Página 1 dos resultados de 1630 itens digitais encontrados em 0.026 segundos

Development and characterization of a new conducting carbon composite electrode

Barsan, Madalina M.; Pinto, Edilson M.; Florescu, Monica; Brett, Christopher M. A.
Fonte: Elsevier B.V. Publicador: Elsevier B.V.
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
35.99%
A new conducting composite flexible material prepared from cellulose acetate (CA) polymer and graphite has been developed and used for the fabrication of electrodes, which were then characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Scanning electron microscopy (SEM) was used to provide information concerning the morphology of the composite electrode surface. The potential window, background currents and capacitance were evaluated by cyclic voltammetry in the pH range from 4.6 to 8.2. The voltammetry of model electroactive species demonstrates a close to reversible electrochemical behaviour, under linear diffusion control. The electroactive area of the composite electrodes increases after appropriate electrode polishing and electrochemical pre-treatment. The electrodes were used as substrate for the electropolymerisation of the phenazine dye neutral red, for future use as redox mediator in electrochemical biosensors. The composite electrodes were also successfully used for the amperometric detection of ascorbate at 0.0 V vs. SCE, and applied to the measurement of ascorbate in Vitamin C tablets; the sensor exhibits high sensitivity and a low detection limit of 7.7 [mu]M. Perspectives for use as a versatile...

Development of a Stent-Based Electrode for Radio Freqency Thermal Ablation Procedure

Almeida, Tony Richard de Oliveira de
Fonte: Universidade de Coimbra Publicador: Universidade de Coimbra
Tipo: Tese de Doutorado
ENG
Relevância na Pesquisa
26.15%
Os stents metálicos auto-expansíveis são endopróteses normalmente utilizadas no tratamento paliativo dos sintomas provocados pelo crescimento de tumores cancerígenos no interior de órgãos tubulares, como sejam o cólon, o esófago ou o ducto biliar. A função deste dispositivo é a desobstrução do órgão por ação mecânica, exercendo uma força radial sobre as paredes do ducto, após ter sido posicionado. O nitinol, uma liga de níquel e titânio que, para além de possuir propriedades mecânicas únicas de elasticidade e de memória de forma, apresenta uma excelente biocompatibilidade, é um material que tem sido usado largamente na construção destas endopróteses. Por outro lado, a ablação térmica por radiofrequência é um procedimento clínico que se tem revelado bastante eficaz no tratamento de tumores localizados em órgãos de tecidos moles. O tratamento de hepatocarcinomas com recurso a esta metodologia é talvez um dos mais documentados na literatura. Nesta dissertação de doutoramento é proposto um elétrodo tubular que tem por base a utilização de um stent metálico auto-expansível. Pretende-se com este elétrodo possibilitar o tratamento de tumores localizados em órgãos tubulares através da ablação térmica por radiofrequência. É proposta uma metodologia que consiste na colocação do elétrodo segundo procedimentos convencionais no local a tratar...

Comportamento eletroquímico de nitrofuranos em eletrodos de diamante dopado com boro-modelo para o mecanismo de ação de nitrocompostos com atividades antichagásica; Electrochemical behaviour of nitrofurans on highly boron doped diamond Electrodes-model for the action mechanism of the nitrocompounds with antichagasic activity

Julião, Murilo Sérgio da Silva
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 09/03/2007 PT
Relevância na Pesquisa
35.9%
O comportamento eletroquímico do Nitrofural (NFZ) foi estudado em eletrodos de pasta de carbono, carbono vítreo e diamante altamente dopado com boro (EDADB) em tampão Britton-Robinson (BR) usando a voltametria cíclica. Os melhores resultados foram obtidos em EDADB, no qual foi possível estabilizar o radical aniônico (R-NO2•‾) em meio predominantemente aquoso, como também estudar a interação entre o R-NO2•‾ a glutationa (GSH), a L-cisteína (Cis) e o O2. Somente na superfície do EDADB, o NFZ foi diretamente reduzido à amina derivada (R-NH2) no intervalo de 2,02 ≤ pH ≤ 4,03 num processo envolvendo seis (6,0 ± 0,4) elétrons e seis prótons. Na faixa de 7,04 ≤ pH ≤ 12 e meio predominantemente aquoso, a etapa de redução desmembrou-se em seus dois componentes: a redução do NFZ ao nitro radical aniônico (R-NO2•‾) e posterior redução deste ao derivado hidroxilamínico (R-NHOH) em processos envolvendo um e três (3,1 ± 0,1) elétrons respectivamente. No sentido anódico da varredura dos voltamogramas cíclicos registrados em pH 8,06, observou-se a oxidação da hidroxilamina ao derivado nitroso (R-NO), num processo envolvendo 2 (1,7 ± 0,2) elétrons e 2 prótons. Além disto...

Estudo da corrosão localizada da liga de alumínio 7475-T761 por espectroscopia de impedância eletroquímica global e local em meio de sulfato de sódio.; Localized corrosion study of aluminum alloy 7475-T761 in sulfate medium using global and local electrochemical impedance spectroscopy.

Ferrari, Jean Vicente
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 20/07/2011 PT
Relevância na Pesquisa
46.21%
As ligas de Al utilizadas na indústria aeroespacial com finalidade estrutural apresentam microestrutura complexa devido aos tratamentos termo-mecânicos a que são submetidas visando o aumento da resistência mecânica. Estas ligas se caracterizam pela presença de um grande número de intermetálicos (IMs) em sua microestrutura, os quais possuem atividade eletroquímica diferente da matriz provocando problemas de corrosão localizada devido à formação de microcélulas galvânicas. Na última década a espectroscopia de impedância eletroquímica (LEIS) tem se estabelecido como uma poderosa técnica na elucidação de aspectos locais relacionados à corrosão, e também tem servido para estudos de aspectos teóricos referentes à distribuição de potencial e corrente na superfície de eletrodos e suas correlações com a reatividade superficial. Esta técnica se baseia na análise de diferentes impedâncias locais obtidas por meio de um bi-eletrodo posicionado nas proximidades do eletrodo de trabalho. O presente trabalho visa estudar a corrosão localizada da liga de Al 7475-T761, utilizada na estrutura de asas e na fuselagem de aeronaves, em meios contendo íons sulfato por meio de espectroscopia de impedância eletroquímica global (EIS) e por LEIS...

Estudo e desenvolvimento de conjuntos membrana-eletrodos (MEA) para célula a combustível de eletrólito polimérico condutor de prótons (PEMFC) com eletrocatalisadores à base de paládio; Study and development of membrane electrode assemblies for proton exchange membrane fuel cell (PEMFC) with palladium based catalysts

Bonifacio, Rafael Nogueira
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 19/11/2013 PT
Relevância na Pesquisa
35.81%
Sistemas de PEMFC são capazes de gerar energia elétrica com alta eficiência e baixa ou nenhuma emissão de poluentes, porém questões de custo e durabilidade impedem sua ampla comercialização. Nesse trabalho foi desenvolvido um MEA com eletrocatalisadores à base de paládio. Foram sintetizados e caracterizados eletrocatalisadores Pd/C, Pt/C e Ligas PdPt/C com diferentes razões entre metais e carbono. Foi realizado um estudo da razão entre ionômero de Nafion e eletrocatalisador para formação de triplas fases reacionais de máximos desempenhos, criado um modelo matemático para transpor esse ajuste para eletrocatalisadores com diferentes razões entre metal e suporte, considerando os aspectos volumétricos da camada catalisadora, e então realizado um estudo da espessura da camada catalisadora. Para as caracterizações foram utilizadas as técnicas de Difração de Raios-X, Microscopias Eletrônicas de Transmissão e de Varredura, Energia Dispersiva de Raios-X, Picnometria a Gás, Porosimetria por Intrusão de Mercúrio, Adsorção de Gás, segundo as equações de BET e BJH, Análise Termo Gravimétrica e feitas as determinações de diâmetros de partículas, de áreas de superfície específica e de parâmetros de rede. Todos os eletrocatalisadores foram usados no preparo de MEAs que foram avaliados em célula unitária de 5 cm2 entre 25 e 100 °C a 1 atm; e a melhor composição foi avaliada também a 3 atm. No estudo dos metais para as reações...

Degradação eletroquímica dos corantes alimentícios amaranto e tartrazina utilizando H2O2 eletrogerado in situ em eletrodo de difusão gasosa (EDG) modificado com ftalocianina de cobalto (II) e cobre (II); Electrochemical degradation of the amaranth and tartrazine food dyes using H2O2 electrogenerated in situ in modified gas diffusion electrode(GDE) with copper (II) and cobalt (II) phthalocyanine

Barros, Willyam Róger Padilha
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 14/08/2014 PT
Relevância na Pesquisa
36.02%
Este trabalho descreve o estudo da geração eletroquímica do H2O2 em eletrólito ácido (H2SO4 (0,1 mol L-1) + K2SO4 (0,1 mol L-1)) e eletrólito alcalino (KOH 1,0 mol L-1) utilizando eletrodo de difusão gasosa (EDG), sendo este fabricado com carbono Printex 6L e modificado com 3,0; 5,0 e 10,0% de ftalocianina de cobalto (II) ou cobre (II). Os experimentos foram realizados em uma célula eletroquímica de compartimento único contendo eletrodo de referência Ag/AgCl, contra eletrodo de Pt e como eletrodo de trabalho foi utilizado o EDG. Nos testes de eletrólise a potencial constante (-0,4 V ≤ E ≤ -1,4 V) durante 90 minutos com O2 pressurizado a 0,2 Bar, a concentração de H2O2 alcançou valor máximo de 178 mg L-1 a - 1,0 V (vs. Ag/AgCl) para o EDG não modificado em eletrólito ácido e em eletrólito alcalino, o valor máximo foi de 3.370 mg L-1 a -1,1 V (vs. Ag/AgCl). Quando incorporada a porcentagem de 5,0% de ftalocianina de cobalto (II) à massa do EGD verificou-se que a concentração de H2O2 alcança valor máximo em 331 mg L-1 a -0,7 V (vs. Ag/AgCl), o que representa um aumento de 86,0% no rendimento da produção de H2O2 em meio ácido, além de uma diminuição de 300 mV no potencial aplicado para formação da espécie oxidante. Para o estudo da degradação eletroquímica foram utilizados os corantes amaranto e tartrazina com concentração de 100 mg L-1. Para o estudo do processo eletro-Fenton homogêneo foram utilizados 0...

Extrusora portátil para fabricação de eletrodo revestido; Portable extruder to produce covered electrode

Bettoni, Diogo
Fonte: Universidade Federal do Rio Grande do Sul Publicador: Universidade Federal do Rio Grande do Sul
Tipo: Trabalho de Conclusão de Curso Formato: application/pdf
POR
Relevância na Pesquisa
36.02%
O processo de Soldagem a Arco com Eletrodo Revestido – “Shielded Metal Arc Welding-SMAW” é um processo manual comumente utilizado para união de componentes metálicos. Neste processo de soldagem é utilizado eletrodo revestido, o qual é composto por dois elementos principais: a alma e o revestimento. Este revestimento é depositado sobre a alma metálica através de um processo de extrusão. Para auxiliar os estudos sobre a influência do material do revestimento no metal depositado, o presente trabalho tem como objetivo desenvolver uma máquina de extrusão manual portátil para a fabricação de eletrodos revestidos com diferentes tipos de substratos. O desenvolvimento desse projeto contempla o estudo das propriedades mecânicas do revestimento sob as condições de extrusão, a análise conceitual das vantagens e desvantagens de diferentes conceitos de máquina extrusora e o projeto detalhado do modelo que apresentar maior facilidade na extrusão da massa verde sobre a alma metálica. Ao final do trabalho é obtido o projeto detalhado de uma máquina capaz de realizar com perfeição e baixo custo a extrusão de eletrodos revestidos.; The Shielded Metal Arc Welding process, SMAW, is a manual process commonly used for joining metal components. In this welding process is used covered electrode...

Monte Carlo simulation of the adsorption of phenol on gold electrodes: a simple model

Neves,Rodrigo S.; Motheo,Artur J.; Fernandes,Fernando M. S. Silva; Fartaria,Rui P. S.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/04/2004 EN
Relevância na Pesquisa
35.7%
Canonical Monte Carlo simulations, at 298 K, of the adsorption of phenol in a dilute aqueous solution on gold electrodes, at the potential of zero charge, are presented. The results suggest that the process occurs in two distinct and successive steps. Adsorption starts with the phenol oxygen atom pointing towards the gold surface and the aromatic ring in a quasi-perpendicular orientation relative to the surface. This is followed by the reorientation of the aromatic ring to a parallel configuration. The effect of the solvent is analyzed through the calculation of the potential of mean force acting on phenol. Despite the simplicity of the model and the interaction potentials used in the simulations, the results are in good agreement with experimental observations, giving insight into the microscopic details of the adsorption process of phenol at low concentrations.

Simultaneous voltammetric determination of dypirone and paracetamol with carbon paste electrode and multivariate calibration methodology

Skeika,Tatiane; Faria,Mariane Ferreira de; Nagata,Noemi; Pessoa,Christiana A.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2008 EN
Relevância na Pesquisa
35.97%
This paper shows the simultaneous electrochemical determination of dypirone (DIP) and paracetamol (PAR) by differential pulse voltammetry technique (DPV) using an unmodified carbon paste electrode. Because of the overlapping of the voltammetric peaks of DIP and PAR, the multivariate calibration methodology based on Partial Least Square Regression (PLSR) was proposed. The data pre-treatment used in this process was mean centering and to choose the principal component number a cross validation procedure was used (leave-one-out). Four principal components were necessary to obtain the lowest PRESS (Prediction Residual Error Sum of Squares). The statistics showed that this model explains approximately 95.5% of the variance from the data set. Using this model, high correlation between real and predicted concentrations was observed. However, for low concentrations of PAR the relative error increased to 25%. Comparing RMSEP (Root Mean Square of Error Prediction) between PAR and DIP, it was observed that it was lower for DIP probably due to higher analytical information in the voltammograms for this analyte when compared to the electrochemical process of PAR, which presented only one potential peak due to its irreversible oxidation.

Modeling Deep Brain Stimulation: Point Source Approximation vs. Realistic Representation of the Electrode

Zhang, Tianhe C; Grill, Warren M
Fonte: PubMed Publicador: PubMed
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
26.18%
Deep brain stimulation (DBS) has emerged as an effective treatment for movement disorders; however, the fundamental mechanisms by which DBS works are not well understood. Computational models of DBS can provide insights into these fundamental mechanisms and typically require two steps: calculation of the electrical potentials generated by DBS and, subsequently, determination of the effects of the extracellular potentials on neurons. The objective of this study was to assess the validity of using a point source electrode to approximate the DBS electrode when calculating the thresholds and spatial distribution of activation of a surrounding population of model neurons in response to monopolar DBS. Extracellular potentials in a homogenous isotropic volume conductor were calculated using either a point current source or a geometrically accurate finite element model of the Medtronic DBS 3389 lead. These extracellular potentials were coupled to populations of model axons, and thresholds and spatial distributions were determined for different electrode geometries and axon orientations. Median threshold differences between DBS and point source electrodes for individual axons varied between −20.5% and 9.5% across all orientations, monopolar polarities...

Electrical stimulation causes rapid changes in electrode impedance of cell-covered electrodes

Newbold, Carrie; Richardson, Rachael; Millard, Rodney; Seligman, Peter; Cowan, Robert; Shepherd, Robert
Fonte: PubMed Publicador: PubMed
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
26.18%
Animal and clinical observations of a reduction in electrode impedance following electrical stimulation encouraged the development of an in vitro model of the electrode-tissue interface. This model was used previously to show an increase in impedance with cell and protein cover over electrodes. In this paper, the model was used to assess the changes in electrode impedance and cell cover following application of a charge-balanced biphasic current pulse train. Following stimulation, a large and rapid drop in total impedance (Zt) and access resistance (Ra) occurred. The magnitude of this impedance change was dependent on the current amplitude used, with a linear relationship determined between Ra and the resulting cell cover over the electrodes. The changes in impedance due to stimulation were shown to be transitory, with impedance returning to pre-stimulation levels several hours after cessation of stimulation. A loss of cells over the electrode surface was observed immediately after stimulation suggesting that the level of stimulation applied was creating localised changes to cell adhesion. Similar changes in electrode impedance were observed for in vivo and in vitro work, thus helping to verify the in vitro model, although the underlying mechanisms may differ. A change in the porosity of the cellular layer was proposed to explain the alterations in electrode impedance in vitro. These in vitro studies provide insight into the possible mechanisms occurring at the electrode-tissue interface in association with electrical stimulation.

Effects of Forward Model Errors on EEG Source Localization

Akalin Acar, Zeynep; Makeig, Scott
Fonte: Springer US Publicador: Springer US
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
26.18%
Subject-specific four-layer boundary element method (BEM) electrical forward head models for four participants, generated from magnetic resonance (MR) head images using NFT (www.sccn.ucsd.edu/wiki/NFT), were used to simulate electroencephalographic (EEG) scalp potentials at 256 recorded electrode positions produced by single current dipoles of a 3-D grid in brain space. Locations of these dipoles were then estimated using gradient descent within five template head models fit to the electrode positions. These were: a spherical model, three-layer and four-layer BEM head models based on the Montreal Neurological Institute (MNI) template head image, and these BEM models warped to the recorded electrode positions. Smallest localization errors (4.1–6.2 mm, medians) were obtained using the electrode-position warped four-layer BEM models, with largest localization errors (~20 mm) for most basal brain locations. When we increased the brain-to-skull conductivity ratio assumed in the template model scalp projections from the simulated value (25:1) to a higher value (80:1) used in earlier studies, the estimated dipole locations moved outwards (12.4 mm, median). We also investigated the effects of errors in co-registering the electrode positions...

The Influence of the Electrode Material on the Sensor Characteristics of SnO2 Thick Film Gas Sensors

Rank, Sven
Fonte: Universität Tübingen Publicador: Universität Tübingen
Tipo: Dissertação
EN
Relevância na Pesquisa
35.99%
A chemoresistive SnO₂ based gas sensor allows for measuring the resistance of the sensing layer between two electrodes in order to provide information about the chemical composition of the ambient atmosphere. It is well documented that besides making possible the resistance measurement, the noble metal electrodes have an impact on the sensing performance because of various reasons. Some of them are purely electric in nature - the electrode gap determines the number of grain-grain boundaries - but there is also an important chemical influence due to the catalytic processes taking place at the three phase boundary: electrode/metal oxide/ambient atmosphere. By only measuring the sensor resistance one experiences all those influences but one also lacks the needed information to be able to understand their causes and the way in which it would be possible to use them. In this work we report on operando measurements performed on screen printed thick-film SnO₂ sensors on Al₂O₃ substrates and on the corresponding model systems for the electrode-metal oxide interface: mixtures between SnO₂ powders and micrometric Au and Pt powders. The measurements were performed in dry and humid air backgrounds in the presence of various CO...

The Development of a Coupled Physics and Kinetics Model to Computationally Predict the Powder to Power Performance of Solid Oxide Fuel Cell Anode Microstructures

Gaweł, Duncan Albert Wojciech
Fonte: Quens University Publicador: Quens University
Tipo: Tese de Doutorado
EN; EN
Relevância na Pesquisa
36.05%
A numerical model was developed to evaluate the performance of detailed solid oxide fuel cell (SOFC) anode microstructures obtained from experimental reconstruction techniques or generated from synthetic computational techniques. The model is also capable of identifying the linear triple phase boundary (TPB) reaction sites and evaluating the effective transport within the detailed structures, allowing a comparison between the structural properties and performance to be conducted. To simulate the cell performance, a novel numerical coupling technique was developed in OpenFOAM and validated. The computational grid type and mesh properties were also evaluated to establish appropriate mesh resolutions to employ when studying the performance. The performance of a baseline synthetic electrode structure was evaluated using the model and under the applied conditions it was observed that the ionic potential had the largest influence over the performance. The model was used in conjunction with a computational synthetic electrode manufacturing algorithm to conduct a numerical powder to power parametric study investigating the effects of the manufacturing properties on the performance. An improvement in the overall performance was observed in structures which maximized the number of reaction sites and had well established transport networks in the ion phase. From the manufacturing parameters studied a performance increase was observed in structures with low porosity and ionic solid volume fractions near the percolation threshold...

Examination of the Pore Space of a Solid Oxide Fuel Cell Electrode: A Computational Approach

Blore, Drew
Fonte: Quens University Publicador: Quens University
Tipo: Tese de Doutorado
EN; EN
Relevância na Pesquisa
35.97%
A numerical model of a solid oxide fuel cell electrode is presented. Using an already established algorithm for dropping spheres as a base, alterations are made to the algorithm to increase the realism of the model. Two changes are analyzed in detail: the ability to drop pore former particles, and the use of pre-agglomerated solid particles. These changes are characterized by their impact on mean pore size, tortuosity, and effective diffusivity. As pore former volume fraction is increased, so too are mean pore size and tortuosity. A higher mean pore size has a beneficial effect on effective diffusivity due to Knudsen effects, while a higher tortuosity has a detrimental effect on effective diffusivity. The impact of mean pore size and tortuosity on diffusivity generally balances and if the impact of porosity is ignored, pore former volume fraction does not greatly affect effective diffusivity. As pore former particle size is increased, mean pore size and tortuosity also increase. Similarly to before, the effects of mean pore size and tortuosity balance. However, effective diffusivity is shown to decrease slightly with an increasing pore former particle size, suggesting a change in tortuosity has greater impact on diffusivity than a change in mean pore size. For a domain constructed with pre-agglomerated particles...

Using of a graphite-polyurethane composite electrode modified with a Schiff base as a bio-inspired sensor in the dopamine determination

Santos,Sidney X. dos; Cavalheiro,Éder T. G.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2014 EN
Relevância na Pesquisa
36.04%
A solid composite electrode based on graphite and polyurethane resin modified with a copper(II) complex of the symmetrical tetradentate Schiff's base type, N, N'-ethylenebis(salicylideneiminato) copper(II) ([Cu(II)Salen]), was evaluated as a bio-inspired sensor using dopamine (DA) as a model analyte. The voltammetric behavior of the modifier [Cu(II)Salen] was investigated at a modified carbon paste electrode and a redox mechanism was proposed. The analytical potentialities of the composite electrode based on graphite and polyurethane resin (GPU) modified with [Cu(II)Salen] (MGPU) were evaluated using DA as probe. MGPU presents best results when compared with GPU without modification, with electrocatalytic effect, indicating that the electrode can be characterized as a bio-inspired sensor. The MGPU electrode was applied in the determination of DA in pharmaceutical formulation using DPV and the results were compared to those obtained with the official method (high performance liquid chromatography, HPLC) as described in US Pharmacopoeia, agreeing within 95% confidence level according to student's t-test.

Degradação eletroquímica/química dos corantes têxteis Reativo Azul 19 e Reativo Preto 5 utilizando eletrodos de diamante dopado com boro e H2O2 eletrogerado em eletrodo de carbono vítreo reticulado; Electrochemical/chemical degradation of textile dyes Reactive Blue 19 and Reactive Black 5 using boron doped diamond electrodes and H2O2 electrogenerated in reticulated vitreous carbon electrode

Vasconcelos, Vanessa Moura
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 11/09/2015 PT
Relevância na Pesquisa
36.12%
A problemática envolvendo os efluentes têxteis decorre principalmente da elevada coloração que apresentam, devido à presença de corantes que além de serem quimicamente estáveis, podem ser tóxicos e/ou carcinogênicos. Logo, quando são descartados in natura no meio ambiente causam problemas estéticos e, sobretudo, ambientais mesmo em baixas concentrações, além da possibilidade de serem nocivos à saúde humana e dos animais. Neste contexto, o objetivo deste trabalho foi estudar a degradação eletroquímica de dois corantes têxteis, Reativo Azul 19 (RA-19) e o Reativo Preto 5 (RP-5) via Oxidação Anódica (OA), utilizando ânodos de Diamante Dopado com Boro (DDB) suportados em titânio ou em nióbio, via processo Eletro-Fenton (EF) e pela combinação dos processos com H2O2 eletrogerado e OA (CP), usando um eletrodo de Carbono Vítreo Reticulado (CVR) como cátodo. As degradações foram realizadas em célula eletroquímica de um compartimento e em reator de fluxo do tipo filtro-prensa com dois compartimentos. A eficiência das degradações foi monitorada pelas técnicas de espectrofotometria no UV-VIS, Cromatografia Líquida de Alta Eficiência (CLAE) e análise do teor de Carbono Orgânico Total (COT). As variáveis estudadas foram densidade de corrente (10-100 mA cm-2 em célula e 4-41 mA cm-2 em reator)...

Computational Modeling of Epidural Cortical Stimulation: Design, Analysis, and Experimental Evaluation

Wongsarnpigoon, Amorn
Fonte: Universidade Duke Publicador: Universidade Duke
Tipo: Dissertação
Publicado em //2011
Relevância na Pesquisa
26.22%

Epidural cortical stimulation (ECS) is a developing therapy for many neurological disorders. However, the mechanisms by which ECS has its effects are unknown, and this lack of understanding has limited the development and optimization of this promising therapy. This dissertation investigates the effects of ECS on the neurons in the cortex and how these effects vary with electrode geometry and location as well as the electrical and geometrical properties of the anatomy.

The effects of ECS on cortical neurons were investigated using a three dimensional computational model of the human precentral gyrus and surrounding anatomy. An epidural electrode was placed above the gyrus, and the model was solved using the finite element method. The outputs of the model included distributions of electric potential, the second spatial derivative of potential (activating function), and current density. The distributions of electric potential were coupled to compartmental models of cortical neurons to quantify the effects of ECS on cortical neurons. A sensitivity analysis was performed to assess how thresholds and distributions of activating function were impacted by changes in the geometrical and electrical properties of the model. In vivo experiments of epidural electrical stimulation of cat motor cortex were performed to measure the effects of stimulation parameters and electrode location on thresholds for evoking motor responses.

During ECS...

Model Based Investigation of Virtual Electrodes of the Multi-Electrode Array for Epiretinal Prostheses

Mueller, Jerel
Fonte: Universidade Duke Publicador: Universidade Duke
Tipo: Tese de Doutorado
Publicado em //2010
Relevância na Pesquisa
26.16%

Visual prostheses are an emerging technology to restore vision in blind

individuals. The level of vision currently attainable with these prostheses is crude and

far from the level of normal vision though. Epiretinal prostheses work by using a multi-

electrode array implanted within the eye on the inner layer of the retina to electrically

stimulate the neural elements beneath the electrodes and produce punctate visual

percepts of light called phosphenes. Stimulation by serially delivering a cathodic

monopolar pulse of current with each electrode in the array would require the least

power to construct pixilated images of the visual scene. There is the possibility of

complex stimulation schemes that may be able to preferentially stimulate the neural

elements between the electrodes of the multi-electrode array by utilizing multiple

electrodes of the array at once though. Although this would require more power, this

would effectively increase the resolution capabilities of the epiretinal prosthesis without

the need to increase the number of electrodes on the multi-electrode array. To

investigate the possibility of such a stimulation scheme...

The dual-electrode DC arc furnace-modelling insights

Reynolds,Q.G
Fonte: Journal of the Southern African Institute of Mining and Metallurgy Publicador: Journal of the Southern African Institute of Mining and Metallurgy
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/10/2011 EN
Relevância na Pesquisa
36.02%
The dual-electrode direct current (DC) arc furnace uses two graphite electrodes, one connected as cathode and one as anode. Such an arrangement avoids some of the design difficulties associated with the anode hearth traditionally used in single-electrode and twincathode DC furnaces, but can introduce other design and operational difficulties including deflection of the arcs toward the furnace walls. Counter-intuitively, both arc jets in a dual-electrode furnace travel from the electrode down to the bath surface, despite carrying electric current in opposite directions-this is suggested in the theory of the governing equations of arc formation, and confirmed by experiments using high-speed photography. The dualelectrode arc system at small pilot-plant scale is studied using a transient magnetohydrodynamic model capable of predicting arc deflection and interaction from first principles, and the results are compared to the behaviour of twin-cathode systems at similar power. Finally, a simple arrangement of the furnace busbars, M configuration, is shown to provide some passive protection against arc deflection.