Página 1 dos resultados de 1320 itens digitais encontrados em 0.004 segundos

Effect of erbium:yttrium-aluminum-garnet laser energies on superficial and deep dentin microhardness

CHINELATTI, Michelle Alexandra; RAUCCI-NETO, Walter; CORONA, Silmara Aparecida Milori; PALMA-DIBB, Regina Guenka
Fonte: SPRINGER LONDON LTD Publicador: SPRINGER LONDON LTD
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
37.47%
This study evaluated the microhardness of superficial and deep dentin irradiated with different erbium:yttrium-aluminum-garnet (Er:YAG) laser energies. Seventy-two molars were bisected and randomly assigned to two groups (superficial dentin or deep dentin) and into six subgroups (160 mJ, 200 mJ, 260 mJ, 300 mJ, 360 mJ, and control). After irradiation, the cavities were longitudinally bisected. Microhardness was measured at six points (20 A mu m, 40 A mu m, 60 A mu m, 80 A mu m, 100 A mu m, and 200 A mu m) under the cavity floor. Data were submitted to analysis of variance (ANOVA) and Fisher`s tests (alpha = 0.05). Superficial dentin presented higher microhardness than deep dentin; energy of 160 mJ resulted in the highest microhardness and 360 mJ the lowest one. Values at all points were different, exhibiting increasing microhardness throughout; superficial dentin microhardness was the highest at 20 A mu m with 160 mJ energy; for deep dentin, microhardness after irradiation at 160 mJ and 200 mJ was similar to that of the control. The lowest energy increased superficial dentin microhardness at the closest extent under the cavity; deep dentin microhardness was not altered by energies of 160 mJ and 200 mJ.; Foundation of the State of Sao Paulo (FAPESP)...

Effect of Chelating Solutions on the Microhardness of Root Canal Lumen Dentin

CRUZ-FILHO, Antonio M.; SOUSA-NETO, Manoel D.; SAVIOLI, Ricardo Novak; SILVA, Ricardo Gariba; VANSAN, Luiz Pascoal; PECORA, Jesus Djalma
Fonte: ELSEVIER SCIENCE INC Publicador: ELSEVIER SCIENCE INC
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
37.41%
Introduction: The greatest reduction in microhardness of the most superficial layer of dentin of the root canal lumen is desired. The use of chelating agents during biomechanical preparation of root canals removes smear layer, increasing the access of the irrigant into the dentin tubules to allow adequate disinfection, and also reduces dentin microhardness, facilitating the action of endodontic instruments. This study evaluated the effect of different chelating solutions on the microhardness of the most superficial dentin layer from the root canal lumen. Methods: Thirty-five recently extracted single-rooted maxillary central incisors were instrumented, and the roots were longitudinally sectioned in a mesiodistal direction to expose the entire canal extension. The specimens were distributed in seven groups according to the final irrigation: 15% EDTA, 10% citric acid, 5% malic acid, 5% acetic acid, apple vinegar, 10% sodium citrate, and control (no irrigation). A standardized volume of 50 mu L of each chelating solution was used for 5 minutes. Dentin microhardness was measured with a Knoop indenter under a 10-g load and a 15-second dwell time. Data were analyzed statistically by one-way analysis of variance and Tukey-Kramer multiple-comparison test at 5% significance level. Results: EDTA and citric acid had the greatest overall effect...

"Estudo do efeito da distância da ponta de aparelhos fotoativadores na microdureza e no grau de conversão da resina composta usando luz halógena, laser de argônio e LED"; Study of the effect of light curing tip distance on microhardness and on degree of conversion of a composite resin using halogen light, argon laser and LED.

Rode, Kátia Martins
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 16/02/2007 PT
Relevância na Pesquisa
37.38%
O objetivo desse estudo foi avaliar o efeito da distância da ponta fotoativadora na profundidade de polimerização da resina composta por meio de testes de microdureza Vickers e da análise do grau de conversão pelo método FT-Raman. O aparelho de luz halógena (500 mW/cm2) e o LED (900 mW/cm2) foram utilizados na sua intensidade convencional. O laser de argônio, na potência de 250 mW. Os tempos de fotoativação foram de 40 segundos para a luz halógena, 20 segundos para o LED e 20 e 30 segundos para o laser. E as distâncias da ponta fotoativadora foi padronizada com anéis de 3, 6 e 9 mm de altura. A resina composta micro-híbrida foi inserida em porção única, em matrizes de polipropileno pretas com as espessuras de 1 a 4 mm. Os corpos-de-prova foram armazenados por uma semana a seco, a 37ºC em recipientes protegidos da luz. Os dados da microdureza e do grau de conversão foram analisados separadamente por meio da análise de variância e teste de Tukey, com nível de significância de 5% e depois correlacionados pelo teste de correlação de Pearson. Os resultados obtidos permitiram concluir que: o aumento da distância da fonte de luz promoveu uma diminuição nos valores de microdureza e no grau de conversão para todos os tipos de fontes de luz estudados e o mesmo ocorreu com o aumento da espessura de resina composta diminuindo também os valores de microdureza e grau de conversão. Houve uma alta correlação entre a análise PDM (porcentagem de dureza máxima) e a análise do grau de conversão e entre o teste de microdureza e a análise do grau de conversão. As fontes de fotoativação estudadas promoveram grau de conversão e microdureza correspondentes entre si...

Avaliação da microdureza e desgaste por escovação simulada de uma resina composta, em função de diferentes fontes de luz e energias de ativação; Influence of different light sources and energy densities on a resin composite microhardness and wear resistance after simulated toothbrushing abrasion test

Nunes, Margareth Calvo Pessutti
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 12/12/2006 PT
Relevância na Pesquisa
37.41%
Este estudo in vitro teve como objetivo avaliar comparativamente a microdureza superficial e o desgaste de uma resina composta, FiltekTM Z-250 (3M/ESPE), sob influência de diferentes fontes de luz (LED Ultrablue IS - DMC, LED Ultralume 5 - Ultradent e halógena VIP - BISCO), com variação das densidades de potência (300, 600 e acima de 800mW/cm2) e energia (6, >8, 12, >16, 24, >32 J/cm2). Espécimes retangulares (15 x 5 x 4 mm) foram polimerizados, conforme os fatores de variação, totalizando 15 grupos (n=6). Em seguida receberam acabamento e polimento com lixas de abrasividade decrescente (300, 600, 1200 e 2000), sendo armazenados em água deionizada a 37º C por sete dias. As mensurações da microdureza Knoop foram realizadas com auxílio do Microdurômetro Shimadzu HMV-2, com carga estática de 100g por 5s nas superfícies de topo e lateral (50µm da superfície). Posteriormente os espécimes foram levados à máquina de ensaios para simulação de desgaste por escovação, utilizando-se escovas dentais macias (Oral B 30 Indicator) e creme dental (Colgate) diluído em água deionizada na proporção de 1:2 em peso. Ao final de 100.000 ciclos, a dureza da superfície lateral foi novamente mensurada e o desgaste da área escovada foi determinado por meio de perfilometria (Hommel Tester T 1000 basic - Hommelwerke). Os dados de microdureza e desgaste superficial obtidos foram submetidos à análise de variância (ANOVA) e teste de Tukey (p<0...

Influência dos níveis de energia do laser Er:YAG na capacidade de ablação, microdureza e morfologia da dentina superficial e profunda; Influence of Er:YAG laser energy levels on ablation rate, microhardness and morphology of superficial and deep dentin

Chinelatti, Michelle Alexandra
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 18/03/2008 PT
Relevância na Pesquisa
37.49%
O objetivo do presente estudo foi avaliar in vitro a influência dos níveis de energia do laser de Er:YAG para preparo cavitário na capacidade de ablação, microdureza e morfologia da dentina superficial e profunda. Foram selecionados 72 terceiros molares humanos hígidos, que tiveram as raízes removidas e as coroas seccionadas no sentido vestibulo-lingual, obtendo-se 144 fragmentos. Os fragmentos foram alocados aleatoriamente em 2 grupos: dentina superficial (as faces oclusais foram lixadas até 1 mm abaixo da junção amelodentinaria - JAD) e dentina profunda (2 mm abaixo da JAD). Posteriormente, cada grupo foi subdividido em 6 subgrupos (n=12) de acordo com as energias do laser de Er:YAG utilizadas (160, 200, 260, 300 ou 360 mJ, ou controle- sem irradiação). Para avaliar a capacidade de ablação, a massa (mg) de cada fragmento foi obtida antes e depois da irradiação. Para a realização do teste de microdureza Knoop, após a irradiação as cavidades foram incluídas em resina acrílica e seccionadas longitudinalmente. As marcações (10 g; 20 s) foram localizadas a 20, 40, 60, 80, 100 e 200 µm abaixo da parede de fundo do preparo ou da margem superior dos espécimes do grupo controle. A análise morfológica foi realizada em MEV. Os valores de perda de massa e microdureza foram analisados individualmente pelos testes de ANOVA e Fisher (α=5%). Os resultados revelaram um aumento gradativo e significante na perda de massa quando se aumentou a energia do laser utilizada...

Estudo dos efeitos de algumas soluções irrigadoras sobre a microdureza dentinária e capacidade de remoção da smear layer; Study on the effects of some irrigating solutions on dentine microhardness and smear layer removal

Guerisoli, Danilo Mathias Zanello
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 07/01/2008 PT
Relevância na Pesquisa
37.44%
Este trabalho estudou os efeitos de algumas soluções irrigadoras sobre a microdureza dentinária e capacidade de remoção da smear layer. As soluções testadas foram: soro fisiológico, hipoclorito de sódio a 2,5%, EDTA a 15% em pH 7,3, EDTA a 15% em pH 9,0, ácido etileno diamino di-succínico (EDDS), Smear Clear® e BioPure MTAD®. Para o estudo de microdureza, 70 fragmentos de dentina medindo 5x5 mm foram obtidos do terço médio de hemissecções radiculares de incisivos bovinos, sendo separados aleatoriamente em sete grupos. A microdureza Knoop inicial da dentina foi aferida por meio de microdurômetro acionado com uma carga de 25 g por 15 s. As amostras eram então tratadas pela imersão nas soluções experimentais por um minuto, após o qual tinham a sua microdureza mensurada. Após mais quatro minutos de imersão nas soluções testadas, os valores de microdureza eram novamente registrados. Os valores de microdureza iniciais e após cada imersão nas soluções testadas foram então submetidos à análise estatística (two-way ANOVA). Para a avaliação da capacidade de remoção da smear layer, 35 raízes de incisivos bovinos foram separadas aleatoriamente em sete grupos e instrumentadas pela técnica step-back. Cada grupo recebeu um tipo de solução irrigadora experimental...

Influência de técnicas de clareamento dental na microdureza superficial e alteração de cor de resinas compostas; Influence of bleaching techniques on the color change and surface microhardness of composites resins

Turrini Neto, Pedro
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 28/03/2008 PT
Relevância na Pesquisa
37.38%
O presente trabalho tem por objetivo avaliar os efeitos do clareamento caseiro, com peróxido de carbamida 10%, e clínico, com peróxido de carbamida 37%, na microdureza e alteração de cor de duas resinas compostas (Z250 e Supreme). Foram confeccionados 100 espécimes, 60 para microdureza e 40 para alteração de cor, com 6mm de diâmetro e 2mm de espessura, em resina composta. A matriz foi preenchida em um único incremento e polimerizada por 20s. Na seqüência os espécimes foram polidos com lixas #1200 e com pasta diamantada. Realizou-se então a primeira medição de dureza e cor dos espécimes. A seguir, para o estudo de cor foi realizada o manchamento com café durante 7 dias e então realizado uma segunda medição da cor. Os espécimes foram divididos aleatoriamente em 3 grupos para microdureza e 2 grupos para cor (n=10) de acordo com o tratamento clareador. Para o clareamento clínico foram realizadas três sessões com intervalo de 7 dias entre elas. Para o clareamento caseiro foram feitas 4h de aplicações diárias durante 14 dias. Nos intervalos entre os procedimentos de clareamentos os espécimes foram armazenados em saliva artificial a 37ºC. Após o final do clareamento nova medição de microdureza e cor foram realizadas. Os dados obtidos foram submetidos ANOVA e Fisher (p<0...

Avaliação da microdureza de cimentos resinosos dual utilizados na cimentação de pinos de fibra de vidro submetidos a diferentes condições de polimerização e armazenamento em água; Evaluation of the microhardness of dual cure resin cements in the luting of fiberglass posts under different conditions of cure and water storage

Ramos, Marcelo Barbosa
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 29/04/2009 PT
Relevância na Pesquisa
37.47%
Este trabalho teve como objetivo avaliar a microdureza de dois cimentos resinosos de polimerização dual (RelyX U100®, 3M-ESPE e Panavia F 2.0®, Kuraray), empregados na cimentação de pinos de fibra de vidro (Fibrekor-Jeneric® Pentron) variando o modo de polimerização em químico, fotoativação imediata ou tardia após 5min através de luz halógena, avaliando também o efeito do armazenamento em água deionizada por três meses. Este trabalho testou as seguintes hipóteses nulas: não há diferença nos valores de microdureza entre os cimentos, modo de polimerização, efeito do armazenamento e entre os terços radiculares. Sessenta raízes de incisivos bovinos, com 16mm de comprimento cérvico-apical, tiveram seus condutos obturados e, posteriormente, preparados para cimentação do pino intracanal. Os espécimes foram divididos em 6 grupos (n = 10), cada um subdividido em 2 subgrupos com 5 espécimes para cada cimento. Os pinos foram cimentados de acordo com o protocolo descrito por cada fabricante. No grupo A1, os espécimes foram mantidos em ambiente à prova de luz para que ocorresse apenas a polimerização química. No grupo B1, os espécimes foram cimentados e submetidos à fotoativação imediata, e, no grupo C1...

Influência das dimensões e do modo de fotoativação do corpo de prova sobre os testes de sorção, de solubilidade e de microdureza Knoop; Influence of the specimen dimensions and mode of photoactivation on the tests of sorption, solubility and Knoop microhardness

Silva, Luciana Maria da
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 11/02/2011 PT
Relevância na Pesquisa
37.38%
O presente estudo avaliou a influência das dimensões e das formas de fotoativação do corpo de prova através dos testes de sorção, de solubilidade e de microdureza Knoop. Este trabalho foi dividido em duas fases. Na primeira fase, corpos de prova de um compósito experimental medindo 15 mm de diâmetro x 1 mm de espessura foram confeccionados usando uma matriz de teflon bipartida, sendo o compósito inserido em um único incremento e, em seguida, planificado por uma tira de poliéster aderida a uma placa de vidro. Todos os grupos tiveram as mesmas dimensões, porém, foram fotopolimerizados de três maneiras diferentes: G1- Com cinco exposições de cada lado do corpo de prova, de acordo com o padrão especificado pela ISO 4049; G2- Retirando a ponta do aparelho fotoativador de forma que a luz atingisse toda a superfície do espécime e G3- Distanciando a ponta do fotopolimerizador 1,5 cm com o mesmo intuito (n=5). Anova (p<0,05) e teste de Tukey 5% para diferenciação das médias não mostraram diferenças estatísticas significativas entre os grupos para o teste de sorção (p=0,517). Os valores em g/mm3 com seus desvios padrão foram: G1=22,58±1,20; G2=23,51±0,61 e G3=22,16±1,39. Já para o teste de solubilidade foram encontradas diferenças estatísticas significativas (p=0...

Estudo do shelf life da quitosana armazenada em diferentes tipos de embalagem, por meio de colorimetria e análise da microdureza dentinária; Study of the shelf life of chitosan stored at different flasks through colorimetry and dentine microhardness

Bordin, Ângelo Rafael de Vito
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 07/04/2014 PT
Relevância na Pesquisa
37.44%
O objetivo do presente trabalho foi estudar, por meio da técnica de titulação colorimétrica e análise da microdureza dentinária, o shelf life da solução de quitosana 0,2% armazenada em frascos de vidro e plástico. Trinta caninos superiores humanos tiveram as coroas desprezadas e a porção cervical das raízes seccionada, obtendo-se 3 cortes. O segundo e terceiro cortes foram divididos ao meio e incluídos em resina acrílica resultando em 4 corpos de prova por dente. A solução de quitosana 0,2% (pH 3,2) foi preparada e distribuída em 3 frascos iguais de vidro (v1, v2 e v3) e em 3 de plástico (p1, p2 e p3) para realização dos testes em triplicata. Os testes de microdureza e colorimetria foram realizados durante seis meses nos períodos de 0, 7, 15, 30, 45, 60, 90, 120, 150 e 180 dias após o aviamento da solução. Para a mensuração da microdureza Knoop utilizou-se carga de 10 gramas por 15 segundos. O corpo de prova recebeu 50 μL da solução teste por 5 minutos e, após lavagem e secagem foi levado para mensuração. A análise foi realizada com as soluções v1, p1, EDTA 17% e água destilada (controle); v2, p2, EDTA 17% e controle; v3, p3, EDTA 17% e controle, para cada tempo proposto. Foram realizadas 3 endentações com espaço de 200 μm. As mensurações foram anotadas e arquivadas em um banco de dados. Para o teste da colorimetria utilizou-se uma solução padrão de carbonato de cálcio 0...

Effect of thermal cycling and disinfection on microhardness of acrylic resin denture base

Goiato, Marcelo Coelho; Dos Santos, Daniela Micheline; Baptista, Gabriella Trunckle; Moreno, Amália; Andreotti, Agda Marobo; Dekon, Stéfan Fiuza de Carvalho
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 203-207
ENG
Relevância na Pesquisa
37.41%
The purpose of this study was to investigate the effect of thermal cycling and disinfection on the microhardness of acrylic resins denture base. Four different brands of acrylic resins were evaluated: Onda Cryl, QC 20, Classico and Lucitone. Each brand of acrylic resin was divided into four groups (n = 7) according to the disinfection method (microwave, Efferdent, 4% chlorhexidine and 1% hypochlorite). Samples were disinfected during 60 days. Before and after disinfection, samples were thermal cycled between 5-55 °C with 30-s dwell times for 1000 cycles. The microhardness was measured using a microhardener, at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). The microhardness values of all groups reduced over time. QC-20 acrylic resin exhibited the lowest microhardness values. At B and T1 periods, the acrylic resins exhibited statistically greater microhardness values when compared to D and T2 periods. It can be concluded that the microhardness values of the acrylic resins denture base were affected by the thermal cycling and disinfection procedures. However, all microhardness values obtained herein are within acceptable clinical limits for the acrylic resins. © 2013 Informa UK Ltd.

Effect of final irrigation protocols on microhardness and erosion of root canal dentin

Aranda-Garcia, Arturo Javier; Kuga, Milton Carlos; Chavéz-Andrade, Gisselle Moraima; Kalatzis-Sousa, Natália Guimarães; Hungaro Duarte, Marco Antonio; Faria, Gisele; Reis Só, Marcus Vinicius; Faria-Junior, Norberto Batista
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 1079-1083
ENG
Relevância na Pesquisa
37.41%
The aim of this study was to evaluate the effect of final irrigation protocols (17% EDTA, BioPure MTAD, SmearClear, and QMiX) on microhardness and erosion of root canal dentin. Fifty roots were sectioned transversely at the cement-enamel junction and each root was sectioned horizontally into 4-mm-thick slices. The samples were divided into five groups (n=10) according to the final irrigation protocol: G1: distilled water (control group); G2: 17% EDTA; G3: BioPure MTAD; G4: SmearClear; and G5: QMiX. The dentin microhardness was then measured with a load of 25 g for 10 s. Initially, the reference microhardness values were obtained for the samples without any etching. The same samples were then submitted to the final irrigation protocols. A new measure was realized and the difference between before and after the procedures was the dentin microhardness reduction. In sequence, the specimens were submitted to SEM analysis to verify the dentinal erosion. The Kruskal Wallis and Dunn tests (α=5%) were used to compare the results. The dentin microhardness decreased for all final irrigation protocols. There was no significant difference between groups 2, 3, 4, and 5 (P>0.05), but this groups presented significant dentin microhardness reduction than G1 (P<0.05). In G2...

Microhardness of starch based biomaterials in simulated physiological conditions

Alves, N. M.; Saiz-Arroyo, C.; Rodriguez-Perez, M. A.; Reis, R. L.; Mano, J. F.
Fonte: Elsevier Publicador: Elsevier
Tipo: Artigo de Revista Científica
Publicado em /01/2007 ENG
Relevância na Pesquisa
37.38%
In this work the variation of the surface mechanical properties of starch-based biomaterials with immersion time was followed using microhardness measurements. Two blends with very distinct water uptake capabilities, starch/cellulose acetate (SCA) and starch/poly- (e-caprolactone) (SPCL), were immersed in a phosphate buffer solution (PBS) at 37.5 C for various times. The microhardness of the blends decreased significantly ( 50% for SPCL and 94% for SCA), within a time period of 30 days of immersion, reflecting the different hydrophilic character of the synthetic components of the blends. The dependence of microhardness on the applied loading time and load was also analysed and showed a power law dependency for SCA. Water uptake and weight loss measurements were performed for the same immersion times used in the microhardness experiments. The different swelling/degradation behaviour presented by the blends was related to the respective variation in microhardness. Moreover, complementary characterization of the mechanical properties of SCA and SPCL was accomplished by dynamic mechanical analysis (DMA) and creep measurements. Microhardness measurements proved to be a useful technique for characterizing the mechanical behaviour near the surface of polymeric biomaterials...

Effect of Super-Oxidized Water, Sodium Hypochlorite and EDTA on Dentin Microhardness

Ghisi,Alexandre Corrêa; Kopper,Patrícia Maria Poli; Baldasso,Flávia E. R.; Stürmer,Caroline P.; Rossi-Fedele,Giampiero; Steier,Liviu; Figueiredo,José Antonio Poli de; Morgental,Renata Dornelles; Vier-Pelisser,Fabiana Vieira
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/10/2014 EN
Relevância na Pesquisa
37.38%
The present study aimed to evaluate the influence of the following irrigating solutions on the microhardness of root canal dentin: 2% sodium hypochlorite (2NaOCl), 5% sodium hypochlorite (5NaOCl), super-oxidized water (400 ppm Sterilox - Sx) and 17% EDTA (E). Eighty roots from bovine incisors were randomly divided into 8 groups (n=10): 2NaOCl, 5NaOCl, Sx, and 2NaOCl + E, 5NaOCl + E, Sx + E (associated with E as final irrigant for 5 min), E solely and distilled water (dH2O) as the negative control. Root canal preparation was performed by hand instruments, using one of the irrigation protocols for 30 min. Then, 5 mm of the cervical root third were cut out from each sample and subjected to the Vickers microhardness test, at two points, one at approximately 500-1000 µm from the root canal lumen (distance 1), and the other at approximately 500-1000 µm from the external root surface (distance 2). Data were analyzed by Wilcoxon and Kruskal-Wallis tests at 5% significance level. Microhardness values at distance 1 were significantly lower than those at distance 2 for all groups, except 5NaOCl and 5NaOCl + E groups (p>0.05). EDTA showed the lowest microhardness values. However, no statistically significant difference was detected among groups at distance 1 and EDTA was significantly different only from Sx at distance 2. In conclusion...

Effect of light curing unit on resin-modified glass-ionomer cements: a microhardness assessment

CEFALY, Daniela Francisca Gigo; MELLO, Liliam Lucia Carrara Paes de; WANG, Linda; LAURIS, José Roberto Pereira; D'ALPINO, Paulo Henrique Perlatti
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
37.41%
OBJECTIVE: To evaluate the microhardness of resin-modified glass-ionomer cements (RMGICs) photoactivated with a blue light-emitting diode (LED) curing light. MATERIAL AND METHODS: Thirty specimens were distributed in 3 groups: Fuji II LC Improved/GC (RM1), Vitremer/3M ESPE (RM2) and Filtek Z250/ 3M ESPE (RM3). Two commercial light-curing units were used to polymerize the materials: LED/Ultrablue IS and a halogen light/XL3000 (QTH). After 24 h, Knoop microhardness test was performed. Data were submitted to three-way ANOVA and Tukey's test at a pre-set alpha of 0.05. RESULTS: At the top surface, no statistically significant difference (p>0.05) in the microhardness was seen when the LED and QTH lights were used for all materials. At the bottom surface, microhardness mean value of RM2 was significantly higher when the QTH light was used (p<0.05). For RM1, statistically significant higher values (p<0.05) were seen when the LED light was used. No statistically significant difference (p>0.05) was seen at the bottom surface for RM3, irrespective of the light used. Top-to-bottom surface comparison showed no statistically significant difference (p>0.05) for both RMGICs, regardless of the light used. For RM3, microhardness mean value at the top was significantly higher (p<0.05) than bottom microhardness when both curing units were used. CONCLUSION: The microhardness values seen when a LED light was used varied depending on the restorative material tested.

Effect of light curing unit on resin-modified glass-ionomer cements: a microhardness assessment

Cefaly,Daniela Francisca Gigo; Mello,Liliam Lucia Carrara Paes de; Wang,Linda; Lauris,José Roberto Pereira; D'Alpino,Paulo Henrique Perlatti
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2009 EN
Relevância na Pesquisa
37.41%
OBJECTIVE: To evaluate the microhardness of resin-modified glass-ionomer cements (RMGICs) photoactivated with a blue light-emitting diode (LED) curing light. MATERIAL AND METHODS: Thirty specimens were distributed in 3 groups: Fuji II LC Improved/GC (RM1), Vitremer/3M ESPE (RM2) and Filtek Z250/ 3M ESPE (RM3). Two commercial light-curing units were used to polymerize the materials: LED/Ultrablue IS and a halogen light/XL3000 (QTH). After 24 h, Knoop microhardness test was performed. Data were submitted to three-way ANOVA and Tukey's test at a pre-set alpha of 0.05. RESULTS: At the top surface, no statistically significant difference (p>0.05) in the microhardness was seen when the LED and QTH lights were used for all materials. At the bottom surface, microhardness mean value of RM2 was significantly higher when the QTH light was used (p<0.05). For RM1, statistically significant higher values (p<0.05) were seen when the LED light was used. No statistically significant difference (p>0.05) was seen at the bottom surface for RM3, irrespective of the light used. Top-to-bottom surface comparison showed no statistically significant difference (p>0.05) for both RMGICs, regardless of the light used. For RM3, microhardness mean value at the top was significantly higher (p<0.05) than bottom microhardness when both curing units were used. CONCLUSION: The microhardness values seen when a LED light was used varied depending on the restorative material tested.

The effect of different light-curing units on tensile strength and microhardness of a composite resin

Franco,Eduardo Batista; Santos,Patrícia Aleixo dos; Mondelli,Rafael Francisco Lia
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2007 EN
Relevância na Pesquisa
37.41%
The aim of this study was to evaluate the influence of different light-curing units on the tensile bond strength and microhardness of a composite resin (Filtek Z250 - 3M/ESPE). Conventional halogen (Curing Light 2500 - 3M/ESPE; CL) and two blue light emitting diode curing units (Ultraled - Dabi/Atlante; UL; Ultrablue IS - DMC; UB3 and UB6) were selected for this study. Different light intensities (670, 130, 300, and 600 mW/cm², respectively) and different curing times (20s, 40s and 60s) were evaluated. Knoop microhardness test was performed in the area corresponding to the fractured region of the specimen. A total of 12 groups (n=10) were established and the specimens were prepared using a stainless steel mold composed by two similar parts that contained a cone-shaped hole with two diameters (8.0 mm and 5.0 mm) and thickness of 1.0 mm. Next, the specimens were loaded in tensile strength until fracture in a universal testing machine at a crosshead speed of 0.5 mm/min and a 50 kg load cell. For the microhardness test, the same matrix was used to fabricate the specimens (12 groups; n=5). Microhardness was determined on the surfaces that were not exposed to the light source, using a Shimadzu HMV-2 Microhardness Tester at a static load of 50 g for 30 seconds. Data were analyzed statistically by two-way ANOVA and Tukey's test (p<0.05). Regarding the individual performance of the light-curing units...

Evaluation of radiopacity and microhardness of composites submitted to artificial aging

Cruvinel,Diogo Rodrigues; Garcia,Lucas da Fonseca Roberti; Casemiro,Luciana Assirati; Pardini,Luiz Carlos; Pires-de-Souza,Fernanda de Carvalho Panzeri
Fonte: ABM, ABC, ABPol Publicador: ABM, ABC, ABPol
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/09/2007 EN
Relevância na Pesquisa
37.38%
The purpose of this study was to assess the radiopacity and microhardness of different types of resin-based composites (RBC - hybrid; microhybrid; flowable; cement and polyacid modified) before and after being submitted to artificial accelerated aging. Fifty specimens (7 mm in diameter and 2 mm thick) were fabricated, 10 for each material. The specimens were light-cured and submitted to radiopacity and microhardness tests. After obtaining initial radiopacity and microhardness values, the specimens were taken to the artificial accelerated aging, and new measurement of radiopacity and microhardness of the samples was performed. Data were submitted to statistical analysis (Student's t-test - p < 0.05). None of the materials studied showed changes in radiopacity after artificial accelerated aging. There was a significant decrease in microhardness for the microhybrid and polyacid-modified RBC´s. This study suggests that radiopacity remains unaltered after materials are submitted to artificial accelerated aging. Microhardness, however, may vary due to plasticization of the aged RBC matrix.

Microhardness evaluation around composite restorations using fluoride-containing adhesive systems

Magalhães,Cláudia Silami de; Hara,Anderson Takeo; Turssi,Cecilia Pedroso; Serra,Mônica Campos; Giannini,Marcelo
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/09/2005 EN
Relevância na Pesquisa
37.41%
The purpose of this study was to evaluate the microhardness of dental enamel around composite restorations bonded with fluoride-containing adhesive systems (FCAS), after thermo- and pH-cycling protocols. Standardized cylindrical cavities were prepared on enamel surfaces of 175 dental fragments, which were randomly assigned into seven experimental groups (n=25). Four groups used FCAS: Optibond Solo (OS); Prime&Bond 2.1 (PB); Syntac Sprint (SS) and Tenure Quick (TC). Other groups consisted of "Sandwich" technique restoration (STR) (glass ionomer liner + hydrophobic adhesive resin /restorative composite) or used Single Bond with (SB) or without (SBWC) cycling protocols. Adhesive systems were applied according to manufacturers' instructions and cavities were restored with a microfilled composite (Durafill VS). After finishing and polishing, all groups were submitted to 1,000 thermal cycles (5 ºC and 55 ºC) and to demineralization (pH 4.3) and remineralization (pH 7.0) cycling protocols, except for SBWC group. The Knoop microhardness of enamel surfaces were measured around restorations. Indentations were recorded at 150, 300 and 450-mm from the cavity wall. Data were analyzed by two-way ANOVA and Duncan's Test (a=0.05%). Means ± SD of enamel microhardness for the groups were (Kg/mm²): SBWC: 314.50 ± 55.93ª ; SB: 256.78 ± 62.66b; STR: 253.90 ± 83.6b; TQ: 243.93 ± 68.3b; OS: 227.97 ± 67.1c; PB: 213.30 ± 91.3d; SS: 208.73 ± 86.6d. Means ± SD of microhardness for the distances 150...

Avaliação da microdureza ao redor de restaurações de compósito confeccionadas com sistemas adesivos contendo fluoretos; Microhardness evaluation around composite restorations using fluoride-containing adhesive systems

Magalhães, Cláudia Silami de; Hara, Anderson Takeo; Turssi, Cecilia Pedroso; Serra, Mônica Campos; Giannini, Marcelo
Fonte: Universidade de São Paulo. Faculdade de Odontologia de Bauru Publicador: Universidade de São Paulo. Faculdade de Odontologia de Bauru
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; Formato: application/pdf
Publicado em 01/09/2005 ENG
Relevância na Pesquisa
37.41%
O objetivo deste estudo foi avaliar a microdureza do esmalte dental ao redor de restaurações em compósito que utilizaram sistemas adesivos contendo fluoretos (FCAS), após tratamento dessas superfícies restauradas aos protocolos de ciclagem térmica e pH. Cavidades cilíndricas padronizadas foram preparadas em 175 superfícies de esmalte de fragmentos dentais, os quais foram aleatoriamente divididos em sete grupos (n=25). Quatro grupos utilizaram os FCAS: Optibond Solo (OS); Prime&Bond 2.1 (PB); Syntac Sprint (SS) e Tenure Quick (TC). Outros grupos consistiram em restaurações "Sandwich" (STR - ionômero de vidro como base + restauração em composíto) ou utilizaram Single Bond com (SB) ou sem (SBWC) ciclagens. Os sistemas adesivos foram aplicados segundo as instruções dos fabricantes e as cavidades restauradas com compósito microparticulado (Durafill VS). Após o acabamento e polimento, todos grupos foram submetidos a 1.000 ciclos térmicos (5 ºC e 55 ºC) e a um protocolo de ciclagem de pH (desmineralização-pH 4,3 e remineralização-pH 7,0), exceto para o grupo SBWC. A microdureza das superfícies de esmalte foi mensurada ao redor das restaurações. Indentações foram feitas nas distâncias de 100, 300 and 450-mm da parede cavitária. Os dados foram analisados pela ANOVA (2 fatores) and Teste de Duncan (5%). Os valores médios ± DP da microdureza do esmalte para os grupos foram (Kg/mm²): SBWC: 314...