Página 1 dos resultados de 149 itens digitais encontrados em 0.005 segundos

Sequential Injection Analysis (SIA) for Arsenic Speciation by Capillary Electrophoresis Hyphenated to Inductively Coupled Plasma Sector Field Mass Spectrometry (CE-ICP-SFMS)

SUAREZ, Carlos A.; ARAUJO, Georgia C. L.; GINE, Maria F.; KAKAZU, Mauricio H.; SARKIS, Jorge E. S.
Fonte: TAYLOR & FRANCIS INC Publicador: TAYLOR & FRANCIS INC
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
379.28117%
Sequential injection analysis (SIA) is proposed for managing microvolumes of sample and arsenic species solutions for speciation analysis by capillary electrophoresis focusing on the reduction of hazardous waste residues. An electronically controlled hydrodynamic injector was projected to introduce microvolumes of solutions prepared by SIA into the CE capillary with precision better than 2%. The determination of arsenite, arsenate, monomethylarsonic acid, dimethylarsinic acid, and arsenobetaine was performed from 50 mu L volumes of lyophilized urine and extract of shrimp with the system hyphenated to inductively coupled plasma mass spectrometry (CE-ICP-SFMS).; CNPq; FINEP

Sequential injection analysis (SIA) and response surface methodology: A versatile small volume approach for optimization of photo-Fenton processes

SANTOS, Allan C. V. dos; MASINI, Jorge C.
Fonte: ELSEVIER SCIENCE BV Publicador: ELSEVIER SCIENCE BV
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
383.2209%
Optimization of photo-Fenton degradation of copper phthalocyanine blue was achieved by response surface methodology (RSM) constructed with the aid of a sequential injection analysis (SIA) system coupled to a homemade photo-reactor. Highest degradation percentage was obtained at the following conditions [H(2)O(2)]/[phthalocyanine] = 7, [H(2)O(2)]/[FeSO(4)] = 10, pH = 2.5, and stopped flow time in the photo reactor = 30 s. The SIA system was designed to prepare a monosegment containing the reagents and sample, to pump it toward the photo-reactor for the specified time and send the products to a flow-through spectrophotometer for monitoring the color reduction of the dye. Changes in parameters such as reagent molar ratios. residence time and pH were made by modifications in the software commanding the SI system, without the need for physical reconfiguration of reagents around the selection valve. The proposed procedure and system fed the statistical program with degradation data for fast construction of response surface plots. After optimization, 97% of the dye was degraded. (C) 2009 Elsevier B.V. All rights reserved.; FAPESP; Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); CNPQ; Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Applying sequential injection analysis (SIA) and response surface methodology for optimization of Fenton-based processes

SANTOS, Allan C. V. dos; MASINI, Jorge C.
Fonte: ELSEVIER SCIENCE BV Publicador: ELSEVIER SCIENCE BV
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
386.50535%
This work presents the use of sequential injection analysis (SIA) and the response surface methodology as a tool for optimization of Fenton-based processes. Alizarin red S dye (C.I. 58005) was used as a model compound for the anthraquinones family. whose pigments have a large use in coatings industry. The following factors were considered: [H(2)O(2)]:[Alizarin] and [H(2)O(2)]:[FeSO(4)] ratios and pH. The SIA system was designed to add reagents to the reactor and to perform on-line sampling of the reaction medium, sending the samples to a flow-through spectrophotometer for monitoring the color reduction of the dye. The proposed system fed the statistical program with degradation data for fast construction of response surface plots. After optimization, 99.7% of the dye was degraded and the TOC content was reduced to 35% of the original value. Low reagents consumption and high sampling throughput were the remarkable features of the SIA system. (C) 2008 Published by Elsevier B.V.; FAPESP; Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); CNPQ

Development of a spectrophotometric Sequential Injection Analysis (SIA) procedure for determination of ammonium: A Response Surface Methodology (RSM) approach

INFANTE, Carlos M. C.; MASINI, Jorge C.; SANTOS, Allan C. V. dos
Fonte: ELSEVIER SCIENCE BV Publicador: ELSEVIER SCIENCE BV
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
379.28117%
This paper describes the optimization and use of a Sequential Injection Analysis (SIA) procedure for ammonium determination in waters. Response Surface Methodology (RSM) was used as a tool for optimization of a procedure based on the modified Berthelot reaction. The SIA system was designed to (i) prepare the reaction media by injecting an air-segmented zone containing the reagents in a mixing chamber, (ii) to aspirate the mixture back to the holding coil after homogenization, (iii) drive it to a thermostated reaction coil, where the flow is stopped for a previously established time, and (iv) to pump the mixture toward the detector flow cell for the spectrophotometric measurements. Using a 100 mu mol L(-1) ammonium solution, the following factors were considered for optimization: reaction temperature (25 - 45 degrees C), reaction time (30 - 90 s), hypochlorite concentration (20 - 40 mmol L(-1)) nitroprusside concentration (10 - 40 mmol L(-1)) and salicylate concentration (0.1 - 0.3 mol L(-1)). The proposed system fed the statistical program with absorbance data for fast construction of response surface plots. After optimization of the method, figures of merit were evaluated, as well as the ammonium concentration in some water samples. No evidence of statistical difference was observed in the results obtained by the proposed method in comparison to those obtained by a reference method based on the phenol reaction. (C) 2010 Elsevier B.V. All rights reserved.; Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq); Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Fundacao de Amparo A Pesquisa do Estado de Sao Paulo (FAPESP)[2008/09284-3]

Estudo de interação de Hg(II) com ligantes heterogêneos de ocorrência natural usando voltametria de redissolução anódica automatizada em sistema de análise por injeção sequencial; Interaction of Hg (II) with heterogeneous naturally occurring ligands studied by anodic stripping voltammetry automated by sequential injection analysis

Nascimento, Fernando Henrique do
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 07/05/2012 PT
Relevância na Pesquisa
401.2037%
Dentre as espécies químicas metálicas responsáveis pela contaminação do meio aquático, mercúrio e outros compostos mercuriais têm recebido atenção especial devido a sua alta toxicidade. Os ligantes de ocorrência natural formam complexos com íons de Hg2+, influenciando a sua biodisponibilidade. Em meio a esses ligantes, dá-se destaque aos ligantes heterogêneos de ocorrência natural (LHON), tais como substâncias húmicas e argilominerais, por sua elevada capacidade de adsorção/complexação com íons metálicos. Entre as técnicas existentes para a determinação de Hg(II), as voltamétricas, em especial a voltametria de redissolução anódica, ganham destaque devido as características que as tornam mais adequadas para estudos envolvendo interações entre LHON e Hg(II), tais como alta sensibilidade e mínima manipulação da amostra. Uma estratégia para se evitar os problemas causados pela passivação do eletrodo de trabalho por adsorção de matéria orgânica, bem como para se aumentar a robustez da técnica, é a mecanização da análise em sistema de análise por injeção sequencial (SIA). Baseando-se neste contexto, este trabalho teve por objetivo o desenvolvimento de um sistema SIA com detecção voltamétrica...

Subsídios para o desenvolvimento de um Sistema de Informações Ambientais aplicado ao licenciamento ambiental no Estado de São Paulo; Subsidies for the development of an Environmental Information System applied to the environmental licensing in São Paulo State

Nascimento, Loretha Almeida do
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 14/08/2012 PT
Relevância na Pesquisa
388.0062%
O licenciamento ambiental é um instrumento da política ambiental de caráter preventivo de proteção ao meio ambiente, estruturado em torno de procedimentos administrativos que tratam da localização, instalação, ampliação, alteração e operação de empreendimentos ou atividades que utilizam os recursos ambientais, consideradas efetiva ou potencialmente poluidoras ou que possam causar degradação ambiental. A avaliação de impactos ambientais (AIA) está acoplada a este procedimento, analisando a viabilidade ambiental de projetos e fundamentando uma decisão a respeito da implantação de atividades. Para tanto, verifica-se a necessidade de uma quantidade relativamente extensa de dados que permitam a elaboração de um diagnóstico ambiental, para fins de análise dos impactos associados ao empreendimento em questão. Sistemas de Informações ambientais (SIA) são ferramentas que possuem um grande potencial para receber, analisar e gerar informações que subsidiem as distintas etapas do licenciamento ambiental. Nesse contexto, a presente pesquisa de Mestrado procurou verificar a aplicabilidade de um SIA como ferramenta de auxilio à tomada de decisão e ao gerenciamento das atividades associadas ao licenciamento ambiental no estado de São Paulo. Por meio do estudo do processo de licenciamento e AIA implementado no estado...

Determinação simultânea de Cu(II), Pb(II), Cd(II) e Zn(II) em águas e sedimentos usando análise por injeção sequencial (SIA) com detecção voltamétrica; Simultaneous determination of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments using sequential injection analysis (SIA) with voltammetric

Ribeiro, Luiz Fernando
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 29/08/2014 PT
Relevância na Pesquisa
395.24375%
Esta dissertação descreve o desenvolvimento de uma metodologia de determinação de Cu(II), Pb(II), Cd(II) e Zn(II) em amostras ambientais por voltametria de redissolução anódica (ASV) automatizada com sistema de Análise por Injeção Sequencial (SIA). Sensores impressos com o eletrodo de trabalho de filme fino de mercúrio foram utilizados em uma cela de fluxo. As determinações foram feitas por adição de padrão, com o sistema SIA fazendo a diluição em linha da solução padrão de referência e formando na bobina coletora e auxiliar um segmento contendo as zonas de amostra, solução padrão e solução de diluição. A concentração do padrão preparada nesse segmento gerou um sinal de corrente indistinguível do sinal gerado por uma solução padrão de mesma concentração preparada em batelada em balão volumétrico. Os limites de quantificação e detecção foram da ordem de µg L-1, comparáveis à de técnicas de espectrometria atômica com detecção óptica, cujos custos instrumentais e de manutenção são significativamente maiores. Com o sistema proposto os limites de quantificação e detecção podem ser aumentados ou diminuídos pela simples alteração dos parâmetros como vazão e número de reversões de fluxo...

Sequential injection analysis system with spectrophotometric detection for determination of norfloxacin and ciprofloxacin in pharmaceutical formulations

Rufino, José Luiz; Pezza, Helena Redigolo; Pezza, Leonardo; Pinto, Paula C. A. G.; Saraiva, M. Lúcia M. F. S.; Lima, José L. F. C.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: 256-261
ENG
Relevância na Pesquisa
356.6597%
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES); This work proposes a sequential injection analysis (SIA) system for the spectrophotometric determination of norfloxacin (NOR) and ciprofloxacin (CIP) in pharmaceutical formulations. The methodology was based on the reaction of these drugs with p-(dimethylamino)cinnamaldehyde in micellar medium, producing orange colored products (λmax = 495 nm). Beer´s law was obeyed in the concentration range from 2.75x10-5 to 3.44x10-4 mol L-1 and 3.26x10-5 to 3.54x10-4 mol L-1 for NOR and CIP, respectively and sampling rate was 25 h-1. Commercial samples were analyzed and results obtained through the proposed method were in good agreement with those obtained using the reference procedure for a 95% confidence level.

Sistemas inteligentes para monitorização e controlo de processos integrados de tratamento biológico de efluentes

Pires, Olga Cristina Pereira
Fonte: Universidade do Minho Publicador: Universidade do Minho
Tipo: Tese de Doutorado
Publicado em 26/02/2008 POR
Relevância na Pesquisa
364.5946%
Tese de Doutoramento em Engenharia Química e Biológica; Os principais objectivos desta tese são: Desenvolver estratégias de engenharia de sistemas para a supervisão e controlo de processos combinados de tratamento biológico de efluentes; projectar e construir uma pequena instalação à escala laboratorial, para tratamento de um efluente sintético representativo de um efluente real processado em ETAR; desenvolver um sistema de tratamento integrado para remoção de matéria orgânica e azoto, utilizando biomassa anaeróbia para o processo de desnitrificação; desenvolver regras empíricas, relacionadas com a operação da instalação e com os processos biológicos integrados de remoção de carbono e azoto, para implementação de um sistema inteligente baseado em lógica difusa para diagnóstico e controlo do tratamento integrado. Foi concebida uma instalação à escala laboratorial para tratamento de um efluente sintético representativo de um efluente real processado em ETAR. O tratamento biológico do efluente é efectuado em três etapas principais: o processo anaeróbio onde a matéria orgânica é degradada e transformada em biogás, o processo de desnitrificação para remoção de azoto, usando o carbono remanescente do processo anaeróbio e o processo de nitrificação. Estes processos ocorrerem respectivamente no reactor anaeróbio...

Determination of gibberellic acid by sequential injection analysis using a potentiometric detector based on Mn(III)-porphyrin with improved characteristics

Santos,Emília M. G.; Couto,Cristina M. C. M.; Araújo,Alberto N.; Montenegro,M. Conceição B. S. M.; Reis,Boaventura F.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/10/2004 EN
Relevância na Pesquisa
366.84902%
This work describes the determination of gibberellic acid in growth promoters formulations used in agriculture by sequential injection analysis and potentiometric detection. The potentiometric detectors with improved characteristics used a PVC membrane prepared with Mn(III)tetraphenylporphyrin-Cl as electroactive specie. Different membranes formulated with several ionic additives were compared in order to select the most suitable one concerning slope, response time, reproducibility and selectivity. A membrane containing 6 wt% of manganese tetraphenylporphyrin-Cl [(Mn(TPP)Cl], 27 wt% of PVC, 66 wt% of dibutylphthalate (DBP), as mediator solvent, and 1 wt% of sodium tetraphenylborate, as anionic additive, was chosen for analytical applications. When coupled to a SIA system the tubular electrode presented a linear range between 5×10-4 mol L-1 and 8×10-3 mol L-1, a slope of -64.5 ± 1.6 mV/dec and lower potentiometric selectivity coefficients (log Kpot) than those obtained with the conventional electrodes. Standard deviation of 0.01 and 0.4 (n= 4) and a sampling rate of 30 samples/hour were obtained in the analysis of real samples.

Determination of metoprolol, acebutolol and propranolol in pharmaceutical formulations using the same SIA system

Passos,Marieta L. C.; Saraiva,M. Lúcia M. F. S.; Lima,José L. F. C.; Korn,M. Graças A.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2008 EN
Relevância na Pesquisa
586.50535%
A mechanized system for the determination of beta-blockers in pharmaceutical formulations is presented. Using the Sequential Injection Analysis (SIA) technique it was achieved a simple, economical and versatile methodology adaptable to any pharmaceutical control involving these substances. It does not require any pre-treatment for the samples, as they must only be dissolved in acid before analysis. Linear calibration plots were obtained for metoprolol (40.52 - 250 mg L-1), acebutolol (32.85 - 140 mg L-1) and propranolol (16.58 - 120 mg L-1). A R.S.D. lower than 5% was attained. The methodology was used in tablets, injections and prolonged-release capsules. Common excipients used in pharmaceuticals do not interfere. Statistical comparison of the results obtained with the proposed methodology and with the official methods showed good agreement (95% confidence level). SIA system produces only 2.50 mL of effluents per determination whereas the reference methodologies consume around 140 mL.

Using Sequential Injection Analysis to Improve System and Data Reliability of Online Methods: Determination of Ammonium and Phosphate in Coastal Waters

Frank, Carsten; Schroeder, Friedhelm
Fonte: Hindawi Publishing Corporation Publicador: Hindawi Publishing Corporation
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
384.23758%
This article summarises the advantages of the sequential injection analysis (SIA) for the online determination of nutrients in coastal waters. It concentrates on techniques to improve the reliability of the gained data by continuously monitoring one or more standards and on the advantages of online standard additions and offline determination of manually collected samples with the online SIA system. These measures are advantageous during method development and validation and can be used to verify the system performance on a regular base to reduce the amount of erroneous results. No changes in the flow system are necessary and the sample throughput is only slightly reduced. These techniques have been applied to a SIA system which is able to simultaneously determine ammonium and phosphate at a rate of more than 100 samples per hour each and detection limits (3σ) of 0.06 μM and 0.05 μM. Results from a campaign in summer 2005 are shown.

Stratégies et déterminants de la vaccination au Burkina Faso 1993-2003

Sia, Drissa
Fonte: Université de Montréal Publicador: Université de Montréal
Tipo: Thèse ou Mémoire numérique / Electronic Thesis or Dissertation
FR
Relevância na Pesquisa
359.09855%
Introduction : La vaccination est l’une des interventions de santé publique les plus efficaces et les plus efficientes. Comme dans la plupart des pays de la région Ouest africaine, le programme national de vaccination a bénéficié du soutien de nombreuses initiatives internationales et nationales dans le but d’accroître la couverture vaccinale. La politique vaccinale du Burkina Faso s’est appuyée sur différentes stratégies à savoir: la vaccination-prospection, la «vaccination commando», le Programme élargi de vaccination (PEV) et les Journées nationales de vaccination. La couverture vaccinale complète des enfants de 12 à 23 mois a certes augmenté, mais elle est restée en deçà des attentes passant de 34,7% en 1993, à 29,3% en 1998 et 43,9% en 2003. Objectif : Le but de cette thèse est d’analyser à plusieurs périodes et à différents niveaux, les facteurs associés à la vaccination complète des enfants de 12 à 23 mois en milieu rural au Burkina Faso. Méthodes : Nous avons utilisé plusieurs stratégies de recherche et quatre sources de données : - les enquêtes démographiques et de santé (EDS) de 1998-1999 et de 2003 - les annuaires statistiques de 1997 et de 2002 - des entretiens individuels auprès de décideurs centraux...

Development of a flow through photo-reactor to study degradation of organic compounds by Sequential Injection Analysis (SIA)

SANTOS, Allan C. V. dos; MASINI, Jorge C.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
374.62516%
This work describes a photo-reactor to perform in line degradation of organic compounds by photo-Fenton reaction using Sequential Injection Analysis (SIA) system. A copper phthalocyanine-3,4',4²,4²¢-tetrasulfonic acid tetrasodium salt dye solution was used as a model compound for the phthalocyanine family, whose pigments have a large use in automotive coatings industry. Based on preliminary tests, 97% of color removal was obtained from a solution containing 20 µmol L-1 of this dye.; Este trabalho descreve um foto-reator para a execução "in line" da degradação de compostos orgânicos através da reação de foto-Fenton, utilizando-se de um sistema de Análise por Injeção Sequencial (SIA). Uma solução do corante do sal tetrassódico de ácido 3,4',4²,4²¢-tetrassulfônico de ftalocianina de cobre foi empregada como modelo da família das ftalocianinas, cujos pigmentos apresentam grande utilização na indústria de tintas automotivas. Baseando-se em testes preliminares, uma remoção de cor de 97% foi obtida em uma solução contendo 20 µmol L-1 deste corante.; FAPESP; CNPQ

Indicadores de saúde bucal em função da organização da demanda : análise baseada no sistema de informação; Influence of scheduling clinical dental care on indicators of oral health : analysis based on the information system

Gabriela Christiel Soto Rojas
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 25/02/2014 PT
Relevância na Pesquisa
389.0229%
Apesar dos avanços e esforços feitos na implementação de políticas publicas de saúde bucal, ainda persiste a dificuldade no acesso e uso dos serviços odontológicos, como é refletido nos resultados das ultimas pesquisas de interesse nacional como a Pesquisa Nacional por Amostra de Domicílios (PNAD) 2008 e SB Brasil 2010, onde grande porcentagem da população refere nunca ter ido ao dentista. São múltiplos os fatores que facilitam ou dificultam o acesso e uso destes serviços, um deles é o modelo de organização da demanda odontológica adotada pelas Equipes de Saúde Bucal (ESB), a qual deve desenvolver ações que lidem com as necessidades agudas e crónicas dos pacientes. Assim estas ações são registradas por meio dos indicadores no Sistema de Informação Ambulatorial (SIA) e no Sistema de Informação da Atenção Básica (SIAB), para ser avaliadas e monitoradas visando um melhor acesso aos serviços. Nesse contexto, o objetivo do estudo foi analisar a influencia da organização da demanda nos indicadores de saúde bucal, por meio da comparação destes indicadores entre 5 Unidades de Saúde da Família (USF) que trabalham com modelo de demanda espontânea e 5 USF que trabalham com demanda programada em saúde bucal. Todas as USF pertencentes ao município de Piracicaba...

Development of a flow through photo-reactor to study degradation of organic compounds by Sequential Injection Analysis (SIA)

Santos,Allan C. V. dos; Masini,Jorge C.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2009 EN
Relevância na Pesquisa
366.84902%
This work describes a photo-reactor to perform in line degradation of organic compounds by photo-Fenton reaction using Sequential Injection Analysis (SIA) system. A copper phthalocyanine-3,4',4²,4²¢-tetrasulfonic acid tetrasodium salt dye solution was used as a model compound for the phthalocyanine family, whose pigments have a large use in automotive coatings industry. Based on preliminary tests, 97% of color removal was obtained from a solution containing 20 µmol L-1 of this dye.

O sistema de referência terrestre e a necessidade de um novo sistema de referência geodésico global; THE TERRESTRIAL REFERENCE SYSTEM AND THE NEED FOR A NEW GLOBAL GEODETIC REFERENCE SYSTEM

Vicente, Raimundo de Oliveira
Fonte: Universidade Federal do Paraná-UFPR Publicador: Universidade Federal do Paraná-UFPR
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; Artigo Avaliado pelos Pares Formato: application/pdf
Publicado em 21/02/2008 POR
Relevância na Pesquisa
361.6161%
As técnicas atuais da geodésia espacial (VLBI, SLR, GPS) permitem a definiçãodos sistemas de referência terrestres com maior precisão do que as técnicas clássicasque foram utilizadas na definição da origem convencional internacional - “CIO”. Aimportância da “CIO” justifica-se por ter sido adotada não só para os sucessivosalinhamentos dos diversos sistemas de referência terrestre internacional, através dopólo do “BIH”, mas também para a definição do sistema de referência geodésicoglobal de 1980 (GRS 80). Estas são as razões para a definição de uma nova origemde referência convencional internacional - “CIRO” e para a necessidade de umnovo sistema de referência geodésico global, baseados nas técnicas da geodésiaespacial, a serem adotados pelas organizações internacionais adequadas.; Present day space geodetic techniques (VLBI, SLR, GPS) lead to the definition ofterrestrial reference systems with greater precision than classical techniques whichwere employed in the definition of the conventional international origin (CIO). Theimportance of the CIO is justified by its adoption not only for the successivealignments of several ITRFs...

Premissas para o design conceitual de um Sistema de Informação Ambiental(SIA) a partir da abordagem teórica de Wenger

PIPER, Sieglinde; AGUDELO, Libia Patricia Peralta; SOUZA, Marcelo Stein de Lima
Fonte: UFPR Publicador: UFPR
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; Formato: application/pdf
Publicado em 30/06/2003 POR
Relevância na Pesquisa
376.46145%
Argumenta-se que estamos vivendo na “Era da Informação”. Neste contexto, a crescente necessidade de comunicar-se, gerar conhecimentos e transmitir idéias tem criado desafios a serem solucionados mediante o uso das Tecnologias da Informação (TI). Pesquisadores da área vêm constatando as dificuldades de identificação que existem entre os usuários e os Sistemas de Informação tradicionalmente projetados. Investigam-se neste trabalho as dimensões que devem ser levadas em conta no design conceitual de um Sistema de Informação que estimule a participação e aumente os níveis de aprendizado dos envolvidos baseado nas teorias sociais do aprendizado propostas por Etienne Wenger. Para exemplificar a aplicação das abordagens genéricas a uma área específica do conhecimento, optou-se pela investigação das premissas para o design de um Sistema de Informação Ambiental (SIA) já que considera-se que a problemática ambiental, devido à sua complexidade, promove a transformação dos atuais saberes teóricos e práticos. Aprofundaram-se assim as investigações sobre a relação entre a informação e os seres humanos, na busca e aplicação prática de um “saber ambiental”. Premises of a conceptual design of a System of Environmental Information from Wenger`s theoretical approach Abstract Some argue that we are currently living in the so called “Information Age”. In that context...

Psychology, the United Health System (SUS) and the Ambulatory Care Information System (SIA): innovations, propositions and misdirections; A Psicologia, o Sistema Único de Saúde e o Sistema de Informações Ambulatoriais: inovações, propostas e desvirtuamentos

de Oliveira, Isabel Fernandes; Dantas, Candida M. Bezerra; Costa, Ana Ludmila F.; Gadelha, Tatiane Medeiros Silva; Ribeiro, Elisa Maria Parahyba Campos; Yamamoto, Oswaldo H.
Fonte: UFPR Publicador: UFPR
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; avaliado por pares; Formato: application/pdf
Publicado em 04/04/2006 POR
Relevância na Pesquisa
393.98855%
Desde as primeiras incursões de psicólogos no sistema público de saúde discute-se a adeqüabilidade de seus padrões de atuação que, atualmente, redundam numa atenção curativa, individual e ineficiente. Contudo, ressalta-se a interferência das deliberações, orientações e exigências do Sistema Único de Saúde na figura do Sistema de Informações Ambulatoriais (SIA/SUS) que fornece uma lista de procedimentos a serem desenvolvidos pelos psicólogos. Este estudo analisou estatísticas dos procedimentos realizados pela Psicologia em Natal/RN, disponíveis no SIA/SUS, com o objetivo de dimensionar como sua estrutura influencia a manutenção dos modelos de atuação. Os dados revelam uma permanência de ações compartimentalizadas, cuja maior proporção abrange os quadros mórbidos. A dificuldade para o desenvolvimento de ações diferentes ou obriga os profissionais a registrarem-nas de forma distorcida, ou os resigna aos atendimentos previstos. Na Psicologia, o sistema de informações restringe atividades que poderiam configurar um modelo de atuação condizente com os ideais da reforma sanitária.Palavras-chave: Psicologia; Saúde Pública; Sistema de Informações Ambulatoriais.;   The adequability of Psychology patterns of intervention have been discussed since the first incursions of psychologists on the Public Health System...

Sequential injection spectrophotometric determination of V(V) in environmental polluted waters

Silva,Eliana S; Pinto,Paula CAG; Lima,José LFC; Saraiva,M Lúcia MFS
Fonte: Water SA Publicador: Water SA
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/04/2009 EN
Relevância na Pesquisa
379.41047%
A fast and robust sequential injection analysis (SIA) methodology for routine determination of V(V) in environmental polluted waters is presented. The determination was based on the oxidation of dopamine (DP) by V(V) in acidic medium followed by coupling of the formed intermediary with 4-aminoantipyrine (4AAP) to yield a violet product (λ=565 nm). The operation mode of the SIA system allowed the implementation of a stopped flow procedure in which the reaction zone was stopped for 180 s in the reaction coil before reaching the spectrophotometric detector, with the aim of increasing the sensitivity. Linear calibration plots were obtained for V(V) concentrations between 0.50 and 5.0 mg·ℓ-1. The developed methodology exhibits a good precision, with relative standard deviation (rsd) < 2.0% (n=15) and the detection limit was 0.39 mg·ℓ-1. The presented SIA methodology was applied to the determination of V(V) in 10 water samples and in a wastewater reference certified sample. The determination of V(V) by the developed automatic procedure involved the consumption of 1.9 mg of 4AAP and 2.9 mg of DP and the production of 2.35 mℓ of effluent.