Página 1 dos resultados de 33424 itens digitais encontrados em 0.023 segundos

"Estudo comparativo entre a tomografia computadorizada e a tomografia volumétrica na confecção de modelos de prototipagem"; Comparison of cone beam computerized tomography and multislice computerized tomography for building rapid prototyping models

Saddy, Mario Sergio
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 07/12/2006 PT
Relevância na Pesquisa
36.5%
O objetivo neste estudo foi comparar modelos de prototipagem, originados a partir de dados obtidos em exames de tomografia volumétrica (TV) e tomografia computadorizada (TC), a fim de verificar a precisão de reprodutibilidade destas tecnologias. Uma mandíbula seca foi submetida aos exames de TV (NewTom 9000? QR, Itália) e TC (Select SP-Elscint, Israel). Os dados obtidos nos exames foram manipulados em dois sistemas de tratamento de imagem, o 3D- Analyze (Mayo Clinic, E.U.A.) e o InVesalius (CenPRA, Brasil) e confeccionados protótipos, em duas diferentes tecnologias (SLS - sinterização seletiva a laser e 3DP - impressão tridimensional). A mandíbula seca (padrão ouro) e os oito conjuntos de protótipos gerados, sendo I-TC-Analyze?3DP; II-TC-Invesalius?3DP; III-TC-Analyze?SLS; IVTC- Invesalius-SLS; V-TV-Analyze?3DP; VI-TV-Invesalius?3DP; VIII-TV-Analyze? SLS; VIII-TV-Invesalius-SLS, foram submetidos a processos de engenharia reversa com a finalidade de digitalizar as superfícies dos objetos para uma comparação de cada modelo de prototipagem produzido com o padrão ouro, com precisão de 0,001mm. Os desvios de até 1mm e até 2mm foram calculados, comparados e analisados estatisticamente os erros percentuais. Os modelos de prototipagem rápida originados por meio da obtenção de dados de exames de tomografia computadorizada são mais precisos que os modelos de prototipagem originados por meio de dados de exames de tomografia volumétrica.; The purpose of this study is to compare rapid prototyping models created from cone beam computerized tomography (CBCT) and multislice computerized tomography (CT) data...

Utilização da ultra-sonografia modo B e da tomografia computadorizada no estudo do encéfalo de cães adultos; B-mode ultrasonography and computed tomography in evaluation of mature dog's brain

Lorigados, Carla Aparecida Batista
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 26/06/2008 PT
Relevância na Pesquisa
36.52%
A ultra-sonografia foi o primeiro meio diagnóstico por imagem utilizado na investigação do encéfalo, mas foi substituído pela tomografia computadorizada na década de 70 e atualmente por outros métodos como a ressonância magnética. O exame ultra-sonográfico continua sendo empregado em pacientes pediátricos e em animais jovens, cujas fontanelas permanecem abertas, servindo como janela acústica. Contudo, sua utilização em animais adultos fica restrita, em parte pela barreira proporcionada pelos ossos do crânio. Este trabalho objetivou: avaliar a possibilidade da utilização da ultra-sonografia transcraniana em cães adultos; estabelecer um paralelo com as imagens tomográficas; correlacionar as imagens sonográficas e tomográficas com a anatomia e comparar as imagens ultrasonográficas do encéfalo obtidas com e sem a interposição dos ossos do crânio. Foram utilizados dez cadáveres de cães adultos. As imagens tomográficas foram adquiridas em cortes transversais e dorsais com espessura de 5 mm e igual incremento. As imagens ultra-sonográficas foram obtidas através dos ossos temporal e porção lateral do parietal, da região frontoparietal dorsal íntegra e após craniotomia e do forame magno, em cortes transversais...

Identificação de padrões de resposta à tomografia de impulso em tipuanas (Tipuana tipu (Benth.) O. Kuntze; Identification of response patterns in the impulse tomography in tipuana (Tipuana tipu (Benth.) O. Kuntze

Rollo, Francisco Martins de Almeida
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 12/02/2010 PT
Relevância na Pesquisa
36.52%
As árvores desempenham papel fundamental na qualidade ambiental das áreas urbanas. Como a floresta urbana é alvo constante de ações inadequadas de manejo, tais como podas inapropriadas, técnicas que visam avaliar a qualidade dos indivíduos e o risco de queda de árvores são fundamentais para a diminuição de possíveis danos causados aos equipamentos urbanos além de risco aos habitantes das cidades. Os métodos de avaliação visual de árvores desenvolvidos para a identificação de problemas biomecânicos e fitossanitários possibilitaram que avaliações de risco de queda fossem conduzidas. Nesses métodos, inspeções detalhadas a respeito da extensão das lesões presentes no colo e tronco, que podem comprometer sua estabilidade, são recomendadas para os indivíduos. Entre as técnicas utilizadas para o reconhecimento de lesões internas, a tomografia destaca-se por fornecer informações a respeito de toda seção avaliada com apenas uma medição e por gerar uma imagem que permite identificar o posicionamento e a extensão das áreas lesionadas. Por ser um método relativamente novo, são necessários estudos que visem identificar a resposta à tomografia em diferentes espécies, possibilitando desta forma a identificação precisa das áreas lesionadas. O trabalho realizado teve por objetivo testar a confiabilidade das informações geradas pela tomografia de impulso e identificar padrões de resposta em árvores de tipuana (Tipuana tipu (Benth.) O. Kuntze). Trinta e nove indivíduos que apresentaram sinais de injúria...

Correlação entre o eletrorretinograma de padrão reverso, a tomografia de coerência óptica e a perimetria automatizada na detecção da perda neural na atrofia em banda do nervo óptico; Relationship between pattern electroretinogram, optical coherence tomography and automated perimetry for detection of neural loss in eyes with band atrophy of the optic nerve

Cunha, Leonardo Provetti
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 09/08/2010 PT
Relevância na Pesquisa
36.52%
OBJETIVO: Avaliar a capacidade dos parâmetros do eletrorretinograma de padrão reverso de campo total e hemianópico em diferenciar olhos com atrofia em banda do nervo óptico e, a correlação entre as amplitudes do eletrorretinograma de padrão reverso, a espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica e a perda de campo visual nestes pacientes. MÉTODOS: Quarenta e um olhos de 41 pacientes com perda de campo visual temporal permanente por compressão do quiasma óptico e 41 controles normais foram submetidos ao eletrorretinograma de padrão reverso de estimulação de campo total e hemianópicos (temporal e nasal), a tomografia de coerência óptica, para avaliação das medidas da espessura da camada de fibras nervosas da retina e macular e, ao exame de campo visual, pela perimetria automatizada padrão. O desvio do normal da sensibilidade dos 18º centrais do campo visual foram expressos em decibéis e unidades 1/Lambert. As comparações foram feitas pelo teste t de Student. A correlação entre os parâmetros do campo visual central, do eletrorretinograma de padrão reverso e da tomografia de coerência óptica foi avaliada pela correlação de Pearson e análise de regressão linear. RESULTADOS: Os valores das amplitudes P50...

Aplicação da tomografia de impulso na avaliação da qualidade do lenho de árvores de maçaranduba, Manilkara huberi (Ducke) Chevalier; Impulse tomography application in quality wood evaluation of trees of maçaranduba, Manilkara huberi (Ducke) Chevalier

Uliana, Lis Rodrigues
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 10/11/2010 PT
Relevância na Pesquisa
36.56%
Este trabalho trata da avaliação dos padrões de resposta e da eficácia do método da tomografia de impulso na identificação de lesões e ocos no lenho de árvores de espécies madeireiras da região Amazônica, através do estudo de indivíduos da espécie Manilkara huberi Ducke (Chevalier) (família Sapotaceae). Lesões e ocos resultam do ataque de insetos e fungos e sua ocorrência pode ser favorecida por injúrias como fogo, quebra de galhos e de características do sítio. A colheita de árvores com grandes lesões ou ocos resulta em grande geração de resíduos no campo e na indústria, com impactos ambientais e econômicos negativos. Os métodos tradicionais de verificação de lesões e ocos para seleção de espécies tropicais são muito subjetivos e pouco eficientes, baseados principalmente na experiência dos mateiros e operadores de motosserra. O estudo foi realizado numa área de 3 ha no município de Paragominas, PA. Foram avaliadas 29 árvores de maçaranduba com DAP entre 50 e 130 cm, separadas em 4 grupos, em função do DAP e da ocorrência de oco. A análise da árvore em pé se deu através do tomógrafo de impulso, o qual gerou um gráfico de velocidade e uma imagem da qualidade do lenho. Foram coletadas amostras de solo próximas a cada indivíduo e realizadas análises químicas e físicas para análise da influência do solo na ocorrência de oco. As árvores foram cubadas e feitas estimativas de volume de madeira total (volume da árvore)...

Avaliação do canal incisivo da mandíbula por meio de radiografia panorâmica e tomografia computadorizada por feixe cônico; Evaluation of the mandibular incisive canal obtained by panoramic radiography and cone-beam computed tomography

Shimura, Elisabeth Mieko
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 25/07/2012 PT
Relevância na Pesquisa
36.52%
A região entre os forames mentuais era considerada uma área segura para realização de procedimentos cirúrgicos. Na literatura encontramos algumas complicações que podem surgir durante os procedimentos cirúrgicos, devido à variação anatômica do nervo alveolar inferior, que pode estender-se formando o canal do nervo incisivo, com uma extensão anterior ao forame mentual. A radiografia panorâmica é uma técnica radiográfica extra-oral amplamente utilizada. Entretanto, é uma imagem bi-dimensional de uma estrutura tridimensional. Com o surgimento da tomografia computadorizada por feixe cônico, temos acesso a uma avaliação tridimensional de imagens. O objetivo neste estudo foi avaliar a identificação do canal incisivo da mandíbula na radiografia panorâmica e na tomografia computadorizada por feixe cônico. Foram utilizados 150 exames compostos de tomografia computadorizada volumétrica e radiografia panorâmica que foram avaliados por 2 observadores em 2 momentos diferentes. Na comparação entre os métodos os resultados mostraram que a diferença foi estatisticamente significante (p<0,001) para os 2 observadores. A identificação do canal incisivo da mandíbula na tomografia computadorizada foi superior em relação à panorâmica. Em média os observadores identificaram o canal incisivo em 29...

Avaliação qualitativa de biomateriais utilizados para enxertia em alvéolos dentais, em mandíbulas de suínos, por meio da tomografia computadorizada Cone Beam; Qualitative evaluation of biomaterials used in pig mandibles dental cavities graftings, by means of Cone-Beam computed tomography

Azevedo, Ana Cláudia
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 17/06/2013 PT
Relevância na Pesquisa
36.5%
A invenção da Tomografia Computadorizada revolucionou o método de diagnóstico. Apesar de ser um exame de custo elevado, sua confiabilidade é de grande valia. Na década de noventa foram descritos os primeiros relatos da tomografia computadorizada Cone Beam para o uso na Odontologia. Esses aparelhos de tomografia computadorizada por feixe cônico, Cone Beam ou volumétrica são mais compactos, de menor custo e com menor tempo de exposição à radiação ao paciente, quando comparados aos aparelhos de tomografia computadorizada médica ou Fan Beam. Diante da grande utilização de implantes osseointegrados, algumas dificuldades foram despontando, visto que também paralelamente a este, os defeitos ósseos necessitavam de correção. Então os enxertos ósseos ou biomateriais de enxertia passaram a ser a alternativa que possibilitava a correção dessas perdas ósseas. Com o objetivo de estudar e avaliar qualitativamente os biomateriais de enxertia, inseridos em alvéolos dentais, em mandíbulas de suínos, por meio da tomografia computadorizada Cone Beam, utilizou-se de 20 mandíbulas dissecadas de porco, dos quais foram extraídos quatro dentes e nesses alvéolos foram introduzidos quatro biomateriais de enxertia de composições diferentes...

Avaliação tomográfica dinâmica pré e pós-reconstrução do ligamento patelofemoral medial de pacientes com instabilidade patelar recidivante; Dynamic computerized tomography for analyzing patients with patellar instability before and after medial patellofemoral ligament reconstruction

Gobbi, Riccardo Gomes
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 26/05/2015 PT
Relevância na Pesquisa
36.5%
A instabilidade patelar é uma patologia comum dentro da especialidade da cirurgia do joelho. O principal fator estabilizador dessa articulação é o ligamento patelofemoral medial, sendo esta a principal estrutura a ser reconstruída no tratamento cirúrgico da instabilidade patelar. Apesar de sua reconstrução apresentar excelentes resultados clínicos, não se sabe ao certo o real efeito in vivo desse procedimento no movimento da patela ao redor do fêmur. A avaliação da articulação patelofemoral tradicionalmente é feita através de exames de imagem estáticos. Com a evolução dos aparelhos de tomografia computadorizada, se tornou possível realizar esse exame durante movimento ativo, técnica ainda pouco utilizada para estudo de articulações como o joelho. O objetivo deste estudo foi padronizar o uso da tomografia de 320 fileiras de detectores para estudo dinâmico da articulação patelofemoral em pacientes com instabilidade patelar recidivante pré e pós-reconstrução do ligamento patelofemoral medial, analisando o efeito da cirurgia no trajeto da patela ao longo do arco de movimento. Foram selecionados 10 pacientes com instabilidade patelar e indicação de reconstrução do ligamento patelofemoral medial isolada...

Retinal thickness assessed by optical coherence tomography (OCT) in pseudophakic macular edema

Bonanomi,Maria Teresa Brizzi Chizzoti; Nicoletti,André Gustavo Bombana; Carricondo,Pedro Carlos; Buzalaf,Flávio; Kara-José Jr,Newton; Gomes,André Marcelo Vieira; Nakashima,Yoshitaka
Fonte: Conselho Brasileiro de Oftalmologia Publicador: Conselho Brasileiro de Oftalmologia
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/08/2006 EN
Relevância na Pesquisa
36.5%
PURPOSE: To evaluate the usefulness of the optical coherence tomography (OCT) retinal map in angiographic pseudophakic macular edema (ACME). METHODS: This is a prospective analysis of a group of 36 pseudophakic eyes at the fifth postoperative week, submitted to optical coherence tomography 2 macular map and fluorescein angiography on the same day and, a control group of twenty-two 20/20 vision eyes with a minimum 6-month postoperative period, submitted to optical coherence tomography 2 macular map only. Exclusion criteria were diabetes, any macular pathology and unreadable optical coherence tomography or angiogram. The angiograms were divided into three groups according to the edema intensity: Group I: level 0 (absence of angiographic pseudophakic macular edema); group II: levels 1 and 2 (incomplete and complete perifoveal angiographic pseudophakic macular edema respectively) and group III: levels 3 and 4 (up to one disc diameter and greater than one disc diameter angiographic pseudophakic macular edema area respectively). The nine zones of the optical coherence tomography macular map were compared between the control and the three subgroups of the study group and, between group I and groups II and III. RESULTS: Among the 36 eyes, 23 (64%) were classified as group I...

Persistent asthma in adults: comparison of high resolution computed tomography of the lungs after one year of follow-up

Cukier,Alberto; Stelmach,Rafael; Kavakama,Jorge Issamu; Terra Filho,Mário; Vargas,Francisco
Fonte: Faculdade de Medicina / Universidade de São Paulo - FM/USP Publicador: Faculdade de Medicina / Universidade de São Paulo - FM/USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2001 EN
Relevância na Pesquisa
36.5%
OBJECTIVE: The aims of this study were to evaluate the role of high resolution computed tomography of the torax in detecting abnormalities in chronic asthmatic patients and to determine the behavior of these lesions after at least one year. METHOD: Fourteen persistent asthmatic patients with a mean forced expiratory volume in 1-second that was 63% of predicted and a mean forced expiratory volume in 1-second /forced vital capacity of 60% had two high resolution computed tomographys separated by an interval of at least one year. RESULTS: All 14 patients had abnormalities on both scans. The most common abnormality was bronchial wall thickening, which was present in all patients on both computed tomographys. Bronchiectasis was suggested on the first computed tomography in 5 of the 14 (36%) patients, but on follow-up, the bronchial dilatation had disappeared in 2 and diminished in a third. Only one patient had any emphysematous changes; a minimal persistent area of paraseptal emphysema was present on both scans. In 3 patients, a "mosaic" appearance was observed on the first scan, and this persisted on the follow-up computed tomography. Two patients had persistent areas of mucoid impaction. In a third patient, mucus plugging was detected only on the second computed tomography. CONCLUSIONS: We conclude that there are many abnormalities on the high resolution computed tomography of patients with persistent asthma. Changes suggestive of bronchiectasis...

Clinical versus computed tomography evaluation in the diagnosis and management of deep neck infection

Crespo,Agricio Nubiato; Chone,Carlos Takahiro; Fonseca,Adriano Santana; Montenegro,Maria Carolina; Pereira,Rodrigo; Milani,João Altemani
Fonte: Associação Paulista de Medicina - APM Publicador: Associação Paulista de Medicina - APM
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2004 EN
Relevância na Pesquisa
36.52%
CONTEXT: Deep neck infections have high potential for severe complications and even death, if not properly managed. The difference between clinical and computed tomography findings may demonstrate that clinical evaluation alone underestimates disease extent, which may lead to conservative treatment with worse prognosis. OBJECTIVE: To compare clinical and computed tomography findings from neck spaces affected by deep neck infections and to determine the main clinical and radiological features associated with these. TYPE OF STUDY: Non-randomized retrospective study. SETTING: Department of Otolaryngology and Head and Neck, Universidade Estadual de Campinas. METHODS: Medical charts of 65 patients with deep neck infections were evaluated. Age, gender, clinical complaints, physical findings, computed tomography scan and x-ray imaging, microbiology, treatment and outcome were analyzed. All clinical signs and symptoms were evaluated and stratified in order of frequency. The frequency of neck space involvement in such infections was also assessed from the clinical and tomographic evaluation. All clinical and computed tomography findings were compared with surgical observation. RESULTS: The most frequent clinical findings were neck swelling...

Comparison of ultrasonography, computed tomography and magnetic resonance imaging with intraoperative measurements in the evaluation of abdominal aortic aneurysms

Azevedo,Francisco das Chagas de; Zerati,Antonio Eduardo; Blasbalg,Roberto; Wolosker,Nelson; Puech-Leão,Pedro
Fonte: Faculdade de Medicina / USP Publicador: Faculdade de Medicina / USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/02/2005 EN
Relevância na Pesquisa
36.54%
PURPOSE: To study the imaging exams more commonly used for abdominal aortic aneurysms evaluation - ultrasonography, conventional computerized tomography, helical computerized tomography and nuclear magnetic angioresonance - comparing the preoperative measurements reached by those radiological methods with the measurements made during the surgical procedures. METHODS: Patients who had indication of elective transperitoneal surgical treatment for their abdominal aortic aneurysms were included in the study. The initial diagnosis of the aortic dilatation was made by ultrasonography and, after the surgical treatment was indicated, the patient was submitted to another imaging method. Sixty patients were divided into 3 groups according to the complementary imaging method (conventional computerised tomography, helical computerized tomography, nuclear magnetic angioresonance). The ultrasonography of the first 20 patients were joined in a fourth group. There were considered in the study the measurements of the transversal diameter of the proximal neck, maximum transversal diameter of the aneurysm, straight-line length and transversal diameter of the common iliac arteries given by the imaging methods. The same measurements were made by using a caliper during the surgical procedure...

Time-Domain Fluorescence Diffuse Optical Tomography: Algorithms and Applications

Hou, Steven Shuyu
Fonte: Harvard University Publicador: Harvard University
Tipo: Thesis or Dissertation
EN_US
Relevância na Pesquisa
36.52%
Fluorescence diffuse optical tomography provides non-invasive, in vivo imaging of molecular targets in small animals. While standard fluorescence microscopy is limited to shallow depths and small fields of view, tomographic methods allows recovery of the distribution of fluorescent probes throughout the small animal body. In this thesis, we present novel reconstruction algorithms for the tomographic separation of optical parameters using time-domain (TD) measurements. These technique are validated using simulations and with experimental phantom and mouse imaging studies. We outline the contributions of each chapter of the thesis below. First, we explore the TD fluorescence tomography reconstruction problem for single and multiple fluorophores with discrete lifetimes. We focus on late arriving photons and compare a direct inversion approach with a two-step, asymptotic approach operating on the same TD data. We show that for lifetime multiplexing, the two methods produce fundamentally different kinds of solutions. The direct inversion is computationally inefficient and results in poor separation but has overall higher resolution while the asymptotic approach provides better separation, relative quantitation of lifetime components and localization but has overall lower resolution. We verify these results with simulation and experimental phantoms. Second...

Improving dynamic tomography, through maximum a posteriori estimation

Myers, Glenn R.; Geleta, Matthew; Kingston, Andrew M.; Recur, Benoit; Sheppard, Adrian P.
Fonte: Society of Photo-Optical Instrumentation Engineers (SPIE) Publicador: Society of Photo-Optical Instrumentation Engineers (SPIE)
Tipo: Conference paper
Relevância na Pesquisa
36.5%
Direct study of pore-scale fluid displacements, and other dynamic (i.e. time-dependent) processes is not feasible with conventional X-ray micro computed tomography (μCT). We have previously verified that a priori knowledge of the underlying physics can be used to conduct high-resolution, time-resolved imaging of continuous, complex processes, at existing X-ray μCT facilities. In this paper we present a maximum a posteriori (MAP) model of the dynamic tomography problem, which allows us to easily adapt and generalise our previous dynamic μCT approach to systems with more complex underlying physics.

The use of live-animal micro-computed tomography to determine the effect of a novel phospholipase A₂ inhibitor on alveolar bone loss in an in vivo mouse model of periodontitis; The use of live-animal micro-computed tomography to determine the effect of a novel phospholipase A(2) inhibitor on alveolar bone loss in an in vivo mouse model of periodontitis

Cantley, M.; Bartold, P.; Marino, V.; Reid, R.; Fairlie, D.; Wyszynski, R.; Zilm, P.; Haynes, D.
Fonte: Blackwell Munksgaard Publicador: Blackwell Munksgaard
Tipo: Artigo de Revista Científica
Publicado em //2009 EN
Relevância na Pesquisa
36.5%
BACKGROUND AND OBJECTIVE: Live-animal micro-computed tomography is a new and promising technique that can be used to quantify changes in bone volume for periodontal disease models. The major aim of this study was to develop the methodology of live-animal micro-computed tomography and to determine the effect of a novel secretory phospholipase A2 inhibitor on alveolar bone loss. MATERIAL AND METHODS: Periodontitis was induced in mice by oral infection with Porphyromonas gingivalis over a period of 13 wk, and live-animal micro-computed tomography scans were taken at different time-points to determine bone volume changes with disease progression. This enabled conclusions to be made as to when treatment was most likely to be effective. In addition, the model was used to investigate a novel drug, the secretory phospholipase A2 inhibitor, KHO64, and its potential ability to inhibit osteoclast bone resorption and treat periodontitis. RESULTS: The results from live-animal micro-computed tomography scans revealed greater, statistically significant, bone volume loss in diseased mice compared with normal mice (p < 0.05). This corresponded to a larger area from the cemento-enamel junction to the alveolar bone crest, as assessed by stereo imaging (p < 0.001). These techniques can therefore detect and quantify alveolar bone loss. Both methods revealed that KHO64 had no significant effect on the volume of bone resorption. CONCLUSION: Live-animal micro-computed tomography is a robust...

Simulation and Experimental Investigation on the AE Tomography to Improve AE Source Location in the Concrete Structure

Jiang, Yu; Xu, Feiyun; Xu, Bingsheng; Jia, Minping; Hu, Jianzhong; Gallego Molina, Antolino
Fonte: Hindawi Publishing Corporation Publicador: Hindawi Publishing Corporation
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
36.56%
Acoustic emission (AE) tomography, which is based on the time-travel tomography with AE events as its signal sources, is a new visualization tool for inspecting and locating the internal damages in the structures. In this paper, AE tomography is applied to examine a man-made damage in a typical heterogeneous concrete structure to validate its effectiveness. Firstly, the finite element (ABAQUS/Explicit) simulation model of the concrete structure with one damaged circle in its center is built, and the simulated AE signals are obtained to establish the AE tomography. The results show that the damaged circle in the created model can be visualized clearly with the AE tomography in its original location. Secondly, the concrete specimen based on the FE model is fabricated, and the pencil lead break (PLB) signal is taken as the exciting source for AE tomography. It is shown that the experimental results have good consistency with the FE simulation results, which also verifies the feasibility of the finite element model for AE tomography. Finally, the damage source location based on AE tomography is compared with the traditional time of arrival (TOA) location method, and the better location accuracy is obtained with the AE tomography. The research results indicate that AE tomography has great potential in the application of structure damage detection.

Validação do uso de cone-beam computed tomography de kilovoltagem de um LINAC para a realização de estudos dosimétricos

Barbosa, Joana Figueiredo Gomes Medeiros
Fonte: Escola Superior de Tecnologia da Saúde de Lisboa Publicador: Escola Superior de Tecnologia da Saúde de Lisboa
Tipo: Dissertação de Mestrado
Publicado em //2013 POR
Relevância na Pesquisa
36.55%
Mestrado em Radioterapia; Objetivo: Determinar se o uso de imagens de Cone-Beam Computed Tomography de kilovoltagem de um acelerador linear para realizar estudos dosimétricos de Radioterapia tem igual precisão dosimétrica ao uso de imagens de Tomografia Computorizada de planeamento. Materiais e Métodos: Adquiriram-se imagens de Tomografia Computorizada dos fantomas CIRS® Electron Density e CIRS® IMRT Head & Torso com os protocolos clínicos, usados para planeamento dosimétrico. De seguida adquiriu-se para os mesmos fantomas e para o fantoma Catphan® 600, imagens de Cone-Beam Computed Tomography de kilovoltagem no OB®I do acelerador linear Clinac® 2100 DHX. Com as imagens adquiridas do Catphan® 600 criaram-se as curvas de calibração de Unidades de Hounsfield. Comparou-se o número de Unidades de Hounsfield entre os dois sistemas. Realizou-se um plano dosimétrico nos diferentes protocolos para o fantoma CIRS® IMRT Head & Torso com fotões de 6MV e 16MV nas imagens de Tomografia Computorizada. Transpôs-se o mesmo plano, para as imagens de Cone-Beam Computed Tomography de kilovoltagem de modo a comparar as diferenças nas unidades monitor e dose. Discussão de Resultados: Ao comparar as Unidades de Hounsfield obtidas...

Using computed tomography colonography in patients at high risk of colorectal cancer - a prospective study in a university hospital in South America

Atzingen,Augusto Castelli von; Tiferes,Dario Ariel; Deak,Elizabeth; Matos,Délcio; D′Ippolito,Giuseppe
Fonte: Faculdade de Medicina / USP Publicador: Faculdade de Medicina / USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/11/2014 EN
Relevância na Pesquisa
36.56%
OBJECTIVES: The purpose of our study was to report the results of the implementation of computed tomography colonography in a university hospital setting serving a Brazilian population at high risk of colorectal cancer. METHODS: After creating a computed tomography colonography service in our institution, 85 patients at high risk of colorectal cancer underwent computed tomography colonography followed by a same-day optical colonoscopy from September 2010 to May 2012. The overall accuracy of computed tomography colonography in the detection of lesions ≥6 mm was compared to that of optical colonoscopy (direct comparison). All colonic segments were evaluated using quality imaging (amount of liquid and solid residual feces and luminal distension). To assess patient acceptance and preference, a questionnaire was completed before and after the computed tomography colonography and optical colonoscopy. Fisher's exact test was used to measure the correlations between colonic distension, discomfort during the exam, exam preference and interpretation confidence. RESULTS: Thirteen carcinomas and twenty-two lesions ≥6 mm were characterized. The sensitivity, specificity and accuracy of computed tomography colonography were 100%, 98.2% and 98.6%...

Nuevos algoritmos cuánticos para tomografía de procesos y estados; New quantum algorithms for process and state tomography

Bendersky, Ariel Martín
Fonte: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires Publicador: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires
Tipo: info:eu-repo/semantics/doctoralThesis; tesis doctoral; info:eu-repo/semantics/publishedVersion Formato: application/pdf
Publicado em //2011 SPA
Relevância na Pesquisa
36.52%
Caracterizar los estados y procesos es una tarea con la que los físicos se cruzan cotidianamente. En esta tesis estudiamos diferentes algoritmos cuánticos para la tomografía de procesos y estados. En una primera parte presentamos dos algoritmos cuánticos para tomografía de procesos selectiva y eficiente y una comparación entre ellos y otros métodos selectivos. En una segunda parte estudiamos la tomografía de estados. Allí vemos en primer lugar un algoritmo de tomografía de estados selectiva y eficiente. Luego presentamos una teoría general de la medición cuando se dispone de dos copias simultáneas del estado cuántico. Ambas partes se encuentran íntimamente relacionadas por la dualidad entre estados y canales, lo que permite mantener en la segunda parte una visión retrospectiva analizando los protocolos de tomografía de estados en virtud de su capacidad de realizar tomografía de procesos.; Characterizing states and processes is a task that a physicist faces on a daily basis. In this thesis we study several quantum algorithms for process and state tomography. In a first part que introduce two quantum algorithms for selective and efficient quantum process tomography, along with a comparision between those and other algorithms. In a second part...

Comparação entre ultrassonografia, tomografia computadorizada e ressonância nuclear magnética com medidas intra-operatórias na avaliação dos aneurismas de aorta abdominal; Comparison of ultrasonography, computed tomography and magnetic resonance imaging with intraoperative measurements in the evaluation of abdominal aortic aneurysms

Azevedo, Francisco das Chagas de; Zerati, Antonio Eduardo; Blasbalg, Roberto; Wolosker, Nelson; Puech-Leão, Pedro
Fonte: Universidade de São Paulo. Faculdade de Medicina Publicador: Universidade de São Paulo. Faculdade de Medicina
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; Formato: application/pdf
Publicado em 01/02/2005 ENG
Relevância na Pesquisa
36.54%
OBJETIVO: Estudar os métodos mais freqüentemente empregados na avaliação dos aneurismas de aorta abdominal - ultrassonografia, tomografia computadorizada convencional, tomografia computadorizada helicoidal e angio-ressonância nuclear magnética - comparando as medidas fornecidas por estes exames radiológicos no pré-operatório com medidas realizadas durante a operação. MÉTODO: Foram incluídos no estudo pacientes portadores de aneurisma da aorta abdominal com indicação de tratamento cirúrgico eletivo por via transperitoneal. O diagnóstico inicial da dilatação aórtica foi feito com ultra-sonografia e, uma vez indicado o tratamento cirúrgico, era então solicitado um outro exame radiológico complementar, já que não é nossa rotina operar esses pacientes com base apenas na ultra-sonografia. Sessenta pacientes foram divididos em 3 grupos de acordo com o exame complementar realizado (tomografia computadorizada convencional, tomografia computadorizada helicoidal ou angio-ressonância nuclear magnética). As ultra-sonografias dos 20 primeiros pacientes foram incluídas em um 4° grupo. Analisamos neste estudo as medidas do colo proximal da aorta, o diâmetro transverso máximo e o comprimento do aneurisma, além do diâmetro transverso das artérias ilíacas comuns conseguidos a partir dos exames radiológicos. As mesmas medidas eram realizadas por ocasião da operação com o auxílio de um paquímetro e ...