Página 1 dos resultados de 603 itens digitais encontrados em 0.119 segundos

Effect of casting atmosphere on the shear bond strength of a ceramic to Ni-Cr and Ni-Cr-Be alloys

PAGNANO, Valéria Oliveira; ESQUIVEL, Marina de Campos; LEAL, Mônica Barbosa; FELIPUCCI, Daniela Nair Borges; BEZZON, Osvaldo Luiz
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
708.52484%
The success of metal-ceramic restorations depends on an optimal bond between metal and ceramic. This study evaluated the effect of 3 casting atmospheres on the metal-ceramic bond strength (MCBS) of 2 Ni-Cr alloys, with beryllium (Fit Cast V) and without beryllium (Fit Cast SB). Sixty acrylic resin patterns (8 mm long and 5 mm diameter) were obtained using a fluorocarbon resin matrix. Wax was used to refine the surface of acrylic resin patterns that were invested and cast in an induction casting machine under normal, vacuum, and argon atmospheres at a temperature of 1340ºC. The castings were divested manually and airborne-particle abraded with 100-µm aluminum-oxide. Ten castings were obtained for each group. The IPS Classic V ceramic was applied (2 mm high and 5 mm diameter). The shear bond strength was tested in a mechanical testing machine with a crosshead speed of 2.0 mm/min. The MCBS data (MPa) were subjected to 2-way analysis of variance (α=0.05). There was no statistically significant difference (p>0.05) between the alloys or among the casting atmospheres. Within the limitations of this study, it may be concluded that the presence of beryllium and the casting atmosphere did not interfere in the MCBS of the evaluated metal-ceramic combinations; O sucesso das restaurações metalocerâmicas depende da ótima união entre metal e cerâmica. Este estudo avaliou o efeito de 3 atmosferas de fundição na resistência de união metalocerâmica (RUMC) de 2 ligas de Ni-Cr...

Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks

TIOSSI, R.; FALCAO-FILHO, H.; AGUIAR JUNIOR, F. A.; RODRIGUES, R. C.; MATTOS, M. da G.; RIBEIRO, R. F.
Fonte: WILEY-BLACKWELL Publicador: WILEY-BLACKWELL
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
512.3498%
P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side...

Efeito de diferentes tipos de soldagem na resistência à tração de estruturas fundidas com ligas de Ni-Cr; Effects of different types of welding on the tensile strenght of NI-Cr structures

Mansano, Romão Adalberto de Souza
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 21/05/2007 PT
Relevância na Pesquisa
504.12406%
A confecção de infra-estruturas metálicas em reabilitações orais, envolvem processos criteriosos principalmente no que concerne ao processo de fundição e soldagem das mesmas. O objetivo deste trabalho foi avaliar a resistência à tração de peças fundidas em monobloco com três diferentes métodos de soldagem: solda convencional (maçarico), solda a laser e solda TIG (tungstênio Inerte Gás). Oitenta padrões de plástico pré-fabricados (vinte para cada grupo) foram fundidos em liga de Ni-Cr, sendo o grupo controle (monobloco) unido previamente à fundição. Após, os corpos-de-prova do grupo teste foram divididos aleatoriamente para posterior soldagem e teste de resistência, realizado em uma máquina de ensaios mecânicos (Kratos). Os resultados médios (MPa) foram: monobloco 784,08, solda laser 588,42, solda convencional 366,80 e solda TIG 319,78. Os dados foram submetidos á analise estatística ANOVA e teste de Tukey (p,0,05), sendo que o grupo controle (monobloco) apresentou valores de resistência estatisticamente superior a todos os do grupo teste. Entre as peças soldadas, a solda laser apresentou valores de resistência estatisticamente superior em relação aos grupos (convencional e TIG), os quais não diferiram estatisticamente entre si. Concluí-se que apesar de ter havido diferenças estatísticas entre os grupos...

Avaliação da adaptação marginal de copings metálicos fundidos em ligas de níquel-cromo, níquel-cromo-berílio e em titânio comercialmente puro em função da aplicação de espaçadores; Evaluation of the use of die spacer over the marginal fit of casting copings of Ni-Cr, Ni-Cr-Be and commercially pure Titanium

Soriani, Natércia Carreira
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 01/02/2008 PT
Relevância na Pesquisa
714.1063%
O objetivo do trabalho foi avaliar o efeito do uso de espaçadores na adaptação marginal de copings confeccionados em ligas de Ni-Cr (Verabond II) (VB II) e Ni-Cr-Be (Verabond) (VB) e Titânio cp (Tritan) (Ti-cp) fundidos pela técnica de cera perdida. A partir de uma matriz metálica, foram obtidos 135 troquéis de gesso resinado tipo IV para confecção dos padrões de cera nas seguintes condições: sem a presença de espaçador (G0), com uma camada de espaçador (G1) e com duas camadas de espaçador (G2), com quinze repetições para cada grupo. Foi realizado o enceramento de cada troquel e os padrões de cera foram incluídos em revestimento adequado para cada material. Em cada anel de fundição foram incluídos 3 padrões de cera, sendo cada um correspondente a cada condição. Cada coping, adaptado à matriz metálica por meio de um dispositivo padronizador da pressão de assentamento, foi levado ao Microscópio Óptico para aferição das medidas da desadaptação marginal. Os dados obtidos (µm) foram submetidos à análise estatística (ANOVA) e teste de Tukey (p<0.05). Para a condição material, a liga VB (118,73) não apresentou diferença estatisticamente significante em relação à liga VB II (93,40), sendo que estas apresentaram diferença estatisticamente significante em relação ao Ti-cp (168...

Efeito da sinterização da cerâmica no desajuste marginal de coroas metalocerâmicas de níquel-cromo e cobalto-cromo; The effect of ceramics sintering in the marginal misfit on nickel-chromium and cobalt-chromium metal-ceramic crowns

Dias, Ana Paula
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 11/12/2013 PT
Relevância na Pesquisa
514.61914%
A adaptação marginal é fundamental para o sucesso clínico e longevidade das coroas metalocerâmicas. O objetivo deste trabalho foi avaliar, por meio de microscopia óptica, o desajuste marginal de copings metalocerâmicos obtidos com as ligas metálicas de Ni-Cr [Verabond II e experimental (SR)] e Co-Cr (Keragen). As leituras foram realizadas antes da sinterização (T1), após a sinterização do opaco (T2) e após a sinterização da cerâmica (T3). A partir de uma matriz metálica e uma contra-matriz de teflon, encaixada sobre o preparo da matriz, foram obtidos 30 padrões de resina acrílica Duralay/cera com espessura de 0,7 mm (n=30), que foram incluidos em anel com revestimento Microfine (Talladium). Após a fundição, os copings foram desincluídos, jateados e usinados. Cada copings, adaptado à outra matriz metálica por meio de um padronizador da pressão de assentamento, foi levado ao microscópio óptico. Foram selecionados dois pontos equidistantes de um ponto selecionado no copings, que representava ¼ de volta no dispositivo de leitura, totalizando 8 leituras por etapa em cada copings. Os dados de desajuste marginal (μm) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados mostraram que houve diferença para os fatores: tempo (p=0...

Electrodeposition of amorphous Fe-Cr-P-Ni-C alloys. Morphological and structural characteristics

De Souza, Carlos Alberto C.; Carlos, Ivani A.; Bidoia, Ederio D.
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Conferência ou Objeto de Conferência Formato: 39-44
ENG
Relevância na Pesquisa
509.90562%
The effect of bath composition and electroplating conditions on structure, morphology and composition of amorphous Fe-Cr-P-Ni-C deposits on Cu substrate was investigated. The deposition efficiency of Fe-Ni-P-C alloy increased significantly with the addition of formic acid, but decreased with the addition of Cr to the plating bath. The increase of charge density activates the inclusion of Cr in the deposit. However, above a specific value of charge density, which depends on deposition current density, the Cr content in the deposit decreases. SEM analysis showed that the increase of Ni, Cr or charge deposition promotes susceptibility to microcracking.

Influência do método de aquecimento de revestimentos fosfatados sobre sua resistência à compressão e sobre a rugosidade de superfície e estabilidade dimensional de ligas de Ni-Cr e Ni-Cr-Ti

Zequetto, Michele Marques
Fonte: Universidade Estadual Paulista (UNESP) Publicador: Universidade Estadual Paulista (UNESP)
Tipo: Tese de Doutorado Formato: 119 f. : il. + 1 CD-ROM
POR
Relevância na Pesquisa
511.7032%
Pós-graduação em Odontologia - FOA; No processo de fundição pela cera perdida, os materiais envolvidos podem apresentar interações entre si e o de tempo despendido para se obter as estruturas metálicas é oneroso. Assim, o objetivo deste trabalho foi avaliar a influência da propriedade física de resistência à compressão de revestimentos fosfatados indicados para altas temperaturas de fundição, utilizando os métodos de aquecimento convencional (MAC) e rápido (MAR), e analisar a rugosidade de superfície e a alteração dimensional do produto final da fundição (a peça metálica) obtido com as ligas metálicas Ni-Cr (Verabond II) e Ni-Cr-Ti (Fit Cast Titanium). Os revestimentos estudados Castorit Super C, Castorit All Speed, Heat Shock e Micro Fine 1700 foram vazados em uma matriz de silicone que permitiu obter amostras com formato cilíndrico (n=200), medindo 10mm de diâmetro e 20mm de comprimento. A resistência (MPa) deles foi determinada à temperatura ambiente (resistência fria) após 15, 30 e 60 minutos de manipulação, e também imediatamente após serem submetidos aos métodos de aquecimento MAC e MAR (resistência de queima), por meio de uma máquina de ensaio universal, em velocidade de 0,05mm/min e carga de 150kgf. Após inclusão...

Structural and morphological investigations of the electrodeposited Cr and Ni-Cr-P coatings and their electrochemical behaviors in chloride aqueous medium

Lima-Neto,Pedro de; Correia,Adriana N.; Silva,Gecílio P. da
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2006 EN
Relevância na Pesquisa
1125.8364%
Structural and morphological characteristics of the electrodeposited Cr and Ni-Cr-P coatings and their corresponding electrochemical behaviors in chloride aqueous medium were investigated here. All coatings were electrodeposited on copper. Cr coatings were obtained from an industrial plating solution and amorphous Ni-Cr-P coatings were successfully obtained at 60ºC in the range of 100 to 400 mA cm-2, using a plating solution at pH 2 containing 40 g L-1 NiCl2.6H2O; 102 g L-1 CrCl3; 14 g L-1 NaPH2O2; 30 g L-1 H3BO3; 15 g L-1 NaBr; 50 g L-1 NH4Cl, 80 g L-1 Na3C6H5O7 .2H2O and 40 mL L-1 HCOOH. The coatings were obtained using constant charges of 500 and 1600 Coulombs. The characterization of the coatings was carried out by Scanning Electron Microscopy (SEM), X-ray Diffraction (XRD), Differential Scanning Calorimetry (DSC) and Energy Dispersive X-ray Analysis (EDX) techniques. The electrochemical behavior of both coatings was evaluated by potentiodynamic polarization curves, at room temperature, in 0.1 mol L-1 NaCl aqueous solution. It was not observed cracks on the electrodeposited Ni-Cr-P coatings and the surface morphology was characterized by the presence of spherical nodules. The crystallization of these coatings occurred at 325 °C with the formation of Ni and Ni3P phases. All the annealed Cr coatings showed cracked surfaces. The presence of cracks impairs the mechanical and corrosion resistance properties of Cr coatings. The hardness of the Ni-Cr-P was increased with the increase of the annealing temperature. Spherical noodles were absent in the surface of as-annealed Ni-Cr-P coating which it was associated with the diffusion of Cr to the surface and cracks were not observed in any annealing temperature. Among the various electrodeposited Ni-Cr-P coatings studied here...

Flexural strength of pure Ti, Ni-Cr and Co-Cr alloys submitted to Nd:YAG laser or TIG welding

Rocha,Rick; Pinheiro,Antônio Luiz Barbosa; Villaverde,Antonio Balbin
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2006 EN
Relevância na Pesquisa
506.10586%
Welding of metals and alloys is important to Dentistry for fabrication of dental prostheses. Several methods of soldering metals and alloys are currently used. The purpose of this study was to assess, using the flexural strength testing, the efficacy of two processes Nd:YAG laser and TIG (tungsten inert gas) for welding of pure Ti, Co-Cr and Ni-Cr alloys. Sixty cylindrical specimens were prepared (20 of each material), bisected and welded using different techniques. Four groups were formed (n=15). I: Nd:YAG laser welding; II- Nd:YAG laser welding using a filling material; III- TIG welding and IV (control): no welding (intact specimens). The specimens were tested in flexural strength and the results were analyzed statistically by one-way ANOVA. There was significant differences (p<0.001) among the non-welded materials, the Co-Cr alloy being the most resistant to deflection. Comparing the welding processes, significant differences (p<0.001) where found between TIG and laser welding and also between laser alone and laser plus filling material. In conclusion, TIG welding yielded higher flexural strength means than Nd:YAG laser welding for the tested Ti, Co-Cr and Ni-Cr alloys.

Effect of casting atmosphere on the shear bond strength of a ceramic to Ni-Cr and Ni-Cr-Be alloys

Pagnano,Valéria Oliveira; Esquivel,Marina de Campos; Leal,Mônica Barbosa; Felipucci,Daniela Nair Borges; Bezzon,Osvaldo Luiz
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2009 EN
Relevância na Pesquisa
700.5309%
The success of metal-ceramic restorations depends on an optimal bond between metal and ceramic. This study evaluated the effect of 3 casting atmospheres on the metal-ceramic bond strength (MCBS) of 2 Ni-Cr alloys, with beryllium (Fit Cast V) and without beryllium (Fit Cast SB). Sixty acrylic resin patterns (8 mm long and 5 mm diameter) were obtained using a fluorocarbon resin matrix. Wax was used to refine the surface of acrylic resin patterns that were invested and cast in an induction casting machine under normal, vacuum, and argon atmospheres at a temperature of 1340ºC. The castings were divested manually and airborne-particle abraded with 100-µm aluminum-oxide. Ten castings were obtained for each group. The IPS Classic V ceramic was applied (2 mm high and 5 mm diameter). The shear bond strength was tested in a mechanical testing machine with a crosshead speed of 2.0 mm/min. The MCBS data (MPa) were subjected to 2-way analysis of variance (α=0.05). There was no statistically significant difference (p>0.05) between the alloys or among the casting atmospheres. Within the limitations of this study, it may be concluded that the presence of beryllium and the casting atmosphere did not interfere in the MCBS of the evaluated metal-ceramic combinations

Correlation between metal-ceramic bond strength and coefficient of linear thermal expansion difference

LOPES, Stella Crosara; PAGNANO, Valéria Oliveira; ROLLO, João Manuel Domingos de Almeida; LEAL, Mônica Barbosa; BEZZON, Osvaldo Luiz
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
504.12406%
The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14)...

Brasagem dos aços inoxidáveis duplex 'baixa liga' UNS S32101, UNS S32304 e superduplex UNS S32750 com metal de adição AWS A5.3 tipo BNi-7 (Ni-Cr-P); Brazing of UNS S32101 and UNS S32304 lean duplex stainless steels and UNS S32750 superduplex with AWS A5.3 BNi-7 (Ni-Cr-P) filler metal

Centeno, Dany Michell Andrade; Carvalho Junior, Clovis; Brandi, Sergio Duarte
Fonte: São Paulo Publicador: São Paulo
Tipo: Artigo de Revista Científica
POR
Relevância na Pesquisa
702.6638%
Os aços inoxidáveis duplex, devido à sua resistência à corrosão, têm uma grande aplicação em diversos segmentos industriais, onde a resistência à corrosão é uma propriedade requerida. Por terem resistência mecânica superior aos aços inoxidáveis ferríticos e austeníticos convencionais, podem produzir equipamentos mais leves. Quando ciclados termicamente, estes aços podem ter suas propriedades alteradas, principalmente quando se emprega processos de junção, como a brasagem, e quando ocorre o desbalanceamento da fração volumétrica ferrita/austenita. O objetivo deste trabalho é caracterizar a brasagem de aços inoxidáveis duplex 'baixa liga' e superduplex, verificando o efeito da folga e do tempo de brasagem na formação de intermetálicos contínuos no interior da junta brasada. Neste trabalho foram brasados, em forno continuo com atmosfera de hidrogênio, corpos-de-prova de aço inoxidável duplex UNS S32101, UNS S32304 e UNS S32750 com a adição para brasagem BNi-7 (Ni-Cr-P), na temperatura de 1100oC, por tempos de 12 min e 32 min, utilizando-se folgas das juntas de 0,0 e 0,3 mm, seguidos de resfriamento em forno. Os corpos de prova foram caracterizados utilizando-se microscópio óptico, microscópio eletrônico de varredura com EDS e difração de raios X. Os resultados mostraram que a melhor condição para a brasagem em forno empregado foi a brasagem com a folga de 0...

Shear bond strength between Ni-Cr alloy bonded to a ceramic substrate

Nascimento, Cassio do; Miani, Paola Kirsten; Bezzon, Osvaldo Luiz; Goncalves, Mariane; Albuquerque Junior, Rubens Ferreira de
Fonte: WILEY-BLACKWELL; HOBOKEN Publicador: WILEY-BLACKWELL; HOBOKEN
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
708.1101%
Shear bond strength between Ni-Cr alloy bonded to a ceramic substrate Introduction: The aim of this study was to evaluate the shear bond strength between a Ni-Cr alloy and a ceramic system submitted or not to thermocycling. Materials and methods: Forty-eight cylinder blocks of Ni-Cr with 3.0 mm diameter by 4.0 mm hight and 48 disc-shaped specimens (7.0 mm in diameter by 2.0 mm thick) composed of ceramic were prepared. The Ni-Cr cylinder blocks were randomised in two groups of 24 specimens each. One group was submitted to air-particle abrasion (sandblasting) with 50 mu m Al2O3 (0.4-0.7 MPa) during 20 s, and the other group was submitted to mechanical retentions with carbide burrs. Each group was subdivided into other two groups (n = 12), submitted or not to thermocycling (500 cycles, 5-55 degrees C). The cylinder blocks were bonded to the disc-shaped ceramic specimens under 10 N of load. The shear bond strengths (MPa) were measured using a universal testing machine at a cross head speed of 0.5 mm/min and 200 kgf of load. The data were submitted to statistical analysis (ANOVA and Tukey's test). Results: The air-particle abrasion group exhibited significantly higher shear bond strength when compared to drilled group (p < 0.05). Conclusions: Thermocycling decreased significantly the bond strengths for all groups tested.

Correlation between metal-ceramic bond strength and coefficient of linear thermal expansion difference

Lopes,Stella Crosara; Pagnano,Valéria Oliveira; Rollo,João Manuel Domingos de Almeida; Leal,Mônica Barbosa; Bezzon,Osvaldo Luiz
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/04/2009 EN
Relevância na Pesquisa
504.12406%
The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14)...

Microhardness of Ni-Cr alloys under different casting conditions

Bauer,José Roberto de Oliveira; Loguercio,Alessandro Dourado; Reis,Alessandra; Rodrigues Filho,Leonardo Eloy
Fonte: Sociedade Brasileira de Pesquisa Odontológica - SBPqO Publicador: Sociedade Brasileira de Pesquisa Odontológica - SBPqO
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/03/2006 EN
Relevância na Pesquisa
520.53934%
This study evaluated the microhardness of Ni-Cr alloys used in fixed prosthodontics after casting under different conditions. The casting conditions were: (1-flame/air torch) flame made of a gas/oxygen mixture and centrifugal casting machine in a non-controlled casting environment; (2-induction/argon) electromagnetic induction in an environment controlled with argon; (3-induction/vacuum) electromagnetic induction in a vacuum environment; (4-induction/air) electromagnetic induction in a non-controlled casting environment. The 3 alloys used were Ni-Cr-Mo-Ti, Ni-Cr-Mo-Be, and Ni-Cr-Mo-Nb. Four castings with 5 cylindrical, 15 mm-long specimens (diameter: 1.6 mm) in each casting ring were prepared. After casting, the specimens were embedded in resin and polished for Vickers microhardness (VH) measurements in a Shimadzu HMV-2 (1,000 g for 10 s). A total of 5 indentations were done for each ring, one in each specimen. The data was subjected to two-way ANOVA and Tukey's multiple comparison tests (alpha = 0.05). The VH values of Ni-Cr-Mo-Ti (422 ± 7.8) were statistically higher (p < 0.05) than those of Ni-Cr-Mo-Nb (415 ± 7.6). The lowest VH values were found for Ni-Cr-Mo-Be (359 ± 10.7). The VH values obtained in the conditions induction/argon and induction/vacuum were similar (p > 0.05) and lower than the values obtained in the conditions induction/air and flame/air torch (p < 0.05). The VH values in the conditions induction/air and flame/air were similar (p > 0.05). The microhardness of the alloys is influenced by their composition and casting method. The hardness of the Ni-Cr alloys was higher when they were cast with the induction/air and flame/air torch methods.

Evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys

Costa,Heloisa Módena Ferreira da; Rodrigues,Renata Cristina Silveira; Mattos,Maria da Glória Chiarello de; Ribeiro,Ricardo Faria
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2003 EN
Relevância na Pesquisa
513.5853%
Several formulations of alternative alloys have been proposed for the substitution of gold-based alloys used in Dentistry. Recently, a Ni-Cr-Ti-based alloy has been introduced. The purpose of this work was to verify the marginal adaptation obtained with one-piece superstructures for implant-supported prostheses obtained in Ni-Cr-Ti alloy, compared to a semi-noble alloy Pd-Ag. Eight superstructures for each alloy were produced over 4 implants in the anterior region of the mandible. The superstructures were placed in a torquemeter and the fixation screw of implant #1 was tightened with a 20 Ncm load with the others loosened (Sheffield test). The unfitness (in mm) was measured using a three-dimensional optical measurer in each implant, in the buccal and lingual aspects. The obtained data were submitted to statistical analysis by the analysis of variance and Tukey's test at 5% level. Significant differences were found for the factors material (p<0.05), with Ni-Cr-Ti pieces better than Pd-Ag ones, and implants (p<0.01). There were no significant differences for the factor position and interactions among factors (p>0.05). Based on the analysis of the data, it is possible to conclude that the Ni-Cr-Ti alloy makes possible the obtainment of one-piece implant-supported superstructures with a smaller misfit compared to the one obtained in Pd-Ag alloy...

Brasagem dos aços inoxidáveis duplex 'baixa liga' UNS S32101, UNS S32304 e superduplex UNS S32750 com metal de adição AWS A5.3 tipo BNi-7 (Ni-Cr-P)

Centeno,Dany Michell Andrade; Carvalho Jr.,Clovis; Brandi,Sérgio Duarte
Fonte: Associação Brasileira de Soldagem Publicador: Associação Brasileira de Soldagem
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2013 PT
Relevância na Pesquisa
1002.6638%
Os aços inoxidáveis duplex, devido à sua resistência à corrosão, têm uma grande aplicação em diversos segmentos industriais, onde a resistência à corrosão é uma propriedade requerida. Por terem resistência mecânica superior aos aços inoxidáveis ferríticos e austeníticos convencionais, podem produzir equipamentos mais leves. Quando ciclados termicamente, estes aços podem ter suas propriedades alteradas, principalmente quando se emprega processos de junção, como a brasagem, e quando ocorre o desbalanceamento da fração volumétrica ferrita/austenita. O objetivo deste trabalho é caracterizar a brasagem de aços inoxidáveis duplex 'baixa liga' e superduplex, verificando o efeito da folga e do tempo de brasagem na formação de intermetálicos contínuos no interior da junta brasada. Neste trabalho foram brasados, em forno continuo com atmosfera de hidrogênio, corpos-de-prova de aço inoxidável duplex UNS S32101, UNS S32304 e UNS S32750 com a adição para brasagem BNi-7 (Ni-Cr-P), na temperatura de 1100ºC, por tempos de 12 min e 32 min, utilizando-se folgas das juntas de 0,0 e 0,3 mm, seguidos de resfriamento em forno. Os corpos de prova foram caracterizados utilizando-se microscópio óptico, microscópio eletrônico de varredura com EDS e difração de raios X. Os resultados mostraram que a melhor condição para a brasagem em forno empregado foi a brasagem com a folga de 0...

The in?uence of Al:Nb ratio on the microstructure and mechanical response of quaternary Ni?Cr?Al?Nb alloys

Mignanelli, P. M.; Jones, N. G.; Hardy, M. C.; Stone, H. J.
Fonte: Elsevier Publicador: Elsevier
Tipo: Article; published version
EN
Relevância na Pesquisa
583.47797%
This is the final published version, which can also be found on the Elsevier website at: http://www.sciencedirect.com/science/article/pii/S0921509314007369#; The influence of Al:Nb ratio on the microstructure and properties of Ni?Cr?Al?Nb alloys has been investigated following long-term exposure at elevated temperatures. The ?? volume fraction, size and lattice misfit were seen to increase with a larger Al:Nb ratio, although these changes resulted in reduced hardness. The change in the critical resolved shear stress (CRSS) associated with strong dislocation coupling was determined to be the dominant strengthening mechanism and increased with decreasing Al:Nb ratio. A distribution of tertiary ?? was observed to be necessary in maximising the mechanical properties of these alloys.; This work was supported by the EPSRC/Rolls-Royce Strategic Partnership (EP/H022309/1 and EP/H500375/1).

Correlation between metal-ceramic bond strength and coefficient of linear thermal expansion difference

Lopes, Stella Crosara; Pagnano, Valéria Oliveira; Rollo, João Manuel Domingos de Almeida; Leal, Mônica Barbosa; Bezzon, Osvaldo Luiz
Fonte: Universidade de São Paulo. Faculdade de Odontologia de Bauru Publicador: Universidade de São Paulo. Faculdade de Odontologia de Bauru
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; Formato: application/pdf
Publicado em 01/04/2009 ENG
Relevância na Pesquisa
504.12406%
The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14)...

Estudo Microestrutural e Eletroquímico de Ligas Ni-Cr-Mo Usadas em Próteses Dentárias Depois de Diferentes Processos de Refundição

Sousa,Lucíola Lucena de; Felipe,Hamilton de; Codaro,Eduardo Norberto; Nakazato,Roberto Zenhei
Fonte: LNEG - Laboratório Nacional de Energia e Geologia, I.P. Publicador: LNEG - Laboratório Nacional de Energia e Geologia, I.P.
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/03/2010 PT
Relevância na Pesquisa
583.47797%
Ligas Ni-Cr-Mo são amplamente utilizadas como próteses dentárias fixas, sendo utilizados diferentes procedimentos de refundição que podem alterar as propriedades mecânicas e resistência à corrosão. O objetivo desse trabalho foi analisar o comportamento eletroquímico, as microestruturas e a dureza de duas ligas refundidas pelo processo de refundição em chama aberta (maçarico oxi-GLP) e por indução em forno de alta frequência. A análise metalográfica revelou estruturas dendríticas com grãos largos e precipitados nos seus contornos. As ligas refundidas por indução apresentam menor resistência à corrosão em soro fisiológico, a 37 ºC e maiores valores de dureza.