Página 1 dos resultados de 11703 itens digitais encontrados em 0.019 segundos

Evidence for diffusional coupling in electrochemical thin layers: implications for surface coverage calibration via electrochemical infrared spectroscopy

DEINER, L. J.; NART, F. C.
Fonte: SPRINGER Publicador: SPRINGER
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
66.21%
The time dependence of the concentration of CO2 in an electrochemical thin layer cavity is studied with Fourier transform infrared spectroscopy (FTIR) in order to evaluate the extent to which the thin layer cavity is diffusionally decoupled from the surrounding bulk electrolyte. For the model system of CO on Pt(111) in 0.1 M HClO4, it is found that the concentration of CO2, formed by electro-oxidation of CO, equilibrates rapidly with the surrounding bulk electrolyte. This rapid equilibration indicates that there is diffusion out of the thin layer, even on the short time scales of typical infrared experiments (1-3 min). However, since the measured CO2 absorbance intensity as a function of time is reproducible to within 10%, a new time-dependent method for surface coverage calibration using solution-phase species is proposed.

Aplicação da espectroscopia de infravermelho próximo na caracterização da carga de petróleo para o processo de destilação atmosférica.; Near infrared spectroscopy employment in the petroleum feed stream characterization of an atmospheric distillation process.

Araujo Pantoja, Patricia
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 18/10/2006 PT
Relevância na Pesquisa
66.19%
O conhecimento da composição do petróleo e seus produtos é uma necessidade imprescindível numa refinaria para o ajuste das condições do processo. A espectroscopia de infravermelho próximo (NIR) apresenta-se como uma ferramenta útil para atender esta necessidade, por sua grande potencialidade e aplicações. Neste contexto, foi desenvolvida a metodologia experimental da espectroscopia NIR, através de dois tipos de sensores: transmissão (Sistema de transmitância) e refletância total atenuada ATR (Sistema ATR). Foram analisadas 63 amostras de petróleo no Sistema de transmitância e 41 amostras no Sistema ATR. O API das amostras oscila entre 29,8 e 35,6. Na primeira etapa do trabalho foram obtidos os espectros NIR e cromatografias SIMDIS (Destilação Simulada) das amostras de petróleo, e dos dados obtidos foram eliminadas algumas amostras por apresentar pontos discrepantes. Na segunda fase foi realizada a análise dos espectros no esquema OFF-LINE, em ambos sistemas, escolhendo como faixa espectral a região de 5600 a 6000 cm-1 que corresponde a regiões de sobretons do NIR para os hidrocarbonetos. Também foram realizados testes de repetibilidade dos espectros e testes sobre a influência do comprimento das fibras ópticas utilizadas. Foi realizado um pré-tratamento dos espectros...

Espectroscopias de infravermelho próximo e médio na quantificação de atributos do solo, com ênfase na matéria orgânica e na biomassa microbiana; Near and mid-infrared spectroscopy for quantification of soil atributes, focusing organic matter and microbial biomassl

Ferraresi, Tatiana Maris
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 21/05/2010 PT
Relevância na Pesquisa
66.29%
A matéria orgânica e a biomassa microbiana do solo consistem em sensíveis indicadores de qualidade do solo e de seus estoques de carbono e nitrogênio que, juntamente com a textura, têm auxiliado na escolha de formas de manejo agronômico mais sustentáveis. Os métodos disponíveis para a determinação da matéria orgânica (Walkley-Black modificado da EMBRAPA SOLOS, 1997) e da biomassa microbiana (Vance et al., 1987a) têm sido largamente utilizados, porém possuem alguns inconvenientes como a geração de resíduos altamente tóxicos e a grande demanda de tempo para analisar um pequeno número de amostras. A espectroscopia, por sua vez, tem se mostrado uma alternativa mais rápida e limpa para a identificação e quantificação de compostos orgânicos. Por esse motivo, este trabalho teve como objetivo testar métodos espectroscópicos, tanto no infravermelho próximo (NIRS) quanto no médio com refletância difusa (DRIFTS), com o uso de calibração multivariada, para a quantificação destes indicadores. Os teores de argila, silte, areia, carbono orgânico total e carbono microbiano, assim como o quociente microbiano (CMIC/COT), foram espectrometricamente preditos de modo satisfatório. Em geral, obtiveram-se melhores resultados utilizando DRIFTS.; Organic matter and microbial biomass are sensible ways to indicate soil quality as well as carbon and nitrogen stocks. These properties...

Deriving the magnitude of niobium off-center displacement in ferroelectric niobates from infrared spectroscopy

Lanfredi, S.; Brito, I. A. O.; Polini, C.; Nobre, M. A. L.
Fonte: Springer Publicador: Springer
Tipo: Artigo de Revista Científica Formato: 254-260
ENG
Relevância na Pesquisa
66.17%
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Processo FAPESP: 01/13421-7; Processo FAPESP: 02/05997-9; Processo FAPESP: 07/03510-9; A KSr2Nb5O15 nanopowder was synthesized by a chemical route based on a modified polyol method. The nanopowder exhibits the space group P4bm (ferroelectric) ascribed to the displacement of Nb from the central position of an [NbO6] octahedron, parallel to the c-axis (polarization axis). The magnitude of the niobium off-center, a dagger z, was determined by X-ray diffraction and mid-infrared spectroscopy (FTIR). Analysis of the infrared spectrum carried out using curve fitting based on Gaussian functions has revealed a very strong vibration at 413 cm(-1), ascribed to a bond of the Nb off-center with apical oxygen. A classical molecular theory was applied to derive the force constant of this bond from the vibrational frequency. Using the calculus of energies for the wavelength and the harmonic oscillator, we alternatively derived the a dagger z parameter.

Structural phase transitions of PbZr0.52Ti0.48O3 ceramic: An infrared spectroscopy study

Araujo, E. B.; Guarany, C. A.; Yukimitu, K.; Moraes, João Carlos Silos; Eiras, J. A.
Fonte: Taylor & Francis Ltd Publicador: Taylor & Francis Ltd
Tipo: Artigo de Revista Científica Formato: 1317-1323
ENG
Relevância na Pesquisa
66.17%
The recent discovery of a ferroelectric monoclinic phase in the PbZr1-xTixO3 (PZT) system attained the attention of several researchers due to the possibility of understanding the relationships between structural features and piezoelectric properties. The nature of the monoclinic phase in some PZT compositions remains controversial and unclear. In this work, structural phase transitions of PbZr0.52Ti0.48O3 ceramic were investigated by infrared spectroscopy as a function of temperature. Studies were centered on nu(1)-stretching modes and corresponding half width Wi as a function of temperature. The occurrence of the anomalies in the infrared spectra as a function of temperature suggests the following monoclinic ( LT) -> monoclinic ( HT) -> tetragonal phase transition were observed at 183 K and at 263 K.

Infrared spectroscopy: a tool for determination of the degree of conversion in dental composites

Palmeira Moraes, Luciene Goncalves; Ferreira Rocha, Renata Sanches; Menegazzo, Livia Maluf; Araujo, Eudes Borges; Yukimitu, Keizo; Silos Moraes, Joao Carlos
Fonte: Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru Publicador: Universidade de São Paulo (USP), Faculdade de Odontologia de Bauru
Tipo: Artigo de Revista Científica Formato: 145-149
ENG
Relevância na Pesquisa
66.21%
Infrared spectroscopy is one of the most widely used techniques for measurement of conversion degree in dental composites. However, to obtain good quality spectra and quantitative analysis from spectral data, appropriate expertise and knowledge of the technique are mandatory. This paper presents important details to use infrared spectroscopy for determination of the conversion degree.

Aplicação de quimioterapia e espectroscopia no infravermelho no controle de qualidade de biodiesel e mistura biodiesel/diesel; Application of chemometrics and infrared spectroscopy in the quality control of biodiesel and biodiesel blend

Ingrid Komorizono de Oliveira
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 06/10/2008 PT
Relevância na Pesquisa
66.17%
Cartas de controle multivariadas em conjunto com espectroscopia no infravermelho próximo foram desenvolvidas para avaliar a qualidade de misturas diesel/biodiesel (98% de diesel e 2% de biodiesel). Três cartas foram desenvolvidas baseadas no sinal analítico líquido (NAS): a cartas NAS que corresponde ao analito de interesse (biodiesel nesse caso), a carta de interferente que corresponde a contribuição de outros compostos na amostra (diesel nesse caso) e a carta de resíduos que corresponde a variação não-sistemática. Para cada carta, limites estatísticos foram desenvolvidos utilizando amostras dentro das especificações de qualidade. Foi possível identificar amostras de misturas diesel/biodiesel que estavam fora das especificações relativas à quantidade de biodiesel, biodiesel contaminado com óleo vegetal e diesel contaminado com gasolina. No presente trabalho também foi desenvolvido um modelo de calibração multivariada para a determinação do valor de acidez de biodiesel degradado a partir de espectros na região do infravermelho próximo. O valor de acidez, um dos parâmetros de qualidade do biodiesel, está relacionado com o grau de degradação do biodiesel. O modelo desenvolvido foi baseado no método dos mínimos quadrados parciais (PLS) e validado baseando-se nos cálculos de figuras de mérito. Resultados bastante satisfatórios foram obtidos com erros abaixo de 3...

Determinação de parametros de qualidade em bananas utilizando espectroscopia no infravermelho e calibração multivariada; Determination of banana quality parameters by infrared spectroscopy and multivariate analysis

Luciana Viviani Gallo
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 18/06/2008 PT
Relevância na Pesquisa
66.34%
Neste trabalho foi desenvolvida uma metodologia analítica alternativa para a determinação de parâmetros de qualidade em bananas: pH, acidez titulável e Brix utilizando as espectroscopias no infravermelho médio e próximo em conjunto com calibração multivariada. A estratégia adotada foi obter os espectros na região do infravermelho próximo e médio do fruto e estabelecer um modelo de calibração multivariada, baseada no método dos mínimos quadrados parciais, para prever os diversos parâmetros. Foram utilizadas 54 amostras de banana, em diferentes estágios de maturação. Os espectros foram obtidos a partir da análise da polpa do fruto macerada, da solução obtida após a centrifugação da polpa, e pela técnica “Dry Extract Spectroscopy by infrared Absorption” (DESIR). Um total de 9 modelos foram propostos para a determinação dos parâmetros de qualidade e o melhor resultado para a determinação de pH foi na região do infravermelho médio utilizando a técnica DESIR, com erro médio de 1,32%. Já para a acidez, o melhor modelo obtido foi na região do infravermelho próximo utilizando DESIR, com erro relativo médio de 6,20%. O parâmetro brix apresentou melhores resultados na região do infravermelho médio através da análise da solução...

Mapeamento do córtex visual humano através de uma abordagem multimodal integrando eletroencefalografia e espectroscopia óptica na região do infravermelho próximo; Mapping of the human visual cortex by a multimodal approach integrating electroencephalography and near infrared spectroscopy

Enrique Porfirio Uceda Otero
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 24/08/2009 PT
Relevância na Pesquisa
66.21%
A ativação cerebral envolve um complexo arranjo de processos neuronais, metabólicos e vasculares, que se estende do nível molecular e celular ao nível de extensas zonas corticais. O processo de disparo neuronal requer a restauração de gradientes iônicos e a reciclagem de neurotransmissores, o que implica em um custo energético suprido na forma de trifosfato de adenosina (ATP). A principal via de síntese do ATP é a via aeróbica e se dá pelo metabolismo oxidativo da glicose. Para tanto, o metabolismo cerebral depende de um constante suprimento de glicose e oxigênio, que é mantido pela circulação sanguínea através de uma complexa rede de vasos, que compõe o sistema vascular cerebral. A regulação desse complexo sistema neurovascular-metabólico é objeto de intensa investigação e está no centro do trabalho aqui apresentado, que visa o mapeamento do córtex visual através de uma abordagem multimodal envolvendo eletroencefalografia (EEG) e espectroscopia óptica na região do infravermelho próximo (NIRS - near infrared spectroscopy). O objetivo central deste trabalho foi o desenvolvimento de uma metodologia que permitisse a realização de medidas simultâneas da atividade neuronal, via EEG, e das alterações vasculares associadas a essas...

Aplicação de espectroscopia no infravermelho e análise multivariada para previsão de parâmetros de qualidade em soja e quinoa= : Application of infrared spectroscopy and multivariate analysis to predict quality parameters in soybean and quinoa; Application of infrared spectroscopy and multivariate analysis to predict quality parameters in soybean and quinoa

Daniela Souza Ferreira
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 27/03/2013 PT
Relevância na Pesquisa
66.31%
A avaliação da qualidade nutricional de alimentos é realizada principalmente por meio da determinação dos componentes majoritários, conhecida como composição centesimal (umidade, proteína, cinza, lipídio, carboidrato e fibra). No entanto, os métodos tradicionais de análise são demorados e utilizam materiais, equipamentos e diversos reagentes químicos, que além de oferecerem risco ao analista, geram resíduos tóxicos. Diante disto, uma alternativa para a análise química de grãos, rápida, de baixo custo e sem uso de reagentes químicos é a espectroscopia na região do infravermelho. Visando atender a demanda do Brasil por pesquisas empregando espectroscopia no infravermelho para análise de alimentos, o objetivo desse trabalho foi avaliar a possibilidade de utilização das técnicas espectroscopia no infravermelho próximo (NIR), principalmente, e médio MIR, associadas à quimiometria, para previsão de parâmetros de qualidade da soja brasileira e quinoa da América do Sul. Para comparar a aplicação de NIR e MIR, amostras de soja provenientes do Paraná foram analisadas pelas duas técnicas para previsão da composição centesimal. Os erros relativos (E%) entre os valores de referência e os valores previstos pelos modelos de calibração PLS...

Infrared spectroscopy: a tool for determination of the degree of conversion in dental composites

Moraes,Luciene Gonçalves Palmeira; Rocha,Renata Sanches Ferreira; Menegazzo,Lívia Maluf; Araújo,Eudes Borges de; Yukimito,Keizo; Moraes,João Carlos Silos
Fonte: Faculdade De Odontologia De Bauru - USP Publicador: Faculdade De Odontologia De Bauru - USP
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/04/2008 EN
Relevância na Pesquisa
66.21%
Infrared spectroscopy is one of the most widely used techniques for measurement of conversion degree in dental composites. However, to obtain good quality spectra and quantitative analysis from spectral data, appropriate expertise and knowledge of the technique are mandatory. This paper presents important details to use infrared spectroscopy for determination of the conversion degree.

A Systematic Comparison of Motion Artifact Correction Techniques for Functional Near-Infrared Spectroscopy

Cooper, Robert J.; Selb, Juliette J.; Gagnon, Louis; Phillip, Dorte; Schytz, Henrik W.; Iversen, Helle K.; Ashina, Messoud; Boas, David A.
Fonte: Frontiers Media S.A. Publicador: Frontiers Media S.A.
Tipo: Artigo de Revista Científica
EN_US
Relevância na Pesquisa
66.21%
Near-infrared spectroscopy (NIRS) is susceptible to signal artifacts caused by relative motion between NIRS optical fibers and the scalp. These artifacts can be very damaging to the utility of functional NIRS, particularly in challenging subject groups where motion can be unavoidable. A number of approaches to the removal of motion artifacts from NIRS data have been suggested. In this paper we systematically compare the utility of a variety of published NIRS motion correction techniques using a simulated functional activation signal added to 20 real NIRS datasets which contain motion artifacts. Principle component analysis, spline interpolation, wavelet analysis, and Kalman filtering approaches are compared to one another and to standard approaches using the accuracy of the recovered, simulated hemodynamic response function (HRF). Each of the four motion correction techniques we tested yields a significant reduction in the mean-squared error (MSE) and significant increase in the contrast-to-noise ratio (CNR) of the recovered HRF when compared to no correction and compared to a process of rejecting motion-contaminated trials. Spline interpolation produces the largest average reduction in MSE (55%) while wavelet analysis produces the highest average increase in CNR (39%). On the basis of this analysis...

Corrected near-infrared spectroscopy, C-NIRS : an optical system for extracting hemodynamic signatures unique to the brain

Saager, Rolf B. (1975 - ); Berger, Andrew J.
Fonte: University of Rochester. Publicador: University of Rochester.
Tipo: Tese de Doutorado Formato: Number of Pages:xxv, 179 leaves
ENG
Relevância na Pesquisa
66.27%
Thesis (Ph. D.)--University of Rochester. Institute of Optics, 2008.; We propose a method, dubbed Corrected near-infrared Spectroscopy (C-NIRS), to isolate absorption trends confined to the lower layer of a two-layer turbid medium, as is desired in near-infrared spectroscopy (NIRS) of cerebral hemodynamics. The theory behind the operation of this method has been developed and discussed. Several two-layer Monte-Carlo simulations of NIRS time series were generated using a physiologically relevant range of optical properties. Initial results show that by measuring absorption trends at two source-detector separations and performing a least-squares fit of one to the other, the processed residual signal strongly resembles the simulated absorption properties unique to the bottom-layer. Through this approach, it has been demonstrated that fitting coefficients can be estimated without any a priori knowledge of the optical properties present in the model. An analytical approximation for the least-squares coefficient provides physical insight into the nature of errors and suggests ways to reduce them.
Next, a multi-detector, continuous wave, near-infrared spectroscopy system has been developed to examine whether the hemodynamics of the scalp and brain in adults contain significant layer-like hemodynamic trends. NIRS measurements were made using contrasting geometries...

Cerebral oxygenation monitoring by near-infrared spectroscopy is not clinically useful in patients with severe closed-head injury: a comparison with jugular venous bulb oximetry

Lewis, S.; Myburgh, J.; Thornton, E.; Reilly, P.
Fonte: Williams & Wilkins Publicador: Williams & Wilkins
Tipo: Artigo de Revista Científica
Publicado em //1996 EN
Relevância na Pesquisa
66.39%
OBJECTIVE: To compare continuous jugular venous bulb oximetry and cerebral near-infrared spectroscopy in patients with severe closed head injury. DESIGN: A prospective observational study. SETTING: Intensive care unit of a major teaching hospital. PATIENTS: Adults (n = 10) with severe closed-head injury (Glasgow Coma Scale score of < or = 8). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Jugular venous bulb oximetry, cerebral near-infrared spectroscopy, and cerebral perfusion pressure were measured continuously. A total of 3,691 paired measurements of near-infrared spectroscopy and jugular venous bulb oximetry were analyzed. Poor correlation (r2 = .04) between paired measurements and wide limits of agreement (-13% to +21%) were demonstrated. The mean difference between measurements was +/- 4% and the standard deviation of the mean difference was +/- 8.69%. The data were subsequently grouped according to three clinically significant subgroups of jugular venous bulb oxygen saturation reflecting low ( < 55%), normal (55% to 75%) and high ( > 75%) saturation values. Poor correlation and wide limits of agreement between the two methods of measurement were observed in all groups. Values recorded by near-infrared spectroscopy did not significantly change between the groups...

Feasibility of infrared spectroscopy with pattern recognition techniques to identify a subpopulation of mares at risk of producing foals diagnosed with failure of transfer of passive immunity

Riley, Christopher Bruce; McClure, J. Trenton; Low-Ying, Sarah; Dolenko, B. K.; Somorjai, R. L.; Shaw, R. Anthony
Fonte: Australian Veterinary Association Publicador: Australian Veterinary Association
Tipo: Artigo de Revista Científica
Publicado em //2012 EN
Relevância na Pesquisa
66.28%
OBJECTIVE: To assess the feasibility of a serum-based test using infrared spectroscopy to identify a subpopulation of mares at risk of producing foals susceptible to failure of passive transfer of immunity (FPT) because of mare-associated factors. MATERIALS AND METHODS: Serum was collected from postparturient mares (n = 126) and their foals at 24–72 h of age. A radial immunodiffusion IgG test was used to determine each foal’s serum IgG concentration. Infrared absorbance spectra of dam sera were collected in the wave number range of 400–4000 cm-1. Following data preprocessing, pattern recognition techniques were used to identify spectroscopic information capable of distinguishing between mares with FPT foals and those with normal foals. The sensitivity and specificity of infrared spectroscopy to detect riskpositive mares were calculated. RESULTS: Five wave number regions were identified as optimal for distinguishing between the two groups of mares: 740.9–785.2 cm-1, 796.8–816.0 cm-1, 970.4–993.5 cm-1, 1371.6–1406.3 cm-1 and 1632.0–1659.0 cm-1. Based upon the infrared spectroscopic information within these discriminatory subregions, the spectra provided the risk status of the mares with a classification success rate of 81.0%. The sensitivity of the classification system was 85.7% and specificity was 80.0%. CONCLUSION: This preliminary study demonstrates that infrared spectra of dam serum have the potential to provide the basis for a new periparturient screening method for a subpopulation of mares at risk of having a foal susceptible to FPT. Further developmentmay provide an economic and rapid technique for the pre-parturient assessment of mares.; C.B. Riley...

Monitoramento de reações quimicas empregando espectroscopia no infravermelho; Monitoring of chemical reactions with infrared spectroscopy

Marcello Garcia Trevisan
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 24/04/2009 PT
Relevância na Pesquisa
66.31%
Esta tese tem como objetivo desenvolver um conjunto de metodologias que incorporem a utilização da espectroscopia na região do infravermelho médio/próximo com métodos de estatística multivariada (quimiometria) em aplicações com enfoque em Química Analítica de Processos (QAP). Para atingir estes objetivos, este trabalho conta com um capítulo introdutório e três aplicações propriamente ditas. A introdução (capítulo 1) tem como finalidade divulgar a importância da QAP no âmbito acadêmico e indutrial, além de estabelecer algumas terminologias que serão discutidas nos capítulos posteriores. A primeira aplicação deste trabalho envolve o monitoramento de uma reação de biotransformação que foi acompanhada por infravermelho médio e por cromatografia gasosa, sem etapas de extração ou pré-concentração, permitindo o desenvolvimento de um modelo multivariado capaz de fazer a previsão da concentração dos componentes analisados ao longo do tempo. A segunda e terceira aplicações se referem ao monitoramento espectroscópico da reação de transesterificação do óleo de soja na região do infravermelho médio e próximo, respectivamente. Neste segundo trabalho, foi utilizado um acessório de reflectância total atenuada para monitorar a transesterificação. Os resultados foram comparados com aqueles obtidos por RMN H...

Analysis of saliva by Fourier transform infrared spectroscopy for diagnosis of physiological stress in athletes

Caetano Júnior,Paulo Cesar; Strixino,Juliana Ferreira; Raniero,Leandro
Fonte: Sociedade Brasileira de Engenharia Biomédica Publicador: Sociedade Brasileira de Engenharia Biomédica
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2015 EN
Relevância na Pesquisa
66.2%
Introduction Saliva is the most promising biofluid to monitor the physiological state of athletes, because this method is not invasive and has low contamination risks. The characterization of saliva by Fourier transform infrared spectroscopy (FT-IR) has been studied as an alternative technique to the standard clinical analysis. However, methodological procedures for saliva analysis are not completely clear, especially in terms of influence of storage conditions and sample preparations for infrared analysis. Thawed saliva includes a precipitate, which may influence the infrared spectral analysis. Thus, the purpose of this study was to show the spectral differences of the precipitate, supernatant, and a combo, as well as the best way to classify the physiological state of the athletes by FT-IR. Methods The saliva collection was performed before, immediately after, and two hours after a handball match. After the storage of samples at –20 ○C, it was possible to identify two phases (precipitate and supernatant) and to determine the biochemical differences between the spectra of each phase, which were distinctly analyzed by the second derivative and deconvolution bands. Results The precipitate and supernatant results showed characteristic bands...

Near Infrared Spectroscopy: fundamentals, practical aspects and analytical applications

Pasquini,Celio
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/04/2003 EN
Relevância na Pesquisa
66.26%
This paper intends to review the basic theory of Near Infrared (NIR) Spectroscopy and its applications in the field of Analytical Science. It is addressed to the reader who does not have a profound knowledge of vibrational spectroscopy but wants to be introduced to the analytical potentialities of this fascinating technique and, at same time, be conscious of its limitations. Essential theory background, an outline of modern instrument design, practical aspects, and applications in a number of different fields are presented. This work does not intend to supply an intensive bibliography but refers to the most recent, significant and representative material found in the technical literature. Because this paper has been produced as consequence of the First Workshop on Near Infrared Spectroscopy, whose venue was Campinas - Brazil, as a pre-conference activity of the XI National Meeting on Analytical Chemistry (ENQA), it also depicts the state of the art of NIR spectroscopy in Brazil, pointing out the current achievements and the need to take the technology to a level consistent with this country's economical activities.

Infrared spectroscopy: a tool for determination of the degree of conversion in dental composites

Moraes, Luciene Gonçalves Palmeira; Rocha, Renata Sanches Ferreira; Menegazzo, Lívia Maluf; Araújo, Eudes Borges de; Yukimito, Keizo; Moraes, João Carlos Silos
Fonte: Universidade de São Paulo. Faculdade de Odontologia de Bauru Publicador: Universidade de São Paulo. Faculdade de Odontologia de Bauru
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; Formato: application/pdf
Publicado em 01/04/2008 ENG
Relevância na Pesquisa
66.21%
Infrared spectroscopy is one of the most widely used techniques for measurement of conversion degree in dental composites. However, to obtain good quality spectra and quantitative analysis from spectral data, appropriate expertise and knowledge of the technique are mandatory. This paper presents important details to use infrared spectroscopy for determination of the conversion degree.

Near infrared spectroscopy of forest soils to determine chemical and biological properties related to soil sustainability.

Ludwig, B; Khanna, Partap; Bauhus, Juergen; Hopmans, Peter
Fonte: Elsevier Publicador: Elsevier
Tipo: Artigo de Revista Científica
Relevância na Pesquisa
66.21%
Sustainability related soil changes due to site disturbance during forest harvesting need to be assessed. Near infrared spectroscopy (NIRS) may be useful for assessing large numbers of samples covering a landscape and dispersed over a long time span. This paper presents an evaluation of the use of NIRS to examine a number of chemical and biological soil properties. One hundred and twenty soil samples were collected from two mountain ash sites in Victoria, Australia, 10 years after forest harvesting. The sites had received a number of site and slash management treatments. Samples were analysed for total contents of C, N, microbial C (Cmic) and N (Nmic), various indices of available soil P and N content in salt solutions. To determine the potentially mineralisable C and N, samples were incubated for 264 days during which CO2 evolution and N mineralisation were periodically determined. For each sample the reflectance spectrum was collected in the NIR (including the visible) range between 400 and 2500 nm. The sample set was broken up randomly for the calibration (n = 40) and validation (n = 80) and the entire spectrum was used to obtain the most suited mathematical (zeroth, first, second or third derivative) results. The validation showed that NIRS was very useful to predict the contents of C and N...