Página 1 dos resultados de 123 itens digitais encontrados em 0.009 segundos

Cu and Fe metallic ions-mediated oxidation of low-density lipoproteins studied by NMR, TEM and Z-scan technique

GOMEZ, S. L.; MONTEIRO, A. M.; Rabbani, Said Rahnamaye; Bloise Junior, Antonio Carlos; CARNEIRO, S. M.; ALVES, S.; GIDLUND, M.; ABDALLA, D. S. P.; Figueiredo Neto, Antonio Martins
Fonte: ELSEVIER IRELAND LTD Publicador: ELSEVIER IRELAND LTD
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
45.88%
In this work we report on a study of the morphological changes of LDL induced in vitro by metallic ions (Cu(2+) and Fe(3+)). These modifications were characterized by transmission electron microscopy, nuclear magnetic resonance and the Z-scan technique. The degree of oxidative modification of LDL was determined by the TBARS and lipid hydroperoxides assays. It is shown that distinct pathways for modifying lipoproteins lead to different morphological transformations of the particles characterized by changes in size and/or shape of the resulting particles, and by the tendency to induce aggregation of the particles. There were no evidence of melting of particles promoted by oxidative processes with Cu and Fe. (C) 2010 Elsevier Ireland Ltd. All rights reserved.; State of Sao Paulo Research Foundation (FAPESP); National Institute of Science and Technology of Complex Fluids (INCT-FCx); National Counsel of Technological and Scientific Development (CNPq)

Estudos das propriedades estruturais e ópticas de vidros teluritos; Studies of the structural and optical properties of the tellurite glasses

Giehl, Júlia Maria
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 25/02/2011 PT
Relevância na Pesquisa
46.13%
Vidros teluritos são considerados fortes candidatos para aplicações em lasers e óptica não linear devido a importantes características, como o elevado índice de refração, baixa energia de fônons, baixa temperatura de transição vítrea e sua fácil preparação. Neste trabalho foram produzidas amostras dos sistemas vítreos TeO2- ZnO-Na2O, TeO2-Nb2O5-Na2O e Te2O-Na2O incluindo ou não dopagens de AgNO3 para estudos estruturais e ópticos. As propriedades estruturais e os mecanismos de recombinação destes vidros foram estudados por meio das técnicas de ressonância paramagnética eletrônica, termoluminescência e correntes de despolarização termicamente estimuladas. Já as propriedades ópticas como o coeficiente de absorção linear, índice de refração linear e não linear foram estudadas por meio das técnicas de absorção óptica, acoplamento de prismas e varredura Z. Foram ainda desenvolvidos estudos da precipitação de nanopartículas de prata para o sistema TeO2-ZnO-Na2O com dopagens de AgNO3 com diferentes temperaturas de tratamento térmico. A caracterização das nanopartículas metálicas foi realizada por meio da técnica de absorção óptica auxiliada por microscopia eletrônica de transmissão e espectrometria de energia dispersiva. Foram observadas por ressonância paramagnética eletrônica quatro respostas paramagnéticas dos vidros irradiados com raio ...

Análise, através de tomografia computadorizada, do preparo promovido pelo alargamento cervical em molares inferiores e sua influência na determinação do diâmetro anatômico apical por meio de MEV; Analysis of the cervical preflaring of lower molars by means of cone beam computed tomography, and its influence on the determination of apical gauging by scanning electron microscopy

Casonato Júnior, Homero
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 19/04/2011 PT
Relevância na Pesquisa
45.91%
O objetivo no presente estudo foi avaliar, por meio de tomografia computadorizada cone beam, o transporte do canal, o aumento da área do canal e o desgaste da dentina intrarradicular na região voltada para a furca de molares inferiores com diferentes instrumentos e verificar a influência do desgaste na determinação do instrumento apical inicial (IAI) por meio de MEV. Os dentes foram dispostos (n=10) em três bases de resina (corpos de prova) de acordo com o tipo de preparo cervical e submetidos ao escaneamento em tomógrafo computadorizado de feixe cônico. Em seguida foi realizado o preparo cervical nos canais mesiais G1: Gattes-Glidden 2 e 3 nos canais mesiais e 3 e 4 no distal; G2 LA Axxess 20.06 e 35.06 nos canais mesiais e 35.06 e 45.06 no canal distal. Concluído o preparo do terço cervical os corpos de prova foram submetidos a novo exame tomográfico. O IAI foi determinado inserindo-se passivamente limas tipo K de aço inox, seqüencialmente a partir da lima #10 até obter a sensação de travamento do instrumento no comprimento de trabalho, em seguida este instrumento foi fixado utilizando-se adesivo à base de cianoacrilato para posterior corte apical e observação em MEV. O índice de centralização não mostrou diferença estatística entre os grupos estudados. O aumento percentualda área do canal pós preparo apresentou diferença estatisticamente significante apenas no canal mesio-lingual (p=0...

Análise da perda de estrutura dentinária após desafio abrasivo com diferentes cremes dentais contendo agentes dessensibilizantes; Analysis of loss of dentine structure after challenge with different abrasive toothpastes containing desensitizing agents

Lopes, Raquel Marianna
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 20/01/2015 PT
Relevância na Pesquisa
45.87%
Este estudo in vitro teve como objetivo avaliar a quantidade de perda de tecido dental após ciclos de erosão e abrasão com diferentes cremes dentais contendo ingredientes ativos para o tratamento da hipersensibilidade dentinária. Para tanto, quarenta amostras de dentina radicular (4x4x1,5 mm) foram confeccionadas a partir de terceiros molares humanos hígidos. Estes foram divididos aleatoriamente em 4 grupos (n=10): 1-controle negativo com água destilada, 2-controle positivo com Colgate Total 12, 3-Colgate Pró-Alivio e 4-Sensodyne Repair and Protect. Para o modelo de ciclagem erosiva foi utilizado o refrigerante Coca-Cola® por 5 minutos (4x/dia) a 37?C; e para a ciclagem abrasiva os espécimes foram submetidos a ciclos diários de escovação (2x/dia) com escova elétrica com pressão padronizada (15s). Os espécimes foram avaliados em Perfilometria óptica (n=10) e Microscopia Eletrônica de Varredura Ambiental (n=3) em duas fases distintas. Os dados de ambas as fases foram submetidos à análise estatística. Para a avaliação por perfilometria, a análise de variância ANOVA dois fatores para medidas repetidas mostrou que em todos os tratamentos a superfície dentinária foi afetada com o passar do tempo, havendo progressão da perda dentinária. Porém...

Implantes de matrizes de colágeno isoladas ou associadas às células estromais mesenquimais multipotentes autólogas na reparação tendínea em ovinos

Hernández Tovar, María Cristina
Fonte: Universidade Estadual Paulista (UNESP) Publicador: Universidade Estadual Paulista (UNESP)
Tipo: Tese de Doutorado Formato: xx, 76 f. : il., grafs.
POR
Relevância na Pesquisa
35.98%
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Pós-graduação em Cirurgia Veterinária - FCAV; Este projeto tem como proposta avaliar o comportamento biológico das células estromais mesenquimais multipotentes autólogas associadas ou não às matrizes de colágeno, na reconstrução tendínea. Optou-se em trabalhar com ovinos e, para isso, os ovinos foram submetidos à ferida no tendão flexor superficial do membro torácico esquerdo, que consistiu na realização de uma tenectomia parcial medindo 1,5cm de comprimento e 0,3cm de largura. Aos 30, 60 e 90 dias após o procedimento cirúrgico foram retirados os tendões flexores superficiais dos membros torácicos dos animais e os fragmentos colhidos foram destinados para procedimento histológico, e de microscopia eletrônica de varredura. Nas avaliações histopatológicas evidenciou-se aumento na quantidade de fibroblastos aos 30, 60 e 90 dias após a intervenção cirúrgica, além de uma desorganização severa da matriz colágena nos diferentes grupos. A microscopia eletrônica de varredura mostrou nos tendões do grupo controle (G1) aos 30, 60 e 90 dias após o procedimento cirúrgico, fibras colágenas finas, ramificadas com perda do arranjo, quando comparadas com as fibras colágenas do tendão normal. O grupo G2 apresentou melhor organização das fibras...

Tricot stitched carbon fiber reinforced polymer composite laminates manufactured by resin transfer molding process: C-scan and flexural analysis

Shiino, Marcos Yutaka; Hilario Cioffi, Maria Odila; Jacobus Voorwald, Herman Cornelis; Ortiz, Edmundo Cabral
Fonte: Sage Publications Ltd Publicador: Sage Publications Ltd
Tipo: Artigo de Revista Científica Formato: 1695-1703
ENG
Relevância na Pesquisa
45.92%
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Processo FAPESP: 06/02121-6; Processo FAPESP: 11/01937-0; NC2 (R) tricot stitched carbon preform has been tested to evaluate its potential application in aircraft structures. It is one in a range of stitched fabric group, specially developed by Hexcel Composites, designed to be processed with a RTM6 monocomponent resin. This article aims to evaluate the tricot stitched fabric behavior towards resin flow front in resin transfer molding process, its mechanical performance in bending test, and its structure during C-scan non-destructive inspection. Flexural performance of the laminates and the scatter of the results corresponded well with C-scan ultrasonic maps, where resin pockets near the stitches were distinguished. The fracture area visualization, via photography and scanning electron microscopy techniques, aided to find a few flaws between the stitch yarns, which conducted to a larger scatter of the flexural rupture strength results.

Estudo da composição química e ação inibitória dos extratos obitidos de Punica granatum L. (romã) sobre Candida spp; Study of chemical composition and inihibitory action of extracts from L. (pomegranate) against Candida spp

Paula Cristina Anibal
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 25/08/2010 PT
Relevância na Pesquisa
45.87%
A diversidade de produtos naturais, por muitos anos, inspirou pesquisadores para identificar novos produtos que podem ser, eventualmente, desenvolvidos para novas terapias. Extratos obtidos Punica granatum L. (romã) tem demonstrado diversas atividades, dentre elas, efeito antimicrobiano. Nas últimas duas décadas, infecções por leveduras do gênero Candida cresceram significantemente pelo mundo inteiro, em decorrência do uso prolongado de antifúngicos, ligado ao aumento da resistência a esses fármacos. Sendo assim, pesquisas por novos componentes com ação antifúngica, os quais podem estar presentes nos compostos da P. granatum, justificam este estudo. Os extratos obtidos de diferentes partes do fruto da P. granatum foram testados através da metodologia da concentração inibitória mínima (CIM) frente a dez espécies de Candida spp. e analisados por espectrometria de massas. Foi observado, também, se os extratos produziam efeitos na morfologia e estrutura das leveduras através da microscopia eletrônica de varredura e de transmissão, respectivamente. Os resultados obtidos revelaram-se promissores, pois as cepas testadas foram sensíveis aos extratos, com CIM de 125µg/mL, causando danos em sua morfologia, como irregularidades em sua superfície e em sua parede celular...

Scanning-Beam Electron Microscopy of Mycoplasma pneumoniae

Kammer, Gary M.; Pollack, J. Dennis; Klainer, Albert S.
Fonte: PubMed Publicador: PubMed
Tipo: Artigo de Revista Científica
Publicado em /10/1970 EN
Relevância na Pesquisa
45.82%
The morphology and the existence of a growth cycle of Mycoplasma pneumoniae have not been clearly established. There is disagreement as to whether this organism exists as a spherical or filamentous form, and whether it progresses from filamentous to spherical forms as the organism ages. A scanning-beam electron microscope (SEM) was utilized to provide detailed observations of the cycle of morphological changes during growth phases of M. pneumoniae. Cultures of cells grown and fixed in liquid suspension displayed morphological changes from spherical to filamentous and then to larger round forms. After 8 hr to 2 days of growth (phase I), spherical forms and aggregates were revealed. Two- to 6-day-old growth (phase II) was composed of both straight and branching filaments with bulbous elements situated at intervals along their lengths, and microcolonies composed predominantly of intertwined filaments. Six- to 10-day-old growth (phase III) was characterized by flattened, spherical organisms larger than those observed in phase I, occasional membranes or ghosts, and a paucity of aggregates or microcolonies. Thus, stereo-scan electron microscopic studies suggest that M. pneumoniae undergoes an orderly and sequential metamorphosis during its life cycle.

Phase accuracy in high-resolution electron microscopy of trigonal and orthorhombic purple membrane

Bullough, P. A.; Henderson, R.
Fonte: PubMed Publicador: PubMed
Tipo: Artigo de Revista Científica
Publicado em /09/1990 EN
Relevância na Pesquisa
45.91%
High-resolution images of orthorhombic purple membrane have been obtained by electron cryomicroscopy with spot-scan illumination, and the projection structure at 3.9 Å resolution calculated after image processing and averaging of the data. Since the phases of the structure factors in the projection down the orthorhombic twofold axis should be either 0 or 180°, this offers the first opportunity to make an independent test of the estimated accuracy of high-resolution phases obtained by electron microscopy. The results show the final phases are less accurate than previously estimated by a small factor (1.3). Careful comparison of the new orthorhombic structure to the known trigonal structure shows only small differences after account is taken of a slight difference in the tilt angle of the molecules in the two crystals. This is consistent with the available kinetic and spectroscopic data which show very small differences in behavior.

A charge coupled device camera with electron decelerator for intermediate voltage electron microscopy

Downing, Kenneth H.; Mooney, Paul E.
Fonte: American Institute of Physics Publicador: American Institute of Physics
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
56.01%
Electron microscopists are increasingly turning to intermediate voltage electron microscopes (IVEMs) operating at 300–400 kV for a wide range of studies. They are also increasingly taking advantage of slow-scan charge coupled device (CCD) cameras, which have become widely used on electron microscopes. Under some conditions, CCDs provide an improvement in data quality over photographic film, as well as the many advantages of direct digital readout. However, CCD performance is seriously degraded on IVEMs compared to the more conventional 100 kV microscopes. In order to increase the efficiency and quality of data recording on IVEMs, we have developed a CCD camera system in which the electrons are decelerated to below 100 kV before impacting the camera, resulting in greatly improved performance in both signal quality and resolution compared to other CCDs used in electron microscopy. These improvements will allow high-quality image and diffraction data to be collected directly with the CCD, enabling improvements in data collection for applications including high-resolution electron crystallography, single particle reconstruction of protein structures, tomographic studies of cell ultrastructure, and remote microscope operation. This approach will enable us to use even larger format CCD chips that are being developed with smaller pixels.

Higher Sensitivity Dopamine Measurements with Faster-Scan Cyclic Voltammetry

Keithley, Richard B.; Takmakov, Pavel; Bucher, Elizabeth S.; Belle, Anna M.; Owesson-White, Catarina A.; Park, Jinwoo; Wightman, R. Mark
Fonte: PubMed Publicador: PubMed
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
35.97%
Fast-scan cyclic voltammetry with carbon-fiber microelectrodes has been successfully used to detect catecholamine release in vivo. Generally, waveforms with anodic voltage limits of 1.0 V or 1.3 V (vs. Ag/AgCl) are used for detection. The 1.0 V excursion provides good temporal resolution, but suffers from a lack of sensitivity. The 1.3 V excursion increases sensitivity, but also increases response time which can blur the detection of neurochemical events. Here, the scan rate was increased to improve the sensitivity of the 1.0 V excursion while maintaining the rapid temporal response. However, increasing scan rate increases both the desired faradaic current response and the already large charging current associated with the voltage sweep. Analog background subtraction was used to prevent the analog-to-digital converter from saturating from the high currents generated with increasing scan rate by neutralizing some of the charging current. In vitro results with the 1.0 V waveform showed approximately a four-fold increase in signal to noise ratio with maintenance of the desired faster response time by increasing scan rate up to 2400 V/s. In vivo, stable stimulated release was detected with an approximate four-fold increase in peak current. The scan rate of the 1.3 V waveform was also increased...

Three-Dimensional Electron Microscopy Simulation with the CASINO Monte Carlo Software

Demers, Hendrix; Poirier-Demers, Nicolas; Couture, Alexandre Réal; Joly, Dany; Guilmain, Marc; de Jonge, Niels; Drouin, Dominique
Fonte: PubMed Publicador: PubMed
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
46.03%
Monte Carlo softwares are widely used to understand the capabilities of electron microscopes. To study more realistic applications with complex samples, 3D Monte Carlo softwares are needed. In this paper, the development of the 3D version of CASINO is presented. The software feature a graphical user interface, an efficient (in relation to simulation time and memory use) 3D simulation model, accurate physic models for electron microscopy applications, and it is available freely to the scientific community at this website: www.gel.usherbrooke.ca/casino/index.html. It can be used to model backscattered, secondary, and transmitted electron signals as well as absorbed energy. The software features like scan points and shot noise allow the simulation and study of realistic experimental conditions. This software has an improved energy range for scanning electron microscopy and scanning transmission electron microscopy applications.

Automated Transmission-Mode Scanning Electron Microscopy (tSEM) for Large Volume Analysis at Nanoscale Resolution

Kuwajima, Masaaki; Mendenhall, John M.; Lindsey, Laurence F.; Harris, Kristen M.
Fonte: Public Library of Science Publicador: Public Library of Science
Tipo: Artigo de Revista Científica
Publicado em 26/03/2013 EN
Relevância na Pesquisa
46.02%
Transmission-mode scanning electron microscopy (tSEM) on a field emission SEM platform was developed for efficient and cost-effective imaging of circuit-scale volumes from brain at nanoscale resolution. Image area was maximized while optimizing the resolution and dynamic range necessary for discriminating key subcellular structures, such as small axonal, dendritic and glial processes, synapses, smooth endoplasmic reticulum, vesicles, microtubules, polyribosomes, and endosomes which are critical for neuronal function. Individual image fields from the tSEM system were up to 4,295 µm2 (65.54 µm per side) at 2 nm pixel size, contrasting with image fields from a modern transmission electron microscope (TEM) system, which were only 66.59 µm2 (8.160 µm per side) at the same pixel size. The tSEM produced outstanding images and had reduced distortion and drift relative to TEM. Automated stage and scan control in tSEM easily provided unattended serial section imaging and montaging. Lens and scan properties on both TEM and SEM platforms revealed no significant nonlinear distortions within a central field of ∼100 µm2 and produced near-perfect image registration across serial sections using the computational elastic alignment tool in Fiji/TrakEM2 software...

Solution Structure and Direct Imaging of Fibronectin Adsorption to Solid Surfaces by Scanning Force Microscopy and Cryo-electron Microscopy

Zenhausern, Frédéric; Adrian, Marc; Descouts, P.
Fonte: Oxford University Press Publicador: Oxford University Press
Tipo: Artigo de Revista Científica Formato: text/html
EN
Relevância na Pesquisa
36.01%
In this study, we present the scanning force and electron microscopic visualization of single molecules of fibronectin either frozen hydrated or adsorbed onto metallic and polymeric surfaces with different solid surface tensions. The surfaces were characterized by dynamic contact angle measurements, X-ray photo emission spectroscopy (XPS or ESCA) and scanning force microscopy. The proteins were prepared by fast protein liquid chromatography (FPLC) and characterized by gel electrophoresis. Protein films on surfaces were investigated by surface plasmon resonance spectroscopy and directly imaged by scanning force microscopy. The spreading of the adsorbed fibronectin revealed dependence on the chemical composition and the solid surface tension. Structure of fibronectin in solution as well as on solid interface appeared as an extended straight strand as obtained by imaging with electron and scanning probe microscopies. Imaging of DNA was performed by scanning force microscopy to test the accuracy and reproducibility of our measurements. The measured contour lengths were accurate and the larger widths were caused by convolution of the tip shape and sample. Frictional forces during the scan have been of significant contribution in the imaging mechanism. Moreover...

Estudo das populações de mariposas perfuradoras de frutos (Lepidoptera: Noctuidae) em parreirais dos municípios de Bento Gonçalves e Farroupilha, Rio Grande do Sul

Zenker, Maurício Moraes
Fonte: Pontifícia Universidade Católica do Rio Grande do Sul; Porto Alegre Publicador: Pontifícia Universidade Católica do Rio Grande do Sul; Porto Alegre
Tipo: Dissertação de Mestrado
PORTUGUêS
Relevância na Pesquisa
36.02%
A morfologia da espirotromba de noctuídeos adultos pode indicar diferentes hábitos alimentares. Algumas espécies, conhecidas como mariposas perfuradoras de frutos, apresentam espirotromba adaptada para perfurar a casca (primárias) ou somente a polpa (secundárias) de frutos para se alimentar, causando danos em pomares, enquanto que em outras esse órgão é utilizado para obter néctar e/ou qualquer tipo de matéria orgânica disponível em estado líquido. Visando determinar, através da morfologia da espirotromba, os hábitos alimentares das espécies que ocorrem junto a parreirais na Serra Gaúcha, Rio Grande do Sul, foram realizadas coletas semanais entre novembro de 2007 e março de 2008, durante o período de frutificação, utilizando-se armadilhas luminosa e McPhail em duas áreas de cultivo em Bento Gonçalves e uma em Farroupilha. Os aparelhos bucais de todos os taxa coletados foram analisados em microscópio estereoscópio; foram obtidas imagens de microscopia eletrônica de varredura da espirotromba de espécies representativas com diferentes hábitos alimentares. Objetivando determinar as diferenças morfológicas e morfométricas, foram obtidas imagens de microscopia eletrônica de varredura e realizadas medições de largura e comprimento da espirotromba em vários indivíduos de ambos os sexos de cinco espécies com diferentes hábitos alimentares obtidos das coletas junto a parreirais e de coleções. As coletas resultaram em 187 táxons...

Fracture resistance of over-flared root canals filled with MTA and resin-based material: an in vitro study

Abdo,Salma B.; Masudi,Sam'an Malik; Luddin,Norhayati; Husien,Adam; Khamis,Mohd Fadhli
Fonte: Faculdade de Odontologia de Piracicaba - UNICAMP Publicador: Faculdade de Odontologia de Piracicaba - UNICAMP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2012 EN
Relevância na Pesquisa
46.07%
AIM: To measure the fracture resistance of over-flared roots filled with a variety of materials (gutta-percha-nano HA, resilon-epiphany, composite and mineral trioxide aggregate - MTA) using the Instron machine test and micro-computed tomography (Micro CT) Scan. In addition, scanning electron microscopy (SEM) images were used to illustrate the type of fracture patterns of the specimens. METHODS: One hundred and twenty extracted human mandibular single-rooted premolars were selected. A total of 105 out of the selected teeth were prepared to the working length and over-flared, leaving the apical 5 mm undisturbed. Fifteen samples had no treatment and were used as a positive control group (Group +ve). The 105 test teeth were further divided into 7 groups of 15 samples each. One of the 7 groups was designated as negative control (Group -ve) where teeth were over prepared and left without obturation. Remaining groups were filled with gutta-percha-nanoHA (Group1), gutta-percha-nano HA+composite (Group 2), gutta-percha-nano HA+MTA (Group 3), resilon-epiphany (Group 4), resilon-epiphany+composite (Group 5), and resilon-epiphany+MTA (Group 6). Fracture resistance of all samples was measured using the Instron testing machine. Three samples from each group had the depth of their fracture line measured by Micro CT Scan...

Physical and optical characterisation of Ge-implanted silica

Dowd, A; Llewellyn, David; Elliman, Robert; Luther-Davies, Barry; Samoc, Marek; Fitz Gerald, John
Fonte: Elsevier Publicador: Elsevier
Tipo: Artigo de Revista Científica
Relevância na Pesquisa
45.87%
Ge nanocrystals formed in silica by implantation with 1.0 MeV Ge ions and subsequent annealing at 1100°C were characterised by transmission electron microscopy and Raman spectroscopy. The nanocrystals were found to be approximately spherical in shape and

Development of a fast electromagnetic shutter for compressive sensing imaging in scanning transmission electron microscopy

Béché, Armand; Goris, Bart; Freitag, Bert; Verbeeck, Jo
Fonte: Universidade Cornell Publicador: Universidade Cornell
Tipo: Artigo de Revista Científica
Publicado em 22/09/2015
Relevância na Pesquisa
45.91%
The concept of compressive sensing was recently proposed to significantly reduce the electron dose in scanning transmission electron microscopy (STEM) while still maintaining the main features in the image. Here, an experimental setup based on an electromagnetic shutter placed in the condenser plane of a STEM is proposed. The shutter blanks the beam following a random pattern while the scanning coils are moving the beam in the usual scan pattern. Experimental images at both medium scale and high resolution are acquired and then reconstructed based on a discrete cosine algorithm. The obtained results confirm the predicted usefulness of compressive sensing in experimental STEM even though some remaining artifacts need to be resolved.; Comment: 7 pages, 5 figures

Selection Of Phototrophic Microorganisms For Use As Bioindicators Of Heavy Metals In Natural Environments. Optimization Of High-Resolution Microscopy Techniques

Maldonado Ortiz, Juan
Fonte: [Barcelona] : Universitat Autònoma de Barcelona, Publicador: [Barcelona] : Universitat Autònoma de Barcelona,
Tipo: Tesis i dissertacions electròniques; info:eu-repo/semantics/doctoralThesis; info:eu-repo/semantics/publishedVersion Formato: application/pdf
Publicado em //2011 ENG
Relevância na Pesquisa
56.13%
En aquest treball s'ha determinat l'efecte i la capacitat de captació dels metalls pesants (Pb i Cu) per part de diferents microorganismes fotòtrofs i heteròtrofs, mitjançant tècniques microscòpiques d'alta resolució per tal de seleccionar microorganismes com a indicadors de contaminació per metalls. Per a aquest objectiu, han estat seleccionats diferents microorganismes fotòtrofs aïllats dels tapets microbians del delta de l'Ebre (un ecosistema declarat Parc Natural al 1983) i cianobacteris de la col.lecció de cultius Pasteur (PCC). Aquests tapets on dominen els microorganismes fotosintètics com els cianobacteris i les algues (productors primaris en aquests ecosistemes) poden patir contaminació per compostos tòxics com ara el petroli o els metalls pesants. En aquest treball, els metalls assajats per a la selecció de bioindicadors, han estat el plom (Pb) i el coure (Cu) donat que tots dos s'han detectat en el riu Ebre, i també perquè el primer és molt tòxic i no presenta cap funció biològica i el segon és en canvi un element essencial a baixes dosis i tòxic a elevades dosis. Per determinar la sensibilitat a un metall (tolerància-resistència), s'ha utilitzat la microscopia làser confocal acoblada a un detector espectrofluoromètric (CLSM-λscan). Els resultats demostren que Chroococcus sp. PCC 9106 i la microalga DE2009 presenten una major tolerància a Pb (0.5 mM) que Oscillatoria sp. PCC 7515 i Spirulina sp. 6313 (0...

Fracture resistance of over-flared root canals filled with MTA and resin-based material: an in vitro study

Abdo, Salma B.; Masudi, Sam’an Malik; Luddin, Norhayati; Husien, Adam; Khamis, Mohd Fadhli
Fonte: UNICAMP/FOP Publicador: UNICAMP/FOP
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ;
Publicado em 22/10/2015 POR
Relevância na Pesquisa
46.07%
Aim: To measure the fracture resistance of over-flared roots filled with a variety of materials (gutta-percha-nano HA, resilon-epiphany, composite and mineral trioxide aggregate - MTA) using the Instron machine test and micro-computed tomography (Micro CT) Scan. In addition, scanning electron microscopy (SEM) images were used to illustrate the type of fracture patterns of the specimens. Methods: One hundred and twenty extracted human mandibular singlerooted premolars were selected. A total of 105 out of the selected teeth were prepared to the working length and over-flared, leaving the apical 5 mm undisturbed. Fifteen samples had no treatment and were used as a positive control group (Group +ve). The 105 test teeth were further divided into 7 groups of 15 samples each. One of the 7 groups was designated as negative control (Group -ve) where teeth were over prepared and left without obturation. Remaining groups were filled with gutta-percha-nanoHA (Group1), gutta-percha-nano HA+composite (Group 2), gutta-percha-nano HA+MTA (Group 3), resilon-epiphany (Group 4), resilon-epiphany+composite (Group 5), and resilon-epiphany+MTA (Group 6). Fracture resistance of all samples was measured using the Instron testing machine. Three samples from each group had the depth of their fracture line measured by Micro CT Scan...