Página 1 dos resultados de 334 itens digitais encontrados em 0.007 segundos

Short implants (6 mm) installed immediately into extraction sockets: An experimental study in dogs

Bressan, Eriberto; Sivolella, Stefano; Almagro Urrutia, Zoraya; Salata, Luiz Antonio; Lang, Niklaus Peter; Botticelli, Daniele
Fonte: WILEY-BLACKWELL; MALDEN Publicador: WILEY-BLACKWELL; MALDEN
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
56.31%
Aim: To evaluate the effect of implant length (6 mm vs. 11 mm) on osseointegration (bone-toimplant contact) of implants installed into sockets immediately after tooth extraction. Material and methods: In six Labrador dogs, the pulp tissue of the mesial roots of P-3(3) was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemisectioned and the distal roots removed. Recipient sites were prepared in the distal alveolus and a 6 mm or an 11 mm long implant was installed at the test and control sites, respectively. Non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment. Results: No statistically significant differences were found between test and control sites both for hard and soft tissue parameters. The bone-to-implant contact evaluated at the apical region of the implants was similar as well. Although not statistically significant, the location of the top of the bony crest at the buccal aspect was more apical in relation to the implant shoulder at the test compared with the control sites (2.0 +/- 1.4 and 1.2 +/- 1.1 mm, respectively). Conclusions: Shorter implants (6 mm) present with equal osseointegration than do longer implants (11 mm).; ARDEC...

Three-Dimensional Finite Element Analysis of Stress Distribution on Different Bony Ridges With Different Lengths of Morse Taper Implants and Prosthesis Dimensions

Toniollo, Marcelo Bighetti; Macedo, Ana Paula; Silveira Rodrigues, Renata Cristina; Ribeiro, Ricardo Faria; Chiarello de Mattos, Maria da Gloria
Fonte: LIPPINCOTT WILLIAMS & WILKINS; PHILADELPHIA Publicador: LIPPINCOTT WILLIAMS & WILKINS; PHILADELPHIA
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
56.55%
This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment...

Estudo clínico prospectivo utilizando implantes curtos unitários posteriores; Prospective clinical trial using short implants in posterior single crows

Silveira Júnior, Clebio Domingues da
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 30/06/2011 PT
Relevância na Pesquisa
56.4%
O objetivo deste estudo foi avaliar clínica e radiograficamente implantes curtos com 5 e 6 mm de comprimento (Titamax WS Neodent/ Curitiba-Brasil) unitários instalados em região posterior de mandíbula e maxila com pouca altura óssea. Foram instalados 10 implantes em 8 pacientes devidamente selecionados a partir de critérios de inclusão pré-determinados. Os mesmos receberam carregamento protético somente após o tempo convencional de espera para a osseointegração. Seis implantes foram instalados em mandíbula e 4 implantes em maxila. Tomadas radiográficas foram realizadas para avaliação das perdas ósseas verticais e horizontais nos tempos T0 (Instalação cirúrgica), T1 (Reabertura), T2 (Instalação protética) e T3 (Acompanhamento de 6 meses). Foram avaliados parâmetros biológicos como, sangramento gengival, índice de mucosa ceratinizada, índice de placa e índice de inflamação gengival. Também foram avaliados parâmetros protéticos como proporção coroa-implante e distância mesiodistal. Apenas um implante (Titamax WS Cortical 5.0x6.0) foi perdido ainda no período de osseointegração portanto o índice de sucesso foi de 90% no período avaliado. A alteração do nível ósseo foi analisada em três períodos diferentes...

Análise fotoelástica de tensões transmitidas a implantes curtos; Photoelastic analysis of tensions transmitted to short implants

Oliveira, Janisse Martinelli Borges de
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 18/08/2011 PT
Relevância na Pesquisa
66.5%
O objetivo desse trabalho foi avaliar, pelo método fotoelástico, de que maneira cargas aplicadas sobre próteses metalocerâmicas implantossuportadas eram transmitidas a implantes de diferentes comprimentos, e como a proporção coroa/implante influenciaria essa distribuição de tensões. A partir de quatro modelos mestres em resina do tipo policarbonato foram confeccionados quatro modelos em resina fotoelástica (Araldite) simulando extremidade livre mandibular, com o dente 44 em resina (Luxatemp) e os dentes 45, 46 e 47 substituídos por implantes com 4 mm de diâmetro. O grupo 1 (G1) foi formado por 2 implantes de comprimento convencional ou longo (11 mm; Titamax Cortical CM, Neodent) substituindo o 45 e o 46, e 1 implante curto (5 mm; Ws Cortical CM, Neodent) substituindo o 47. O grupo 2 (G2) apresentava 1 implante com 11 mm (45) e 2 implantes com 5 mm (46 e 47). O grupo 3 (G3) foi reabilitado por 3 implantes de 5 mm e o grupo 4 (G4) por 3 implantes de 11 mm de comprimento. Nos grupos com implantes de 5 mm foi simulada reabsorção óssea de 4 mm de altura. Coroas metalocerâmicas unidas foram parafusadas sobre os minipilares intermediários. Foram realizados diferentes carregamentos oclusais sobre as coroas: oclusal balanceado de 150N...

Estudo sobre o comportamento biomecânico de implantes curtos com variação da espessura da cortical óssea por meio do método dos elementos finitos; Biomechanical behavior of short implants varying thickness of cortical bone by finite element method

Conde Neto, José Augusto
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 01/10/2012 PT
Relevância na Pesquisa
56.27%
Este estudo teve como objetivo analisar e comparar o comportamento biomecânico de um implante de comprimento curto com um implante de comprimento padrão, no que diz respeito às tensões ósseas ao redor do implante. Foi considerado como variável o aumento da espessura óssea cortical, em dois tipos: fino e espesso. Os modelos de elementos finitos em três dimensões (3D) foram criados a partir de uma secção de mandíbula de 20 mm, referente ao segundo pré-molar, com um implante endósseo único inserido dentro do osso esponjoso com cortical fina de 0,5 mm e cortical espessa de 2,0 mm. Uma carga oclusal vertical de 100 N e uma carga oblíqua de 40 N foram aplicadas. Os ossos cortical e esponjoso foram considerados isotrópicos e linearmente elásticos e o critério de avaliação foi o de tensões de von Mises. O implante curto utilizado foi de 4,1 mm de diâmetro por 6,0 mm de comprimento, e o implante padrão de 4,1 mm de diâmetro por 10,0 mm de comprimento (ambos da marca Straumann®). A prótese sobre o implante foi composta por um pilar sólido de 5,5 mm de altura e por uma coroa de segundo pré-molar. Conforme as simulações pelo MEF, pôde-se concluir que: 1) O aumento da espessura óssea favoreceu uma melhor distribuição das tensões...

Análise das tensões geradas por implantes curtos e convencionais reabilitados com próteses fixas unidas e isoladas, por meio do método de correlação de imagem digital; Analysis of the stresses generated by short and conventional implants rehabilitated with splinted and non-splinted fixed prosthesis by digital image correlation method

Peixoto, Raniel Fernandes
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 06/12/2013 PT
Relevância na Pesquisa
56.54%
Nos casos de perda óssea vertical severa, principalmente em áreas posteriores da mandíbula, o uso de implantes curtos associado a próteses fixas metaloplásticas esplintadas pode ser uma alternativa às cirurgias de enxerto ósseo e a melhor transmissão de tensões ao osso adjacente, respectivamente. Dentre os métodos que avaliam a distribuição de tensões em torno dos implantes, a Correlação de Imagem Digital (CID) leva vantagens no que diz respeito à possibilidade de avaliar a distribuição das tensões de forma contínua por meio de imagens obtidas ao longo do tempo, durante carregamento oclusal. Diante disso, este trabalho avaliou qualitativa e quantitativamente o desempenho biomecânico de próteses fixas metaloplásticas parafusadas, unidas e isoladas, sobre implantes de diferentes comprimentos, posicionados na região posterior da mandíbula, por meio do método de CID. A partir de quatro modelos mestres, foram confeccionados quatro modelos em resina de poliuretano F16, simulando extremidade livre mandibular, com o dente 44 em resina (Luxatemp) e os dentes 45, 46 e 47 substituídos por implantes curtos (4 x 5 mm) e/ou convencionais (4 x 11 mm). Os grupos (G) deste estudo foram: G1 (dois implantes convencionais [45 e 46] e um curto [47])...

Short implants (6 mm) installed immediately into extraction sockets: An experimental study in dogs

Bressan, Eriberto; Sivolella, Stefano; Almagro Urrutia, Zoraya; Salata, Luiz Antonio; Lang, Niklaus Peter; Botticelli, Daniele
Fonte: Wiley-Blackwell Publicador: Wiley-Blackwell
Tipo: Artigo de Revista Científica Formato: 536-541
ENG
Relevância na Pesquisa
56.29%
Aim: To evaluate the effect of implant length (6 mm vs. 11 mm) on osseointegration (bone-toimplant contact) of implants installed into sockets immediately after tooth extraction.Material and methods: In six Labrador dogs, the pulp tissue of the mesial roots of P-3(3) was removed and the root canals were filled. Flaps were elevated bilaterally, the premolars hemisectioned and the distal roots removed. Recipient sites were prepared in the distal alveolus and a 6 mm or an 11 mm long implant was installed at the test and control sites, respectively. Non-submerged healing was allowed. After 4 months of healing, block sections of the implant sites were obtained for histological processing and peri-implant tissue assessment.Results: No statistically significant differences were found between test and control sites both for hard and soft tissue parameters. The bone-to-implant contact evaluated at the apical region of the implants was similar as well. Although not statistically significant, the location of the top of the bony crest at the buccal aspect was more apical in relation to the implant shoulder at the test compared with the control sites (2.0 +/- 1.4 and 1.2 +/- 1.1 mm, respectively).Conclusions: Shorter implants (6 mm) present with equal osseointegration than do longer implants (11 mm).

Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study

Rossi, Fabio; Ricci, Emanuele; Marchetti, Claudio; Lang, Niklaus P.; Botticelli, Daniele
Fonte: Wiley-Blackwell Publicador: Wiley-Blackwell
Tipo: Artigo de Revista Científica Formato: 937-943
ENG
Relevância na Pesquisa
56.42%
AimTo evaluate prospectively the clinical and radiographic outcomes after 2 years of loading of 6 mm long moderately rough implants supporting single crowns in the posterior regions.Material and methodsForty SLActive Straumann (R) short (6 mm) implants were placed in 35 consecutively treated patients. Nineteen implants, 4.1 mm in diameter, and 21 implants, 4.8 mm in diameter, were installed. Implants were loaded after 6 weeks of healing. Implant survival rate, marginal bone loss and resonance frequency analysis (RFA) were evaluated at different intervals. The clinical crown/implant ratio was also calculated.ResultsTwo out of 40 implants were lost before loading. Hence, the survival rate before loading was 95%. No further technical or biological complications were encountered during the 2-year follow-up. The mean marginal bone loss before loading was 0.34 +/- 0.38 mm. After loading, the mean marginal bone loss was 0.23 +/- 0.33 and 0.21 +/- 0.39 mm at the 1- and 2-year follow-ups. The RFA values increased between insertion (70.2 +/- 9) and the 6-week evaluation (74.8 +/- 6.1). The clinical crown/implant ratio increased with time from 1.5 at the delivery of the prosthesis to 1.8 after 2 years of loading.ConclusionShort implants (6 mm) with a moderately rough surface loaded early (after 6 weeks) during healing yielded high implant survival rates and moderate loss of bone after 2 years of loading. Longer observation periods are needed to draw more definite conclusions on the reliability of short implants supporting single crowns.To cite this article:Rossi F...

Short dental implants in posterior mandible

Bassi, Ana Paula Farnezi; De Oliveira, Jose Marcelo Cardoso; Ramalho-Ferreira, Gabriel; Faverani, Leonardo Perez
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
56.34%
The rehabilitation with oral implants is, without any doubt, a consecrated technique. But often we face situations of high bone atrophy where the conventional installation of dental implants is not possible. The posterior mandible, when severely resorbed, generally requires complex techniques to be rehabilitated with implants, such as the lateralization of the inferior alveolar nerve. As an option for these cases, this paper proposes the use of short implants for the rehabilitation of severely resorbed posterior mandible. Copyright © 2013 by Mutaz B. Habal, MD.

Tilted and Short Implants Supporting Fixed Prosthesis in an Atrophic Maxilla: A 3D-FEA Biomechanical Evaluation

Almeida, Erika O.; Rocha, Eduardo P.; Júnior, Amilcar C. Freitas; Anchieta, Rodolfo B.; Poveda, Ronald; Gupta, Nikhil; Coelho, Paulo G.
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
56.42%
Purpose: This study compared the biomechanical behavior of tilted long implant and vertical short implants to support fixed prosthesis in an atrophic maxilla. Materials and Methods: The maxilla model was built based on a tomographic image of the patient. Implant models were based on micro-computer tomography imaging of implants. The different configurations considered were M4S, four vertical anterior implants; M4T, two mesial vertical implants and two distal tilted (45°) implants in the anterior region of the maxilla; and M6S, four vertical anterior implants and two vertical posterior implants. Numerical simulation was carried out under bilateral 150N loads applied in the cantilever region in axial (L1) and oblique (45°) (L2) direction. Bone was analyzed using the maximum and minimum principal stress (σmax and σmin), and von Mises stress (σvM) assessments. Implants were analyzed using the σvM. Results: The higher σmax was observed at: M4T, followed by M6S/L1, M6S/L2, M4S/L2, and M4S/L1 and the higher σvM: M4T/L1, M4T/L2 and M4S/L2, M6S/L2, M4S/L1, and M6S/L1. Conclusions: The presence of distal tilted (all-on-four) and distal short implants (all-on-six) resulted in higher stresses in both situations in the maxillary bone in comparison to the presence of vertical implants (all-on-four). © 2013 Wiley Periodicals...

Implantes curtos em região posterior da mandíbula

Aguiar, Samuel Carlos; Barbosa, Camila da Hora; Queiroz, Thallita Pereira; Margonar, Rogério; Marcantonio Júnior, Elcio; Luvizuto, Eloá Rodrigues
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 695-702
POR
Relevância na Pesquisa
46.48%
The rehabilitation of edentulous areas with osseointegrated dental implants is a well-documented, predictable procedure in the literature, with high success rates. However, the lack of bone at the recipient bed or proximity to anatomic structures limits the rehabilitation procedure especially at the posterior mandible. Thus, short implants are an alternative treatment for such cases of severe bone resorption. The purpose of this study was to review the success rate of short implants, especially those based in the posterior mandible and to show a clinical case. A literature review was made on electronic databases PubMed and Bireme with articles published between the years 2005 to 2012, using the keywords "short dental implants". It was concluded that the success rates of short implants are similar to those presented by conventional implants but still related to their geometry and surface treatment. Also, short implants can be considered as a viable alternative for the rehabilitation of severely resorbed jaws. However, many authors consider that more research is necessary when a short implant is compared to a long dental implant.; A reabilitação de regiões edêntulas com implantes dentários osseointegráveis é um procedimento previsível...

Predictability of short dental implants: a literature review

Galvão, Fábio Ferreira de Souza Abbott; Almeida Júnior, Antônio Alves de; Faria-Júnior, Norberto Batista de; Caldas, Sergei Godeiro Fernandes Rabelo; Reis, José Maurício dos Santos Nunes; Margonar, Rogério
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 81-88
ENG
Relevância na Pesquisa
46.47%
Introduction: In clinical situations where severe bone resorption has occurred following tooth loss, implant treatment options may comprise either a previous bone reconstruction or only the use of short implants. Objective: This non-systematic review summarizes and discusses some aspects of the use of short implants, such as: biomechanical aspects, success rate, longevity and surgical-prosthetic planning. Literature review: Current and relevant references were selected in order to compare short dental implants to conventional ones. Several studies have highlighted the great importance of wide-diameter implants. Dental short implants have shown high predictability and success rates when some biomechanical aspects are taken into consideration. Conclusion: Placement of short dental implants is a viable treatment method for patients with decreased bone height.; Introdução: Nas situações clínicas em que ocorre severa reabsorção óssea após perda de dentes, as opções de tratamento com implantes incluem a necessidade de reconstrução óssea prévia e instalação de implantes convencionais ou apenas de implantes curtos. Objetivo: Revisar não sistematicamente a literatura com o propósito de sintetizar e discutir alguns itens sobre o uso de implantes curtos...

Estudo da perda precoce de implantes osseointegraveis realizados na Faculdade de Odontologia de Piracicaba - Unicamp no periodo de julho de 1996 a julho de 2004; Evaluation of early failure of dental implants performed at Piracicaba Dental School - Unicamp from july 1996 to july 2004

Alexander Tadeu Sverzut
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 23/02/2006 PT
Relevância na Pesquisa
46.26%
As perdas de implantes dentários podem ser classificadas em precoces ou tardias segundo BUSER et al. (1991). Esse trabalho objetivou analisar a perda precoce de implantes dentários e os fatores de risco associados. Foram utilizados para análise os prontuários clínicos dos pacientes tratados pela Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba-Unicamp que foram submetidos à instalação de implantes dentários no período de julho de 1996 a julho de 2004. Foram selecionados pacientes submetidos à instalação de implantes osseointegráveis e que foram submetidos à segunda fase cirúrgica. As variáveis selecionadas para o estudo foram: gênero, idade, uso do tabaco, uso do álcool, protocolo de instalação de implantes, reconstruções prévias, comprimento do implante, diâmetro do implante, área de instalação do implante, tipo de superfície do implante, uso de contraceptivos orais, terapia de reposição hormonal, hipertensão arterial, hipotireoidismo, hipertireoidismo e diabetes. Foram catalogados 1403 prontuários sendo que 660 prontuários efetivamente foram utilizados no estudo. Foram instalados e analisados 1649 implantes, 62 destes sofreram perda precoce. Os dados coletados foram analisados através de estatística univariada e regressão logística multivariada...

Análise fotoelástica da distribuição de tensões geradas por carregamento em coroas unitárias suportadas por implantes curto e longo; Photoelastic analysis with different width and height crown loaded over short and long single dental implant

Breno Carnevalli Franco de Carvalho
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 09/12/2013 PT
Relevância na Pesquisa
46.44%
Implantes curtos são utilizados em situações clínicas quando a altura e/ou a espessura óssea são insuficientes. A proposta neste estudo foi verificar por meio da análise de tensão fotoelástica a influência exercida pela altura e largura da coroa protética na força transmitida aos implantes curto (7 mm) e longo (13 mm) quando o carregamento foi efetuado no centro ou na extremidade das coroas. As dimensões da altura e da largura da coroa simulada foram estabelecidas com base nas dimensões de dentes pré-molar e molar inferiores humanos e a espessura estabelecida em 6 mm. O corpo-de-prova de resina fotoelástica foi feito com o sistema bi componente à base de resina epóxi modificada e endurecedor. Os carregamentos foram de 0,4 kgf no centro e de 0,3 kgf numa das extremidade da coroa. A análise fotoelástica avaliando as ordens de franjas ao redor dos implantes foi feita com polariscópio de transmissão. Cada fotografia foi analisada três vezes no programa Fringes para ordens de franja de 0 a 4, considerando as médias da ordem das franjas e da tensão cisalhante para cada ponto estabelecido no modelo. Os dados foram submetidos à ANOVA dois fatores e diferenças estatísticas comparadas pelo teste t de Student em nível de significância de 5%. Os resultados mostraram que não houve diferença entre os níveis de tensões gerados pela altura e largura das coroas protéticas sobre os implantes curto e longo...

Short Implants in Partially Edentuolous Maxillae and Mandibles: A 10 to 20 Years Retrospective Evaluation

Lops, Diego; Bressan, Eriberto; Pisoni, Gianluca; Cea, Niccolò; Corazza, Boris; Romeo, Eugenio
Fonte: Hindawi Publishing Corporation Publicador: Hindawi Publishing Corporation
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
46.52%
Purpose. Evaluation of the short implant (8 mm in height) long-term prognosis and of the implant site influence on the prognosis. Methods. A longitudinal study was carried out on 121 patients (57 males and 64 females) consecutively treated with 257 implants. 108 implants were short. Results. Four (3.6%) short implants supporting fixed partial prostheses failed. Similarly, three standard implants supporting fixed partial prostheses and one supporting single-crown prosthesis failed. Mean marginal bone loss (MBL) and probing depth (PD) of short and standard implants were statistically comparable (P > .05). The 20-year cumulative survival rates of short and standard implants were 92.3 and 95.9%, respectively. The cumulative success rates were 78.3 and 81.4%. The survival rates of short implants in posterior and anterior regions were comparable: 95 and 96.4%, respectively. The difference between survival rates was not significant (P > .05). Conclusions. The high reliability of short implants in supporting fixed prostheses was confirmed. Short and standard implants long-term prognoses were not significantly different. The prognosis of short implants in posterior regions was comparable to that of in anterior regions. Nevertheless, a larger sample is required to confirm this trend.

Early loading of 6-mm-short implants with a moderately rough surface supporting single crowns: a prospective 5-year cohort study

Rossi, Fabio; Lang, Niklaus P.; Ricci, Emanuele; Ferraioli, Lorenzo; Marchetti, Claudio; Botticelli, Daniele
Fonte: Wiley-Blackwell Publicador: Wiley-Blackwell
Tipo: Artigo de Revista Científica Formato: 471-477
ENG
Relevância na Pesquisa
56.31%
AimTo evaluate prospectively the clinical and radiographic outcomes after 5years of early loading of 6-mm implants with a moderately rough (SLActive((R))) surface supporting single crowns in the posterior regions.Material and methodsThirty-five consecutive patients received 40 SLActive((R)) (Straumann) 6-mm implants with a diameter of 4.1mm (n=19) or 4.8mm (n=21). Insertion torque and resonance frequency analysis (RFA) were measured at implant installation. RFA was also measured at abutment connection. SynOcta abutments were tightened with 35Ncm after 6weeks of healing, and single porcelain fuse to metal crowns was cemented within 1week. Implant survival rate and marginal bone loss were evaluated at various time intervals until 5years after loading. The clinical crown/implant ratio was calculated as well.ResultsTwo of 40 implants were lost before loading (incorporation rate 95%), and no further implant loss or technical complications were encountered during the 5-year follow-up period. A mean marginal bone loss of 0.70.6mm was found after 5years of function. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2 after 5years of loading.ConclusionSix millimeter implants with a SLActive((R)) moderately rough surface supporting single crowns in the posterior region and loaded after 6-7weeks maintained full function for at least 5year with low marginal bone resorption.

Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test

Verri, Fellippo Ramos; Santiago Junior, Joel Ferreira; Faria Almeida, Daniel Augusto de; Brandao de Oliveira, Guilherme Bergamo; Souza Batista, Victor Eduardo de; Honorio, Heitor Marques; Noritomi, Pedro Yoshito; Pellizzer, Eduardo Piza
Fonte: Elsevier B.V. Publicador: Elsevier B.V.
Tipo: Artigo de Revista Científica Formato: 138-145
ENG
Relevância na Pesquisa
46.16%
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.

Influência dos fatores protéticos em implantes curtos e análise da distribuição de tensão proveniente dos torques de inserção; Influence of the short implant prosthetic factors implants and the stress distribution from the insertion torques

Bruno Salles Sotto-Maior
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 15/04/2011 PT
Relevância na Pesquisa
46.33%
Os implantes curtos são uma alternativa terapêutica para rebordos reabsorvidos. Entretanto, em regiões posteriores atróficas apresentam maior risco biomecânico, devido às coroas protéticas mais longas decorrente do aumento do espaço inter-maxilar. Com objetivo de compensar a biomecânica desfavorável é aconselhável utilizar materiais restauradores menos rígidos, sistemas de retenção da prótese que facilitem a dissipação de tensões e uso de implantes com diâmetros maiores. Contudo, a influência desses fatores protéticos e o torque de inserção na concentração de tensões não está claramente esclarecida. Assim, os objetivos deste trabalho foram avaliar por meio do método dos elementos finitos tridimensional: I) A influência dos fatores protéticos (proporção coroa-implante (C/I), sistema de retenção da prótese, material restaurador e tipo de carregamento oclusal) na concentração de tensões nas regiões do osso cortical, medular, parafuso protético e no implante de prótese unitária suportada por implante curto; II) Avaliar a influência de diferentes torques de inserção na distribuição de tensão e deformação do osso cortical e medular. Para o primeiro objetivo foram criados 32 modelos da parte posterior de uma mandíbula atrófica. Cada modelo recebeu uma coroa metalocerâmica ou cerâmica pura...

Investigation of the influence of design details on short implant biomechanics using colorimetric photoelastic analysis: a pilot study

Zielak,João César; Archetti,Felipe Belmonte; Scotton,Ricardo; Filietaz,Marcelo; Storrer,Carmen Lucia Mueller; Giovanini,Allan Fernando; Deliberador,Tatiana Miranda
Fonte: Sociedade Brasileira de Engenharia Biomédica Publicador: Sociedade Brasileira de Engenharia Biomédica
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2015 EN
Relevância na Pesquisa
56.42%
Introduction: The clinical survival of a dental implant is directly related to its biomechanical behavior. Since short implants present lower bone/implant contact area, their design may be more critical to stress distribution to surrounding tissues. Photoelastic analysis is a biomechanical method that uses either simple qualitative results or complex calculations for the acquisition of quantitative data. In order to simplify data acquisition, we performed a pilot study to demonstrate the investigation of biomechanics via correlation of the findings of colorimetric photoelastic analysis (stress transition areas; STAs) of design details between two types of short dental implants under axial loads. Methods Implants were embedded in a soft photoelastic resin and axially loaded with 10 and 20 N of force. Implant design features were correlated with the STAs (mm2) of the colored fringes of colorimetric photoelastic analysis. Results Under a 10 N load, the surface area of the implants was directly related to STA, whereas under a 20 N load, the surface area and thread height were inversely related to STA. Conclusion A smaller external thread height seemed to improve the biomechanical performance of the short implants investigated.

; Short implants with single-unit restorations in posterior regions with reduced height – a retrospective study

Assaf, Jamal Hassan; Montebello Filho, Agenor; Zanatta, Fabricio Batistin
Fonte: UNICAMP/FOP Publicador: UNICAMP/FOP
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; ; Formato: application/pdf
Publicado em 16/11/2015 ENG
Relevância na Pesquisa
66.5%
; Aim: Previous studies have shown excellent prognosis with short implants. However, evidence of short implants rehabilitated with single-unit restorations is scarce. The purpose of this study was to evaluate the percentage of success of short implants in posterior maxillary and mandibular regions with single-unit restorations. Methods: This study comprised a retrospective analysis of data of 41 patients that received 54 short implants between 2004 and 2009. All implants were placed by the same surgeon and all restorations were performed by experienced professionals. All implants were placed in sites with reduced bone volume; 48 implants were evaluated by computed tomography and 6 implants by radiography. Failures and biological complications were analyzed. Results: It was observed a success rate of 96.3% in the osseointegration period and 100% in the load period that ranging from 7 to 38 months. Two complications were observed, which were successfully treated without risk of implant loss. Conclusions: Short implants in posterior regions rehabilitated with single-unit restorations are a treatment option with high success rate and thus may be indicated in posterior regions with reduced bone height.