Aiming at the determination of toxic and essential elements in Brazilian commercial bovine milk, 25 ultra high temperature (UHT) milk samples were acquired in the local market of Piracicaba, SP. The samples were freeze-dried and analyzed by instrumental neutron activation analysis (INAA) allowing the determination of Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn. When the results were expressed as concentration (mg.l(-1)) no significant differences were found. However, considering the dry matter, results showed a clear difference between the mass fractions (mg.kg(-1) d.w.) of skim milk and whole milk for the elements Br, Ca, K, Na, Rb and Zn, indicating that the removal of fat caused a concentration effect in the dry matter of skim milks. Discrepancies were found between the concentrations of Ca and Na measured by INAA and the values informed in the labels. Ca showed variations within 30% for most samples, while concentrations of Na were up to 190% higher than informed values. The sample preparation and the LNAA procedure were appropriate for the determination of Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn in milk samples.

Further investigating the determination of phosphorus in plants by INAA using bremsstrahlung measurement

Matsubara, Tassiane C. M.; Bacchi, Marcio A.; De Nadai Fernandes, Elisabete A.
Fonte: SPRINGER; DORDRECHT Publicador: SPRINGER; DORDRECHT
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
38.28573%
Phosphorus is an essential element for plants and animals, playing a fundamental role in the production of biochemical energy. Despite its relevance, phosphorus is not commonly determined by instrumental neutron activation analysis (INAA), because (32)P does not emit gamma-rays in its decay. There are alternative methods for the determination of phosphorus by INAA, such as the use of beta counting or the measurement of bremsstrahlung originated from the high energy beta particle from (32)P. Here the determination of phosphorus in plant materials by measuring the bremsstrahlung production was further investigated, to optimize an analytical protocol for minimizing interferences and overcoming the poor specificity. Eight certified reference materials of plant matrices with phosphorus ranging between 171 and 5,180 mg kg(-1) were irradiated at a thermal neutron flux of 9.5 x 10(12) cm(-2) s(-1) and measured with a HPGe detector at decay times varying from 7 to 60 days. Phosphorus solutions added to a certified reference material at three levels were used for calibration. Counts accumulated in the baseline at four different regions of the gamma-ray spectra were tested for the determination of phosphorus, with better results for the 100 keV region. The Compton scattering contribution in the selected range was discounted using an experimental peak-to-Compton factor and the net areas of all peaks in the spectra with energies higher than 218 keV...

Chemical and physical factors influencing lead and copper contamination in drinking water: approach for a case study in analytical chemistry

Grigoletto, Tahuana Luiza Bim; Fuzari, Bruno Henrique Cervantes; Andrade, Adalgisa Rodrigues de; Campos, Maria Lucia Arruda de Moura; Gerlach, Raquel Fernanda; Santos, Jose Eduardo Tanus dos
Fonte: SOC BRASILEIRA QUIMICA; SAO PAULO Publicador: SOC BRASILEIRA QUIMICA; SAO PAULO
Tipo: Artigo de Revista Científica
POR
Relevância na Pesquisa
68.32534%
CHEMICAL AND PHYSICAL FACTORS INFLUENCING LEAD AND COPPER CONTAMINATION IN DRINKING WATER: APPROACH FOR A CASE STUDY IN ANALYTICAL CHEMISTRY. Lead and copper concentrations in drinking water increase considerably on going from municipality reservoirs to the households sampled in Ribeirao Preto (SP-Brazil). Flushing of only 3 liters of water reduced metal concentrations by more than 50%. Relatively small changes in water pH rapidly affected corrosion processes in lead pipes, while water hardness appeared to have a long-term effect. This approach aims to encourage University teachers to use its content as a case study in disciplines of Instrumental Analytical Chemistry and consequently increase knowledge about drinking water contamination in locations where no public monitoring of trace metals is in place.

Fatores químicos e físicos que afetam a contaminação por chumbo e cobre em água potável: uma abordagem para o estudo de caso em química analítica; Chemical and physical factors influencing lead and copper contamination in drinking water: approach for a case study in analytical chemistry

Grigoletto, Tahuana Luiza Bim; Fuzari, Bruno Henrique Cervantes; Andrade, Adalgisa Rodrigues de; Campos, Maria Lucia Arruda de Moura; Gerlach, Raquel Fernanda; Santos, Jose Eduardo Tanus dos
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica
POR
Relevância na Pesquisa
57.942397%
Lead and copper concentrations in drinking water increase considerably on going from municipality reservoirs to the households sampled in Ribeirão Preto (SP-Brazil). Flushing of only 3 liters of water reduced metal concentrations by more than 50%. Relatively small changes in water pH rapidly affected corrosion processes in lead pipes, while water hardness appeared to have a long-term effect. This approach aims to encourage University teachers to use its content as a case study in disciplines of Instrumental Analytical Chemistry and consequently increase knowledge about drinking water contamination in locations where no public monitoring of trace metals is in place.

Dissolução eletrolítica de ligas de alumínio em cavacos e determinação dos elementos constituintes por espectrometria de emissão atômica com fonte de pasma (ICP-OES); Electrolytic dissolution of aluminum alloys (Chip form) and multi-element determination by inductively coupled plasma optical emission spectrometry (ICP-OES)

Grigoletto, Tânia
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 20/03/2001 PT
Relevância na Pesquisa
38.575278%
Várias ligas de Al em cavacos, com diferentes granulometrias foram dissolvidas de modo convencional, com ataque por água régia. Este tipo de decomposição resulta, muitas vezes, em resíduos sólidos, cujas quantidades dependem dos teores de silício. A fim de se comparar os resultados, procedeuse, com esses resíduos, de dois modos distintos: ou foram desprezados ou foram decompostos com ácido fluorídrico, eliminando-se o silício, dissolvendo-se o restante com ácido nítrico e agrupando-o à primeira solução para a determinação de Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb, Sn, Ti e Zr por ICP-OES. Foi avaliada a influência de quantidades crescentes de Al na determinação destes elementos e, também, a provável interferência espectral de Cu na determinação do Zn (com e sem separação eletrolítica de Cu). A dissolução eletrolítica de ligas de alumínio em cavacos foi estudada pressionando-os contra um eletrodo de platina para que se comportassem como se fossem o próprio ânodo e a eletrólise ocorresse. Uma célula foi construída utilizando-se um tubo (corpo de seringa de 2,5 mL) com perfurações ao redor da base aberta, onde foi colocada uma malha sintética (perlon) no fundo e, sobre esta, a amostra. Na parte superior foi introduzido um pequeno tarugo de acrílico com um fio de platina passando pelo seu interior e com um orifício por onde passava o fluxo (4...

Caracterização química de tomates (Lycopersicon esculentum Mill.) empregando análise por ativação neutrônica instrumental; Chemical characterization of tomatoes (Lycopersicon esculentum Mill.) by using instrumental neutron activation analysis

Ferrari, Angela Aparecida
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 30/09/2008 PT
Relevância na Pesquisa
48.424287%
O tomate é a segunda hortaliça mais produzida no mundo, superada apenas pela batata, com participação efetiva na dieta humana. O seu valor como alimento traz um paradoxo. Ao mesmo tempo em que é elogiado por ser considerado um alimento funcional, com propriedades nutracêuticas, sofre críticas pela forma como é normalmente produzido, sob pesadas quantidades de fertilizantes sintéticos e pesticidas. Há muitas causas de variação que podem alterar a composição dos frutos. Neste sentido, o presente trabalho procurou coletar amostras em um universo que engloba diferentes fatores, incluindo cultivares para o consumo in natura e para o processamento industrial, sistemas de cultivo convencional e orgânico, regiões geográficas e tipos de solo. O objetivo geral foi caracterizar o tomate quanto aos elementos químicos visando a identificação daqueles de interesse agronômico ou nutricional e o estabelecimento das faixas de concentrações para frutos produzidos sob as fontes diversas de variação. Objetivos específicos envolveram estudos de representatividade amostral e de influência dos estádios de maturação e do solo na composição química dos frutos. Os tomates das cultivares AP 533, Colibri e T-92 foram coletados em propriedades localizadas em municípios do estado de São Paulo. A determinação dos elementos químicos foi feita pelo método primário de análise por ativação neutrônica instrumental (INAA). A qualidade do procedimento analítico foi verificada por meio da exatidão e da reprodutibilidade dos resultados com o emprego de materiais de referência. O estudo de representatividade amostral revelou que o número necessário de amostras para representar o tomate no campo foi inferior a 12...

DDesenvolvimento de eletrodos modificados e métodos analíticos; Development of modified electrodes and analytical methods

Azevedo, Carla Maria Nunes
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 16/04/1999 PT
Relevância na Pesquisa
48.565737%
Neste trabalho foram desenvolvidos eletrodos modificados e procedimentos para a sua utilização na determinação de diversas espécies químicas de interesse analítico, dentre as quais sulfito, ácido ascórbico, nitrito, dopamina, NADH e peróxido de hidrogênio. Foram realizados estudos envolvendo eletrodos de carbono vítreo modificados com filmes contendo uma única metaloporfirina tetrarrutenada (catiônica) e aplicações analíticas destes sensores associando-os à análise por injeção em fluxo (FIA). Estes eletrodos apresentaram efeitos catalíticos sobre a oxidação de vários analitos, intensificando o sinal de corrente e deslocando seus picos de oxidação para a região de oxidação dos átomos de Ru(II) à Ru(III), sítios ativos das porfirinas. Contudo, para a obtenção de sensores estáveis, foi necessária a utilização de uma elevada concentração do contra-íon trifluorometanossulfonato em solução, prevenindo a gradual solubilização do filme modificador. Tal dificuldade foi contornada recobrindo-se os eletrodos com filmes laminares contendo simultaneamente pares de porfirinas catiônicas e aniônicas. Estes sensores apresentaram ação catalítica igual aos eletrodos recobertos por uma única porfirina...

Determinação de nutrientes e contaminantes Inorgânicos em café solúvel por espectrometria de emissão atômica com plasma de argônio induzido (ICP-AES); Determination of nutrients and inorganic contaminants in soluble coffee by atomic emission spectrometry with inductively-coupled plasma (ICP-AES)

Santos, Eder José dos
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 07/04/1999 PT
Relevância na Pesquisa
48.688145%
A produção industrial do café solúvel brasileiro destina-se, na sua maior parte, ao mercado externo, constituindo-se em um importante ítem de exportação do país. O objetivo do presente trabalho foi o desenvolvimento e aprimoramento de métodos de análise química adequados à investigação de componentes inorgânicos em café solúvel. Inicialmente foi definido o método de mineralização das amostras através da avaliação de 6 procedimentos diferentes, classificados em 3 classes: (I) microondas focalizado; (II) via úmida convencional e (III) sistema sob pressão em frascos de decomposição com tampas (bombas de teflon). As determinações dos nutrientes e contaminantes inorgânicos: Na, K, Mg, Al, P, S, Ca, Mn, Fe, Ni, Cu, Zn, Cd, Sb, Pb, Cr, Sn, As, Se e Hg, após a utilização do procedimento de mineralização que emprega o sistema de microondas focalizado com os reagentes HNO3 e H2O2, foram realizadas por espectrometria de emissão atômica com plasma induzido, ICP-AES (da nomenclatura inglesa Inductively Coupled Plasma-Atomic Emission Spectrometry). Interferências de matriz e/ou espectrais foram detectadas nas determinações de Pb, Cr, Sn, As, Se e Hg. No caso do Sn, optou-se pela correção da radiação de fundo através do software do equipamento...

Quimiometria aplicada à cromatografia líquida multidimensional capilar hifenizada a espectrometria de massas sequencial para proteômica shotgun; Chemometric approach to a capillary multidimensional liquid chromatography coupled to tandem mass spectrometry for shotgun proteomics

Batiston, Weliton Pedro
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 19/02/2015 PT
Relevância na Pesquisa
38.74558%
O sequenciamento genético do DNA humano permitiu maior compreensão da funcionalidade dos seres vivos e principalmente a causa de muitas doenças. Entretanto, os estudos em genética têm se limitado a resolverem os problemas da ciência, e atualmente, a solução para o avanço nessa área tem se atribuído à proteômica. Dessa forma, a pesquisa em química analítica intensificou-se na busca de estratégias melhores para a caracterização de proteomas, em três aspectos principais: preparo de amostra, desenvolvimento da instrumentação analítica e bioinformática. Verifica-se a possibilidade da aplicação de muitas técnicas, atualmente, destaca-se a análise de peptídeos (proteômica shotgun) por cromatografia líquida multidimensional acoplada à espectrometria de massas sequencial (LC/LC-MS/MS), devido à possibilidade de automatização, minimização dos problemas e resultados satisfatórios na análise de amostras biológicas complexas. Portanto, neste trabalho desenvolveu-se um método LC/LC-MS/MS (modalidade on-line column switching) o qual se constitui de coluna trocadora catiônica (homemade), trap de aprisionamento e limpeza, coluna capilar hidrofóbica e separação e detecção por espectrometria de massas sequencial automatizada. Com a proposta de uma instrumentação analítica aperfeiçoada...

Procedimentos analíticos em determinações multi elementares de particulados do aerossol atmosférico para uso em modelo receptor; Analytical procedures in multi elemental determinations of particles of atmospheric aerosol for use in receiver model

Dantas, Elizabeth Sonoda Keiko
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 10/05/1999 PT
Relevância na Pesquisa
48.565737%
O monitoramento da poluição ambiental requer técnicas analíticas confiáveis e efetivas para analisar diferentes níveis de concentração de elementos metálicos. Com este objetivo, foi desenvolvido um método analítico para a determinação de metais presentes (Cd, Co e Cr) no particulado atmosférico, coletados em filtros de celulose, com a introdução direta da amostra sólida utilizando a espectrometria de absorção atômica com forno de grafite (GFAAS). As amostras foram cortadas utilizando um cortador de aço inoxidável com 2 mm de diâmetro e introduzidas no tubo de grafite por meio de pinça de aço inoxidável. Foi investigada a influência do pré - tratamento térmico do tubo com o modificador de matriz Pd/Mg no sinal de absorbância de alguns elementos como Cd, Pb, Sn, Se, Sb, Cr e Co. A calibração foi feita com curva analítica construída com soluções padrão. Concluiu-se que é possível determinar Cd e Co diretamente nas amostras de filtro de celulose com a introdução direta da amostra no forno de grafite. O Cr apresentou interferência, provavelmente do branco, na sua determinação direta por GFAAS. Uma combinação de métodos analíticos diferentes como ICP-AES (espectrometria de emissão atômica com fonte de plasma de argônio induzido); IC (cromatografia de íons)...

Acoplamento de Sistemas de Fluxo a equipamento de espectrofotometria atómica e espectrometria de massa - aplicações em análise elementare em Química Clínica

Lopes, Cristina Manuela Pinto Vieira
Fonte: Faculdade de Farmácia da Universidade do Porto; FFUP Publicador: Faculdade de Farmácia da Universidade do Porto; FFUP
Tipo: Tese de Doutorado Formato: application/pdf
POR
Relevância na Pesquisa
48.848516%
In this dissertation several flow systems are described, which were developed in order to allow performing on line some sample pretreatments that are very common in laboratory analysis. These flow systems were intended to allow an easier application and expansion of the analytical potentialities of atomic spectrophotometry and mass spectrometry in elemental analysis, in Clinical Chemistry. In the Chapter of Introduction to this dissertation a brief description of the interest of the inorganic elemental analysis in Clinical Chemistry context is made, and flow strategies and the instrumental techniques more commonly used for that purpose are described, giving special emphasis to the description of the concepts and basic principles of ICP-MS technique. In the experimental work described in the first three Chapters, atomic spectrophotometric techniques were used and different flow strategies were employed, namely multicommutation and multipumping. Concretely, flow systems capable of adjusting, on line, the concentration of the analyte to the instrumental linear range, either by means of dilution procedures or by means of preconcentration procedures, were assembled. In the first work described involving multipumping, the results obtained in the study on the influence exerted by a pulsed flow...

Reconhecimento de padrões por métodos não supervisionados: explorando procedimentos quimiométricos para tratamento de dados analíticos

Correia,Paulo R. M.; Ferreira,Márcia M. C.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/04/2007 PT
Relevância na Pesquisa
58.23195%
An activity for introducing hierarchical cluster analysis (HCA) and principal component analysis (PCA) during the Instrumental Analytical Chemistry course is presented. The posed problem involves the discrimination of mineral water samples according to their geographical origin. Thirty-seven samples of 9 different brands were considered and the results from the determination of Na, K, Mg, Ca, Sr and Ba were taken into account. Non-supervised methods for pattern recognition were explored to construct a dendrogram, score and loading plots. The devised activity can be adopted for introducing Chemometrics devoted to data handling, stressing its importance in the context of modern Analytical Chemistry.

Experimento utilizando grãos para explorar a calibração em análises químicas

Silvestre,Daniel Menezes; Naozuka,Juliana; Correia,Paulo Rogério Miranda; Nomura,Cassiana Seimi
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2014 PT
Relevância na Pesquisa
38.175835%
The conventional curriculum of Analytical Chemistry undergraduate courses emphasizes the introduction of techniques, methods and procedures used for instrumental analysis. All these concepts must be integrated into a sound conceptual framework to allow students to make appropriate decisions. Method calibration is one of the most critical parameters that has to be grasped since most analytical techniques depend on it for quantitative analysis. The conceptual understanding of calibration is not trivial for undergraduate students. External calibration is widely discussed during instrumental analysis courses. However, the understanding of the limitations of external calibration to correct some systematic errors is not directly derived from laboratory examples. The conceptual understanding of other calibration methods (standard addition, matrix matching, and internal standard) is imperative. The aim of this work is to present a simple experiment using grains (beans, corn and chickpeas) to explore different types of calibration methods.

FOOD QUALITY CONTROL AND AUTHENTICATION THROUGH COUPLING CHEMOMETRICS TO INSTRUMENTAL FINGERPRINTING TECHNIQUES

NESCATELLI, RICCARDO
Fonte: La Sapienza Universidade de Roma Publicador: La Sapienza Universidade de Roma
Tipo: Tese de Doutorado
EN
Relevância na Pesquisa
58.94424%
Given the emphasis that, especially in the last years, has been placed on food quality and safety, the research which constitutes the basis of the present doctoral thesis was focused on the development of analytical methods to verify the authenticity of foods and for their traceability. In this context, attention was mainly posed on the verification of two closely related aspects: i) the chemical characterization of foods, in terms of the assessment of their composition and the determination of their constituents; ii) the identification of the origin of food. To this purpose, on one hand, analytical methods for the determination of biologically, nutritionally and commercially relevant compounds present in different foods were optimized and validated. In particular, a spectroscopic method based on NIR spectroscopy for the determination of some of the indices (water, sugars and hydroxy methylfurfural) required by law to control the quality of honey was developed. An innovative method based on microwave-assisted extraction and subsequent HPLC chromatographic analysis for the determination of three analytes which are considered as quality indices (crocin, picrocrocin and safranal) of saffron was also developed. In collaboration with the University of Santiago de Compostela...

DEVELOPMENT OF ANALYTICAL METHODOLOGIES FOR THE MONITORING OF THE ATMOSPHERIC PARTICULATE MATTER

FARAO, CARMELA
Fonte: La Sapienza Universidade de Roma Publicador: La Sapienza Universidade de Roma
Tipo: Tese de Doutorado
EN
Relevância na Pesquisa
58.509053%
The present research project focused on the development of analytical methodologies for the monitoring of the atmospheric Particulate Matter. Particulate matter (PM) is one of the main pollutants exceeding the ambient standards for air quality in Europe. In Italy, the mass concentration standards are overcome many times per year, mainly due to the unfavourable meteorological conditions (especially in the Po Valley regions) and to the transportation of the air masses coming from the Sahara Desert (Southern and Central regions). The direct and indirect influence of the PM on human health, global climate change and reduced visibility have led to numerous studies in the last past decades, focusing upon its complex composition, toxicology and the source attribution. The particulate matter is constituted by an heterogeneous mix of components, characterized by a variable chemical composition and different chemical-physical properties that greatly influence its deposition and distribution. For these reasons nowadays it is still very difficult to develop efficient abatement strategies to protect both human health and environment. To achieve these specific objectives it is necessary to focus on some issues that are still not resolved, by taking advantage of both the analytical chemistry and the statistical methods. One of the “open” issues is the determination of water content in PM. Water plays an important role in the formation of the secondary species starting from gaseous precursors. It is well known that these species undergo gas-particle equilibria influencing the sampling phase and altering the results of the monitoring campaigns but...

How Well Do Non-traditional Stable Isotope Results Compare Between Different Laboratories: Results from the Interlaboratory Comparison of Boron Isotope Measurements

AGGARWAL Jugdeep; BÖHM Florian; FOSTER Gavin; HALAS Stanislaw; HÖNISCH Bärbel; JIANG Shao-Yong; KOSLER Jan; LIBA Amir; RODUSHKIN Illia; SHEEHAN Ted; SHEN Jason Jiun-San; TONARINI Sonia; XIE Qianli; YOU Chen-Feng; ZHAO Zhi-Qi; ZULEGER Evelyn
Fonte: ROYAL SOC CHEMISTRY Publicador: ROYAL SOC CHEMISTRY
Tipo: Articles in Journals Formato: Online
ENG
Relevância na Pesquisa
38.175835%
In order to address the correct reporting and therefore comparison of isotopic measurements across different instrument types and instrumental techniques a prepared set of synthetic standards was sent to 28 laboratories for boron (B) isotopic analyses. Standards were prepared from enriched and purified isotopic salts to avoid any sample preparation fractionation. The range in uncertainties of the analyses between different instrumental analytical techniques is as large as the differences within an instrumental analytical technique obscuring any systematic offset. We conclude that uncertainties in the measurement of d11B values were often underestimated and a procedure is suggested to allow a better comparison of the different techniques. Two new standards (JABA and JABB) have been quantified and these are available to all laboratories for testing their analyses. The d11B values of these new standards are 10.0& and 23.7&. The results from this exercise impact on the way all isotope measurements are performed and reported. Guidelines are defined to aid the comparison of measurements between different laboratories.; JRC.E.8-Nuclear safeguards and Security

Adaptaci??n Metodol??gica al EEES de la asignatura de T??cnicas Instrumentales del Grado de Farmacia de la Universidad de Barcelona

Bid??n-Chanal Bad??a, A.; Cajal Visa, Y.; Campanera Alsina, J.M.; Egea Gras, M.A.; Gamisans Linares, F.; Garc??a L??pez, M.L.; Girona Brum??s, M.V.; Hern??ndez Borrell, J.; Montero Barrientos, M.T.; Mu??oz Juncosa, M.M.; Aixel?? Prat, J.; Weronski, K.J.
Fonte: Universidad de Granada, Facultad de Farmacia Publicador: Universidad de Granada, Facultad de Farmacia
Tipo: Artigo de Revista Científica
SPA
Relevância na Pesquisa
38.28573%
En el plan de estudios del Grado de Farmacia de la Universidad de Barcelona, la asignatura de T??cnicas Instrumentales se imparte en el cuarto semestre, despu??s de haber cursado F??sica, Fisicoqu??mica y Qu??mica Anal??tica. El equipo docente de la asignatura est?? integrado por once profesores que mediante trabajo colaborativo y adecuada coordinaci??n organizan la docencia de la misma que se distribuye en clases te??ricas y pr??cticas Con el objetivo de adaptar la asignatura a las necesidades del Espacio Europeo de Educaci??n Superior, se distribuy?? en tres Bloques: I, T??cnicas Espectrosc??picas; II, T??cnicas Electroqu??micas y III, T??cnicas de Separaci??n. Las actividades te??rico-pr??cticas se han planificado de manera secuencial. As?? se inicia el ciclo con las clases te??ricas del Bloque I y a continuaci??n de manera paralela se imparten las clases pr??cticas del Bloque I y las clases te??ricas del Bloque II y as?? sucesivamente, de manera que se termina la docencia con las pr??cticas del ??ltimo Bloque. En este proceso adquiere especial relevancia tanto la formaci??n pr??ctica en el laboratorio como el trabajo tutorizado que debe realizar el estudiante. Se realiza un proceso de evaluaci??n continuada te??rico/pr??ctico en cada uno de los Bloques. Se da especial relevancia a la adquisici??n de habilidades y destrezas que permitan una correcta realizaci??n de las pr??cticas de laboratorio...

Metodología analítica verde para determinar Cadmio en sedimentos

Quintas Fernández, Laura
Fonte: Universidade da Corunha Publicador: Universidade da Corunha
Tipo: Trabalho de Conclusão de Curso
SPA
Relevância na Pesquisa
49.079697%
Traballo fin de grao (UDC.CIE). Química. Curso 2014/2015; [Resumen] El trabajo presentado en este Proyecto de Fin de Grado se ha centrado en el desarrollo de un método para determinar cadmio en sedimentos marinos mediante Espectroscopia de Absorción Atómica con Atomización Electrotérmica (ETAAS), basado en la Química Analítica Verde. Para ello se utilizan estrategias que reducen la cantidad de reactivos utilizados y residuos generados así como minimizan el tiempo de análisis. Experimentalmente se optimizaron las condiciones de medida del cadmio en ETAAS para el análisis de extractos ácidos de sedimentos, teniendo como principal objetivo el establecimiento de un programa rápido de temperaturas del horno de grafito. Es decir, eliminando la etapa de calcinación en la cual se descomponen los concomitantes de la matriz. Además, se evalúa la posibilidad de realizar la medida instrumental en ausencia de modificador químico, habitualmente empleado dada la volatilidad del cadmio. En el tratamiento de las muestras se empleó ácido clorhídrico diluido con objeto de evaluar la fracción biodisponible de cadmio en este tipo de muestras. La etapa de extracción se llevó a cabo en tan solo 16 min y se empleó un mínimo volumen de reactivos (1 mL). Se estableció un programa de temperaturas del horno con dos etapas de secado...

Automatic evaluation and data generation for analytical chemistry instrumental analysis exercises

Muñoz de la Peña,Arsenio; Muñoz de la Peña,David; Godoy-Caballero,María P.; González-Gómez,David; Gómez-Estern,Fabio; Sánchez,Carlos
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2014 EN
Relevância na Pesquisa
68.75512%
In general, laboratory activities are costly in terms of time, space, and money. As such, the ability to provide realistically simulated laboratory data that enables students to practice data analysis techniques as a complementary activity would be expected to reduce these costs while opening up very interesting possibilities. In the present work, a novel methodology is presented for design of analytical chemistry instrumental analysis exercises that can be automatically personalized for each student and the results evaluated immediately. The proposed system provides each student with a different set of experimental data generated randomly while satisfying a set of constraints, rather than using data obtained from actual laboratory work. This allows the instructor to provide students with a set of practical problems to complement their regular laboratory work along with the corresponding feedback provided by the system's automatic evaluation process. To this end, the Goodle Grading Management System (GMS), an innovative web-based educational tool for automating the collection and assessment of practical exercises for engineering and scientific courses, was developed. The proposed methodology takes full advantage of the Goodle GMS fusion code architecture. The design of a particular exercise is provided ad hoc by the instructor and requires basic Matlab knowledge. The system has been employed with satisfactory results in several university courses. To demonstrate the automatic evaluation process...

Desenvolvimento de métodos e instrumentação para amostragem e determinação de algumas espécies relacionadas aos processos de acidificação da atmosfera; The development of methods and instrumentation for sampling and determination of certain species related to atmospheric acidification processes

Rocha, Flavio Roberto
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 27/06/2003 PT
Relevância na Pesquisa
48.57528%
A atmosfera, ao lado dos principais gases que a compõe, apresenta em menores concentrações milhares de compostos químicos (orgânicos e inorgânicos) distribuídos nas fases líquidas e gasosa ou no material particulado. Quando esses compostos encontrados no ar apresentam níveis de concentração que os tornam impróprios ou nocivos à saúde humana, aos animais ou vegetais e danosos aos materiais, são considerados poluentes atmosféricos. Neste trabalho, enfatizou-se o estabelecimento de métodos alternativos, eficientes e práticos, para a amostragem de várias espécies que participam dos processos de acidificação da atmosfera, assim corno o desenvolvimento de métodos analíticos baseados em técnicas eletroanalíticas em fluxo como a amperometria e a eletroforese capilar com detecção condutométrica sem contato. Devido a algumas limitações das técnicas de amostragem, explorou-se a alternativa de recorrer a tubos capilares com paredes microporosas, preenchidos com solução adequada à absorção das espécies em pauta, após sua difusão através dos poros da membrana hidrófoba. Assim, construiu-se um coletor por difusão utilizando-se tubo de Teflon®, dentro do qual foi introduzido um feixe de tubos capilares porosos de polipropileno. A união desta técnica de amostragem com a determinação seletiva e quantitativa dos analitos por eletroforese capilar com detecção condutométrica (CE-CCD) possibilitou o desenvolvimento de métodos completos para as seguintes espécies: CH2O coletado em água deionizada...