Página 1 dos resultados de 2465 itens digitais encontrados em 0.007 segundos

Implant-supported prosthesis following Branemark protocol on electromyography of masticatory muscles

BERSANI, E.; REGALO, S. C. H.; SIESSERE, S.; SANTOS, C. M.; CHIMELLO, D. T.; OLIVEIRA, R. H. de; SEMPRINI, M.
Fonte: WILEY-BLACKWELL Publicador: WILEY-BLACKWELL
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
36.95%
This research evaluated the effects of Branemark protocol on electromyography of the masseter and temporal muscles. The patients were divided into two groups: Group 1: patients who wore an implant-supported prosthesis in the mandibular arch following Branemark protocol, and maxillary removable complete dentures; Group II: dentate individuals (control). Electromyography was carried out at rest, right (RL) and left (LL) laterality, protrusion and maximum voluntary contraction (MVC). Data were compared by t-test. At rest, a higher electromyographic (EMG) activity was observed in Group I, and the values were significant in the right masseter and left temporal muscles. In RL, there were statistically significant differences for right masseter (P < 0.01), left masseter and temporal muscles and for the left temporal muscle in LL (P < 0.05). In protrusion, Group I presented a higher EMG activity, and there was a statistically significant difference for the right masseter muscle (RM) (P < 0.05). In MVC, the EMG values were higher in Group II (control), but significant just for the right temporal muscle (P < 0.05). In conclusion, individuals with mandibular fixed dentures supported according to the Branemark protocol and maxillary removable complete dentures showed a higher activity of masticatory muscles during the mandibular postural clinical conditions examined; however...

Aplicação do filtro de WIENER para tratamento de sinais eletromiográficos; Application of wiener filter to electromyography signals treatment

Nakashima, Giovana Yuko
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 10/07/2003 PT
Relevância na Pesquisa
36.95%
A eletromiografia consiste no estudo do movimentos dos músculos através dos sinais elétricos emitidos pelos mesmos. Esses sinais são captados por meio de eletrodos (de surpefície ou de agulha), sendo muito suscetíveis a variações e interferências não relacionadas diretamente com o movimento muscular (ruídos). Visando obter dados qualitativamente confiáveis, o processamento digital de sinais fornece como ferramentas os filtros ótimos e adaptativos, que são utilizados quando o sinal desajado está contaminado por ruído. Com a finalidade de diminuir o ruído presente no sinal eletromiográfico, foram implementados os filtros de wiener e wiener adaptativo ao algoritmo LMS (least mean square), tendo a análise da relação sinal/ruído dos sinais obtidos demonstrado que não há diferença significativa entre os filtros. Como conclusão, no tratamento de sinais eletromiográficos, pode-se aplicar tanto o filtro de wiener como o de wiener adaptativo, observando-se que este último apresenta a vantagem de consumir menos tempo de processamento.; Electromyography is the study of muscle moviments through the electrical signal that they emanate. These signals are detected with eletrodes (surface or needle), where variations and interferences not directly related with movement are present (noises). Digital signal processing provides optimal and adaptative filters with the aim to get qualitative reliable data. The filters are used when desired signal is corrupted by noise. With the purpose of noise reduction in electromyography signal...

Confiabilidade dos valores de amplitude da eletromiografia de superfície durante exercícios para membro superior com carga axial e superfície estável e instável; Reliability of surface electromyography amplitude values during exercises for the upper limb with axial load and stable and unstable surfaces

Araujo, Rodrigo Cappato de
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 28/07/2006 PT
Relevância na Pesquisa
36.95%
O objetivo deste estudo foi avaliar a confiabilidade intradia e interdias dos valores de amplitude da eletromiografia de superfície, dos músculos da cintura escapular e membro superior, durante a realização de 3 exercícios isométrico com a extremidade distal do segmento fixa em uma superfície estável e outra superfície instável, com descarga de peso axial controlada para o membro superior. Para tanto, 20 adultos saudáveis realizaram os exercícios push-up, bench-press e wall-press em diferentes níveis de carga (80 e 100% da carga máxima). Os valores de carga produzida por cada um dos exercícios foram registrados de maneira simultânea à eletromiografia. Os sujeitos realizaram três contrações voluntárias máximas (CVM) na posição de prova de função muscular de cada músculo, para obtenção do valor de referência para normalização dos valores de root mean square (RMS) e da integral do envoltório linear (?env). Os sujeitos foram instruídos, a realizarem de forma aleatória, 3 séries de contrações isométricas por 6 segundos em cada exercício, com intervalo de 2 minutos entre as séries e exercícios.Os sinais eletromiográficos dos músculos deltóide porção anterior e posterior, trapézio fibras superiores...

Eletromiografia de superfície dos músculos orbicular da boca, bucinador, supra-hióideos e masseteres de pacientes com disfunção temporomandibular durante exercícios miofuncionais orais; Surface electromyography of the orbicularis oris muscle of the mouth, buccinator, masseter and supra-hyoid in patients with temporomandibular desorders during orofacial myofunctional

Polido, Aline
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 25/09/2009 PT
Relevância na Pesquisa
36.95%
O objetivo deste estudo foi avaliar a atividade elétrica dos músculos da mímica de pacientes com dor muscular mastigatória utilizando eletromiografia de superfície. Foram avaliadas 15 mulheres com dor muscular mastigatória (idade média de 33.4, variando de 22-44), grupo de estudo (GMM) e 21 mulheres (idade média de 28.5, variando de 21-45), do grupo controle (GC) Foram realizadas avaliação clínica fonoaudiológica e eletromiográfica (eletromiógrafo ADS 1200, da Lynx Tecnologia Eletrônica Ltda, eletrodos de disco de prata, descartáveis, gel condutor, auto-adesivos com 10mm de diâmetro por HAL Ind. e Com. LTDA) dos músculos: orbicular dos lábios, bucinador, supra-hióideos e masseter em repouso e nos movimentos: protrusão dos lábios, apertamento dos lábios, inflar bochechas, sorriso fechado e sorriso aberto. Houve diferença significativa entre os grupos: os valores da eletromiografia de repouso foram inferiores para o músculo masseter direito (p=0.012) e esquerdo (p=0.019); nos movimentos, os valores eletromiográficos foram superiores no grupo controle durante os movimentos: protrusão dos lábios bucinador esquerdo (p=0.005); suprahióideo esquerdo (p=0.011); apertamento dos lábios bucinador esquerdo (p=0.005); bucinador direito (p=0.007); supra-hióideo esquerdo (p=0.046); supra-hióideo direito (p=0.039); orbicular superior (p=0.042); inflar as bochechas masseter esquerdo (p=0.021); bucinador esquerdo (p=0.007); bucinador direito (p=0.002); orbicular superior (p=0.039); sorriso fechado masseter esquerdo (p=0.004); masseter direito (p=0.019); bucinador esquerdo (p=0.013); supra-hióideo esquerdo (p=0.046) e no sorriso aberto masseter esquerdo (p=0.030). Desta forma...

Terapia miofuncional orofacial modular em pessoas com disfunção temporomandibular: um estudo eletromiográfico; Orofacial myofunctional therapy in people with temporomandibular disorders: an electromyography study

Senise, Érika Sbeghen
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 17/09/2010 PT
Relevância na Pesquisa
36.95%
O objetivo foi verificar a eficácia da terapia fonoaudiológica modular (intervenção breve) em pacientes portadores de disfunção temporomandibular de origem muscular, por meio de questionário e eletromiografia de superfície. Foram avaliados 15 pacientes, encaminhados pela Disciplina de Traumatologia da Faculdade de Odontologia da USP, com diagnóstico de disfunção temporomandibular do tipo muscular. Foram realizadas avaliações na primeira, sétima e décima terceira sessão fonoaudiológica por meio de questionário e eletromiografia dos músculos orbicular dos lábios, região das bochechas, temporais e masseteres direito e esquerdo, em repouso e nos movimentos de apertamento labial, sorriso fechado e fechamento da mandíbula em máxima contração voluntária. O tratamento foi realizado com um programa de exercícios previamente elaborado. Houve diferença significativa nos seguintes valores: diminuição da dor (p<0,0001); diminuição da dor na músculatura da face (p=0,0078); diminuição da fadiga muscular (p=0,0169); na eletromiografia de repouso foram encontrados a diminuição da atividade muscular do músculo masseter esquerdo nas sessões 1 a 6 (p=0,0172). Nos seguintes movimentos, os valores de RMS foram superiores durante o apertamento labial região da bochecha esquerda (p<0...

Análise eletromiográfica da fadiga muscular na fibromialgia durante atividade funcional; Electromyography fatigue analyses in fibromyalgia patients during a functional activity

Sauer, Juliana Ferreira
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 23/11/2010 PT
Relevância na Pesquisa
37.05%
Introdução: Pacientes fibromiálgicos freqüentemente referem fadiga e estudos apontam esse sintoma como o segundo mais intenso, podendo limitar as atividades de vida diária, aumentar o estresse a até mesmo a dor. Não há um consenso se as queixas de fadiga correspondem a padrões alterados nos mecanismos de fadiga muscular, já que predominam as avaliações com questionários e escalas. O objetivo deste estudo foi avaliar a fadiga muscular em fibromiálgicos por meio da eletromiografia de superfície durante o teste de sentar e levantar. Métodos: Participaram do estudo 49 sujeitos divididos em dois grupos: Grupo Fibromiálgico (n=34) e Grupo Controle (n=15). Os padrões de fadiga muscular foram avaliados pela análise da freqüência mediana (MDF) do sinal eletromiográfico do terço distal do músculo vasto lateral durante o teste de sentar e levantar. A dor pela Escala Visual Analógica (EVA), os sintomas da fibromialgia pelo Questionário do Impacto da Fibromialgia (QIF) e o desempenho no teste de sentar e levantar pelo tempo total utilizado e número de repetições. Todos os participantes foram instruídos a realizar o teste numa velocidade confortável até a exaustão. A coleta da eletromiografia foi feita em três momentos...

Eletromiografia, força de mordida, performance mastigatória e qualidade de vida em indivíduos com comprometimento periodontal; Electromyography, bite force, masticatory performance and quality of life in individuals with periodontal disease

Borges, Tânia de Freitas
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 08/07/2011 PT
Relevância na Pesquisa
36.95%
Entende-se que indivíduos com comprometimento periodontal moderado/avançado generalizado pela reduzida inserção óssea, consequentemente teria sua função mastigatória alterada. No entanto, esse assunto é escasso na literatura, dificultando a identificação dos reais efeitos da doença periodontal na função mastigatória. Por conseguinte, este estudo objetivou comparar a eficiência dos ciclos mastigatórios (eletromiografia), a performance mastigatória (trituração), o limiar de deglutição, a força de mordida e qualidade de vida relacionada à saúde oral - QvO, considerando a proporção altura óssea/comprimento do dente (OA/D). Propôs-se também correlacionar as variáveis estudadas com OA/D e mobilidade dental. Participaram voluntários com condição periodontal saudável à periodontite avançada generalizada (n=24; 23-76 anos), distribuídos em dois grupos (n=12), grupo controle - GC (OA/D<50%) e teste - GT (OA/D> 50%). O registro eletromiográfico foi utilizado para mensurar a Eficiência dos Ciclos Mastigatórios pela integral da envoltória dos músculos masseteres e temporais durante a mastigação do parafilme, “biocápsula”, uva passa e amendoim, além da avaliação do Limiar de Deglutição. A Peformance Mastigatória foi avaliada por meio da mastigação habitual (10 segundos) da “biocápsula” com “beads” e a Força de Mordida máxima na região de molar direita e esquerda pelo dinamômetro. Utilizouse o questionário OHIP-14br como instrumento de avaliação da QvO. Nos testes de comparação aplicou-se Teste t de student para amostras independentes (p<0...

Avaliação do músculo masseter através da eletromiografia de superfície após aplicação do laser de baixa potência em indivíduos submetidos à exodontia de terceiros molares inferiores retidos; Evaluation by surface electromyography of the masseter muscle after low-intensity laser therapy in patients undergoing extraction of retained inferior third molars

Sevilha, Fabio Moschetto
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 19/05/2014 PT
Relevância na Pesquisa
36.95%
A cirurgia de terceiro molar é um dos procedimentos mais realizados na área de cirurgia e traumatologia bucomaxilofaciais, e buscando um aumento na velocidade da recuperação pós-cirúrgica, muitos recursos fisioterápicos são empregados, entre eles a laserterapia e o acompanhamento da evolução pode ser baseado em evidência clínica. Neste trabalho, foi proposto acompanhar a evolução pós-cirúrgica através da utilização do eletromiografia de superfície em dois grupos distintos: pacientes sem fisioterapia com laser no pós-operatório e pacientes tratados no pós-cirúrgico com laserterapia. Realizamos quatro tomadas, no pré-operatório, normalizando, e três no pósoperatório, 7, 14, 21 dias, em amostra de 60 pacientes. Observamos, que no sétimo dia no grupo onde houve a aplicação do laser de baixa intensidade 23,3% dos pacientes ja haviam recuperado sua atividade muscular do préoperatório contra apenas 3,3% do grupo controle, ja no décimo quarto dia 73,3% contra 6,7% do grupo controle e no vigésimo primeiro dia 80% contra 10% do grupo controle. Constatamos através da eletromiografia de superfície que a utilização do laser de baixa intensidade acelera significativamente a recuperação muscular pós-trauma cirúrgico; The surgery for extraction of the retained inferior third molar is one of the most commonly performed procedures in the field of maxillofacial surgery and traumatology. With the aim of accelerating the post-surgical recovery...

Laryngeal electromyography: Technical features

Crespo, A. N.; Kimaid, P. A T; Quagliato, E. M A B; Viana, M. A.; Wolf, A.; Resende, L. A L
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 237-241
ENG
Relevância na Pesquisa
37.05%
Laryngeal Electromyography (LEMG) is an auxiliary diagnostic method used for the comprehension and diagnosis of different neurological diseases that compromise laryngeal function. The most common LEMG technique is the percutaneous insertion of needle electrodes guided by surface anatomical references. We describe techniques for inserting needle electrodes into the tireoaritenoideus (TA), cricotireoideus (CT), cricoaritenoideus lateralis (CAL) and cricoaritenoideus posterioris (CAP) muscles; these are used at UNICAMP laryngology ambulatory; we discuss difficulties found and their proposed solutions. All patients were submitted to otorhinolaryngological, phonoaudiological and laryngeal endoscopy before LEMG. The CAP approach, by digital rotation of the thyroid cartilage was found to be the most difficult, followed by the CAL approach. TA and CT approaches gave no major problems, except with some older and obese patients. A significant complication of the TA approach via thyroid cartilage was a hematoma in one patient which partially obstructed the laryngeal lumen.

Laryngeal electromyography in movement disorders: Preliminary data

Kimaid, Paulo A. T.; Quagliato, Elizabeth M. A. B.; Crespo, Agrício N.; Wolf, Aline; Viana, Maura A.; Resende, Luiz A. L.
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 741-744
ENG
Relevância na Pesquisa
37.12%
This study describes preliminary laryngeal electromyography (LEMG) data and botulinum toxin treatment in patients with dysphonia due to movement disorders. Twenty-five patients who had been clinically selected for botulinum toxin administration were examined, 19 with suspected laryngeal dystonia or spasmodic dysphonia (SD), 5 with vocal tremor, and 1 with Gilles de la Tourette syndrome (GTS). LEMG evaluations were performed before botulinum toxin administration using monopolar electrodes. Electromyography was consistent with dystonia in 14 patients and normal in 5, and differences in frequency suggesting essential tremor in 3 and Parkinson tremors in 2. The different LEMG patterns and significant improvement in our patients from botulinum toxin therapy has led us to perform laryngeal electromyography as a routine in UNICAMP movement disorders ambulatory.

Laryngeal electromyography: Contribution to vocal fold immobility diagnosis

Kimaid, P. A T; Crespo, A. N.; Quagliato, E. M A B; Wolf, A.; Viana, M. A.; Resende, L. A L
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 371-374
ENG
Relevância na Pesquisa
36.95%
Laryngeal Electromyography (LEMG) is a diagnostic test commonly used in patients with vocal fold movement disorder The aim of this study is to describe LEMG in patients with vocalfold immobility. A total of 55 dysphonic patients with vocal fold immobility diagnosed by laryngeal endoscopy were grouped according to probable clinical cause: 1) unknown; 2) traumatic; or 3) tumoral compression. They were submitted to LEMG by percutaneous insertion of concentric needle electrode. LEMG was conclusive in all patients and showed a majority with peripheral nerve injury. LEMG diagnosed peripheral nerve damage in 25 group 1, 12 group 2, and 11 group 3 patients. LEMG was normal in 4 patients, suggesting cricoarytenoid joint fixation. Central nervous system disorders was suggested in 2 and myopathic pattern in 1. As the major cause of vocal fold immobility is peripheral nerve damage, LEMG is an important test to confirm diagnosis.

Surface electromyography of facial muscles during natural and artificial feeding of infants

Gomes, Cristiane F.; Trezza, Ercília M. C.; Murade, Emílio C. M.; Padovani, Carlos R.
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 103-109
ENG
Relevância na Pesquisa
36.95%
Objective: To measure and compare the activity of the masseter, temporalis and buccinator muscles in different infant feeding methods. Method: Cross-sectional study of 60 full-term infants with no intercurrent diseases, aged between two and three months, classified into the following groups: 1) exclusive breastfeeding; 2) breastfeeding plus bottle-feeding; and 3) exclusive breastfeeding plus cup feeding. Surface electromyography was performed during infant feeding. The Krushal-Wallis test was used, complemented by multiple paired comparisons of the groups. A 5% significance level was chosen for the tests. Results: Statistically higher results were verified in the breastfeeding group in relation to the bottle-feeding one, both in the range of movement and the mean contraction of the masseter. With regard to the temporalis muscle, statistically higher results were found in the breastfeeding group comparatively to the bottle-feeding one. As to the buccinator muscle, statistically higher results were observed in the breastfeeding group in relation to the bottle-feeding one, although in this case, the difference concerned only the range of contraction. Conclusion: The similarities between the muscle activity in the breastfeeding and in the cup-feeding groups suggests that cup-feeding can be used as an alternative infant feeding method...

The use of surface electromyography for the study of auricular acupuncture

Politti, Fabiano; Amorim, Cesar Ferreira; Calili, Lilian; de Oliveira Andrade, Adriano; Palomari, Evanisi T.
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 219-226
ENG
Relevância na Pesquisa
37.05%
The advancement of knowledge in neurophysiology has demonstrated that acupuncture is a method of peripheral neural stimulation that promotes local and systemic reflexive responses. The purpose of this study was to determine if surface electromyography can be used as a tool to study the action of auricular acupuncture on striated skeletal muscle. The electromyographic amplitudes of the anterior, middle and posterior deltoid muscle and the upper trapezium muscle with 20%, 40% and 60% of maximal voluntary contraction of 15 healthy volunteers, were analyzed after the individuals were submitted to the auricular acupuncture treatment. The non-parametric Friedman test was used to compare Root Mean Square values estimated by using a 200 ms moving window. Significant results were further analyzed using the Wilcoxon signed rank test. In this exploratory study, the level of significance of each comparison was set to p < 0.05. It was concluded in this study that a surface electromyography can be used as a tool to investigate possible alterations of electrical activity in muscles after auricular acupuncture. However there is still a lack of adequate methodology for its use in this type of study, being that the method used to record the electromyographic signal can also influence the results. © 2008 Elsevier Ltd. All rights reserved.

Estudo da dor facial e da atividade eletromiográfica de músculos mastigatórios em portadores de fibromialgia e distúrbios do sono, com diagnóstico de disfunção temporomandibular; Facial pain evaluation and electromyography activity of masticatory muscles in fibromyalgia and sleep disorders patients with diagnosis of temporomandibular disorder

Maísa Soares Gui
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 25/03/2011 PT
Relevância na Pesquisa
37.05%
A prevalência e a coexistência das Disfunções Temporomandibulares (DTM) na Síndrome Fibromiálgica (SFM) têm sido frequentemente estudadas na literatura, no entanto os estudos que correlacionem as duas condições de dor crônica e a eletromiografia são escassos. Além disso, os distúrbios do sono representam um fator perpetuador da dor na SFM. Desse modo realizou-se uma revisão bibliográfica buscando conhecer a relação entre os distúrbios do sono e os sintomas da fibromialgia e sua importância na avaliação dos fibromiálgicos por meio de levantamento bibliográfico do período de 1990-2009. A literatura demonstrou uma alta prevalência de distúrbios do sono em pacientes portadores de fibromialgia e uma relevante relação entre as anormalidades no padrão do sono e o sintoma da dor crônica. Assim, com o objetivo de avaliar a dor, a qualidade do sono e de vida e a atividade eletromiográfica de músculos mastigatórios, bem como a presença de DTM em portadoras da SFM, caracterizando a dor facial destes pacientes, foi realizado primeiramente um estudo piloto a fim de refinar a metodologia e averiguar as hipóteses formuladas, no qual dez mulheres portadoras de SFM participaram, e concluímos preliminarmente que há associação entre o aumento da dor facial e o aumento da atividade elétrica de músculos mastigatórios na SFM...

Laryngeal electromyography in movement disorders: preliminary data

Kimaid,Paulo A.T.; Quagliato,Elizabeth M.A.B.; Crespo,Agrício N.; Wolf,Aline; Viana,Maura A.; Resende,Luiz A.L.
Fonte: Academia Brasileira de Neurologia - ABNEURO Publicador: Academia Brasileira de Neurologia - ABNEURO
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/09/2004 EN
Relevância na Pesquisa
37.05%
This study describes preliminary laryngeal electromyography (LEMG) data and botulinum toxin treatment in patients with dysphonia due to movement disorders. Twenty-five patients who had been clinically selected for botulinum toxin administration were examined, 19 with suspected laryngeal dystonia or spasmodic dysphonia (SD), 5 with vocal tremor, and 1 with Gilles de la Tourette syndrome (GTS). LEMG evaluations were performed before botulinum toxin administration using monopolar electrodes. Electromyography was consistent with dystonia in 14 patients and normal in 5, and differences in frequency suggesting essential tremor in 3 and Parkinson tremors in 2. The different LEMG patterns and significant improvement in our patients from botulinum toxin therapy has led us to perform laryngeal electromyography as a routine in UNICAMP movement disorders ambulatory.

Electromyography function, disability degree, and pain in leprosy patients undergoing neural mobilization treatment

Véras,Larissa Sales Téles; Vale,Rodrigo Gomes de Souza; Mello,Danielli Braga de; Castro,José Adail Fonseca de; Lima,Vicente; Trott,Alexis; Dantas,Estélio Henrique Martin
Fonte: Sociedade Brasileira de Medicina Tropical - SBMT Publicador: Sociedade Brasileira de Medicina Tropical - SBMT
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/02/2012 EN
Relevância na Pesquisa
37.12%
INTRODUCTION: This study aimed to evaluate the effect of the neural mobilization technique on electromyography function, disability degree, and pain in patients with leprosy. METHODS: A sample of 56 individuals with leprosy was randomized into an experimental group, composed of 29 individuals undergoing treatment with neural mobilization, and a control group of 27 individuals who underwent conventional treatment. In both groups, the lesions in the lower limbs were treated. In the treatment with neural mobilization, the procedure used was mobilization of the lumbosacral roots and sciatic nerve biased to the peroneal nerve that innervates the anterior tibial muscle, which was evaluated in the electromyography. RESULTS: Analysis of the electromyography function showed a significant increase (p<0.05) in the experimental group in both the right (Δ%=22.1, p=0.013) and the left anterior tibial muscles (Δ%=27.7, p=0.009), compared with the control group pre- and post-test. Analysis of the strength both in the movement of horizontal extension (Δ%right=11.7, p=0.003/Δ%left=27.4, p=0.002) and in the movement of back flexion (Δ%right=31.1; p=0.000/Δ%left=34.7, p=0.000) showed a significant increase (p<0.05) in both the right and the left segments when comparing the experimental group pre- and post-test. The experimental group showed a significant reduction (p=0.000) in pain perception and disability degree when the pre- and post-test were compared and when compared with the control group in the post-test. CONCLUSIONS: Leprosy patients undergoing the technique of neural mobilization had an improvement in electromyography function and muscle strength...

Surface electromyography: proposal of a protocol for cervical muscles

Moraes,Klyvia Juliana Rocha de; Cunha,Daniele Andrade da; Bezerra,Luciana Ângelo; Cunha,Renata Andrade da; Silva,Hilton Justino da
Fonte: CEFAC Saúde e Educação Publicador: CEFAC Saúde e Educação
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/10/2012 EN
Relevância na Pesquisa
37.21%
PURPOSE: to present a proposal of a surface electromyography evaluation method for cervical muscles specific and detailed protocol, with a standardized collection method of electrical signal in these muscles. METHODS: the researchers took as reference the existing publications about this subject which evidenced a need for standardization, clarity, better reproducibility and greater specificity for the surface electromyography evaluation of the upper trapezium and sternocleidomastoid muscles fibers. The proposal preparation process for the current protocol included the cleaning of the target area, placing the electrodes, required tasks in order to collect and register the electrical signal and interpretation of the electromyography signal parameters. This evaluation method was carried out in 24 healthy volunteers of both genders, with an average age of 26 years. We used the electromyography Miotool 400 with 4 channels. RESULT: an evaluation surface electromyography method for upper trapezium and sternocleidomastoid muscles fibers was developed and tested in order to determine the best form of electrical signal data collection for these muscles. CONCLUSION: we submitted a protocol proposal to evaluate the cervical muscles by a surface electromyography...

Use of surface electromyography in phonation studies: an integrative review

Balata,Patricia Maria Mendes; Silva,Hilton Justino da; Moraes,Kyvia Juliana Rocha de; Pernambuco,Leandro de Araújo; Moraes,Sílvia Regina Arruda de
Fonte: Fundação Otorrinolaringologia Publicador: Fundação Otorrinolaringologia
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/09/2013 EN
Relevância na Pesquisa
37.21%
INTRODUCTION: Surface electromyography has been used to assess the extrinsic laryngeal muscles during chewing and swallowing, but there have been few studies assessing these muscles during phonation. OBJECTIVE: To investigate the current state of knowledge regarding the use of surface electromyography for evaluation of the electrical activity of the extrinsic muscles of the larynx during phonation by means of an integrative review. METHOD: We searched for articles and other papers in the PubMed, Medline/Bireme, and Scielo databases that were published between 1980 and 2012, by using the following descriptors: surface electromyography and voice, surface electromyography and phonation, and surface electromyography and dysphonia. The articles were selectedon the basis ofinclusion and exclusion criteria. DATA SYNTHESIS: This was carried out with a cross critical matrix. We selected 27 papers,i.e., 24 articles and 3 theses. The studies differed methodologically with regards to sample size and investigation techniques, making it difficult to compare them, but showed differences in electrical activity between the studied groups (dysphonicsubjects, non-dysphonicsubjects, singers, and others). CONCLUSION: Electromyography has clinical applicability when technical precautions with respect to application and analysis are obeyed. However...

Eletromiografia de superfície e avaliação clínica da mímica facial em pacientes com paralisia facial periférica idiopática; Surface electromyography and clinical assessment of the patients with peripheral facial palsy

Wenceslau, Lais Garcia Capel
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 08/05/2015 PT
Relevância na Pesquisa
37.05%
INTRODUÇÃO: A paralisia facial periférica idiopática apresenta uma variabilidade clínica de sinais e sintomas que dificultam a realização de uma avaliação objetiva e precisa, com influência no estabelecimento de prognóstico. A eletromiografia de superfície é um exame não invasivo e indolor que permite o estudo da atividade elétrica muscular. Visando compreender quais os efeitos da paralisia facial na atividade elétrica muscular durante o tempo de instalação da doença, o objetivo deste estudo foi utilizar a eletromiografia de superfície para captar a resposta elétrica de músculos da face durante a avaliação clínica do sorriso e correlacionar as respostas musculares com o tempo de instalação da paralisia facial. MÉTODOS: Participaram 140 adultos divididos em três grupos: Grupo I - 35 participantes com paralisia facial periférica com instalação de até 3 meses; Grupo II - 35 participantes com paralisia facial periférica com instalação entre 3 a 6 meses; Grupo III - 70 controles saudáveis. Todos foram submetidos à avaliação que consistiu na aplicação de uma escala clínica para avaliação da mímica facial e da realização do exame de eletromiografia de superfície em região de músculos zigomático e risório. RESULTADOS: Há evidências que os grupos com paralisia facial...

Eletromiografia de superfície para avaliação dos músculos do assoalho pélvico feminino: revisão de literatura; Evaluation of female pelvic floor muscles using surface electromyography: literature review

Resende, Ana Paula Magalhães; Nakamura, Mary Uchiyama; Ferreira, Elizabeth Alves Gonçalves; Petricelli, Carla Dellabarba; Alexandre, Sandra Maria; Zanetti, Míriam Raquel Diniz
Fonte: Universidade de São Paulo. Faculdade de Medicina Publicador: Universidade de São Paulo. Faculdade de Medicina
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; ; ; ; ; Formato: application/pdf
Publicado em 01/09/2011 POR
Relevância na Pesquisa
37.05%
A eletromiografia de superfície tem grande importância clínica e de pesquisa para o fisioterapeuta. Apesar de captar a atividade elétrica promovida pelo recrutamento das unidades motoras, há boa correlação entre o número de unidades ativadas e a força muscular. É um dos métodos de maior especificidade na avaliação do assoalho pélvico, embora não haja consenso em relação à sua aplicação. Essa revisão de literatura foi desenvolvida com o objetivo de agrupar as informações sobre o uso da eletromiografia de superfície na avaliação do assoalho pélvico. Foram pesquisados artigos nas bases de dados Medline, PubMed, Lilacs, SciELO e Biblioteca Cochrane, e selecionados os que avaliassem o assoalho pélvico feminino por meio de eletromiografia de superfície. Apesar de sua metodologia ainda carecer de padronização, é um instrumento que deve ser considerado nas pesquisas científicas em nosso meio, pois parece apresentar boa reprodutibilidade e confiabilidade. Pacientes com disfunções do assoalho pélvico possuem alterações no tempo de ativação dos músculos do assoalho pélvico (MAP) e músculos abdominais. Quanto à gestação e puerpério, ainda faltam evidências sobre possíveis alterações da ativação elétrica dos MAP nesses períodos.; Surface electromyography has clinical and research importance for the physiotherapist. Although capturing electrical activity promoted by recruitment of motor units...