Publicador: Faculdade de Odontologia de Piracicaba - UNICAMP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2014 EN
Relevância na Pesquisa
37.49344%
AIM : To evaluate the influence of finishing and polishing techniques on the surface roughness of two composite resins (CRs) subjected to bleaching procedure. METHODS : Forty-eight CR specimens were divided into six groups (n=8). For G1 to G3, a microhybrid CR (Opallis; FGM) was used, and G4 to G6, received a nanohybrid CR (Brilliant NewLine; Coltène/Whaledent). All specimens were subjected to bleaching procedure with 35% hydrogen peroxide (two 45-min applications, with a 5-day interval). The surface roughness of all specimens was evaluated before and after the bleaching and/or finishing/polishing (Ra parameter) by a roughness meter. After bleaching, the groups were subjected to finishing and polishing procedures: G2 and G5 - felt discs + diamond pastes; and G3 and G6 - silicon rubber tips. The control groups (G1 and G4) had no finishing or polishing treatment after bleaching. Data were analyzed by ANOVA and Tukey's post-test, and t test for paired samples (a=0.05). RESULTS : bleaching treatment increased Ra values for the nanohybrid CR specimens, but both finishing/polishing techniques were able to reduce these values; for the microhybrid specimens, only finishing/polishing with silicon rubber tips decreased the roughness values. CONCLUSIONS : For both microhybrid and nanohybrid CRs...

Effect of different finishing and polishing techniques on the surface roughness of microfilled, hybrid and packable composite resins

Barbosa,Silvia Helena; Zanata,Régia Luzia; Navarro,Maria Fidela de Lima; Nunes,Osvaldo Benoni
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/04/2005 EN
Relevância na Pesquisa
37.56023%
This study examined the average surface roughness (Ra, µm) of 2 microfilled (Durafill and Perfection), 1 hybrid (Filtek Z250) and 2 packable composite resins (Surefil and Fill Magic), before (baseline) and after eight different finishing and polishing treatments. The surface roughness was assessed using a profilometer. Ten specimens of each composite resin were randomly subjected to one of the following finishing/polishing techniques: A - carbide burs; B - fine/extrafine diamond burs; C - Sof-Lex aluminum oxide discs; D - Super-Snap aluminum oxide discs; E - rubber polishing points + fine/extrafine polishing pastes; F - diamond burs + rubber polishing points + fine/extrafine polishing pastes; G - diamond burs + Sof-Lex system; H - diamond burs + Super-Snap system. Data were analyzed using two-way ANOVA and Tukey's HSD test. Significant differences (p<0.05) were detected among both the resins and the finishing/polishing techniques. For all resins, the use of diamond burs resulted in the greatest surface roughness (Ra: 0.69 to 1.44 µm). The lowest Ra means were obtained for the specimens treated with Sof-Lex discs (Ra: 0.11 to 0.25 µm). The Ra values of Durafill were lower than those of Perfection and Filtek Z250, and these in turn had lower Ra than the packable composite resins. Overall...

Adaptação de bases de próteses totais submetidas a polimento químico; Adaptation of complete denture bases submitted to chemical polishing

Gomes, Márcia; Broilo, Josué Ricardo; Walber, Luiz Fernando; Maccari, Paulo César Armani; Shinkai, Rosemary Sadami Arai
Fonte: Universidade de São Paulo. Faculdade de Odontologia de Bauru Publicador: Universidade de São Paulo. Faculdade de Odontologia de Bauru
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; Formato: application/pdf
Publicado em 01/12/2004 ENG
Relevância na Pesquisa
37.58541%
OBJETIVO: Este trabalho avaliou o efeito do polimento químico sobre a adaptação interna de bases de próteses totais confeccionadas em resina acrílica ativada termicamente Veracril® polimerizada por técnica convencional (C) ou por microondas (M). MATERIAIS E MÉTODOS: Foram testados seis grupos (n=6/grupo): 1) C + sem polimento (CO); 2) C + polimento químico (CQ); 3) C + banho de água a 75ºC (CW); 4) M + sem polimento (MO); 5) M + polimento químico (MQ); e 6) M + banho de água a 75ºC (MW). A adaptação interna foi avaliada por pesagem em balança analítica de precisão de uma película de silicona de adição interposta entre base de resina e modelo-mestre metálico. A adaptação foi medida imediatamente após o polimento e após 30 dias de armazenamento em água a 37ºC. Os dados foram analisados por ANOVA e teste de Tukey, e por teste t de Student pareado, ao nível de significância de 0,05. RESULTADOS: Não houve diferença significativa na adaptação imediata em função do tipo de polimerização, do polimento ou da interação polimerização/polimento. Após 30 dias, as médias de adaptação (g) foram: CO=2,46 0,32 a; CQ=3,40 ± 0,23 d; CW=3,14 ± 0,22 c; MO=3,23 ± 0,37 c, d; MQ=3...

Effects of different polishing techniques on the surface roughness of dental porcelains

Sarikaya, Işil; Güler, Ahmet Umut
Fonte: Universidade de São Paulo. Faculdade de Odontologia de Bauru Publicador: Universidade de São Paulo. Faculdade de Odontologia de Bauru
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; Formato: application/pdf
Publicado em 01/02/2010 ENG
Relevância na Pesquisa
37.530107%
OBJECTIVE: The purpose of this study was to evaluate the effects of different polishing techniques on the surface roughness of dental porcelains. MATERIAL AND METHODS: Fifty-five cylindirical specimens (15x2 mm) were prepared for each feldspathic (Vita VMK 95, Ceramco III) and low-fusing dental porcelain (Matchmaker). Fifty-five specimens of machinable feldspathic porcelain blocks (Vitablocs Mark II), (12x14x18 mm) were cut into 2-mm-thick slices (12x14 mm) with low speed saw. The prepared specimens were divided into 11 groups (n=5) representing different polishing techniques including control ((C) no surface treatment), glaze (G) and other 9 groups that were finished and polished with polishing discs (Sof-Lex) (Sl), two porcelain polishing kits (NTI (Pk), Dialite II (Di)), a diamond polishing paste (Sparkle) (Sp), a zirconium silicate based cleaning and polishing prophy paste (Zircate) (Zr), an aluminum oxide polishing paste (Prisma Gloss) (Pg), and combinations of them. The surface roughness of all groups was measured with a profilometer. The data were analyzed with a 2-way analysis of variance, and the mean values were compared by the Tukey Honestly Significant Difference test (a=0.05). RESULTS: For all porcelain material groups...

Effects of polishing procedures on color stability of composite resins

Güler, Ahmet Umut; Güler, Eda; Yücel, Ali Çağin; Ertaş, Ertan
Fonte: Universidade de São Paulo. Faculdade de Odontologia de Bauru Publicador: Universidade de São Paulo. Faculdade de Odontologia de Bauru
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; Formato: application/pdf
Publicado em 01/04/2009 ENG
Relevância na Pesquisa
37.625137%
The purpose of this study was to investigate the effect of different polishing methods on color stability of posterior, universal and nanohybrid composite resin restorative materials upon exposure to a staining agent. Twenty-five specimens were prepared for each of 5 different composite resins (Filtek Z250, Filtek P60, Quadrant LC, Grandio and Filtek Supreme). Specimens were divided into 5 groups and different polishing procedures, including polishing discs (Pd), polishing discs then diamond polishing paste (PdP), polishing discs then a liquid polishing system (Biscover) (PdB), and combinations of these (PdPB) were used. Unpolished specimens served as the control (C). The specimens were stored for 48 h in a coffee solution. The color of all specimens was measured before and after exposure with a colorimeter, and total color change (DE*) were calculated. The data were analyzed with a two-way ANOVA and the means were compared by Tukey HSD test (a=0.05). The lowest color difference was observed in the groups PdP and C, while the highest color difference was observed in PdPB, and PdB. When comparing the five different restorative materials, no significant difference was observed between FiltekP60 and FiltekZ250, and these materials demonstrated significantly less color change than Quadrant LC and the nanohybrid materials (Grandio...

Effect of finishing and polishing on surface roughness of composite resins after bleaching

Bittencourt, Bruna Fortes; Gomes, Giovana Mongruel; Trentini, Felipe Auer; Azevedo, Mônica Regina de; Gomes, João Carlos; Gomes, Osnara Maria Mongruel
Fonte: UNICAMP/FOP Publicador: UNICAMP/FOP
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ;
Publicado em 31/12/2009 POR
Relevância na Pesquisa
37.49344%
Aim: To evaluate the influence of finishing and polishing techniques on the surface roughness of two composite resins (CRs) subjected to bleaching procedure. Methods: Forty-eight CR specimens were divided into six groups (n=8). For G1 to G3, a microhybrid CR (Opallis; FGM) was used, and G4 to G6, received a nanohybrid CR (Brilliant NewLine; Coltène/Whaledent). All specimens were subjected to bleaching procedure with 35% hydrogen peroxide (two 45-min applications, with a 5-day interval). The surface roughness of all specimens was evaluated before and after the bleaching and/or finishing/polishing (Ra parameter) by a roughness meter. After bleaching, the groups were subjected to finishing and polishing procedures: G2 and G5 - felt discs + diamond pastes; and G3 and G6 - silicon rubber tips. The control groups (G1 and G4) had no finishing or polishing treatment after bleaching. Data were analyzed by ANOVA and Tukey’s posttest, and t test for paired samples (α=0.05). Results: bleaching treatment increased Ra values for the nanohybrid CR specimens, but both finishing/polishing techniques were able to reduce these values; for the microhybrid specimens, only finishing/polishing with silicon rubber tips decreased the roughness values. Conclusions: For both microhybrid and nanohybrid CRs...