Página 1 dos resultados de 5058 itens digitais encontrados em 0.003 segundos

Ethanol electro-oxidation over Pt(h k l): Comparative study on the reaction intermediates probed by FTIR and SFG spectroscopies

GOMES, Janaina Fernandes; BUSSON, Bertrand; TADJEDDINE, Abderrahmane; TREMILIOSI-FILHO, Germano
Fonte: PERGAMON-ELSEVIER SCIENCE LTD Publicador: PERGAMON-ELSEVIER SCIENCE LTD
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
36.93377%
We have investigated the adsorbed intermediates of ethanol electro-oxidation at Pt(1 1 1), Pt(1 0 0) and Pt(1 1 0) using FTIR and SFG spectroscopies. Mainly, we focus on the CO formation. The aim of the present work is to compare the responses coming from two different surf, cc probes: a FTIR spectroscopy and SFG spectroscopy. Between 1800cm(-1) and 2300cm(-1), our MR and SFG results are in good agreement. Specifically in the case of the ethanol/Pt(1 1 1) interface, the SFG spectroscopy presents higher sensibility to the interface response compared to the FTIR spectroscopy. (c) 2008 Elsevier Ltd. All rights reserved.

Influence of Fixation Products Used in the Histological Processing in the FTIR Spectra of Lung Cells

Pereira, Thiago Martini; Dagli, Maria Lucia Zaidan; Mennecier, Gregory; Zezell, Denise Maria
Fonte: HINDAWI PUBLISHING CORPORATION; NEW YORK Publicador: HINDAWI PUBLISHING CORPORATION; NEW YORK
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
36.93377%
The aim of the present study is to evaluate the differences on FTIR spectra of the normal lung cell (noncancerous mice lung epithelial cell line e10) due to different fixation protocols for histological processing. The results shown that formalin and methacarn (normally used in fixation) did cause many changes on the FTIR spectra of mice lung cells e10, mainly in the organic compounds (800-1800 cm(-1)) in lipids, DNA, and proteins, and the alcohol 70% fixation protocol caused almost no changes on the FTIR spectra compared to unfixed cells spectra (in PBS). It can be concluded that histological processing with alcohol 70% fixation protocol can be used in the FTIR study of mice lung cell line e10.; FAPESP-CEPID [05/51689-2]; CNPq-INFO [573916/2008]; CNPq [143166/2009-3]

Determinação de surfactantes e água em formulações de sabonetes líquidos e shampoos por infravermelho por transformada de Fourier (FTIR) utilizando a técnica de reflectância total atenuada (ATR); Determination of surfactants and water in formulations of shampoos and liquid soaps by fourier transformed infrared (FTIR) using the tecnique of attenuated total reflectance (ATR)

Carolei, Luciano
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 10/08/2005 PT
Relevância na Pesquisa
36.980933%
Demonstrou-se pela primeira vez que é possível determinar surfactantes e água em formulações de Sabonetes Líquidos (SL) e Shampoos (SH), direta e simultaneamente pela técnica de infravermelho por transformada de Fourier (FTIR) acoplada à uma cela de reflectância total atenuada (ATR). Tradicionalmente, a principal aplicação do infravermelho médio (2,50 - 15,0 µm) é a identificação de compostos orgânicos. O desenvolvimento de novos acessórios, principalmente de ATR, os avanços na área de microinformática e de métodos quimiométricos, vem viabilizando as análises quantitativas rápidas com excelentes resultados mesmo em meio aquoso. A determinação simultânea de surfactantes em formulações por FTIR-ATR é investigada em detalhes nesta tese. Dentre os surfactantes utilizados, o Lauril Éter Sulfato de Sódio (LESS) e a Cocoamidopropil Betaína (CAPB) são comuns em ambas as formulações, sendo a Coco Dietanolamida (CDEA) empregada em shampoo e o Alquilpoliglicosídeo (APG) em sabonete líquido. Espectros de absorbância de amostras padrão e de verificação foram adquiridos na região do infravermelho médio (800-1600 e 1900-3000 cm-I). Para a regressão de mínimos quadrados clássicos (CLSR), selecionou-se 200 números de onda...

Hidroxiapatita sintética nanoestruturada e esmalte dental aquecidos e irradiados por laser de Er, Cr: YSGG: caracterização por FTIR e por DRX; NANOSTRUCTURED SYNTHETIC HYDROXYAPATITE AND DENTAL ENAMEL HEATED E IRRADIATED BY ER,CR:YSGG. CHARACTERIZED BY FTIR AND XRD.

Rabelo Neto, José da Silva
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 18/05/2009 PT
Relevância na Pesquisa
36.93377%
Este estudo procurou avaliar as mudanças físicas e/ou químicas que ocorrem na hidroxiapatita (HAP) sintética e na presente no esmalte dental sob ação de aquecimento térmico em forno ou irradiação com o laser de Er,Cr:YSGG (2,79 m). Busca-se obter variações em sua estrutura a fim de torná-los mais resistentes à desmineralização, visando e prevenir a formação da cárie dental. A HAP sintética foi produzida pela reação das soluções de Ca(NO3) e (NH4)2HPO4 com controle de temperatura e pH. O esmalte foi coletado do dentes bovinos e triturados. As amostras em pó de HAP sintética e esmalte foram submetidas a aquecimento térmico em forno nas temperaturas de 200 °C, 400 °C, 600 °C, 800 °C e 1000 °C. Foram feitas irradiações laser com 5,79 J/cm2, 7,65 J/cm2, 10,55 e 13,84 J/cm2 para a HAP sintética e de 7,53 J/cm2, 10,95 J/cm2 e 13,74 J/cm2 para o esmalte. As amostras foram avaliadas por difração de raios-X(DRX) para análise das fases cristalográficas presentes e análise pelo método de Rietveld para comprovação destas fases cristalográficas e determinação de respectivas proporções no material. Foram obtidos também as variações de parâmetros de rede da cela unitária (eixo-a, eixo-c e volume)...

Estudo in-vitro dos efeitos do laser de Er,Cr:YSGG em tecido ósseo por espectroscopia ATR-FTIR; Study in vitro of Er,Cr:YSGG laser effects in bone tissue by ATR-FTIR spectroscopy

Benetti, Carolina
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 23/04/2010 PT
Relevância na Pesquisa
37.017847%
O laser tem se mostrado eficaz no auxílio ao profissional de saúde, sendo extensivamente utilizado em procedimentos médicos e odontológicos nas ultimas décadas. Em particular, os lasers de alta intensidade emissores no infravermelho possuem grande potencial para corte de tecidos biológicos mineralizados, visto que são bastante absorvidos pela hidroxiapatita e água, principais componentes desses tecidos. Em comparação aos instrumentos mecânicos, o laser apresenta uma série de vantagens no corte de tecidos, com possibilidade de menor dano ao tecido remanescente e melhor hemostasia. Entretanto, para uma aplicação eficiente e segura é necessário conhecer os efeitos que a irradiação laser causa ao tecido. A técnica de espectroscopia no Infravermelho por Transformada de Fourier (FTIR) é bastante utilizada no estudo de materiais orgânicos, pois além de permitir a identificação de componentes, possibilita uma análise semiquantitativa. Este trabalho tem como objetivos estabelecer a técnica de ATR-FTIR para caracterização do tecido ósseo natural e irradiado, e verificar as eventuais mudanças químicas e estruturais causadas pela irradiação laser. Primeiramente, foram determinadas as melhores condições instrumentais para a obtenção dos espectros de amostras de osso. Posteriormente foram analisadas as amostras de osso natural e irradiado com o laser de Er...

Diagnóstico de lesões da tireóide pela espectroscopia de absorção no infravermelho por transformada de Fourier-FTIR; Thyroid lesions diagnosis by fourier transformed infrared absorption spectroscopy (FTIR)

Albero, Felipe Guimarães
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 11/12/2009 PT
Relevância na Pesquisa
37.137324%
Os nódulos de tireóide constituem patologia comum, com uma incidência entre 4- 7% na população brasileira. Embora a punção aspirativa por agulha fina (PAAF) seja um método com boa sensibilidade, a discriminação entre lesões benignas e neoplasias malignas não é possível em todos os casos, permitindo a incidência de diagnósticos falsos-positivos, o que conduz a tireoideotectomia pelo risco de carcinoma. O escopo deste estudo foi verificar se a espectroscopia de absorção no infravermelho por transformada de Fourier (FTIR) pode contribuir no diagnóstico diferencial entre neoplasias malignas e benignas de tecidos e aspirados. Amostras de PAAF, homogenatos e tecidos de nódulos de tireóide com o diagnóstico histopatológico foram obtidos e preparados para análise espectroscópica por FTIR. As punções e homogenatos foram medidas por -FTIR (entre 950 1750 cm-1, com resolução de 4 cm-1 e 120 varreduras). As amostras de tecido foram analisadas diretamente pela técnica de ATR-FTIR, com resolução de 2 cm-1, 60 varreduras, região entre 950 1750 cm-1.. Todos os espectros foram corrigidos pela linha base e normalizados pela área sob a banda das amidas (1550-1640 cm-1) de modo a minimizar as variações de homogeneidade das amostras. Os espectros foram então convertidos em segundas derivadas usando-se o filtro de Savitzk-Golay com 13 pontos na janela. A variância de Ward e distância euclidiana foram usadas para se processar a análise de clusters. As amostras de PAAF revelaram um complexo padrão espectral. Todas as amostras mostraram alguns aglomerados de células ou grande concentração de hormônios...

Ablação de pele queimada com laser de pulsos ultra-curtos para promoção da cicatrização. Avaliação por tomografia por coerência óptica, histologia, μATR-FTIR e microscopia não-linear; Ablation of burned skin with ultra-short pulses laser to promote healing. Evaluation by optical coherence tomography, histology, μATR-FTIR and Nonlinear Microscopy

Santos, Moisés Oliveira dos
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 10/07/2012 PT
Relevância na Pesquisa
36.93377%
As queimaduras causam alterações na estrutura anatômica da pele associadas a trauma. As queimaduras podem ser classificadas em lesões de primeiro, segundo e terceiro grau. As queimaduras de terceiro grau têm sido grande foco de pesquisas em busca de tratamentos mais conservadores e de maior rapidez no reparo para um resultado funcional e estético satisfatório. O tratamento convencional consiste no uso de medicamentos tópicos e no enxerto de pele natural ou sintética. Alternativamente, a terapia laser utiliza o processo de ablação para remoção do tecido queimado necrosado, devido ao não contato mecânico, à rapidez na aplicação e alcance a áreas de difícil acesso. Deste modo, a proposta deste estudo é avaliar a viabilidade de utilizar lasers de femtossegundos de altíssima intensidade como coadjuvante no tratamento de pacientes queimados. Para o estudo, foram utilizados 25 ratos da raça Wistar, divididos em grupos de 5 animais: grupos pele sadia, pele queimada, dois tipos de tratamento (desbridamento cirúrgico ou ablação a laser de femtossegundos) e em quatro tempos de acompanhamento do processo cicatricial. Três regiões do dorso dos animais foram expostas a fonte de vapor causando queimadura de terceiro grau. No terceiro dia após a queimadura...

Avaliação in vitro dos efeitos da radiação ionizante em tecido ósseo bovino por espectroscopia ATR-FTIR e análise dinâmico-mecânica; In vitro evaluation of ionizing radiation effects in boné tissue by FTIR spectroscopy and dynamic mechanical analysis

Veloso, Marcelo Noronha
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 04/11/2013 PT
Relevância na Pesquisa
37.017847%
A radiação ionizante de fontes de radiação gama ou geradores de raios-x é frequentemente utilizada na ciência médica, como em exames de radiodiagnóstico, radioterapia e esterilização de aloenxertos. A radiação ionizante é capaz de quebrar cadeias polipeptidicas e provocar a libertação de radicais livres, pela radiólise de moléculas de água. A radiação ionizante interage também com o material orgânico a nível molecular, podendo alterar as suas propriedades mecânicas. No caso específico do tecido ósseo, estudos reportam que a radiação ionizante induz alterações nas moléculas de colágeno e reduzem a densidade de ligações cruzadas intermoleculares. O objetivo deste estudo foi verificar as alterações promovidas por diferentes doses de radiação ionizante no tecido ósseo utilizando a técnica de Espectroscopia Transformada de Fourier com Reflexão Total Atenuada (ATR-FTIR), e também a análise dinâmico-mecânica. Amostras de osso bovino foram irradiadas usando irradiador de Cobalto-60, com cinco doses diferentes: 0,01 kGy, 0,1 kGy, 1 kGy, 15 kGy e 75 kGy. Para estudar os efeitos da radiação ionizante sobre a estrutura química do osso foram avaliadas a relação material orgânico por material inorgânico...

Estudo da reparação óssea por espectroscopia ATR-FTIR após remoção de fragmento da região mandibular com laser de Er,Cr:YSGG ou broca multilaminada; Study of bone repair by ATR - FTIR spectroscopy technique after the removal of a fragment from jaw region using Er,Cr:YSGG laser or drill

Benetti, Carolina
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 06/08/2014 PT
Relevância na Pesquisa
37.16752%
A reparação óssea é um fator crítico para o sucesso de procedimentos odontológicos e ortopédicos que necessitem do corte ósseo, sendo desejado que esta ocorra de forma rápida e eficaz. Uma maior compreensão da reparação óssea em um nível estrutural e molecular é o primeiro passo para o desenvolvimento de técnicas de corte e terapias regenerativas. Neste contexto, a técnica de FTIR possibilita obter informações sobre a estrutura e composição de tecido mineralizado. O principal objetivo deste projeto foi verificar a eficácia da espectroscopia FTIR na caracterização de diferentes estágios da reparação óssea após a realização de remoção óssea utilizando duas ferramentas de corte: o laser de Er,Cr:YSGG ou uma broca carbide multilaminada, em alta rotação. Foi realizada a remoção de dois fragmentos ósseos da mandíbula de 30 coelhos, e o processo de reparação óssea foi estudado imediatamente, 3, 7, 15, 21, e 28 dias após o procedimento cirúrgico. Utilizou-se a técnica de espectroscopia FTIR para a aquisição das imagens espectrais dos diferentes estágios de reparação, e foi analisada a proporção entre os compostos do tecido utilizando as bandas de amidas, colágeno, carbonato e fosfato dos espectros de absorção. Também foi realizada a análise histológica dos mesmos estágios de reparação estudados. A técnica de espectroscopia FTIR se mostrou eficaz na caracterização do processo de reparação óssea. Observou-se uma tendência de aumento na proporção de compostos orgânicos até o Grupo 15D...

Attenuated total reflectance with fourier transform infrared spectroscopy (ATR/FTIR) and different PLS algorithms for simultaneous determination of clavulanic acid and amoxicillin in powder pharmaceutical formulation

Müller, Aline Lima Hermes; Flores, Erico Marlon de Moraes; Müller, Edson Irineu; Silva, Fabiana Ernestina Barcellos da; Ferrao, Marco Flores
Fonte: Universidade Federal do Rio Grande do Sul Publicador: Universidade Federal do Rio Grande do Sul
Tipo: Artigo de Revista Científica Formato: application/pdf
ENG
Relevância na Pesquisa
36.980933%
Um método para determinação simultânea de ácido clavulânico (CA) e amoxicilina (AMO) foi desenvolvido utilizando a técnica de espectroscopia no infravermelho médio com transformada de Fourier acoplada ao acessório de reflexão total atenuada (ATR/FTIR). Utilizaram-se 27 e 8 amostras para os conjuntos de calibração e previsão, respectivamente. Os modelos de calibração foram desenvolvidos utilizando os algoritmos por mínimos quadrados parciais (PLS), PLS por intervalo (iPLS), PLS por sinergismo (siPLS) e PLS por exclusão (biPLS). Os melhores modelos foram aqueles que utilizaram o algoritmo biPLS. Obtiveram-se erro padrão relativo de previsão (RSEP) de 3,8 e 5,1% para CA e AMO, respectivamente. Os resultados obtidos pela metodologia proposta foram comparados com os obtidos por cromatografia líquida de alta eficiência (HPLC) e nenhuma diferença significativa foi observada. O método proposto utilizando ATR/FTIR associado a métodos de análise multivariados foi satisfatório para determinação de CA e AMO em produtos farmacêuticos.; A method for simultaneous determination of clavulanic acid (CA) and amoxicillin (AMO) was developed using Fourier transform mid infrared technique coupled with attenuated total reflectance (ATR/FTIR) accessory. 27 samples were used as calibration set and 8 samples were used for prediction set. Calibration models were developed using partial least squares (PLS)...

Characterization of dextrin hydrogels by FTIR spectroscopy and solid state NMR spectroscopy

Garcia, Helga; Barros, António; Gonçalves, Catarina; Gama, F. M.; Gil, Ana M.
Fonte: Elsevier Ltd. Publicador: Elsevier Ltd.
Tipo: Artigo de Revista Científica
Publicado em /07/2008 ENG
Relevância na Pesquisa
36.980933%
Fourier transform infrared (FTIR) and 13C solid state nuclear magnetic resonance (NMR) spectroscopy were used to study dextrin structural changes occurring upon hydrogel formation by vinyl acrylate (VA) grafting and subsequent free radical polymerization. The degrees of VA substitution (DS) and polymerization (DP) were quantified up to 40%VA by FTIR intensity measurements and partial least squares (PLS)/FTIR, the latter being a faster and less error-prone method. Above 40%VA, both parameters are underestimated by FTIR. A spin counting NMR experiment showed high carbon observabilities for hydrogels and improved PLS/NMR models were achieved for DS and DP determination. Alternative NMR integration methods are hindered by the broad VA peaks and need for area correction, due to their CP dynamics. NMR changes in C1 profile showed that a single helical conformation predominates at lower %VA, being replaced by disordered conformations as %VA increases. Furthermore, a correlation FTIR/NMR study indicated that ring conformations are significantly affected in hydrogels, compared to unpolymerized dextrin.; Fundação para a Ciência e a Tecnologia (FCT)

Caracterização de tintas alquídicas por THM-GC-MS, FTIR in situ e FTIR-μS: estudo da obra "Francisco de Assis" de Álvaro Lapa

Rodrigues, Denis Manuel de Castro Fernandes dos Santos, 1989-
Fonte: Universidade de Lisboa Publicador: Universidade de Lisboa
Tipo: Dissertação de Mestrado
Publicado em //2012 POR
Relevância na Pesquisa
36.980933%
Tese de mestrado em Química Tecnológica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2012; O objetivo deste trabalho consistiu na caracterização de tintas alquídicas de qualidade artística de uma marca comercial, identificando-se as suas cargas, pigmentos, e acima de tudo o tipo de resina alquídica, ao mesmo tempo que se pretendia estudar o efeito que cada pigmento tem no envelhecimento geral da tinta. Para tal, recorreu-se a diversas técnicas analíticas, nomeadamente FTIR in situ, FTIR-μS e THM-GC-MS, assim como a ensaios de colorimetria. No fim do trabalho, realizou-se ainda o estudo da obra “Francisco de Assis”, de Álvaro Lapa, com o intuito de se aplicarem essas técnicas analíticas, assim como os conhecimentos adquiridos na caracterização das tintas alquídicas a um caso real. As técnicas analíticas utilizadas permitiram caracterizar todas as tintas analisadas, identificando-as como resinas alquídicas modificadas por óleo (umas curtas e outras médias em óleo), maioritariamente formadas por anidrido ftálico e pentaritritol, o único óleo encontrado confirmado na resina é o óleo de rícino hidrogenado, contudo a sua utilização comum como aditivo, não permite dizer se é este o óleo utilizado na resina ou se será haverá ainda outro óleo. Foi ainda possível identificar os pigmentos presentes. Após 8 semanas de fotoenvelhecimento...

FTIR, a powerful technique in organic coatings failure diagnosis

Costa, M. Rosário; Santos, M. Teresa; Diamantino, Teresa C.
Fonte: Laboratório Nacional de Energia e Geologia Publicador: Laboratório Nacional de Energia e Geologia
Tipo: Artigo de Revista Científica
Publicado em //2011 ENG
Relevância na Pesquisa
36.980933%
FTIR spectrometry (Fourier Transform Infrared) is an instrumental technique of analysis that presents significant advantages on the dispersive traditional system, such as the increase of the relation signal-noise, the capacity of getting absorption spectra of low energy and therefore, bands of absorption of weak intensity. This technique is widely used in the study of resin characterization and evaluation of polymeric materials as well as degradation when polymers and coatings are exposed to various conditions of service, or still in the analysis and diagnosis of defects that occur during the application or production process. Techniques connected to the FTIR have appeared such as the photoacoustic (PAS-FTIR), the microscopy (MCT-FTIR) and the attenuated total reflectance (ATR), which allows to analysis of weekly transparent and dark samples without removal of coatings from the substrates. The choice of the technique to use depends on the morphology of the surfaces to analyze and the type of failure (lack of adhesion, contamination, aging degradation, etc). This work illustrates the application of FTIR and associated techniques to identify causes of diverse types of defects in applied organic coatings on polymeric materials.

Aplicação de metodologias FTIR de transmissão e fotoacústica à caracterização de materiais altamente energéticos: parte II

Mattos,Elizabeth da Costa; Viganó,Itamar; Dutra,Rita de Cássia Lazzarini; Diniz,Milton Faria; Iha,Koshun
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/09/2002 PT
Relevância na Pesquisa
36.93377%
Materials obtained during the synthesis of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) were characterized by Fourier transform infrared (FTIR) transmission spectroscopy and/or Fourier transform infrared photoacoustic spectroscopy (FTIR-PAS). By these techniques the spectrometric alterations that occurred during the process were observed. The characterized species during the synthesis of HMX were alpha-HMX, beta-HMX, hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and HMX/RDX mixtures. The FTIR-PAS was verified to be a promising technique of great usefulness of the characterization of highly energetic materials because it is fast, simple and requires no sample preparation unlike Fourier transform infrared transmission technique (KBr pellet). The FTIR-PAS analysis showed that with small sample quantity is possible to distinguish between thealpha-HMX and beta-HMX and to detect even in a qualitative way different HMX / RDX ratios.

Fourier Transform Infrared Spectroscopy (FTIR) for MUN analysis in normal and adulterated Milk

Oliveira,M.C.P.P.; Silva,N.M.A.; Bastos,L.P.F.; Fonseca,L.M.; Cerqueira,M.M.O.P.; Leite,M.O.; Conrrado,R.S.
Fonte: Universidade Federal de Minas Gerais, Escola de Veterinária Publicador: Universidade Federal de Minas Gerais, Escola de Veterinária
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/10/2012 EN
Relevância na Pesquisa
37.017847%
The objective of this study was to evaluate the CombiScope FTIR equipment based on Fourier Transform Infrared methodology (FTIR), to assess the content of milk urea nitrogen (MUN) in Brazil. Repeatability and reproducibility of CombiScopeTM FTIR (Delta Instruments), and comparison with an enzymatic automated method (Chemspec® 150; Bentley Instruments) were tested to measure raw milk urea nitrogen (MUN). Additionally, MUN levels stability after storage of raw milk samples at 4ºC, and 20ºC for up to 15 days, and capability and precision to detect extraneous urea added as an adulterant to the milk were evaluated by FTIR equipment. There was a high correlation coefficient for the analysis of MUN by FTIR equipment, when compared with the automated enzymatic method, with no significant difference between both. MUN concentration in raw milk remained stable at temperatures of 4ºC for up to 15 days of storage, but after 3 days of storage at 20ºC there was an increase in the MUN levels. The CombiScope FTIR equipment proved to be a reliable method for analysis of MUN content in raw milk. However, results for MUN were not linear with the amount of extraneous urea added to raw milk, having a significant difference for samples when 40mg/dL of urea was added to milk.

Monitorando a degradação da poliamida 11 (PA-11) via espectroscopia na região do infravermelho médio com transformada de fourier (FTIR)

Domingos,Eloilson; Pereira,Thieres M. C.; Castro,Eustáquio V. R. de; Romão,Wanderson; Sena,Geovane L. de; Guimarães,Regina C. L.
Fonte: Associação Brasileira de Polímeros Publicador: Associação Brasileira de Polímeros
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2013 PT
Relevância na Pesquisa
36.93377%
O potencial da técnica de espectroscopia de infravermelho com transformada de Fourier e acessório de reflexão total atenuada (FTIR-ATR) foi avaliado para o monitoramento da degradação da poliamida 11 (PA-11) usada em dutos flexíveis. As amostras foram submetidas a envelhecimento em reatores com pressão controlada e atmosfera inerte. Os corpos de prova foram imersos em água deionizada (pH 7), nas temperaturas de 110, 120 e 140 ºC por um período de até 50 dias. A técnica recomendada para monitoramento da degradação da PA-11 é a viscosimetria, através de medidas da viscosidade inerente corrigida (VIC) e a análise termogravimétrica (TGA). O comportamento observado para a VIC e TGA durante o envelhecimento possibilitou a construção de modelos que correlacionam com a técnica de FTIR-ATR. A partir dos resultados de FTIR-ATR, a variação na intensidade da banda atribuída à fase amorfa, 1161 cm-1, possibilitou o monitoramento do envelhecimento quando associamos a técnica a modelos quimiométricos como o de regressão dos mínimos quadrados parciais, PLS. Portanto, a técnica FTIR-ATR pode ser uma nova alternativa no monitoramento da degradação hidrolítica da PA-11, eliminando assim o uso de solventes orgânicos tóxicos e reduzindo...

Combined Micro-Fourier Transform Infrared (FTIR) Spectroscopy and Micro-Raman Spectroscopy of Proterozoic Acritarchs: A New Approach to Palaeobiology

Walter, Malcolm R.; Knoll, Andrew; Javaux, Emmanuelle J.; Marshall, Craig P.
Fonte: Elsevier Publicador: Elsevier
EN_US
Relevância na Pesquisa
36.980933%
Micro-scale analytical techniques permit correlation of chemistry with morphology of individual Proterozoic acritarchs (organic-walled microfossils), and thus provide new approaches for elucidating their biological affinities. A combination of micro-Fourier transform infrared (FTIR) spectroscopy and laser micro-Raman spectroscopy was used to investigate the organic structure and composition of individual acritarchs. Well preserved Neoproterozoic acritarchs from the Tanana Formation, Australia (ca. 590-565 Ma), and Mesoproterozoic acritarchs from the Roper Group (1.5-1.4 Ga), Australia, and Ruyang Group, China (1.4-1.3 Ga, age poorly resolved but certainly > 1000 Ma and < 1625 Ma) have thermal maturities that range from immature to oil window. FTIR spectra of Tanarium conoideum from the Tanana Formation contain intense aliphatic C-H stretching bands in the 2900 cm[super]-1 region relative to the C=C aromatic ring stretching band at 1600 cm[super]-1. This FTIR spectrum is consistent with the FTIR spectra obtained from algaenans isolated from extant chlorophyte and eustigmatophyte microalgae. FTIR spectra of Leiosphaeridia sp. from the Tanana Formation contain a less intense aliphatic C-H stretching band relative to the C=C aromatic ring stretching band. By comparison...

A hybrid thermal video and FTIR spectrometer system for rapidly locating and characterizing gas leaks

Williams, David; Wadsworth, Winthrop; Salvaggio, Carl; Messinger, David
Fonte: The International Society for Optical Engineering (SPIE) Publicador: The International Society for Optical Engineering (SPIE)
Tipo: Artigo de Revista Científica
EN_US
Relevância na Pesquisa
36.93377%
Undiscovered gas leaks, known as fugitive emissions, in chemical plants and refinery operations can impact regional air quality and present a loss of product for industry. Surveying a facility for potential gas leaks can be a daunting task. Industrial leak detection and repair programs can be expensive to administer. An efficient, accurate and cost effective method for detecting and quantifying gas leaks would both save industries money by identifying production losses and improve regional air quality. Specialized thermal video systems have proven effective in rapidly locating gas leaks. These systems, however, do not have the spectral resolution for compound identification. Passive FTIR spectrometers can be used for gas compound identification, but using these systems for facility surveys is problematic due to their small field of view. A hybrid approach has been developed that utilizes the thermal video system to locate gas plumes using real time visualization of the leaks, coupled with the high spectral resolution FTIR spectrometer for compound identification and quantification. The prototype hybrid video/spectrometer system uses a sterling cooled thermal camera, operating in the MWIR (3-5 µm) with an additional notch filter set at around 3.4 µm...

FTIR, a powerful technique in organic coatings failure diagnosis

Costa, Maria do Rosário; Santos, M. Teresa; Diamantino, Teresa C.
Fonte: Laboratório Nacional de Energia e Geologia Publicador: Laboratório Nacional de Energia e Geologia
Tipo: Conferência ou Objeto de Conferência
Publicado em 08/09/2009 ENG
Relevância na Pesquisa
37.017847%
FTIR spectrometry (Fourier Transform Infrared) is an instrumental technique of analysis that presents significant advantages on the dispersive traditional system, such as the increase of the relation signalnoise, the capacity of getting absorption spectra of low energy and therefore, bands of absorption of weak intensity. This technique is widely used in study, resin characterization and evaluation of polymeric materials as well as of its degradation when exposed to the most varied conditions of service, or still in the analysis and diagnosis of defects that occur during the application or production process. Techniques connected to the FTIR had more recently appeared as the photoacoustic (PAS-FTIR), the microscopy (MCT-FTIR) and the attenuated total reflectance (ATR), which allow to analyze weekly transparent and dark samples without removal of coatings from the substrates. The choice of the technique to use depends on the morphology of the surfaces to analyze and the type of failure in cause (lack of adhesion, contamination, aging degradation, etc). In this work the application of FTIR and techniques associates to the identification of the causes that had originated diverse types of defect in applied organic coatings on polymeric materials is presented. Key words: FTIR...

Proficiency Test on Ftir Wine Analysis

Moreira,J. L.; Marcos,A. M.; Barros,P.
Fonte: INIAV - DOIS PORTOS (Ex-Estação Vitivinícola Nacional) Publicador: INIAV - DOIS PORTOS (Ex-Estação Vitivinícola Nacional)
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2002 EN
Relevância na Pesquisa
36.980933%
The FTIR (Fourier Transform Infrared) technology has recently become one of the greatest improvements in the routine work of a wine analysis laboratory. In Portugal a workgroup of laboratories equipped with FTIR wine analysers has been created in order to optimise this methodology. One of the most important tasks of this workgroup was to carry out a proficiency test for FTIR analysers. This test consisted in the analysis of the same sample by all the participants, using a FTIR wine analyser provided with the same analytical calibration and using the same procedure. The results obtained presented good reproducibility in what the most relevant parameters are concerned. This proficiency test enables a more effective quality control of the FTIR results of each laboratory and became an important tool to detect several malfunctions in the equipments of the participants.