Página 1 dos resultados de 17781 itens digitais encontrados em 0.160 segundos

Ressonância magnética nos desarranjos internos da ATM: sensibilidade e especificidade; Diagnosis of TMJ disorders by magnetic resonance imaging: sensitivity and specificity

CALDERON, Patrícia dos Santos; REIS, Kátia Rodrigues; ARAÚJO, Carlos dos Reis Pereira; RUBO, José Henrique; CONTI, Paulo César Rodrigues
Fonte: Dental Press Editora Publicador: Dental Press Editora
Tipo: Artigo de Revista Científica
POR
Relevância na Pesquisa
75.73%
OBJETIVO: esta revisão de literatura visa avaliar, através de literatura específica, a sensibilidade e especificidade do exame de ressonância magnética (RM) para o diagnóstico dos desarranjos internos da articulação temporomandibular (ATM). METODOLOGIA: tanto artigos que utilizaram ATM de cadáveres para comparar achados anatômicos aos achados de ressonância magnética (RM), como artigos que compararam achados clínicos com achados de RM foram utilizados. Através dos achados desses artigos, as propriedades de sensibilidade e especificidade da RM para o diagnóstico de desarranjos internos da ATM foram calculadas. Com isso, a confiabilidade e a aplicabilidade do exame de RM no diagnóstico dos desarranjos internos da ATM foram discutidas. RESULTADOS: encontrou-se sensibilidade de 90% e especificidade de 88% da RM para desarranjos internos da ATM. CONCLUSÃO: o exame de RM de ATM possui ótima sensibilidade e especificidade para o diagnóstico dos desarranjos internos da ATM. Porém, tal exame deve ser solicitado com cautela, apenas nos casos onde a imagem seja indispensável para o plano de tratamento.; OBJECTIVE: the aim of this paper is to review the literature concerning the reliability and applicability of magnetic resonance imaging (MRI) in the diagnosis of temporomandibular joint (TMJ) internal disorders. METHODS: articles that have used TMJ from cadavers to compare MRI findings with anatomic findings...

Comparação entre testes químico (o-toluidina) e imunoquímico de pesquisa de sangue oculto nas fezes e correlação com os achados colonoscópicos; Comparison between chemical (toluidine) and immunochemical faecal occult blood tests and correlation with the colonoscopic findings

Borges, Luana Vilarinho
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 24/04/2013 PT
Relevância na Pesquisa
75.73%
Introdução: O sangramento colorretal é considerado um sinal de alarme e não deve ser ignorado. A perda de sangue pode não ser identificada pelo paciente, o que caracteriza a presença de sangue oculto. Este diagnóstico pode ser confirmado por testes de Pesquisa de Sangue Oculto nas Fezes (PSOF), através de métodos químicos ou imunoquímicos de identificação da hemoglobina. O resultado positivo de um teste de PSOF requer investigação complementar com colonoscopia, exame invasivo, de alto custo e que exige preparo intestinal. Justifica-se, portanto, a aplicação de um teste diagnóstico mais sensível e específico. No presente estudo, foram avaliados quatro diferentes testes de PSOF em 176 pacientes submetidos à colonoscopia e seus resultados foram comparados. Objetivos: 1) avaliar o grau de concordância entre os testes de PSOF e a colonoscopia. 2) avaliar a sensibilidade, a especificidade e os valores de predição dos testes químico e imunoquímico de PSOF, em pacientes submetidos à colonoscopia. Métodos: Pacientes com indicação de realizar colonoscopia foram submetidos também à PSOF pelo método químico (o-toluidina) e pelo método imunoquímico, empregando três kits comerciais disponíveis no mercado. Os pacientes foram avaliados quanto à indicação do exame colonoscópico...

Teste de Morisky-Green e brief medication questionnaire para avaliar adesão a medicamentos; The brief medication questionnaire and morisky-green test to evaluate medication adherence

Ben, Ângela Jornada; Neumann, Cristina Rolim; Mengue, Sotero Serrate
Fonte: Universidade Federal do Rio Grande do Sul Publicador: Universidade Federal do Rio Grande do Sul
Tipo: Artigo de Revista Científica Formato: application/pdf
POR
Relevância na Pesquisa
75.73%
OBJETIVO: Analisar a confiabilidade e o desempenho da versão em português de instrumentos de avaliação da adesão ao tratamento anti-hipertensivo. MÉTODOS: Pacientes hipertensos atendidos de janeiro a setembro de 2010 em uma unidade de atenção primária em Porto Alegre, RS, foram selecionados aleatoriamente (n = 206). Na avaliação da adesão foram utilizadas versões em português do Teste de Morisky-Green (TMG) e do Brief Medication Questionnaire (BMQ). Foram analisados consistência interna, estabilidade temporal e desempenho com relação a três padrões-ouro: controle inadequado da pressão arterial (≥ 140/90 mmHg); taxa insuficiente de retirada de medicação na farmácia da Unidade Básica de Saúde (< 80%); e a combinação de ambos. RESULTADOS: Dos pacientes avaliados, 97 utilizavam medicamentos dispensados somente pela farmácia da Unidade Básica de Saúde. Os testes apresentaram boa consistência interna: BMQ α de Cronbach de 0,66 (IC95% 0,60;0,73) e o TMG 0,73 (IC95% 0,67;0,79). O desempenho do BMQ no domínio regime apresentou sensibilidade de 77%, especificidade de 58% e área sob a curva ROC de 0,70 (IC95% 0,55;0,86), e o TMG sensibilidade de 61%, especifi cidade de 36% e área sob a curva ROC de 0,46 (IC95% 0...

Diagnostic accuracy of semi-quantitative and quantitative culture techniques for the diagnosis of catheter-related infections in newborns and molecular typing of isolated microorganisms

Moraes Riboli, Danilo Flavio; Lyra, Joao Cesar; Silva, Eliane Pessoa; Valadao, Luisa Leite; Bentlin, Maria Regina; Corrente, Jose Eduardo; Suppo de Souza Rugolo, Ligia Maria; Ribeiro de Souza da Cunha, Maria de Lourdes
Fonte: Biomed Central Ltd. Publicador: Biomed Central Ltd.
Tipo: Artigo de Revista Científica Formato: 9
ENG
Relevância na Pesquisa
75.73%
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Processo FAPESP: 10/14581-7; Processo FAPESP: 14/07631-9; Background: Catheter-related bloodstream infections (CR-BSIs) have become the most common cause of healthcare-associated bloodstream infections in neonatal intensive care units (ICUs). Microbiological evidence implicating catheters as the source of bloodstream infection is necessary to establish the diagnosis of CR-BSIs. Semi-quantitative culture is used to determine the presence of microorganisms on the external catheter surface, whereas quantitative culture also isolates microorganisms present inside the catheter. The main objective of this study was to determine the sensitivity and specificity of these two techniques for the diagnosis of CR-BSIs in newborns from a neonatal ICU. In addition, PFGE was used for similarity analysis of the microorganisms isolated from catheters and blood cultures.Methods: Semi-quantitative and quantitative methods were used for the culture of catheter tips obtained from newborns. Strains isolated from catheter tips and blood cultures which exhibited the same antimicrobial susceptibility profile were included in the study as positive cases of CR-BSI. PFGE of the microorganisms isolated from catheters and blood cultures was performed for similarity analysis and detection of clones in the ICU.Results: A total of 584 catheter tips from 399 patients seen between November 2005 and June 2012 were analyzed. Twenty-nine cases of CR-BSI were confirmed. Coagulase-negative staphylococci (CoNS) were the most frequently isolated microorganisms...

Sensitivity and specificity of machine learning classifiers and spectral domain OCT for the diagnosis of glaucoma= : Sensibilidade e especificidade de sistemas de aprendizagem de máquina e da tomografia de coerência óptica de domínio espectral para o diagnóstico de glaucoma; Sensibilidade e especificidade de sistemas de aprendizagem de máquina e da tomografia de coerência óptica de domínio espectral para o diagnóstico de glaucoma

Vanessa Gonçalves Vidotti Pimenta
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 27/01/2014 PT
Relevância na Pesquisa
95.69%
O presente estudo teve como objetivo investigar a sensibilidade e especificidade dos classificadores de aprendizagem de máquina (MLC) e da tomografia de coerência óptica de domínio espectral (SD-OCT) para o diagnóstico de glaucoma. Sessenta e dois pacientes com glaucoma e defeito de campo visual inicial a moderado, e 48 indivíduos saudáveis foram incluídos. Todos os participantes foram submetidos a um exame oftalmológico completo, perimetria automatizada acromática e medida da espessura da camada de fibras nervosas da retina com SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, Califórnia, EUA). Uma curva ROC (receiver operating curve) foi obtida para cada parâmetro do SD-OCT: espessura média, espessura nos quatro quadrantes (temporal, superior, nasal e inferior) e a espessura a cada hora de relógio. Posteriormente, foram testados os seguintes MLCs construídos a partir dos dados do OCT: Árvore de Decisão (CTREE), Random Forest (RAN), Bagging (BAG), Adaptative Boosting (ADA), Ensemble Selection (ENS), Multilayer Perceptrons (MLP), Rede de Funções de Base Radial (RBF), Naive-Bayes (NB), Support Vector Machine - Linear (SVMl) e Support Vector Machine - Gaussian (SVMg). Áreas sob as curvas ROC (aROCs) foram obtidas para cada parâmetro do SD-OCT e para cada MLC. A média de idade foi de 57...

Sensitivity and specificity of the body mass index for the diagnosis of overweight/obesity in elderly

Vasconcelos,Francisco de Assis Guedes de; Cordeiro,Braian Alves; Rech,Cassiano Ricardo; Petroski,Edio Luiz
Fonte: Escola Nacional de Saúde Pública Sergio Arouca, Fundação Oswaldo Cruz Publicador: Escola Nacional de Saúde Pública Sergio Arouca, Fundação Oswaldo Cruz
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/08/2010 EN
Relevância na Pesquisa
95.76%
The aim of this article was to verify the sensitivity and specificity of the body mass index (BMI) cut-off points proposed by the World Health Organization (WHO) and the Nutrition Screening Initiative (NSI) for the diagnosis of obesity in the elderly. A cross-sectional study was made with 180 healthy elderly subjects from Florianópolis, Santa Catarina State, Brazil. Body fat percentage (%BF) was determined using DEXA (dual energy X-ray absorptiometry). The BMI cut-off point of the NSI offers better sensitivity and specificity for men (73.7% and 72.5% respectively). For women, the lower the cut-off point the better the sensitivity, with a BMI of 25kg/m² (sensitivity of 76.3% and specificity of 100%) being the most accurate for diagnosing obesity in elderly women. The WHO cut-off point offered very low sensitivity (28.9%). The results of this investigation lead to the conclusion that the cut-off points proposed by the WHO and the ones adopted by the NSI and by Lipschitz are not good indicators of obesity for the elderly of either sex, since they offer low sensitivity.

Sensitivity and specificity of body mass index-based classification systems for overweight in children 7-10 years old

Leal,Danielle Biazzi; Costa,Filipe Ferreira da; Assis,Maria Alice Altenburg de
Fonte: Universidade Federal de Santa Catarina Publicador: Universidade Federal de Santa Catarina
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2013 EN
Relevância na Pesquisa
95.73%
The objective of this study was to compare the sensitivity and specificity of BMI-based classification systems for detecting excess body fat in schoolchildren. A total of 2,795 schoolchildren aged 7 to 10 years were examined. Excess body fat was defined as the standardized residuals of sum of three skinfolds thickness ranking at or above the 90th percentile. The international BMI-based systems recommended by the International Obesity Task Force (IOTF) and the World Health Organization (WHO-2007) were evaluated on the basis of their sensitivity and specificity for detecting excess body fat and compared with a national BMI reference (Brazil-2006). The positive (LR+) and negative (LR-) likelihood ratios analysis was also used to compare the diagnostic accuracies of the three BMI criteria. The three classification systems presented moderately high sensitivity (78.4-98.6%) and specificity (75.9-91.6%) for both genders. Overall, the three classification systems showed both LR+ and LR- values consistent with a diagnosis of moderate evidence for overweight (LR+ above five and LR- below 0.2). The results showed that the three BMI classification systems can be used as screening instruments of excess body fat. However, the performance of the Brazil-2006 classification system was superior because it showed the best balance between the diagnostic accuracy indices.

Evaluation of Bias in Diagnostic-Test Sensitivity and Specificity Estimates Computed by Discrepant Analysis

Green, Timothy A.; Black, Carolyn M.; Johnson, Robert E.
Fonte: American Society for Microbiology Publicador: American Society for Microbiology
Tipo: Artigo de Revista Científica
Publicado em /02/1998 EN
Relevância na Pesquisa
75.67%
When a new diagnostic test is potentially more sensitive than the reference test used to classify persons as infected or uninfected, a substantial number of specimens from infected persons may be reference-test negative but new-test positive. Discrepant analysis involves the performance of one or more additional tests with these specimens, reclassification as infected those persons for whom the new-test-positive results are confirmed, and recalculation of the estimates of new-test sensitivity and specificity by using the revised classification. This approach has been criticized because of the bias introduced by the selective use of confirmation testing. Under conditions appropriate for evaluating a nucleic acid amplification (NAA) test for Chlamydia trachomatis infection with cell culture as the reference test, we compared the bias in estimates based on the discrepant-analysis classification of persons as infected or uninfected with that in estimates based on the culture classification. We concluded that the bias in estimates of NAA-test specificity based on discrepant analysis is small and generally less than that in estimates based on culture. However, the accuracy of discrepant-analysis-based estimates of NAA-test sensitivity depends critically on whether culture specificity is equal to or is slightly less than 100%...

Sensitivity and specificity of machine learning classifiers for glaucoma diagnosis using Spectral Domain OCT and standard automated perimetry

Silva,Fabrício R.; Vidotti,Vanessa G.; Cremasco,Fernanda; Dias,Marcelo; Gomi,Edson S.; Costa,Vital P.
Fonte: Conselho Brasileiro de Oftalmologia Publicador: Conselho Brasileiro de Oftalmologia
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2013 EN
Relevância na Pesquisa
95.64%
PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05)...

Variation in Specificity of HIV Rapid Diagnostic Tests over Place and Time: An Analysis of Discordancy Data Using a Bayesian Approach

Klarkowski, Derryck; Glass, Kathryn; O’Brien, Daniel; Lokuge, Kamalini; Piriou, Erwan; Shanks, Leslie
Fonte: Public Library of Science Publicador: Public Library of Science
Tipo: Artigo de Revista Científica
Relevância na Pesquisa
75.72%
BACKGROUND Recent trends to earlier access to anti-retroviral treatment underline the importance of accurate HIV diagnosis. The WHO HIV testing strategy recommends the use of two or three rapid diagnostic tests (RDTs) combined in an algorithm and assume a population is serologically stable over time. Yet RDTs are prone to cross reactivity which can lead to false positive or discordant results. This paper uses discordancy data from Médecins Sans Frontières (MSF) programmes to test the hypothesis that the specificity of RDTs change over place and time. METHODS Data was drawn from all MSF test centres in 2007-8 using a parallel testing algorithm. A Bayesian approach was used to derive estimates of disease prevalence, and of test sensitivity and specificity using the software WinBUGS. A comparison of models with different levels of complexity was performed to assess the evidence for changes in test characteristics by location and over time. RESULTS 106, 035 individuals were included from 51 centres in 10 countries using 7 different RDTs. Discordancy patterns were found to vary by location and time. Model fit statistics confirmed this, with improved fit to the data when test specificity and sensitivity were allowed to vary by centre and over time. Two examples show evidence of variation in specificity between different testing locations within a single country. Finally...

Diagnostic accuracy of the STRATIFY clinical prediction rule for falls: a systematic review and meta-analysis

Billington, Jennifer; Fahey, Tom; Galvin, Rose
Fonte: BioMed Central Publicador: BioMed Central
Tipo: info:eu-repo/semantics/article; all_ul_research; ul_published_reviewed
ENG
Relevância na Pesquisa
75.71%
peer-reviewed; Background: The STRATIFY score is a clinical prediction rule (CPR) derived to assist clinicians to identify patients at risk of falling. The purpose of this systematic review and meta-analysis is to determine the overall diagnostic accuracy of the STRATIFY rule across a variety of clinical settings. Methods: A literature search was performed to identify all studies that validated the STRATIFY rule. The methodological quality of the studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. A STRATIFY score of ≥2 points was used to identify individuals at higher risk of falling. All included studies were combined using a bivariate random effects model to generate pooled sensitivity and specificity of STRATIFY at ≥2 points. Heterogeneity was assessed using the variance of logit transformed sensitivity and specificity. Results: Seventeen studies were included in our meta-analysis, incorporating 11,378 patients. At a score ≥2 points, the STRATIFY rule is more useful at ruling out falls in those classified as low risk, with a greater pooled sensitivity estimate (0.67, 95% CI 0.52–0.80) than specificity (0.57, 95% CI 0.45 – 0.69). The sensitivity analysis which examined the performance of the rule in different settings and subgroups also showed broadly comparable results...

Especificidade e sensibilidade de rastreamento para lesões cutâneas pré-malignas e malignas; Sensitivity and specificity of screening cutaneous pre-malignant and malignant lesions

Rocha, Fernando Passos da; Menezes, Ana M B; Almeida Junior, Hiram Larangeira de; Tomasi, Elaine
Fonte: Universidade de São Paulo. Faculdade de Saúde Pública Publicador: Universidade de São Paulo. Faculdade de Saúde Pública
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; ; ; ; Formato: application/pdf
Publicado em 01/02/2002 POR
Relevância na Pesquisa
95.77%
OBJETIVO: O melanoma tem incidência crescente, sendo que a prevalência dos tumores malignos epiteliais é alta, e o diagnóstico precoce contribui significativamente para a redução da morbimortalidade dessas doenças. O objetivo da pesquisa é medir a prevalência das lesões cutâneas pré-malignas e malignas e determinar a sensibilidade e a especificidade de um rastreamento para essas lesões. MÉTODOS: Foi realizado um estudo transversal de base populacional com escolha aleatória de 48 setores censitários da zona urbana de Pelotas, RS, Brasil. Um total de 2.112 domicílios foram visitados, sendo entrevistadas 1.292 pessoas de 50 anos de idade ou mais. O rastreamento possuía questões específicas sobre o surgimento de lesões de pele nos últimos seis meses e/ou a presença de lesões em áreas expostas. Os que responderam afirmativamente foram encaminhados ao exame médico. Também foi examinada uma subamostra daqueles que haviam respondido negativamente às questões do rastreamento. RESULTADOS: A prevalência corrigida das lesões cutâneas pré-malignas e malignas foi de 20,7%. A sensibilidade do rastreamento foi de 20,1%, a especificidade, de 86,9%, o valor preditivo positivo, de 29%, o valor preditivo negativo, de 80...

Sensibilidade e especificidade de classificação de sobrepeso em adolescentes, Rio de Janeiro; Sensitivity and specificity of overweight classification of adolescents, Brazil

Chiara, Vera; Sichieri, Rosely; Martins, Patrícia D
Fonte: Universidade de São Paulo. Faculdade de Saúde Pública Publicador: Universidade de São Paulo. Faculdade de Saúde Pública
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; ; ; ; Formato: application/pdf
Publicado em 01/04/2003 POR
Relevância na Pesquisa
95.64%
OBJETIVO: Avaliar a prevalência, sensibilidade e especificidade em detectar adolescentes em risco de obesidade, baseada no Índice de Massa Corporal (IMC). MÉTODOS: Foram avaliados 502 adolescentes de 12 a 18 anos, participantes da pesquisa Nutrição e Saúde do Município do Rio de Janeiro, desenvolvida em 1996. As variáveis do estudo foram: peso, estatura, IMC e dobra subescapular, de acordo com sexo e idade. As classificações para IMC foram comparadas com a classificação pela dobra subescapular no percentil 90 (excesso de adiposidade) da população de adolescentes americanos. RESULTADOS: A prevalência de excesso de adiposidade foi mais elevada com a dobra subescapular (P; OBJECTIVE: To evaluate the prevalence, sensitivity and specificity of two risk classifications of obesity based on the body mass index (BMI). METHODS: Five-hundred and two adolescents, aged 12-18 years, participants of a health and nutrition survey conducted in 1996 in the city of Rio de Janeiro, Brazil, were evaluated. The study variables included: weight, stature, BMI, and subscapular skinfold, according to sex and age. The BMI classifications were compared to a fatness classification based on the 90th percentile of subscapular skinfold thickness in American adolescents. RESULTS: The prevalence of risk of obesity was higher when using the subscapular skinfold measurement (p

Sensibilidade e especificidade de critérios de classificação do índice de massa corporal em adolescentes; Sensibilidad y especificidad de criterios de clasificación del índice de masa corporal en adolescentes; Sensitivity and specificity of criteria for classifying body mass index in adolescents

Farias Júnior, José Cazuza de; Konrad, Lisandra Maria; Rabacow, Fabiana Maluf; Grup, Susane; Araújo, Valbério Candido
Fonte: Universidade de São Paulo. Faculdade de Saúde Pública Publicador: Universidade de São Paulo. Faculdade de Saúde Pública
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; ; ; ; Formato: application/pdf; application/pdf
Publicado em 01/02/2009 POR; ENG
Relevância na Pesquisa
95.74%
OBJETIVO: Estimar la prevalencia de exceso de peso en adolescentes conforme criterios de clasificación del índice de masa corporal (IMC) y respectivas sensibilidad y especificidad. MÉTODOS: Fueron realizadas medidas de peso, estatura y pliegues cutáneos, subescapular y triciptal, en 934 adolescentes (masculino= 462 y femenino= 472) de 14 a 18 años de edad (promedio= 16,2; dp=1,0) de la ciudad de Florianópolis (Sur de Brasil), en 2001. El porcentaje de gordura estimado a partir de los pliegues cutáneos (?25% en el masculino y ?30% en el femenino) fue utilizado como criterio estándar-oro para determinar la sensibilidad y especificidad de los criterios de clasificación del IMC en adolescentes. RESULTADOS: La aplicación de diferentes puntos de corte de clasificación del IMC, en general, resultó en prevalencias de exceso de peso similares (p>;0,05).La sensibilidad de los criterios evaluados fue elevada en los adolescentes del sexo masculino (85,4% a 91,7%) y baja en las del sexo femenino (33,8% a 52,8%). La especificidad fue elevada en todos los criterios, para ambos sexos (83,6% a 98,8%). CONCLUSIONES: Las estimaciones de prevalencia de exceso de peso por los criterios de clasificación del IMC en adolescentes fueron similares y presentaron especificidad elevada para ambos sexos...

Validade do diabetes auto-referido e seus determinantes: evidências do projeto Bambuí; Validity of self-reported diabetes and its determinants: evidences from the Bambuí study

Lima-Costa, Maria Fernanda; Peixoto, Sérgio Viana; Firmo, Josélia Oliveira Araújo; Uchoa, Elizabeth
Fonte: Universidade de São Paulo. Faculdade de Saúde Pública Publicador: Universidade de São Paulo. Faculdade de Saúde Pública
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; ; ; ; Formato: application/pdf
Publicado em 01/12/2007 POR
Relevância na Pesquisa
75.69%
OBJETIVO: Avaliar a validade do diabetes auto-referido e seus determinantes entre idosos. MÉTODOS: Participaram do estudo transversal 1.492 indivíduos >; 60 anos de idade, que correspondiam a 86% de todos os moradores, na faixa etária considerada, da cidade de Bambuí, Minas Gerais, em 1997. A validade do diabetes auto-referido foi determinada em relação ao diabetes mellitus definido por critérios médicos (glicemia de jejum >; 126 mg/dl ou tratamento). RESULTADOS: As prevalências do diabetes mellitus e do diabetes auto-referido foram de 14,5% e 11,7%, respectivamente. A sensibilidade e a especificidade do último em relação ao primeiro foram 57,1% (IC 95%: 50,3;63,8) e 96,0% (IC 95%: 94,7;97,0). Visitas ao médico há menos de dois anos (RP=3,78), escolaridade de um a três anos (RP= 1,90) e >; 4 anos (RP=1,55) apresentaram associações positivas e independentes com a sensibilidade. Visitas ao médico há menos de dois anos (RP=0,96) e sexo feminino (RP=0,97) apresentaram associações negativas e independentes com a especificidade. CONCLUSÕES: Os resultados mostraram que o diabetes auto-referido não deve ser usado como indicador da prevalência do diabetes mellitus na população estudada, nem para a identificação de indivíduos com a doença. A escolaridade e o uso de serviços de saúde foram determinantes da capacidade do idoso informar corretamente a sua condição de diabético...

Sensibilidade e especificidade no diagnóstico de hipertensão por diferentes métodos; Sensibilidad y especificidad en el diagnóstico de hipertensión por diferentes métodos; Sensitivity and specificity in the diagnosis of hypertension with different methods

Nascimento, Larissa Rangel; Coelli, Anna Paula; Cade, Nágela Valadão; Mill, José Geraldo; Molina, Maria del Carmen Bisi
Fonte: Universidade de São Paulo. Faculdade de Saúde Pública Publicador: Universidade de São Paulo. Faculdade de Saúde Pública
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; ; ; ; Formato: application/pdf; application/pdf
Publicado em 01/10/2011 POR; ENG
Relevância na Pesquisa
95.71%
OBJETIVO: Avaliar a sensibilidade e a especificidade de diferentes protocolos de medida da pressão arterial para o diagnóstico da hipertensão em adultos. MÉTODOS: Estudo transversal com amostra não probabilística de 250 funcionários de ambos os sexos de instituição pública na faixa etária de 35 a 74 anos em Vitória, ES, entre 2008 e 2010. Os participantes tiveram suas pressões arteriais aferidas por três métodos: medida clínica, automedida e medida ambulatorial por 24 horas. Foram coletados dados antropométricos (peso, estatura e circunferências) e realizada entrevista. Os métodos foram confrontados e analisados em relação à medida ambulatorial 24 h (padrão-ouro). Foram calculadas as medidas de desempenho diagnóstico: sensibilidade, especificidade, valores preditivos positivos e negativos e acurácia. A metodologia de Bland & Altman foi utilizada para verificar a concordância entre a variabilidade pressórica na medida ambulatorial (desvio-padrão relativo ao período diurno) e a variabilidade pressórica na automedida (desvio-padrão das quatro medidas). Adotou-se nível de significância de 5% para todos os testes. RESULTADOS: A automedida apresentou maior sensibilidade (S = 84%; IC95%: 75;93) e acurácia global (0...

Sensibilidade e especificidade dos sistemas de classificação para sobrepeso baseados no índice de massa corporal em crianças de 7-10 anos de idade.; Sensitivity and specificity of body mass index-based classification systems for overweight in children 7-10 years old.

Leal, Danielle Biazzi; Universidade Federal de Santa Catarina. Programa de Pós-Graduação em Educação Física. Florianópolis, SC. Brasil; da Costa, Filipe Ferreira; Universidade Federal de Santa Catarina. Programa de Pós-Graduação em Nutrição. F
Fonte: Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil Publicador: Universidade Federal de Santa Catarina. Florianópolis, SC. Brasil
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; "Avaliado por Pares",; Epidemiological survey; Avaliado por Pares; Estudo epidemiológico tranversal Formato: application/pdf
Publicado em 30/03/2013 ENG
Relevância na Pesquisa
95.76%
DOI: http://dx.doi.org/10.5007/1980-0037.2013v15n3p267 O objetivo deste estudo foi comparar a sensibilidade e especificidadede sistemas de classificação baseados no índice de massa corporal (IMC) na detecção do excesso degordura corporal em escolares. Um total de 2795 escolares com idade entre sete a dez anos foram examinados. O excesso de gordura corporal foi definido como os resíduos padronizados do somatório de três dobras cutâneas iguais ou superiores ao percentil 90. Os sistemas internacionais baseados no IMC recomendados pela International Obesity Task Force (IOTF) e Organização Mundial de Saúde (OMS-2007) foram avaliados com base emsua sensibilidade e especificidade para detecção do excesso de gordura corporal e comparado com uma referência do IMC nacional (Brasil-2006). Análise das razões de verossimilhança positiva (RV+) e negativa (RV-) também foi utilizada para comparar as precisões diagnósticas dos três critérios do IMC. Os três sistemas de classificação apresentaram sensibilidade (78,4-98,6%) e especificidade (75,9-91,6%) moderadamente alta para ambos os sexos. No geral,os três sistemas de classificação apresentaram valores de RV+ e RV-, condizentes com umdiagnóstico de evidência moderada para o sobrepeso (RV+ acima de cinco e RV- abaixo de 0...

Evaluation of the micro-CATT, CATT/Trypanosoma brucei gambiense, and LATEX/T. b. gambiense methods for serodiagnosis and surveillance of human African trypanosomiasis in West and Central Africa

Truc,Philippe; Lejon,Veerle; Magnus,Eddy; Jamonneau,Vincent; Nangouma,Auguste; Verloo,Didier; Penchenier,Laurent; Büscher,Philippe
Fonte: World Health Organization Publicador: World Health Organization
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/11/2002 EN
Relevância na Pesquisa
75.67%
OBJECTIVE: To evaluate the performance of serological tests using dried blood on filter-papers (micro-card agglutination test for trypanosomiasis (micro-CATT)) performed under field and laboratory conditions and using whole blood ((CATT/T.b. gambiense) (wb-CATT) and latex agglutination (LATEX/T.b. gambiense) (wb-LATEX)) for the serodiagnosis and surveillance of human African trypanosomiasis in West and Central Africa. METHODS: We evaluated the micro-CATT, wb-CATT and wb-LATEX methods in Côte d'Ivoire and the Central African Republic by screening 940 people. Sensitivity and specificity were calculated for each serological test; only patients with the confirmed presence of trypanosomes in the blood or lymph aspirate were considered true positives. Positive and negative predictive values were also calculated. FINDINGS: Each of the tests showed a lower sensitivity in the Central African Republic than in Côte d'Ivoire. CONCLUSION: The results confirmed the efficiency of the classic wb-CATT to detect sleeping sickness patients. The micro-CATT method can be used for human African trypanosomiasis surveillance if the test is performed on the same day as the blood collection, or if samples are stored at 4 ºC. Otherwise, micro-CATT can be used when absolute sensitivity is not required. wb-LATEX should only be used for high-specificity screening.

Sensitivity and specificity of the body mass index for the diagnosis of overweight/obesity in elderly

Vasconcelos,Francisco de Assis Guedes de; Cordeiro,Braian Alves; Rech,Cassiano Ricardo; Petroski,Edio Luiz
Fonte: Escola Nacional de Saúde Pública Sergio Arouca, Fundação Oswaldo Cruz Publicador: Escola Nacional de Saúde Pública Sergio Arouca, Fundação Oswaldo Cruz
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/08/2010 EN
Relevância na Pesquisa
95.76%
The aim of this article was to verify the sensitivity and specificity of the body mass index (BMI) cut-off points proposed by the World Health Organization (WHO) and the Nutrition Screening Initiative (NSI) for the diagnosis of obesity in the elderly. A cross-sectional study was made with 180 healthy elderly subjects from Florianópolis, Santa Catarina State, Brazil. Body fat percentage (%BF) was determined using DEXA (dual energy X-ray absorptiometry). The BMI cut-off point of the NSI offers better sensitivity and specificity for men (73.7% and 72.5% respectively). For women, the lower the cut-off point the better the sensitivity, with a BMI of 25kg/m² (sensitivity of 76.3% and specificity of 100%) being the most accurate for diagnosing obesity in elderly women. The WHO cut-off point offered very low sensitivity (28.9%). The results of this investigation lead to the conclusion that the cut-off points proposed by the WHO and the ones adopted by the NSI and by Lipschitz are not good indicators of obesity for the elderly of either sex, since they offer low sensitivity.

Concurrent evaluation of visual, cytological and HPV testing as screening methods for the early detection of cervical neoplasia in Mumbai, India

Shastri,Surendra S.; Dinshaw,Ketayun; Amin,Geetanjali; Goswami,Smriti; Patil,Sharmila; Chinoy,Roshini; Kane,S.; Kelkar,Rohini; Muwonge,Richard; Mahé,Cédric; Ajit,Dulhan; Sankaranarayanan,R.
Fonte: World Health Organization Publicador: World Health Organization
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/03/2005 EN
Relevância na Pesquisa
75.71%
OBJECTIVE: Naked eye visual inspection with acetic acid (VIA), magnified VIA (VIAM), visual inspection with Lugol's iodine (VILI), cytology and human papillomavirus (HPV) testing were evaluated as screening methods for the detection of high-grade squamous intraepithelial lesions (HSIL) of the uterine cervix in a cross-sectional study in Mumbai, India. METHODS: Cytology, HPV testing, VIA, VIAM and VILI were carried out concurrently for 4039 women aged 30-65 years. All women were investigated with colposcopy and biopsies were taken from 939 women who had colposcopic abnormalities. The reference standard for final disease status was histology or negative colposcopy. The presence of HSIL was confirmed in 57 women (1.4%). The test characteristics for each method were calculated using standard formulae. RESULTS: The sensitivities of cytology, HPV testing, VIA, VIAM and VILI were 57.4%, 62.0%, 59.7%, 64.9%, and 75.4%, respectively (differences were not statistically significant). The specificities were 98.6%, 93.5%, 88.4%, 86.3%, and 84.3%, respectively. Adding a visual test to cytology or HPV testing in parallel combination resulted in a substantial increase in sensitivity, with a moderate decrease in specificity. The parallel combination of VILI and HPV testing resulted in a sensitivity of 92.0% and a specificity of 79.9%. CONCLUSION: As a single test...