Página 1 dos resultados de 1340 itens digitais encontrados em 0.021 segundos

Influence of Microstructures on Polarization Resistance and Hydrogen-Induced Cracking of a Micro-Alloyed Steel Submitted to Different Cooling Rates

GONZALEZ, M. R.; Araujo, Denny Serejo Martins de; Goldenstein, Helio; ALONSO-FALLEIROS, N.
Fonte: JOURNAL IRON STEEL RESEARCH EDITORIAL BOARD Publicador: JOURNAL IRON STEEL RESEARCH EDITORIAL BOARD
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
46.03%
The effect of different microstructures on the polarization resistance (Rp) and the hydrogen-induced cracking (HIC) of a micro-alloyed steel austenitized and submitted to different cooling rates was studied. Samples 19.1 x 6 x 2 mm, containing the whole thickness of the plate were extracted from a 20 mm plate and heat treated on a quenching dilatometer, were submitted to Rp and HIC corrosion tests. Both Rp and HIC tests followed as close as possible ASTM G59 and NACE standard TM0284-2003, in this case, modified only with regard to the size of the samples. Steel samples transformed from austenite by a slow cooling (cooling rate of 0.5 degrees C.s(-1)) showed higher susceptibility to hydrogen-induced cracking, with large cracks in the middle of the sample propagating along segregation bands, corresponding to the centerline of the plate thickness. For cooling rates of 10 degrees C.s(-1), only small cracks were found in the matrix and micro cracks nucleated at non-metallic inclusions. For higher cooling rates (40 degrees C.s(-1)) very few small cracks were detected, linked to non-metallic inclusions. This result suggests that structures formed by polygonal structures and segregation bands (were cutectoid microconstituents predominate) have higher susceptibility to HIC. Structures predominantly formed by acicular ferrite make it difficult to propagate the cracks among non-oriented and interlaced acicular ferrite crystals. Smaller segregation bands containing eutectoid products also help inhibit cracking and crack propagation; segregation bands can function as pipelines for hydrogen diffusion and offer a path of stress concentration for the propagation of cracks...

Efeitos do sistema de resfriamento adiabático evaporativo em free-stall sobre a produção, fisiologia, comportamento e ocorrência de mastite em vacas em lactação.; Effects of the adiabatic evaporative cooling system in free-stall on the production, physiological, behavior on the occurrence of mastitis in dairy cows.

Arcaro, Juliana Rodrigues Pozzi
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 02/08/2005 PT
Relevância na Pesquisa
36.08%
O trabalho teve como objetivo avaliar a eficiência do sistema de resfriamento adiabático evaporativo (SRAE), acionado em diferentes horários, em instalação do tipo free-stall e a interação entre o ambiente e a ocorrência de mastite bem como seus reflexos nas respostas produtivas, fisiológicas e comportamentais de vacas em lactação. Foram utilizadas 28 vacas em lactação, multíparas, das raças Holandesa Preta e Branca e Parda Suíça, com produção média diária de 23 kg de leite/animal por dia distribuídas em um delineamento inteiramente casualisado. O período experimental de 56 dias teve início em 20 de janeiro de 2003. Os tratamentos foram: controle (sem SRAE); Dia (SRAE acionado das 7 às 19 h); Noite (SRAE acionado das 19 às 7 h) e 24 horas (SRAE acionado durante 24h). Os equipamentos foram acionados toda vez que a temperatura atingiu 22ºC. A temperatura de bulbo seco (TBS), umidade relativa do ar (UR) e a temperatura de globo negro (TGN) foram mensuradas ao longo das 24 horas. A freqüência respiratória (FR), a temperatura retal (TR) e temperatura do pelame (TP) foram tomadas duas vezes por semana às 7, 13 e 21 h. A ordenha foi realizada às 7 e às 19 h. Amostragens semanais de leite e sangue foram realizadas para análise da composição do leite (gordura...

Desenvolvimento de um atuador de posição baseado em liga de memória de forma com resfriamento forçado.; Development of a position actuator based on a shape memory alloy with forced cooling.

Romano, Roberto
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 27/11/2006 PT
Relevância na Pesquisa
36.1%
As ligas com memória de forma (Shape Memory Alloy - SMA) consistem em um grupo de materiais metálicos que possuem a habilidade de retornar a um formato ou tamanho previamente definido quando submetidas a um ciclo térmico adequado, devido a alterações em sua estrutura cristalina. Esta mudança não é um processo termodinamicamente reversível, apresentando, conseqüentemente, histerese. Portanto, a característica principal destes materiais é a habilidade de sofrer grandes deformações e, em seguida, recuperar sua forma original quando a carga é removida ou o material é aquecido. Assim, pode-se utilizar esse fenômeno para construir atuadores leves e silenciosos, como verdadeiros músculos metálicos. O desenvolvimento de atuadores com as SMAs apresenta grande atrativo para diversos campos da engenharia, principalmente na área de robótica, substituindo os atuadores convencionais de grande peso e ruidosos, como motores, válvulas solenóides, etc. Entretanto, para o bom desempenho de atuadores SMA requer-se um complexo sistema de controle e resfriamento, reduzindo-se o tempo de resposta do atuador e minimizando-se os efeitos da histerese. Neste trabalho, propõe-se um inovador sistema de resfriamento, baseado em pastilha termo-elétrica (efeito Seebeck-Peltier). Este método possui a vantagem de ser mais compacto e simples que outros métodos de resfriamento forçado. Um modelo matemático completo foi também desenvolvido...

Determinação de índices de ajuste no controle de sistema de condicionamento de ar do tipo 'teto frio'.; Determination of adjustment indexes in control of "cooling ceiling" air conditioning system.

Ikeda, Marcelo Jun
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 14/05/2008 PT
Relevância na Pesquisa
36.09%
O presente trabalho é um estudo para a determinação de índices de ajuste em medidas efetuadas por sensores de temperatura do ar utilizadas em algoritmos de controle do sistema de automação do sistema de condicionamento de ar do tipo "Teto Frio". É um trabalho experimental baseado na coleta de dados de diversas variáveis ambientais em um laboratório que utiliza este tipo de sistema. Esse laboratório possui um sistema de climatização misto composto por circuitos de água gelada que percorre serpentinas instaladas em placas metálicas de forro, para troca de calor por radiação (retirada de calor sensível) e circuitos de ar, com distribuição de ar pelo teto, para troca de calor por convecção (retirada de calor latente). Seu funcionamento é controlado por um sistema de automação (hardware e software) específico. Este estudo pretende determinar índices de ajuste que, introduzidos nos algoritmos de controle do sistema de automação, corrijam as leituras de temperatura do ar realizadas no ambiente por sensores do sistema posicionados em locais que, embora esteticamente sejam os mais adequados, funcionalmente, não o são. Os resultados, concluídos através de método estatístico e recursos de representação gráfica...

Qualidade e conservação de pessegos com utilização de 1-MCP e resfriamento rapido; Quality and peach conservation with the use of 1-MCP and cooling

Luciana Calore de Barros Pinto
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 25/02/2005 PT
Relevância na Pesquisa
36.12%
As perdas pós-colheita variam entre os diversos produtos vegetais, porém de modo geral entre as frutas e hortaliças tem-se perdas da ordem de 30-50%. Tais perdas estão fundamentadas ao seu manuseio inadequado desde o momento da colheita até o consumo final. Assim, este trabalho tem como objetivo a aplicação do 1-metilciclopropeno (1-MCP), do resfriamento rápido com ar-forçado (RR), e do armazenamento refrigerado (AR) em pêssegos a fim de avaliar seus efeitos no processo de amadurecimento desta fruta. Os parâmetros avaliados no julgamento da qualidade foram as análises fisiológicas como a perda de massa fresca, a cor de fundo, a firmeza, o pH, a acidez titulável, os sólidos solúveis, o ?Ratio? e a produção de CO2 e etileno, e análises sensoriais como a cor, a textura e o sabor. O experimento foi dividido em duas etapas. Na primeira etapa testou-se as concentrações de 30; 60 e 90nl l-1 de 1-MCP aplicado nas temperaturas de 0 e 20ºC; as frutas não tratadas com 1- MCP foram denominadas de controle, para as duas temperaturas estudadas. A concentração de 90nl l-1 de 1-MCP à 0ºC apresentou menor atividade respiratória nas frutas, sendo este tratamento selecionado para ser combinado com o resfriamento rápido de pêssegos na etapa seguinte. Desta forma...

Estudo de um sistema de resfriamento com ar forçado com monitoramento do consumo de energia eletrica; Study of a cooling system with air forced with monitoring of electrical energy consumption

João Carlos Teles Ribeiro da Silva
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 01/02/2010 PT
Relevância na Pesquisa
36.06%
Este trabalho consiste no estudo da implementação de um controlador clássico utilizando o método de sintonia denominado por IMC (Controle de Modelo Interno, derivado do termo inglês Internal Model Control), visando à redução do consumo de energia elétrica que decorra na adequada relação entre este consumo e tempo de esfriamento do processo de resfriamento com ar forçado. Para isto, o sistema supervisório instalado é capaz de manipular a variável de freqüência do sinal de alimentação do motor de indução trifásico do exaustor (módulo de ar forçado), para acelerar ou desacelerar a perda de calor do produto a ser resfriado por intermédio da variação da vazão de ar que perpassa a massa deste produto. Obteve-se como resultado uma redução no consumo de energia elétrica de 64% e um acréscimo de apenas 8% no tempo de resfriamento para o sistema utilizando o controlador PI/IMC (Proporcional - Integral, com método de sintonia IMC), quando comparado ao sistema em seu funcionamento nominal. Ou seja, sistema que, nominalmente, consume 2,41 kWh para resfriar o produto em 58 minutos, consume 0,87 kWh para resfriar o produto em 63 minutos quando se emprega o controlador que utiliza o método IMC. Este controlador PI/IMC é passível de ser implementado diretamente em alguns modelos comerciais de inversores de freqüência...

Análise e projeto de um sistema de controle de arrefecimento de um motor Diesel, visando à redução das emissões e consumo de combustível; Analysis and project for a control system of a diesel

Marco Antonio Iskandar
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 27/07/2011 PT
Relevância na Pesquisa
36.07%
A tecnologia de motores diesel tem sido guiada por legislações cada vez mais severas. Para cumprir com estas legislações os sistemas de controle de emissões estão se desenvolvendo rapidamente visando à disponibilização no mercado de produtos que atendam às normas de emissões, mas com economia no consumo de combustível e maior durabilidade e competitividade nos mercados internacionais, em suma melhoria na relação custo x benefício. Neste contexto, é colocada a análise e projeto de um sistema de controle de arrefecimento do motor Diesel, que objetiva controlar a temperatura de água do motor visando à economia de combustível e redução dos níveis de emissões. Assim, o presente trabalho tem como objetivo a análise e projeto de um sistema substituto ao tradicional sistema de arrefecimento (cooling) do motor Diesel disponível e comumente utilizado no mercado atualmente. O sistema mecatrônico em estudo é composto por uma bomba elétrica de água, um ventilador acionado eletricamente, uma válvula termostática eletronicamente controlada e um algoritmo de controle. Este conjunto visa propiciar um controle preciso da temperatura de água do motor Diesel, dessa forma reduzindo as emissões de poluentes e o consumo de combustível...

Forced ventilation and evaporative cooling of waiting and milking areas and its influence on the physiological and production responses of crossbred Holstein × Zebu cows

Amaral, R.S.; Chaves, Modesto; Teodoro, Sônia; Fitas da Cruz, Vasco; Baptista, Fátima J.
Fonte: Universidade de Évora Publicador: Universidade de Évora
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
36.13%
The main objective of this work was to evaluate the effect of forced ventilation and evaporative cooling on the physiological and production responses of dairy cows Holstein × Zebu. Experiments were conducted with 32 crossbred cows (Holstein × Zebu) in the same lactation phase, mean daily production of 17 kg and mean body weight of 550 kg. Four different treatments were randomly assigned to groups with eight cows each. The treatments were: Evaporative cooling in the waiting room + forced ventilation with Evaporative cooling in the milking room (NW+VNM), Evaporative cooling in the waiting room (NW), forced ventilation with Evaporative cooling in the milking room (VNM) and a control treatment without forced ventilation and evaporative cooling (CON). Experimental work was realised in a commercial farm located in the interior of Bahia State, Brazil, during 45 days in January and February. Climatic data were measured using a meteorological station. Temperature Humidity Index (THI) and Wet Bulb Globe Temperature (WBGT) were calculated. In order to study animal responses milk production, udder temperature, heart rate, respiratory rate, temperature of white and black spots and rectal temperature were measured. It was observed that the cows under VNM treatment presented higher milk production and lower udder temperature...

Climate Modelling of a Greenhouse with Proportional Environmental Control

Louro, M.; Baptista, F.J.; Mourão, I.
Fonte: ISHS Publicador: ISHS
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
36.07%
Performance of greenhouse environmental control systems can be evaluated by predictive climate models. In this work, a model for the prediction of environmental parameters such as temperature and humidity based on energy and mass balances, was developed and validated for a greenhouse controlled with a proportional environmental control system. The greenhouse is in Viveiros do Furadouro, a forestry nursery from the Altri Group, located near Óbidos, Portugal. The greenhouse under study is a Venlo greenhouse covered with glass with an area of 1632 m2 and is used for Eucalyptus globulus Labbill. vegetative propagation through minicuttings. Eucalyptus globulus is characterized by having low rooting ability and environmental control has to be very accurate and requires the use of multiple control equipments, such as heating, cooling (pad or fog), thermal/shade screens, natural and dynamic ventilation. The proportional control of each equipment, such as the fan and wet pad for cooling, is difficult and requires good knowledge of the dynamics of greenhouse environmental parameters, as well as the influence of individual equipment. However, it allows different alternatives to achieve the set points. The climate data were recorded every 8 min and were used to develop a climatic model based on energy and mass balances...

Control system for forced-air cooling of horticultural products

Silva,João C. T. R. da; Mederos,Bárbara J. T.
Fonte: Associação Brasileira de Engenharia Agrícola Publicador: Associação Brasileira de Engenharia Agrícola
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2011 EN
Relevância na Pesquisa
36.06%
This work is a study of the implementation of a classical controller using a tuning method referred to as IMC (Internal Model Control) and aimed at the reduction of electrical energy consumption by the appropriate relation between energy consumption and the cooling time with forced air. The supervisory system installed was able to manipulate the variable of frequency of the signal power of the exhaust fan engine (forced air module), to accelerate or decelerate the loss of heat from the product to be cooled by airflow variation that passes through the mass of the produce. The results demonstrated a reduction in energy consumption from 64% and an increase of only 8% in the cooling time to the system using PI/IMC (Proportional - Integral with IMC) tuning method compared with the system in its operating nominal condition. This PI/IMC control may be implemented directly in a frequency converter, without the need to purchase a computer or PLC (programmable logic controller) to run the dedicated application, increasing its economical viability.

Effects of Rapid Cooling Prior to Freezing on the Quality of Canine Cryopreserved Spermatozoa

RODENAS, Carmen; PARRILLA, Inmaculada; ROCA, Jordi; MARTINEZ, Emilio Arsenio; LUCAS, Xiomara
Fonte: The Society for Reproduction and Development Publicador: The Society for Reproduction and Development
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
36.07%
The aim of this study was to evaluate the effects of rapid cooling prior to freezing on frozen-thawed canine sperm quality. In experiment 1, centrifuged ejaculates from 6 dogs were pooled, split into 4 aliquots and cryopreserved by the Uppsala procedure using different cooling rates (control, cooling speed 18 C/90 min and average cooling rate 0.2 C/min; rapid, cooling speed 18 C/8 min and average cooling rate 2.25 C/min) in combination with 2 glycerol addition protocols (fractionated or unfractionated). In experiment 2, centrifuged ejaculates from 4 dogs were processed individually using the same cooling rates described in experiment 1 in combination with an unfractionated glycerol addition protocol. Each of the experiments was replicated 5 times. Sperm quality was evaluated after 30 and 150 min of post-thawing incubation at 38 C. Total motility (TM), progressive motility (PM) and quality of movement parameters were assessed using a computerized system, and sperm viability (spermatozoa with intact plasma and acrosome membranes) was assessed using flow cytometry (H-42/PI/FITC-PNA). Values for TM, PM, viable spermatozoa and the quality of movement parameters after thawing were not significantly affected by the cooling rate. The interaction between the cooling rate and the added glycerol protocol was not significant. There were significant differences among the males (P<0.01) in the sperm quality parameters evaluated after thawing. The interaction between the males and the cooling rate was not significant. In conclusion...

A Lab Scale Polymer Micro-Embossing Machine for Process Control Research

Ganesan, Bala; Hardt, David E.
Fonte: MIT - Massachusetts Institute of Technology Publicador: MIT - Massachusetts Institute of Technology
Tipo: Artigo de Revista Científica Formato: 25211 bytes; application/pdf
EN_US
Relevância na Pesquisa
36.16%
Micro embossing is the process of fabricating micron-sized features by plastic deformation of a work piece by means of a shaped tool or die. In our work we are concerned with hot embossing of PMMA to produce features in the 1-100 µm range, suited for micro fluidic and photonic product requirements. As with any deformation process, hot micro embossing yields products with dimensional variation. In ideal situations, several products can be manufactured repeatedly with the same machine settings and be expected to be exactly the same in every aspect with each other. In reality, final products from the same process might have variations in dimensions and material properties even if the machine settings are kept constant. These can be natural variations of the process or variations caused by external disturbances. Variations can decrease the yield of a manufacturing process and can also restrict the ultimate level of product precision attainable. Manufacturing process control entails the study of the origins of process variations and the use of this knowledge to reduce this variation under production conditions. Manufacturing process control is thus vital in establishing the ultimate cost, quality, rate and flexibility of any manufacturing process. Thus...

Controle Fuzzy e acionamento a velocidade variável de sistema resfriador de leite; Fuzzy control and variable speed drive system cooling tank

CHAVES, Eric Nery
Fonte: Universidade Federal de Goiás; BR; UFG; Mestrado em Engenharia Elétrica e de Computação; Engenharia Publicador: Universidade Federal de Goiás; BR; UFG; Mestrado em Engenharia Elétrica e de Computação; Engenharia
Tipo: Dissertação Formato: application/pdf
POR
Relevância na Pesquisa
36.12%
This work presents the application of control techniques to drive single-phase induction motors with the aim of improving the performance of cooling systems. The control system is based on Fuzzy Logic and is applied to a three-phase PWM inverter adapted to drive singlephase motors with volts per hertz technique. The main feature of the work is to control the temperature of the cooling system driven by a hermetic compressor using variable speed. A commercial milk cooling system is used to obtain the results.; O presente trabalho demonstra os efeitos da aplicação de técnicas de controle em acionamento de motores de indução monofásicos, visando à melhoria do desempenho e eficiência energética, no local onde esses motores são aplicados. O trabalho em questão trata de um sistema que engloba um controlador de temperatura baseado em Lógica Fuzzy ou Nebulosa e um conversor de frequência trifásico, chaveado no modo PWM (modulação por largura de pulsos na sigla em inglês) senoidal, com controle escalar do tipo V/f (tensão proporcional à frequência) e adaptado para utilização em motores de indução monofásicos. O objetivo geral deste trabalho é o projeto e implementação de um sistema de controle de temperatura Fuzzy...

Modeling of Cooling Channel Flow in Liquid-Propellant Rocket Engines

Pizzarelli, Marco
Fonte: La Sapienza Universidade de Roma Publicador: La Sapienza Universidade de Roma
Tipo: Tese de Doutorado
EN_US
Relevância na Pesquisa
36.09%
Ever since the development of liquid rocket engine, there has been a need to predict the peak heat flux that affects the engine material and thus to control the wall thermal behavior of rocket engine. To prevent thermal failure, the engine is generally cooled by means of a coolant that flows in passages that line the hottest part of the engine (i.e., combustion chamber and nozzle wall). This is the fluid-cooling system. If the coolant is one of the propellants, once it passes through the cooling circuit, it can be injected into the combustion chamber or it can be dumped overboard. The former case is referred to as Regenerative cooling system while the latter as dump cooling system. In case of high performance cryogenic rocket engine (such as LO2/hydrogen and LO2/methane engines) the coolant working pressure is supercritical and thus it behaves far from a liquid or a perfect gas. The fluid-cooling system (often referred to regenerative cooling because of the limited application of the dump cooling) of cryogenic rocket engines, is the technological background of this Ph.D. thesis. It is common and well confirmed practice in industry to analyze wall thermal behaviour of liquid rocket engine by means of simple and fast tools based on semi-empirical relationships. These relationships are generally calibrated by means of data collected in experimental tests of subscale engines. Industrial tools provide reasonable results but they are not able to accurately describe many phenomena that occur in the hot-wall/coolant environment...

Simulação dinâmica para avaliação de controle de um sistema de resfriamento de líquido; A dynamic simulation for the control assessment of a liquid cooling system

Saulo Fernando dos Santos Vidal
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 22/10/2012 PT
Relevância na Pesquisa
36.07%
Na maioria das indústrias químicas se faz necessário a refrigeração de equipamentos, produtos, processos, ambientes, etc. A grande desvantagem dos sistemas de refrigeração empregados nesses processos está no gasto energético envolvido, que pode representar 70% do gasto total de uma planta. Visando minimizar esses gastos, exaustivos trabalhos de pesquisa vem sendo desenvolvidos neste campo. No Laboratório de Controle e Automação de Processos da Faculdade de Engenharia Química da Unicamp, há um protótipo de um chiller utilizado em pesquisas de técnicas de modelagem e controle visando reduzir o gasto energético empregado nos sistemas de refrigeração. Com o intuito de facilitar estes estudos, este trabalho desenvolveu um modelo a partir dos simuladores comerciais ASPEN PLUS'MARCA REGISTRADA' e ASPEN DYNAMICS'MARCA REGISTRADA' capaz de representar o protótipo experimental citado. Para validação do modelo, foram utilizados dados obtidos da própria planta experimental, em diferentes condições de processo, garantindo a funcionalidade do modelo para situações diversas de funcionamento do equipamento. Uma vez validado, o modelo desenvolvido foi utilizado no estudo dinâmico do processo de refrigeração. Também foram verificadas estratégias de controle clássico e sua aplicabilidade nos sistema em questão. Está presente no trabalho o detalhamento das variáveis e parâmetros que foram utilizados na configuração...

Analysis of pumping systems for the cooling of underground transmission lines

Kočí, Paul FrantiÅ¡ek; Glicksman, Leon R.; Rohsenow, Warren Max
Fonte: MIT Energy Lab Publicador: MIT Energy Lab
Tipo: Relatório Formato: 4918938 bytes; application/pdf
EN_US
Relevância na Pesquisa
36.13%
Various pumping arrangements and their pressure profile control for forced cooling of long pipe type transmission lines were investigated. In order to overcome the extensive friction head losses and provide ample cable cooling, a number of pump stations has to be used. Since the inner line segments cannot be provided with pressure control head tanks, line blockages, flow resistance changes, flow rate changes, pump shutdowns, or other imbalances in one segment can alter the pressure profile along the entire line, and, when two head tanks are used, create transverse flow. Using experimental and analytical methods, it was determined that the pump - relief valve combination operating as a constant flow source is superior to the pump - relief valve combination operating as a constant pressure source, and that the configuration consisting of an even number of loops, each loop having the opposite flow direction from its neighbor's, is the best solution when operated with only one pressure control head tank. The simplest, and yet effective, line pressure profile control appears to be the pump bypass, which could be easily implemented on existing installations. The head tank pressure adjustment, however, is the most effective line pressure profile control scheme...

Computer optimization of the MIT advanced wet/dry cooling tower concept for power plants

Choi, Michael; Glicksman, Leon R.
Fonte: MIT Energy Laboratory Publicador: MIT Energy Laboratory
Tipo: Relatório Formato: 3677297 bytes; application/pdf
EN_US
Relevância na Pesquisa
36.08%
There is a projected water shortage problem in the electrical power industry by the end of this century. Dry and wet-dry cooling towers are going to be the solution of this problem. Our previous study on the combination of separate dry and wet cooling towers indicated that wet-dry cooling is an economical choice over all-dry cooling when some water is available but the supply is insufficient for an evaporative tower. An advanced wet-dry cooling tower concept was experimentally studied at MIT's Heat Transfer Laboratory and a computer model was developed for predicting the performance of this cooling concept. This study has determined the cost of the cross-flow type of this cooling concept in conjunction with steam electrical power plants. Aluminum is found to be economically preferable to galvanized steel as the cooling plate material. In our base case study using aluminum plates for a 1094 MWe nuclear plant at Middletown, the MIT advanced cooling concept is comparable to conventional wet-dry towers at water makeups larger than 45% and is slightly more economical at makeup larger than 50%. The incremental costs over the power production cost, 32.3 mills/Kwhr, of zero condenser system are 14, 13 and 12 percent for makeups of 45...

Resonance Control Cooling System for a Proto-Type Coupled Cavity Linac

Treml, Chrisine A.; Brown, Stanley K.; Bernardin, John D.
Fonte: Universidade Cornell Publicador: Universidade Cornell
Tipo: Artigo de Revista Científica
Publicado em 09/11/2001
Relevância na Pesquisa
46.03%
Los Alamos National Laboratory (LANL) is designing a coupled cavity linac (CCL) for the Spallation Neutron Source (SNS) being built at Oak Ridge National Laboratory (ORNL). As part of the design process, a proto-type, Hot Model, consisting of two segments of the SNS CCL was manufactured and installed at LANL. An RF source was applied to the Hot Model to determine the success of the cavity design, the effectiveness of the control algorithms and cooling systems, and the validity of the Resonance Control Cooling System (RCCS) model used during the Hot Model design. From a system controls perspective, an overview of the hot model, a description of the RCCS, and the pertinent data from the RF tests will be presented.; Comment: 3 Page Paper for procedings from and to accompany poster session for: ICALEPCS 2001 8th International Conference on Accelerator and Large Experimental Physics Control Systems San Jose, California, from November 27 - 30, 2001

The Role of Singular Control in Frictionless Atom Cooling in a Harmonic Trapping Potential

Stefanatos, Dionisis; Li, Jr-Shin
Fonte: Universidade Cornell Publicador: Universidade Cornell
Tipo: Artigo de Revista Científica
Publicado em 08/03/2011
Relevância na Pesquisa
36.06%
In this article we study the frictionless cooling of atoms trapped in a harmonic potential, while minimizing the transient energy of the system. We show that in the case of unbounded control, this goal is achieved by a singular control, which is also the time-minimal solution for a "dual" problem, where the energy is held fixed. In addition, we examine briefly how the solution is modified when there are bounds on the control. The results presented here have a broad range of applications, from the cooling of a Bose-Einstein condensate confined in a harmonic trap to adiabatic quantum computing and finite time thermodynamic processes.

An outbreak of Legionnaires disease at the Melbourne Aquarium, April 2000: investigation and case-control studies

Greig, Jane E; Carnie, John A; Tallis, G M; Ryan, Norbert J; Tan, Agnes; Gordon, Ian R; Zwolak, Bernard; Leydon, Jennie A; Guest, Charles; Hart, William G
Fonte: Australasian Medical Association Publicador: Australasian Medical Association
Tipo: Artigo de Revista Científica
Relevância na Pesquisa
36.06%
Objective: To investigate the source and risk factors associated with Australia's largest outbreak of Legionnaires' disease. Design and setting: Epidemiological and environmental investigation of cases of Legionnaires' disease associated with visits to the Melbourne Aquarium; two case-control studies to confirm the outbreak source and to investigate risk factors for infection, respectively Participants: Patients with confirmed Legionnaires' disease who visited the Melbourne Aquarium between 11 and 27 April 2000 were compared (i) with control participants from the community, and (ii) with control participants selected from other visitors to the Aquarium during this period. Main outcome measures: Risk factors for acquiring Legionnaires' disease. Results: There were 125 confirmed cases of Legionnaires' disease caused by Legionella pneumophila serogroup 1 associated with the Aquarium; 76% of patients were hospitalised, and four (3.2%) died. The Aquarium cooling towers were contaminated with this organism. Visiting the Aquarium was significantly associated with disease (odds ratio [OR], 207; 95% Cl, 73-630). The case-control study indicated that current smoking was a dose-dependent risk (multivariable OR for currently smoking > 70 cigarettes/week...