Página 1 dos resultados de 7884 itens digitais encontrados em 0.016 segundos

Flow injection amperometric determination of hydrogen peroxide in household commercial products with a ruthenium oxide hexacyanoferrate modified electrode

PENA, Roselyn C.; GAMBOA, Juan C. M.; PAIXAO, Thiago R. L. C.; BERTOTTI, Mauro
Fonte: SPRINGER WIEN Publicador: SPRINGER WIEN
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
66.56%
Hydrogen peroxide was determined in oral antiseptic and bleach samples using a flow-injection system with amperometric detection. A glassy carbon electrode modified by electrochemical deposition of ruthenium oxide hexacyanoferrate was used as working electrode and a homemade Ag/AgCl (saturated KCl) electrode and a platinum wire were used as reference and counter electrodes, respectively. The electrocatalytic reduction process allowed the determination of hydrogen peroxide at 0.0 V. A linear relationship between the cathodic peak current and concentration of hydrogen peroxide was obtained in the range 10-5000 mu mol L(-1) with detection and quantification limits of 1.7 (S/N = 3) and 5.9 (S/N = 10) mu mol L(-1), respectively. The repeatability of the method was evaluated using a 500 mu mol L(-1) hydrogen peroxide solution, the value obtained being 1.6% (n = 14). A sampling rate of 112 samples h(-1) was achieved at optimised conditions. The method was employed for the quantification of hydrogen peroxide in two commercial samples and the results were in agreement with those obtained by using a recommended procedure.; Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); FAPESP (Fundacao de Amparo a Pesquisa de Sao Paulo); CAPES (Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior); Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES); CNPq (Conselho Nacional de Desenvolvimento Cientifico e Tecnologico); Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Hydrogen peroxide and supercritical carbon dioxide: a new bleaching stage for Eucalyptus kraft-O(2) pulps

FRANCISCO, Roberta Pacheco; COLODETTE, Jorge Luiz; CURVELO, Antonio Aprigio da Silva
Fonte: WALTER DE GRUYTER & CO Publicador: WALTER DE GRUYTER & CO
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
66.55%
Kraft pulp is currently bleached largely by the elemental chlorine free (ECF) technology with oxygen, chlorine dioxide, and hydrogen as active agents. This technology brought about significant environmental improvements in relation to standard processes based on chlorine gas and hypochlorite, but there is still need for further improvements. This study presents a novel environmentally friendly bleaching stage - the so-called `hydrogen peroxide in supercritical carbon dioxide`, P((SC-CO2)) - that can be adapted to current ECF bleaching processes, with preference in cases where hydrogen peroxide is already used. In this study, the P((SC-CO2)) stage was evaluated as a replacement to the last peroxide stage of the D(EP)DP bleaching sequence and to the first peroxide stage of the D(EP)DP sequence, for an oxygen delignified eucalypt kraft-O(2) pulp. The P((SC-CO2)) stage was run with 0.5% hydrogen peroxide, at 15% consistency, 70 degrees C, and 73 bar. The reaction time was 30 min. The performances of regular P stages and the new P((SC-CO2)) stage were compared. Promising results were observed with the DEP((SC-CO2))DP sequence; the P((SC-CO2)) decreased kappa number from 2.7 to 2.1, and the hexenuronic acid groups from 17.0 to 12.4 mmol kg(-1). The P((SC-CO2)) stage showed poor performance when applied in the D(EP)DP((SC-CO2)) sequence. It is concluded that the process presents potential but requires further optimization to improve selectivity and efficiency.; Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); CNPq Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (National Council for Scientific and Technological Development); FAPESP Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (Sao Paulo Research Foundation); Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Análise microscópica e histométrica comparativa da aplicação de uma pasta à base de metronidazol e da irrigação com iodeto de sódio e peróxido de hidrogênio para o tratamento de alvéolos dentários infectados de ratos; Microscopic and histometric comparative analysis of a metronidazole ointment application and sodium iodide plus hydrogen peroxide irrigation in the treatment of infected tooth sockets of rats

Rodrigues, Moacyr Tadeu Vicente
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 06/07/2007 PT
Relevância na Pesquisa
66.52%
O processo de reparo em alvéolo infectado de ratos foi avaliado após a utilização de três tipos de tratamento: (1) curetagem e irrigação com soro fisiológico seguida do preenchimento com uma pasta à base de metronidazol a 10%, lidocaína a 2%, menta e carboximetilcelulose, (2) irrigação única com solução de iodeto de sódio a 2% e peróxido de hidrogênio a 3% na proporção 1:1 e (3) irrigação diária, por 3 dias, com solução de iodeto sódio a 2% e peróxido de hidrogênio a 3% na proporção 1:1. Foram utilizados 75 ratos que constituíram os seguintes grupos: Grupo I: alvéolo não infectado (grupo controle positivo); Grupo II: alvéolo infectado sem nenhum tratamento; Grupo III: alvéolo infectado tratado com irrigação única de solução de iodeto de sódio a 2 % e peróxido de hidrogênio a 3% na proporção 1:1; Grupo IV: alvéolo infectado tratado com irrigação diária, por 3 dias, de solução de iodeto de sódio a 2 % e peróxido de hidrogênio a 3% na proporção 1:1; Grupo V: alvéolo infectado submetido à curetagem, irrigação com soro fisiológico e preenchimento com pasta à base de metronidazol a 10% e lidocaína a 2%, carboximetilcelulose e menta. Os animais, em número de 5 em cada grupo foram sacrificados aos 6...

Desenvolvimento de um biossensor de peróxido de hidrogênio de baixo custo baseado na emissão do európio III.; Development of a low cost hydrogen peroxide biosensor based on europium (III).

Silva, Flávia Rodrigues de Oliveira
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 12/03/2008 PT
Relevância na Pesquisa
66.61%
Neste trabalho estudou-se as propriedades ópticas do complexo Európio- Tetraciclina (EuTc), determinando as melhores condições para se obter uma formação eficiente do complexo. Parâmetros ópticos como absorção, emissão, tempo de vida e índice de refração foram obtidos. Variação da concentração de európio no complexo, da temperatura, pH ótimo e tempo de reação das soluções foram analisados. Um aumento na banda de emissão do európio foi observado com adição de peróxido de hidrogênio (HP) na solução. As amostras foram preparadas com pH neutro e a luminescência visível do lantanídeo foi detectada após uma incubação das amostras por 30 min. Um método direto para determinação de peróxido de uréia (PHU) e colesterol, em solução, usando a fluorescência do complexo EuTc é descrito. Os resultados mostram que o complexo é ainda mais sensível para o peróxido de uréia, aumentando a intensidade de emissão em até 40 vezes, do que para o peróxido de hidrogênio, que proporciona um aumento máximo de 15 vezes, quando comparados ao EuTc puro. É reportado também, pela primeira vez, que para a determinação do colesterol total, utilizando-se a sonda EuTc, não há necessidade de adição de enzima na solução...

Estudo da oxidação de matéria orgânica de lixiviados de aterro sanitário por meio de tratamento com ozônio, peróxido de hidrogênio e radiação ultravioleta; Oxidation of organic matter from landfill leachate by ozone, hydrogen peroxide and ultraviolet

Pasqualini, Liana Notari
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 01/10/2010 PT
Relevância na Pesquisa
66.52%
Aterro sanitário é uma forma de destinação final de resíduos sólidos que gera lixiviado durante e após sua operação. O lixiviado é um líquido de elevada carga orgânica e poder poluidor. A presente pesquisa objetivou estudar a remoção da matéria orgânica presente em lixiviado de aterro sanitário bruto ou pré-tratado por air-stripping por meio de processos oxidativos avançados. Avaliou-se a influência do pré-tratamento na eficiência da remoção de matéria orgânica, a possibilidade do uso do conceito de número médio de oxidação do carbono como indicativo de oxidação e a ocorrência de processos sinérgicos na remoção dos parâmetros DQO, COT e cor proveniente da aplicação combinada de oxidantes. Os tratamentos propostos foram: ozônio apenas, ozônio/peróxido de hidrogênio e peróxido de hidrogênio/radiação ultravioleta. As doses de ozônio variaram entre 0,5 e 6 g/L. As doses de peróxido de hidrogênio variaram entre 0,2 e 7,2 g/L. Os tempos de contato de radiação ultravioleta variaram entre 40 e 200 minutos. O pré-tratamento por air-stripping, que visava à remoção de amônia, reduzia carga orgânica e a cor do lixiviado. A eficiência de remoção da DQO e COT foi baixa para todos os tratamentos propostos...

Estudos  espectroscópicos  dos complexos európio-tetraciclinas e suas aplicações na detecção de peróxido de hidrogênio e peróxido de uréia; Spectroscopic studies of europium-tetracyclines complexes and their applications in detection of hydrogen peroxide and urea peroxide

Grasso, Andrea Nastri
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 24/06/2010 PT
Relevância na Pesquisa
66.58%
Neste trabalho foram estudadas as propriedades espectroscópicas do íon európio trivalente complexado à componentes da família das tetraciclinas, a clorotetraciclina, oxitetraciclina e metaciclina, em presença de peróxido de hidrogênio e peróxido de uréia. Para isso foram obtidos os parâmetros ópticos de absorção, emissão, tempo de vida e construídas curvas de calibração para os espectros de luminescência. Realizaram-se experimentos com compostos inorgânicos juntamente com os complexos a fim de verificar a interferência dos mesmos. Também foram realizados estudos para determinação de glicose utilizando os complexos európiotetraciclinas como biossensor. Os resultados mostram que os complexos európiotetraciclinas apresentam um espectro de emissão bem definido na região do visível e, na presença de peróxido de hidrogênio ou peróxido de uréia, há um aumento sensível na luminescência e tempo de decaimento. Assim, os complexos európiotetraciclinas estudados podem ser utilizados como biossensores para determinação dos peróxidos de hidrogênio e uréia, sendo um método realizado em temperatura ambiente, direto e de baixo custo. Um método indireto para determinação de glicose foi estudado através da adição da enzima glicose oxidase aos complexos európiotetraciclinas na presença de glicose no qual há como produto o peróxido de hidrogênio.; In this work were studied the spectroscopic properties of trivalent europium ion complexed with components of tetracycline family...

Fabricação, caracterização do comportamento eletroquímico e aproveitamento analítico de eletrodos modificados para a determinação de peróxido de hidrogênio; Fabrication, characterization of the electrochemical behavior and analytical use of modified electrodes for the determination of hydrogen peroxide

Peña, Roselyn Millaray Castañeda
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 04/11/2011 PT
Relevância na Pesquisa
66.69%
Neste trabalho são apresentados resultados sobre o desenvolvimento de um sensor visando à utilização no monitoramento de peróxido de hidrogênio em amostras de reações Fenton. Superfícies eletródicas modificadas com filmes de poli-azul de metileno (PMB) e óxido de rutênio de hexacianoferrato (RuOHCF) sem e com a incorporação de nanotubos de carbono de paredes múltiplas (MWCNTs) foram utilizadas para a detecção amperométrica de peróxido de hidrogênio. O efeito da ordem de deposição do PMB e MWCNT foi avaliado por voltametria cíclica e espectroscopia de impedância eletroquímica. Estudos realizados por voltametria cíclica indicaram que a superfície modificada com PBM/MWCNTs facilita a redução catódica do peróxido de hidrogênio, processo que ocorre em 0,0 V vs. Ag/AgCl/KCl(sat). O método para a detecção de peróxido de hidrogênio apresentou uma resposta linear de 109 a 3000 µmol L-1, com limite de detecção de 20,7 µmol L-1 e sensibilidade de 108 µA mmol-1 L cm-2. O eletrodo modificado com RuOHCF foi utilizado para a detecção amperométrica de peróxido de hidrogênio por análise em injeção em fluxo (FIA). O método apresentou uma resposta linear de 10 a 5000 µmol L-1 e limite de detecção de 1...

Cinética química do decaimento de cor ICUMSA de caldo de cana-de-açúcar por reação de oxidação com peróxido de hidrogênio em reatores de fase homogênea; Chemical kinetics of the decay of ICUMSA color sugarcane juice by oxidation with hydrogen peroxide in homogeneous phase reactors

Sartori, Juliana Aparecida de Souza
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 04/02/2014 PT
Relevância na Pesquisa
66.63%
O processo de clarificação do caldo de cana-de-açúcar tem sido alvo de vários trabalhos de pesquisa, no intuito de melhorar a qualidade do açúcar obtido, tanto do ponto de vista de novas tecnologias em equipamentos e processos, quanto a respeito do estudo das propriedades físico-químicas da sacarose durante sua decomposição na clarificação. Os POA (Processos Oxidativos Avançados) têm sido aplicados, em especial, ozonização do caldo, tal qual este projeto propõe estudar uma alternativa ao processo convencional de sulfitação do caldo para a obtenção do açúcar cristal branco, através da utilização do peróxido de hidrogênio como agente de redução de cor ICUMSA do caldo e o impacto na degradação da sacarose em compostos não-cristalizáveis, reduzindo o rendimento industrial. Não há relatos na literatura sobre condições ideais de uso do peróxido de hidrogênio, bem como quais alterações essa tecnologia pode ocasionar no caldo. Por isso, buscaram-se elucidar quais são as melhores condições de trabalho e quais fatores influenciam na sua ação, bem como quais são os seus efeitos sobre o caldo tratado. As melhores condições para o uso do peróxido de hidrogênio são: pH entre 3,0 e 7,0, temperatura entre 40 a 70ºC...

Viabilidade econômico-financeira da substituição do dióxido de enxofre pelo peróxido de hidrogênio na cadeia produtiva do açúcar; Economic and Financial Viability of Sulfite Replacement by Hydrogen Peroxide in Sugar Production Chain

Morilla, Cecília Higa Gonzales
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 16/04/2015 PT
Relevância na Pesquisa
66.61%
Do competitivo mercado de produção de açúcar demanda-se um produto detentor de maior qualidade e menor custo. A qualidade do açúcar relaciona-se com o estudo das propriedades físico-químicas da sacarose durante o processo de clarificação. Na produção de açúcar branco utiliza-se o dióxido de enxofre em operação unitária de clarificação. No entanto, o uso desse reagente encontra restrições na indústria alimentícia e nos sistemas agroindustriais, em consequência de suas emissões na atmosfera, assim como, de reações alergênicas possivelmente relacionadas à exposição de resíduos de dióxido de enxofre em alimentos, em indivíduos sensíveis. Tecnologias alternativas, como o uso de peróxido de hidrogênio e de ozônio têm sido propostas. Do uso do peróxido de hidrogênio, de acordo com a literatura consultada, tem-se a diminuição de viscosidade, em conjunto com o aumento de pureza do xarope, pela remoção de compostos não açúcares. Dessa forma, o peróxido de hidrogênio é um eficiente agente oxidante de moléculas produtoras de cor, levando-as a parcial ou total degradação, com destruição permanente de substâncias corantes. A aplicação de peróxido de hidrogênio, no tratamento do caldo de cana-de-açúcar...

Lipid peroxidation and generation of hydrogen peroxide in frozen-thawed ram semen cryopreserved in extenders with antioxidants

Maia, Marciane da Silva; Bicudo, Sony Dimas; Sicherle, Carmen Cecilia; Rodello, Leandro; Saltaren Gallego, Isabel Cristina
Fonte: Elsevier B.V. Publicador: Elsevier B.V.
Tipo: Conferência ou Objeto de Conferência Formato: 118-123
ENG
Relevância na Pesquisa
66.52%
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); The objective of this study was to evaluate the effect of addition of the antioxidants Trolox and catalase to a ram semen cryopreservation extender on lipid peroxidation and hydrogen peroxide generation on the extender and in the thawed semen. Semen was collected from 23 Santa Ines rams (one ejaculate per ram) and diluted at 32 degrees C to a concentration of 400 x 10(6) cells/ml in one of the following solution: Iris-egg yolk extender (control), or the same extender supplemented with either 50 mu M Trolox/10(8) sperm (Trolox), 50 mu g catalase/ml (Catalase) or a combination of Trolox and catalase (Tro + cat, 50 mu M Trolox/10(8) sperm and 50 mu g catalase/ml). The semen was loaded into 0.25 ml straws, cooled and frozen in a programmable freezer and subsequently stored in liquid nitrogen. Prior to evaluation, frozen straws were thawed in a water bath (42 degrees C for 20 s). Lipid peroxidation (LPO), both spontaneous and catalyzed, on the semen and the extender were measured using the thiobarbituric acid (TBA) assay in accordance with the method described by Buege and Aust (1978). Hydrogen peroxide (H(2)O(2)) generation was measured using the horseradish peroxidase-dependent oxidation of phenol red to a derivative with absorbance at 610 nm...

Penetration of 38% hydrogen peroxide into the pulp chamber in bovine and human teeth submitted to office bleach technique

Afonso Camargo, Samira Esteves; Valera, Marcia Carneiro; Ribeiro Camargo, Carlos Henrique; Gasparoto Mancini, Maria Nadir; Menezes, Marcia Maciel
Fonte: Elsevier B.V. Publicador: Elsevier B.V.
Tipo: Artigo de Revista Científica Formato: 1074-1077
ENG
Relevância na Pesquisa
66.55%
This study evaluated the pulp chamber penetration of peroxide bleaching agent in human and bovine teeth after office bleach technique. All the teeth were sectioned 3 mm apical of the cement-enamel junction and were divided into 2 groups, A (70 third human molars) and B (70 bovine lateral incisors), that were subdivided into A1 and B1 restored by using composite resin, A2 and B2 by using glass ionomer cement, and A3 and B3 by using resin-modified glass ionomer cement; A4, A5, B4, and B5 were not restored. Acetate buffer was placed in the pulp chamber, and the bleaching agent was applied for 40 minutes as follows: A1-A4 and B1-B4, 38% hydrogen peroxide exposure and A5 and B5, immersion into distilled water. The buffer solution was transferred to a glass tube in which leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to analysis of variance and Dunnett, Kruskal-Wallis, and Tukey tests (5%). A higher level of hydrogen peroxide penetrated into the pulp chamber in resin-modified glass ionomer cements in bovine (0.79 +/- 0.61 mu g) and human (2.27 +/- 0.41 mu g) groups. The bleaching agent penetration into the pulp chamber was higher in human teeth for any experimental situation. The penetration of the hydrogen peroxide depends on restorative materials...

Lichen metabolites modulate hydrogen peroxide and nitric oxide in mouse macrophages

Carlos, Iracilda Z.; Quilles, Marcela B.; Carli, Camila B. A.; Maia, Danielle C. G.; Benzatti, Fernanda P.; Lopes, Thiago I. B.; Gianini, Aline S.; Brum, Rosenei L.; Vilegas, Wagner; dos Santos, Lourdes C.; Honda, Neli K.
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 664-672
ENG
Relevância na Pesquisa
66.52%
The activities of perlatolic acid (1), atranorin (2), and lecanoric acid (3) and their derivatives, such as orsellinates and β-methyl orsellinates obtained by alcoholysis, were assessed for stimulation of the release of hydrogen peroxide and nitric oxide in cultures of peritoneal macrophage cells from mice. The hydrogen peroxide production was estimated by oxidation of phenol red, while the Griess reagent was used to determine the nitric oxide production. 1 and 4-methoxy-ethyl orsellinate (XVII) were the compounds that induced the greatest release of H 2O 2, whereas n-pentyl orsellinate (IV), iso-propyl orsellinate (V), sec-butyl orsellinate (VI), and XVII induced a small release of NO. These results indicate that lichen products and their derivatives have potential immune-modulating activities. © 2009 Verlag der Zeitschrift für Naturforschung, Tübingen.

Sequential injection lab-on-valve system for the on-line monitoring of hydrogen peroxide in lens care solutions

Vidigal, Susana S.M.P.; Tóth, Ildikó V.; Rangel, António O.S.S.
Fonte: Elsevier Publicador: Elsevier
Tipo: Artigo de Revista Científica
Publicado em //2009 ENG
Relevância na Pesquisa
66.52%
A sequential injection lab-on valve (SI-LOV) method for the enzymatic determination of hydrogen peroxide was developed. The spectrophotometric assay is based on the reaction between hydrogen peroxide and ABTS (2,2′-Azino-bis(3-Ethylbenzothiazoline 6-sulfonic acid)) in the presence of the enzyme HRP (horseradish peroxidase). The produced oxidized ABTS is measured at 410 nm. The sample consumption was 15 μL/assay and the consumption of HRP and ABTS was 34.6 mg L−1 and 0.06 g L−1, respectively with a determination rate of 45 h−1. Relative deviations lower than 9.0% were found when the results were compared to those obtained by the reference procedure in the analysis of bleaches and disinfection solutions for contact lenses. With the incorporation of an in-line dilution (dialysis) process,was possible to attain a response range up to 342 mg L−1 of hydrogen peroxide. The developed methodwas applied to monitor on-line of the disinfection–neutralization process of contact lenses. The study of two different one-step systems for cleaning contact lenses demonstrated that the neutralization of the hydrogen peroxide is completed within 6 h as recommended by the manufactures. The developed flow method was proved to be a useful tool for monitoring the dynamic process of disinfection–neutralization.

Hydrogen peroxide assessment in exhaled breath condensate: condensing equipment-rapid flow injection chemiluminescence method

Vasiliou,Efstathios G.; Makarovska,Yaroslava M.; Pneumatikos,Ioannis A.; Lolis,Nikolaos V.; Kalogeratos,Evangelos A.; Papadakis,Emmanuel K.; Georgiou,Constantinos A.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2007 EN
Relevância na Pesquisa
66.52%
Several biomolecules in Exhaled Breath Condensate (EBC) can be used as breath biomarkers providing useful clinical information concerning inflammatory lung diseases. Hydrogen peroxide has a special place among biomarkers as it can be directly linked to oxidative stress built up in the human body. Methods for hydrogen peroxide in EBC are essential for a vast number of studies spanning from basic studies to disease diagnosis. Methods currently in use are not automated, time-consuming and tedious. Moreover, most condensing equipment in use is not portable. To address these, we developed portable condensing equipment as an extra alternative and a fully automated Flow Injection (FI) - Chemiluminescence method for hydrogen peroxide determination. The proposed condensing equipment provides collection efficiency better than 86% allowing the collection of 2-3 mL sample in 20 min. The method involves mixing a luminol solution stream that is used as sample carrier with a cobalt(II) stream. Reaction of EBC with luminol in the presence of cobalt(II) catalyst produces light proportional to hydrogen peroxide concentration. The automated FI method features a 10 nmol L¹ detection limit and good linearity (r= 0.997). Precision and recoveries are better than 6.0% RSD and 64.9%...

A Comparison of the Bleaching Effectiveness of Chlorine Dioxide and Hydrogen Peroxide on Dental Composite

Agnihotry,Anirudha; Gill,Karanjot S.; Singhal,Deepak; Fedorowicz,Zbys; Dash,Sambit; Pedrazzi,Vinicius
Fonte: Fundação Odontológica de Ribeirão Preto Publicador: Fundação Odontológica de Ribeirão Preto
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2014 EN
Relevância na Pesquisa
66.52%
This study was carried out to verify if composites could be bleached using chlorine dioxide as compared with hydrogen peroxide. 3M ESPE Filtek Z350 Universal Restorative discs were prepared (n=40), with dimensions 5 mm diameter x 2 mm thickness. The discs were divided into 4 groups of 10 discs each. Color assessment was performed by CIEDE2000. The discs were stained with coffee, tea, wine and distilled water (control) solutions for 14 days, 5 hours daily. Color assessment was repeated on stained discs and followed by bleaching of 5 discs from each group using chlorine dioxide and hydrogen peroxide in-office systems. Finally, a last color assessment was performed and compared statistically. DE2000 after bleaching was very close to baseline for both the bleaching agents, although chlorine dioxide showed better results than hydrogen peroxide. After staining, there was a clinically significant discoloration (∆E2000≥3.43) for the tea, coffee and wine groups, and discoloration (∆E2000) was seen more in the wine group as compared to tea and coffee. Overall, the control group (distilled water) had the least color change in the three intervals. After bleaching, the color in all specimens returned close to the baseline. The color differences between bleaching and baseline were less than 3.43 for all groups. The obtained results show that chlorine dioxide is slightly superior to hydrogen peroxide in the bleaching of composites...

The ability of thiourea to scavenge hydrogen peroxide and hydroxyl radicals during the intra-coronal bleaching of bloodstained root-filled teeth

Farmer, D.; Burcham, P.; Marin, P.
Fonte: Australian Dental Assn Inc Publicador: Australian Dental Assn Inc
Tipo: Artigo de Revista Científica
Publicado em //2006 EN
Relevância na Pesquisa
66.68%
Background: Hydrogen peroxide, an agent used in the intra-coronal bleaching of root-filled teeth for over a century, has been shown to diffuse from the pulp chamber to the outer root surface. Furthermore, it has been demonstrated that destructive hydroxyl radicals, the by-products of the bleaching process, have been detected on the external root surface. The control of such diffusion may be of importance in minimizing the risk of invasive cervical resorption (ICR) which has been linked to intra-coronal bleaching of discoloured root-filled teeth using hydrogen peroxide. The aims of the present in vitro study are to quantify the diffusion of hydrogen peroxide and hydroxyl radicals to the outer root surface following intra-coronal bleaching, and to evaluate the ability of thiourea incorporated into the bleaching protocol to scavenge residual hydrogen peroxide and hydroxyl radicals. Methods: Thirty-five single rooted premolar teeth with intact cementum at the cemento-enamel junction were used in this project. Thirty teeth were stained with red blood cells and root-filled with gutta-percha and AH26. The five unstained teeth were root-filled and constituted a negative control (Group 1). The stained teeth were divided equally into the following experimental groups and subjected to various intra-coronal bleaching regimes: Group 2 – ‘walking bleach’ with 20μl 30 per cent w/w hydrogen peroxide; Group 3 – 20μl 30 per cent w/w hydrogen peroxide and thermocatalytically activated; Group 4 – 20μl acidified thiourea; Group 5 – 20μl acidified thiourea and 20μl 30 per cent w/w hydrogen peroxide; Group 6 – 20μl acidified thiourea and 20μl one per cent sodium hypochlorite; Group 7 – 20μl acidified thiourea...

Evaluation of a combined thiourea and hydrogen peroxide regimen to bleach bloodstained teeth

Maiolo, K.; Marin, P.; Bridges, T.; Heithersay, G.
Fonte: Australian Dental Assn Inc Publicador: Australian Dental Assn Inc
Tipo: Artigo de Revista Científica
Publicado em //2007 EN
Relevância na Pesquisa
66.63%
Background: Current techniques for intra-coronal bleaching of stained root-filled teeth employ oxidative bleaching with hydrogen peroxide. However, concern over the potential for invasive cervical resorption following the use of hydrogen peroxide has been expressed by many researchers, and recommendations have been made to limit the use of this agent. A reductive-oxidative bleaching process using a thiourea and hydrogen peroxide regimen is proposed as an effective and safer bleaching combination. The efficacy of this novel bleaching regimen is evaluated in this study. Methods: The study involved a quantitative and qualitative spectrophotometric assessment of the ability of two amine (bleaching) agents, aqueous thiourea and acidified thiourea, to alter the absorption spectra of haemoglobin and methaemoglobin compared to hydrogen peroxide. In addition, extracted premolar teeth discoloured by blood were subjected to different bleaching regimens using amine reducing agents and hydrogen peroxide. The change in the colour of the bloodstained dentine samples was measured at each stage of the bleaching process with a Photometer and Reflectance Densitometer. Comparisons of different treatments were made using a method of least significant difference and/or analysis of variance. Results: Spectrophotometric studies showed that acidified thiourea solution greatly reduced the colour of the haemoglobin and methaemoglobin in the visible range (330–760nm). Aqueous thiourea had no effect on the presence of haemoglobin and methaemoglobin. Reflection Densitometer and Photometer scores indicate that the greatest bleaching effect was achieved by the combined acidified thiourea and hydrogen peroxide regimen. Conclusion: The recognition that bleaching discoloured teeth is a chemical process...

Ultrapurificación de peróxido de hidrógeno; Ultrapurification of hydrogen peroxide

Abejón Elías, Ricardo
Fonte: Universidade de Cantabria Publicador: Universidade de Cantabria
Tipo: Tese de Doutorado
SPA
Relevância na Pesquisa
66.65%
RESUMEN: El descubrimiento y empleo de los semiconductores ha influido de forma decisiva en las profundas modificaciones que han vivido las sociedades avanzadas como consecuencia de la revolución tecnológica de la segunda mitad del siglo XX. De este modo se ha configurado la actual sociedad global, donde las tecnologías de la información y la comunicación se han constituido como el elemento característico e imprescindible del desarrollo científico y tecnológico en el que se basan las actuales formas de vida. Las industrias que emplean materiales semiconductores o fabrican productos basados en los mismos demandan reactivos de calidad electrónica caracterizados por su limitado contenido en impurezas. Entre los reactivos de este tipo con mayor demanda se encuentra el peróxido de hidrógeno. Los procesos de ultrapurificación de peróxido de hidrógeno son necesarios para poder alcanzar los niveles de calidad exigidos por el sector, específicamente en lo referido a impurezas metálicas. La revisión del estado del arte con respecto a las tecnologías disponibles para la ultrapurificación de peróxido de hidrógeno presenta diferentes alternativas que incluyen la destilación, la adsorción, el intercambio iónico y las tecnologías de membranas. El empleo de membranas de ósmosis inversa aparece como una opción prometedora desde el punto de vista del uso más sostenible de los recursos naturales (materiales...

Inactivation of Neosartorya fischeri and Paecilomyces variotii on paperboard packaging material by hydrogen peroxide and heat

Delgado, Denise Aparecida; Sant'Ana, Anderson de Souza; Granato, Daniel; de Massaguer, Pilar Rodriguez
Fonte: ELSEVIER SCI LTD; OXFORD Publicador: ELSEVIER SCI LTD; OXFORD
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
66.6%
This study reports on the influence of heat and hydrogen peroxide combination on the inactivation kinetics of two heat resistant molds: Neosartorya fischeri and Paecilomyces variotii. Spores of different ages (1 and 4 months) of these molds were prepared and D-values (the time required at certain temperature/hydrogen peroxide combination to inactivate 90% of the mold ascospores) were determined using thermal death tubes. D-values found for P. variotii ranged from 1.2 to 25.1 s after exposure to different combinations of heat (40 or 60 degrees C) and hydrogen peroxide (35 or 40% w/w) while for N. fischeri they varied from 2.7 to 14.3 s after exposure to the same hydrogen peroxide concentrations and higher temperatures (60 or 70 degrees C). The influence of temperature and hydrogen peroxide concentration on the d-values varied with the genus of mold and their ages. A synergistic effect of heat and hydrogen peroxide in reducing D-values of Paecilomyces variotti and N. fischeri has been observed. In addition to strict control of temperature, time and hydrogen concentration, hygienic storage and handling of laminated paperboard material must be considered to reduce the probability of package's contamination. All these measures together will ensure package's sterility that is imperative for the effectiveness of aseptic processing and consequently to ensure the microbiological stability of processed foods during shelf-life. (C) 2011 Elsevier Ltd. All rights reserved.; Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq); Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)

Inactivation of Neosartorya fischeri and Paecilomyces variotii on paperboard packaging material by hydrogen peroxide and heat

Delgado, Denise Aparecida; Sant'Ana, Anderson de Souza; Granato, Daniel; de Massaguer, Pilar Rodriguez
Fonte: Elsevier; Oxford Publicador: Elsevier; Oxford
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
66.6%
This study reports on the influence of heat and hydrogen peroxide combination on the inactivation kinetics of two heat resistant molds: Neosartorya fischeri and Paecilomyces variotii. Spores of different ages (1 and 4 months) of these molds were prepared and D-values (the time required at certain temperature/hydrogen peroxide combination to inactivate 90% of the mold ascospores) were determined using thermal death tubes. D-values found for P. variotii ranged from 1.2 to 25.1 s after exposure to different combinations of heat (40 or 60 degrees C) and hydrogen peroxide (35 or 40% w/w) while for N. fischeri they varied from 2.7 to 14.3 s after exposure to the same hydrogen peroxide concentrations and higher temperatures (60 or 70 degrees C). The influence of temperature and hydrogen peroxide concentration on the d-values varied with the genus of mold and their ages. A synergistic effect of heat and hydrogen peroxide in reducing D-values of Paecilomyces variotti and N. fischeri has been observed. In addition to strict control of temperature, time and hydrogen concentration, hygienic storage and handling of laminated paperboard material must be considered to reduce the probability of package's contamination. All these measures together will ensure package's sterility that is imperative for the effectiveness of aseptic processing and consequently to ensure the microbiological stability of processed foods during shelf-life. (C) 2011 Elsevier Ltd. All rights reserved.; Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)