Página 1 dos resultados de 1030 itens digitais encontrados em 0.002 segundos

Avaliação  dosimétrica de detectores semicondutores para aplicação na dosimetria e microdosimetria em reatores nucleares e instalações de radiocirugia; Dosimetric evaluation of semiconductor detectors for application in neutron dosimetry and microdosimetry in nuclear reactor and radiosurgical facilities

Cárdenas, José Patricio Náhuel
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 19/04/2010 PT
Relevância na Pesquisa
37.169614%
Este trabalho tem como objetivo a avaliação dosimétrica de componentes semicondutores (detectores Barreira de Superfície e fotodiodos PIN) para aplicação em medições de dose equivalente em campos de baixo fluxo de nêutrons (rápidos e térmicos), utilizando uma fonte de AmBe de alto fluxo, a instalação de Neutrongrafia do reator IEA-R1 (fluxos térmicos/epitérmicos) e fluxo de nêutrons rápidos do núcleo do reator IPEN/MB-01 (UCRI Unidade Crítica). Para a detecção de nêutrons (térmicos, epitérmicos e rápidos) foram usados componentes moderadores e conversores (parafina, boro e polietileno). Os fluxos resultantes da moderação e conversão foram utilizados para a irradiação de componentes semicondutores (SSB - Barreira de Superfície e fotodiodos). Foi utilizado também um conversor misto constituído de uma folha de polietileno borado (marca Kodak). O método de simulação por Monte Carlo foi utilizado para avaliar de forma analítica a espessura ótima da parafina. O resultado obtido foi similar ao verificado experimentalmente e serviu para avaliar o fluxo de nêutrons emergentes do moderador (parafina). Da mesma forma, através de simulação, foi avaliado também o fluxo de nêutrons rápidos que atinge o conversor de polietileno que cobre a face sensível dos semicondutores. O nível de radiação gama foi avaliado cobrindo o detector por inteiro com uma folha de cádmio de 1 mm de espessura. O reator IPEN/MB-01 foi usado para avaliar a resposta dos detectores para nêutrons rápidos de alto fluxo. Os resultados...

Desenvolvimento de um código computacional aberto de análise quantitativa para determinação de radionuclídeos por espectrometria gama com detectores semicondutores; Development of an open source software of quantitative analysis for radionuclide determination by gamma-ray spectrometry using semiconductor detectors

Máduar, Marcelo Francis
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 26/05/2010 PT
Relevância na Pesquisa
37.01464%
A quantificação da atividade de radionuclídeos emissores de raios gama em amostras medidas por espectrometria gama com detectores HPGe depende da análise dos fotopicos presentes no espectro, especialmente da determinação exata das suas áreas líquidas. Tal análise é geralmente realizada com o auxílio de ferramentas de software proprietário. Este trabalho apresenta uma metodologia, descrição de algoritmos e um aplicativo de código aberto, denominado OpenGamma, para a busca e análise de fotopicos a fim de se obter seus parâmetros relevantes e as atividades dos radionuclídeos na amostra. A implementação computacional é distribuída sob licença aberta para o código principal e com o uso de pacotes de software aberto para o projeto da interface e para bibliotecas matemáticas. O procedimento para a busca de picos é realizado em três etapas. Primeiramente, executa-se uma pesquisa preliminar com o método da segunda diferença, que consiste na geração de um espectro derivado para a busca de picos candidatos. Na segunda etapa, calculam-se as larguras experimentais dos picos, dos quais escolhem-se aqueles bem formados e isolados para a obtenção da função de ajuste da largura vs. canal, por meio do método de Levenberg-Marquardt para ajustes não-lineares. Por fim...

Desenvolvimento de cristais baseados em iodeto de Césio para aplicação como detectores de radiação; Development of crystals based in cesium iodide for application as radiation detectors

Pereira, Maria da Conceição Costa
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 07/06/2006 PT
Relevância na Pesquisa
37.01464%
Cintiladores inorgânicos com tempo de decaimento de luminescência rápido, densidade alta e boa produção de luz têm sido objeto de estudos para aplicações em física nuclear, física de energias altas, tomografia nuclear e outros campos da ciência e da engenharia. Cristais de cintilação baseados em iodeto de césio (Csl) são materiais que apresentam higroscopia relativamente baixa, número atômico alto, fácil manuseio e custo baixo, características que favorecem o seu uso como detectores de radiação. Neste trabalho descreve-se a obtenção de cristais Csl puro, Csl:Br e Csl:Pb, utilizando-se a técnica de Bridgman. A concentração do elemento dopante bromo (Br) foi estudada no intervalo de 1,5x10-1 M a 10-2 M e o elemento chumbo (Pb) no intervalo de 10-2 M a 5x10-4 M. Para avaliar os cintiladores desenvolvidos foram efetuadas medidas sistemáticas de emissão de luminescência e tempo de decaimento de luminescência para a radiação gama, ensaios de transmitância óptica, ensaios de microdureza Vickers, determinações da distribuição dos dopantes ao longo dos cristais crescidos e análise da resposta dos cristais à radiação gama no intervalo de energia de 350 keV a 1330 keV e partículas alfa provenientes de fonte de 241Am com energia de 5...

Função resposta de detectores semicondutores, Ge e Si(Li); Response function of semiconductor detectors, Ge and Si (Li)

Chávez, Juan Yury Zevallos
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 14/08/2003 PT
Relevância na Pesquisa
37.169614%
A Função Resposta (FR) foi obtida para os detectores semicondutores Ge e Si(Li) usando o método semiempírico. A FR foi calculada para cinco detectores, 4 de HpGe, de volumes ativos 89 cm3, 50 cm3, 8 cm3 e 5 cm3, e um detector de Si(Li) de 0,143 cm3 de volume ativo. O intervalo de energia estudado dói de 6 keV até 1,5 MeV. Dois tipos de estudos foram realizados neste trabalho. O primeiro estudo foi a dependência da FR com a geometria de detecção. Este estudo envolveu o cálculo da FR para uma geometria denominada simples e a extrapolação da FR calculada. A extração da FR foi realizada para analisar tanto espectros obtidos com uma geometria com blindagem, como espectros onde a distância fonte-detector foi modificada. O segundo estudo foi a dependência da FR com a eletrônica de detecção. Este estudo foi realizado variando-se o tempo de formação de pulso na eletrônica de detecção. O objetivo foi a de verificar a existência ou ausência do efeito do déficit balístico na resolução do detector. Este efeito não foi observado. As componentes da FR que descrevem a região de absorção total da energia dos fótons incidentes, bem como as componentes que descrevem a absorção parcial dessa energia foram estudadas. Particularmente...

Detectores RPC para experimentos de raios cósmicos

Anastasia Guidi
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 15/02/2000 PT
Relevância na Pesquisa
37.169614%
Apresentamos um estudo sobre detectores a gás do tipo Resistive Plate Counter - RPC e sobre a viabilidade de sua utilização em experimentos de física de raios cósmicos. Discutimos os processos de formação e leitura do sinal quando da passagem de uma partícula ionizante pela região ativa do detector e apresentamos os resultados experimentais relevantes: espectros de carga, eficiência, contagem e resolução temporal. Obtivemos uma eficiência de 85 % e uma resolução temporal de 4ns, suficiente para a realização de medidas de ´tempo de vôo´. Os RPCs estudados foram construídos no Laboratório de Léptons do Instituto de Física Gleb Wataghin, Unicamp, a partir de componentes nacionais disponíveis no mercado. A modularidade dos RPCs e seu baixo custo sugerem que esses detectores são apropriados para experimentos de raios cósmicos, onde grandes áreas de detecção estão envolvidas; We present a study about Resistive Plate Counters and the viability of their use in cosmic ray experiments. The processes of discharge formation by an ionizing particle and signal pick up are discussed, and the relevant experimental results ? charge spectra, efficiency, counting rates and time resolution are shown. An efficiency of 85 % and a time resolution of 4 ns...

Caracterização das medidas de fundo e blindagem em detectores subterrâneos de xenônio líquido; Characterization on background and shielding of underground detector based on liquid xenon

Bruno Silva Rodriguez Miguez
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 30/06/2014 PT
Relevância na Pesquisa
37.01464%
Uma das grandes fronteiras da física atual é a identificação da Matéria Escura, que seria responsável por cerca de 25% da densidade do universo. Diversos candidatos a Matéria Escura foram propostos, entre eles os WIMPs (Weakly Interacting Massive Particle). A Colaboração Xenon tem como objetivo a detecção direta de matéria escura através de colisões elásticas com núcleos de xenônio, monitorados em uma câmara de projeção temporal. Os primeiros detectores da colaboração Xenon (Xenon10 e Xenon100) obtiveram grande sucesso impondo os limites mais restritivos para seção de choque WIMP-nucleon quando foram publicados seus resultados. Atualmente o terceiro detector da colaboração, o Xenon1T, está em construção e é esperado que ele verifique seções de choque até duas ordens de grandeza abaixo dos limites atuais. O Xenon1T possuirá um sistema de veto ativo, o Water Tank. A câmara de projeção temporal do Xenon1T será localizada dentro de um detector que busca, através da detecção de outros produtos, identificar nêutrons rápidos produzidos através da interação de múons com as rochas ou estrutura ao redor do detector. As paredes internas do Water Tank são cobertas com uma folha refletora DF2000MA para aumentar a captação de luz. Nesta tese foi estudada a taxa de eventos gerada pela resposta da folha DF2000MA à radioatividade do aço que compõe a estrutura do Water Tank e seu impacto no funcionamento do sistema de veto. A taxa destes eventos que gerariam um sinal no Water Tank seria da ordem de 10-4 Hz...

Sistema computacional baseado na lei de Biot-Savart (BSMAG) para cálculo de campos magnéticos em detectores de metais

Lima, Marcos de
Fonte: Florianópolis, SC Publicador: Florianópolis, SC
Tipo: Dissertação de Mestrado Formato: xiii, 53 f.| il., tabs., grafs.
POR
Relevância na Pesquisa
37.01464%
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica.; Neste trabalho é proposto um sistema computacional para o cálculo de campos magnéticos em detectores de metais. Para analisar o campo magnético em um tipo específico de detector de metais, PDM (Portal Detector de Metais), foi necessário fazer um estudo bibliográfico deste equipamento e desenvolver uma ferramenta numérica para o cálculo tridimensional do campo que permitisse calcular o campo no interior da região de detecção de metais. Com a utilização da ferramenta numérica denominada BSmag (sistema computacional baseado na lei de Biot-Savart para cálculo de campos) foi possível calcular o vetor campo magnético nos pontos de interesse assim como mostrar a sua distribuição no interior do PDM. Na concepção do sistema utilizou-se à lei de Biot-Savart que pode ser considerada como uma discretização da lei de Ampère e que pode ser utilizada em uma grande quantidade de problemas práticos. Após medições realizadas em um equipamento PDM foi possível comparar estes resultados com os valores obtidos utilizando o BSmag. Através do desenvolvimento deste sistema pretendeu-se...

Estudo de Monte Carlo da electroluminescência em detectores gasosos; Monte Carlo study of electroluminescence in gaseous detectors

Oliveira, Carlos Alberto Bastos de
Fonte: Universidade de Aveiro Publicador: Universidade de Aveiro
Tipo: Tese de Doutorado
ENG
Relevância na Pesquisa
37.169614%
Uma descrição detalhada do processo de electroluminescência é um prérequisito na optimização de detectores gasosos para sistemas de imagiologia, astrofísica, física de altas energias e experiências de eventos raros. Neste trabalho, é apresentada e caracterizada uma nova e versátil plataforma de simulação da emissão de luz durante a deriva de electrões em gases nobres, desenvolvida usando os programas Magboltz e Garfield. Propriedades intrínsecas da electroluminescência em gases nobres são calculadas e apresentadas em função do campo eléctrico aplicado, nomeadamente eficiências, rendimento e flutuações estatísticas associadas. São obtidos resultados em grande concordância com dados experimentais e simulações Monte Carlo anteriores. A plataforma é usada para determinar as condições óptimas de funcionamento de detectores como o NEXT (Neutrino Experiment with a Xenon TPC) e outros baseados nas micro-estruturas GEM (Gas Electron Multiplier) e MHSP (Micro- Hole & Strip Plate).; A good understanding of electroluminescence is a prerequisite when optimizing gaseous detectors for imaging systems, astrophysics, high energy physics and rare event experiments. In this work, a new versatile simulation toolkit for calculating the emission of light through electron impact on noble gases...

Análise de códigos detectores de erros utilizados na camada de transporte

da Silva Barboza, Ricardo; Dueire Lins, Rafael (Orientador)
Fonte: Universidade Federal de Pernambuco Publicador: Universidade Federal de Pernambuco
Tipo: Outros
PT_BR
Relevância na Pesquisa
37.01464%
Esta dissertação analisa as taxas de falhas na detecção de erros em alguns dos mais utilizados códigos detectores de erros na camada de transporte. Um simulador que gera erros em dados uniformemente e não uniformemente distribuídos foi desenvolvido. Nossos resultados mostraram altas taxas de falhas nos chamados checksums quando utilizamos parâmetros que geram padrões de erros que alteram poucos bits nas palavras código. Contra o que tem sido relado em artigos recentes, o Internet Checksum exibiu melhor desempenho quando dados não uniformemente distribuídos foram utilizados

Espectrometria de nêutrons com o sistema de esferas de Bonner utilizando detectores passivos termoluminescentes

Angelo de Lucena Santos, Joelan; Correia Vilela, Eudice (Orientador)
Fonte: Universidade Federal de Pernambuco Publicador: Universidade Federal de Pernambuco
Tipo: Outros
PT_BR
Relevância na Pesquisa
37.452607%
Nêutrons são partículas sem carga que podem ser removidos do núcleo atômico por algum processo de rearranjo nuclear, e assim, apresentar um espectro em energia compreendido desde baixa energia (En < 2x10-7 eV) até alta energia (En > 100 MeV). Sabe-se no entanto que, a energia dos nêutrons pode variar significativamente dentro de um mesmo ambiente, o que torna a espectrometria neutrônica imprescindível para a sua correta medida e posterior avaliação de doses às quais os trabalhadores expostos a este tipo de radiação estão sujeitos. Dos vários métodos utilizados para caracterizar o espectro neutrônico, o espectrômetro de multiesferas de Bonner é um dos sistemas espectrômetricos mais utilizados. Conhecido como Espectrômetro de Bonner (EB), esse sistema é composto por um conjunto de esferas moderadoras, onde no centro de cada esfera é possível acomodar um detector de nêutrons térmicos. Neste trabalho foram utilizados detectores termoluminescentes (TLDs) como detector de nêutrons. A escolha deste material deve-se ao fato do cintilador de 6LiI(Eu), por exemplo, não ser tão eficiente quando utilizado em campos mistos intensos, bem como pela necessidade de se utilizar equipamentos eletrônicos associados ao mesmo...

Avaliação do uso de detectores finos para a produção de imagem com feixes de prótons

Silva, Rita de Cássia de Lima
Fonte: Curitiba Publicador: Curitiba
Tipo: Dissertação de Mestrado
POR
Relevância na Pesquisa
37.01464%
Since the earliest works proposing the use of protons for imaging, the main advantage of protons over X-rays was expected to be a result of the specific property of the proton flux dropping off very steeply at the end of the particle range. This idea was declared but was not checked. In the present work, this assumption was investigated using the Monte Carlo simulation, with the help of SRIM-2008 software, for the case of a detector that registers only a small part of the proton exit energy (thin detector). First, a thickness of such detector was determined for the investigated water object of 20 cm. Then, it was studied the minimum dose absorbed by an object that is necessary to distinguish two water objects with the thicknesses of 20 cm and 20.1 cm as a function of the initial energy. The results were compared with the case of thick detector that registers the total exit energy. The carried out investigation shows that the principal idea of proton imaging to work near the end of the proton range is not correct in the case of thin detector as well as for thick one. In general, detector systems based on the measurement of the total exit energy are preferable to systems based on thin detectors.; CAPES; Desde os primeiros trabalhos propondo o uso dos prótons para a construção da imagem...

Diseño de detectores robustos en aplicaciones radar

Mata Moya, David Anastasio de la
Fonte: Universidade de Alcalá Publicador: Universidade de Alcalá
Tipo: info:eu-repo/semantics/doctoralThesis; info:eu-repo/semantics/acceptedVersion Formato: application/pdf
SPA
Relevância na Pesquisa
37.488674%
El problema de la detección automática de blancos radar puede ser formulado como un test de hipótesis binaria, en el que el sistema tiene que decir a favor de la hipótesis alternativa H1 (blanco presente) o de la hipótesis nula H0 (blanco ausente). El criterio de Neyman-Pearson, NP, es el más extendido en aplicaciones radar. Este detector trata de maximizar la probabilidad de detección, PD, manteniendo la probabilidad de falsa alarma, PFA, igual o inferior a un valor determinado. Cuando las funciones de verosimilitud son conocidas, una posible implementación del detector NP consiste en comparar el cociente de verosimilitud con un umbral fijado por los requisitos de PF A (LRT). Se trata de un detector paramétrico que puede presentar grandes pérdidas de detección cuando las características estadísticas del blanco y/o interferencia asumidas en el diseño difieren de las reales. En situaciones prácticas, las parámetros de la interferencia pueden estimarse a partir de medidas obtenidas en el entorno del radar, pero las propiedades del blanco pueden ser difíciles de estimar. Por lo que, para el diseño de detectores, se asume diferentes modelos de blanco cuyos parámetros, como su coeficiente de correlación o su frecuencia Doppler...

Puesta a punto de un sistema de lectura de trazas nucleares en detectores de radón CR-39; Setup of a system for reading nuclear tracks in CR-39 radon detectors

Herrera Díez, Adriana
Fonte: Universidade de Cantabria Publicador: Universidade de Cantabria
Tipo: Trabalho de Conclusão de Curso
SPA
Relevância na Pesquisa
37.01464%
RESUMEN: El estudio de la radiación que proviene del radón y de sus descendientes se ha visto incrementado en los últimos años, debido a la importancia que tiene su conocimiento para la salud pública, ya que la inhalación de este gas es la segunda causa de cáncer de pulmón en el mundo. Este trabajo se centra en el estudio de un nuevo sistema de lectura de trazas nucleares, en el que se ha empleado un software que se utiliza para el conteo de células. Se han llevado a cabo diversos análisis para la puesta a punto del software y se han analizado los criterios que hay que tener en cuenta a la hora de realizar dichas lecturas. Para corroborar la eficacia de este nuevo método, se han llevado a cabo una serie de ejercicios, que se emplean actualmente para analizar la eficacia de los diferentes métodos empleados en los laboratorios, que calculan y analizan la radiación por emisiones de radón. Se han utilizado datos que provienen de tres laboratorios de referencia internacionales que son HPA (Reino Unido), NIRS (Japón) y BFS (Alemania). Finalmente, se ha medido el fondo de los detectores con un mecanismo innovador. Consiste en el conteo de las trazas que se encuentran tras una lámina de aluminio colocada sobre la mitad del detector.; ABSTRAC: The study of the radiation comes from the radon and its descendants has been increased over the last years due to the importance that its awareness has for public health since the inhalation of the gas is the second cause of lung cancer in the world. This project focuses on the study of a new reading system of nuclear tracks in which it has often been used software for counting cells. Several analyzes have been carried out in order to set up the software and different criteria have been taken into account when performing such readings. Some exercises have been employed to check the effectiveness of this new method which is currently used in order to analyse the effectiveness of different methods carried out in laboratories and which calculate and analyse the radiation by the radon emission. It has been used the data from three laboratories of international reference which are HPA (United Kingdom). NIRS (Japan) and BFS (Germany). Finally...

Análisis y diseño electromagnético de detectores Kid para aplicaciones espaciales a frecuencias de THZ

Blázquez Valles, Beatriz
Fonte: Universidade Carlos III de Madrid Publicador: Universidade Carlos III de Madrid
Tipo: info:eu-repo/semantics/bachelorThesis; info:eu-repo/semantics/masterThesis Formato: application/pdf
SPA
Relevância na Pesquisa
37.169614%
La banda submilimétrica, o del infrarrojo lejano, es la porción del espectro electromagnético de la que menos información se tiene. La investigación de esta banda se ha convertido en un tema importante y de gran alcance tanto para aplicaciones espaciales como terrestres. Hasta la fecha, los dispositivos criogénicos eran los detectores más sensibles que existían para muchas de estas aplicaciones. Sin embargo, la siguiente generación de instrumentos astronómicos requiere de grandes campos de visión directa con cámaras de millones de píxeles para permitir la medición simultánea de un gran número de bandas espectroscópicas en una amplia zona del cielo. La dificultad de los dispositivos criogénicos para ser integrados en estos grandes arrays, ha hecho que sea necesario buscar otras opciones. Los recién desarrollados MKIDs (Microwave Kinetic Inductance Detectors) tienen el potencial necesario para la creación de estas matrices de gran tamaño. El principio de funcionamiento de estos dispositivos se basa en el incremento en la población de cuasipartículas y el correspondiente incremento de la inductancia cinética, producida dentro del volumen de un superconductor al incidir en él fotones o fonones con una energía superior a la energía vinculante que une los pares de Cooper del superconductor. Esta pequeña variación en la inductancia puede medirse por medio de un circuito resonante de microondas con un alto factor de calidad. La absorción de un fotón modifica la inductancia del circuito y hace variar ligeramente la frecuencia de resonancia. El objetivo final de este proyecto es realizar un estudio práctico sobre los detectores de tipo KID...

Avaliação dos detectores de defeitos e sua influência nas operações de consenso; On the evaluation of failure detectors and their influence on consensus operations

Estefanel, Luiz Angelo Barchet
Fonte: Universidade Federal do Rio Grande do Sul Publicador: Universidade Federal do Rio Grande do Sul
Tipo: Dissertação Formato: application/pdf
POR
Relevância na Pesquisa
27.582146%
Este trabalho relata observações e analises sobre como os detectores de defeitos influenciam as operação de consenso. O conceito dos detectores de defeitos é essencial para as operações de consenso em sistemas distribuídos assíncronos, uma vez que esses representam uma das (micas formas de sobrepujar as limitações impostas pela chamada Impossibilidade FLP (impossibilidade de diferenciar um processo falho de um processo mais lento). Enquanto os detectores de defeitos tem seu funcionamento bem definido através de duas propriedades, completeness e accuracy, Não há nenhuma restrição quanto a forma de implementá-los. Na literatura são encontrados vários modelos de detectores de defeitos, construídos com as mais variadas estratégias, mecanismos de comunicação e de detecção. No entanto, estes modelos não costumam ser acompanhados de uma comparação com os detectores já existentes; os autores limitam-se a apresentar as inovações dos mecanismos sugeridos. De toda literatura pesquisada, apenas um trabalho procurou comparar diferentes modelos de detectores de defeitos, e através de simulações, avaliou o impacto destes detectores sobre o tempo de terminação das operações de consenso. Entretanto, aquele trabalho era bem limitado...

Estudio de rayos cósmicos de muy alta energía con AMIGA, una extensión del Observatorio Pierre Auger: detectores de superficie y contadores de muones para estudiar la composición, dirección de arribo y espectro de los rayos cósmicos; Study of ultra high energy cosmic rays with AMIGA, an extension of the Pierre Auger Observatory: surface detectors and muon counter tu study the composition, the arrival direction and spectrum of the cosmic rays

Sidelnik, Iván Pedro
Fonte: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires Publicador: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires
Tipo: info:eu-repo/semantics/doctoralThesis; tesis doctoral; info:eu-repo/semantics/publishedVersion Formato: application/pdf
Publicado em //2012 SPA
Relevância na Pesquisa
37.543071%
Los rayos cósmicos son partículas que llegan a nuestro planeta desde el espacio exterior, con energías comprendidas entre 109 eV y 1020 eV, siendo los más energéticos un gran enigma, ya que no conocemos cuales son sus fuentes, su composición química ni cómo son acelerados. El Observatorio Pierre Auger (PAO) fue dise~nado y construido para estudiar los rayos cósmicos a energías mayores de 1018 eV. El mismo se encuentra en la zona de Pampa Amarilla, próximo a la ciudad de Malargüe, en la provincia de Mendoza. Su tamaño gigante de aproximadamente 3000 km2 y el concepto híbrido de detección, proporcionado por detectores de superficie y de fluorescencia atmosférica, confieren al PAO capacidad suficiente para evaluar el espectro de energía, direcciones de arribo y composición química de los rayos cósmicos. Estos observables son los más importantes y el PAO los mide con altísima resolución y una estadística sin precedentes, utilizando las lluvias atmosféricas extensas que estos generan cuando ingresan a la atmósfera. Para bajar la energía umbral de detección del PAO a valores de 1017 eV, distintas extensiones fueron elaboradas en los últimos años. Uno de estos proyectos es Auger Muons and Infill for the Ground Array (AMIGA)...

Estudio de rayos cósmicos de muy alta energía con AMIGA, una extensión del Observatorio Pierre Auger: detectores de superficie y contadores de muones para estudiar la composición, dirección de arribo y espectro de los rayos cósmicos; Study of ultra high energy cosmic rays with AMIGA, an extension of the Pierre Auger Observatory: surface detectors and muon counter tu study the composition, the arrival direction and spectrum of the cosmic rays

Sidelnik, Iván Pedro
Fonte: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires Publicador: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires
Tipo: Tesis Doctoral Formato: text; pdf
Publicado em //2012 ESPAñOL
Relevância na Pesquisa
37.543071%
Los rayos cósmicos son partículas que llegan a nuestro planeta desde el espacio exterior, con energías comprendidas entre 109 eV y 1020 eV, siendo los más energéticos un gran enigma, ya que no conocemos cuales son sus fuentes, su composición química ni cómo son acelerados. El Observatorio Pierre Auger (PAO) fue dise~nado y construido para estudiar los rayos cósmicos a energías mayores de 1018 eV. El mismo se encuentra en la zona de Pampa Amarilla, próximo a la ciudad de Malargüe, en la provincia de Mendoza. Su tamaño gigante de aproximadamente 3000 km2 y el concepto híbrido de detección, proporcionado por detectores de superficie y de fluorescencia atmosférica, confieren al PAO capacidad suficiente para evaluar el espectro de energía, direcciones de arribo y composición química de los rayos cósmicos. Estos observables son los más importantes y el PAO los mide con altísima resolución y una estadística sin precedentes, utilizando las lluvias atmosféricas extensas que estos generan cuando ingresan a la atmósfera. Para bajar la energía umbral de detección del PAO a valores de 1017 eV, distintas extensiones fueron elaboradas en los últimos años. Uno de estos proyectos es Auger Muons and Infill for the Ground Array (AMIGA)...

Estudo do funcionamento de GEM's em detectores de Xénon líquido

Balau, Estela Filipa dos Santos
Fonte: Universidade de Coimbra Publicador: Universidade de Coimbra
Tipo: Dissertação de Mestrado
POR
Relevância na Pesquisa
37.350415%
Este trabalho baseia-se no estudo experimental do comportamento de microestruturas do tipo GEM (Gas Electron multiplier), em detectores de xénon como meio de detector. A relevância deste estudo prende-se com a mais valia que este tipo de detectores poderá trazer em experiências relacionadas com a procura de materia negra no Universo, bem como em aplicações no campo da medicina. São apresentados tópicos de continuação deste trabalho, no que respeita á substituição dos GEM's por microestruturas MHSP (Micro-Hole and Strip Plate), no detector apresentado com vista a alcançar um melhor desempenho.

Diseño, fabricación y optimización de detectores con multiplicación (LGAD) para experimentos de física de altas energías

Fernández Martínez, Pablo
Fonte: [Barcelona] : Universitat Autònoma de Barcelona, Publicador: [Barcelona] : Universitat Autònoma de Barcelona,
Tipo: Tesis i dissertacions electròniques; info:eu-repo/semantics/doctoralThesis; info:eu-repo/semantics/publishedVersion Formato: application/pdf
Publicado em //2014 SPA
Relevância na Pesquisa
37.452607%
Cuando los dispositivos semiconductores, especialmente los basados en control por puerta MOS, se someten a una dosis elevada de radiación, sus características eléctricas se deterioran rápidamente. Además, la reducción de las dimensiones y del grosor de las capas utilizadas en su fabricación, los hace más sensibles frente a la radiación. Así, con objeto de poder diseñar nuevos componentes resistentes a la radiación, se ha desarrollado una metodología de simulación numérica que emula la generación de pares electrón-hueco en el volumen del semiconductor y su evolución temporal, dado que los resultados obtenidos mediante las herramientas disponibles en los simuladores comerciales no se ajustan a la realidad. El rigor del procedimiento de simulación se ha corroborado con medidas experimentales de transistores MOS de potencia para convertidores DC/DC de IHP Microelectronics (DE). La investigación central de la Tesis tiene como finalidad el diseño y fabricación de detectores de radiación basados en diodos de potencia tipo PiN. Los experimentos modernos de Física de Altas Energías demandan un uso creciente de detectores de radiación de altas prestaciones en cuanto a compacidad, velocidad de respuesta y resistencia al daño por radiación. La tecnología de Silicio...

Detectores y aceleradores que curan

Benedetti,Mario
Fonte: Acta bioquímica clínica latinoamericana Publicador: Acta bioquímica clínica latinoamericana
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2013 ES
Relevância na Pesquisa
37.01464%
Los aceleradores y los detectores utilizados en las investigaciones en física de partículas sirven y han servido desde hace más de 100 años para la detección y cura de enfermedades. Gracias a los avances en la física experimental de partículas, se han desarrollado a lo largo de los años aceleradores más potentes y sistemas de detección más precisos y sofisticados. Estos, conjuntamente con los modernos sistemas de cómputo, han permitido aplicaciones hasta hace poco tiempo impensadas en la medicina. En este trabajo se esboza la historia de estos instrumentos, sus principios de funcionamiento y sus ventajas en las aplicaciones médicas, especialmente en el campo de la detección y tratamiento de tumores.