Página 1 dos resultados de 164 itens digitais encontrados em 0.001 segundos

Determination of Cr, Fe, Co, Ni, Cu, Zn, As and Pb in liquid chemical waste by energy dispersive X-ray fluorescence

ALMEIDA, E.; TAVARES, G. A.; BENDASSOLLI, J. A.; NASCIMENTO FILHO, V. F.
Fonte: SPRINGER Publicador: SPRINGER
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
27.61%
A method for simultaneous determination of Cr, Fe, Co, Ni, Cu, Zn, As e Pb in liquid chemical waste using Energy Dispersive X-Ray Fluorescence (EDXRF) technique was evaluated. A small sample amount (200 mu L) was dried on a 6.35 mu m thickness Mylar film at 60 degrees C and the analyses were carried out using an EDXRF spectrometer operated with an X-ray Mo tube (Zr filter) at 30 kV/20 mA. The acquisition time was 300 s and the Ga element was utilized as internal standard at 25 mg/L for quantitative analysis. The method trueness was assessed by spiking and the detection limit for those elements ranged from 0.39 to 1.7 mg/L. This method is notable because it assists the choice of the more appropriated waste treatment procedure, in which inter elemental interference is a matter of importance. In addition, this inexpensive method allows a non-destructive determination of the elements from (19)K to (92)U simultaneously.

Paper-based diffusive gradients in thin films technique coupled to energy dispersive X-ray fluorescence spectrometry for the determination of labile Mn, Co, Ni, Cu, Zn and Pb in river water

de Almeida, Eduardo; do Nascimento Filho, Virgilio Franco; Menegario, Amauri Antonio
Fonte: PERGAMON-ELSEVIER SCIENCE LTD; OXFORD Publicador: PERGAMON-ELSEVIER SCIENCE LTD; OXFORD
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
27.74%
The diffusive gradients in thin films (DGT) technique has shown enormous potential for labile metal monitoring in fresh water due to the preconcentration, time-integrated, matrix interference removal and speciation analytical features. In this work, the coupling of energy dispersive X-ray fluorescence (EDXRF) with paper-based DGT devices was evaluated for the direct determination of Mn, Co. Ni, Cu, Zn and Pb in fresh water. The DGT samplers were assembled with cellulose (Whatman 3 MM chromatography paper) as the diffusion layer and a cellulose phosphate ion exchange membrane (Whatman P 81 paper) as the binding agent. The diffusion coefficients of the analytes on 3 MM chromatography paper were calculated by deploying the DGT samplers in synthetic solutions containing 500 mu g L-1 of Mn. Co, Ni, Cu, Zn and Pb (4 L at pH 5.5 and ionic strength at 0.05 mol L-1). After retrieval, the DGT units were disassembled and the P81 papers were dried and analysed by EDXRF directly. The 3 MM chromatographic paper diffusion coefficients of the analytes ranged from 1.67 to 1.87 x 10(-6) cm(2) s(-1). The metal retention and phosphate group homogeneities on the P81 membrane was studied by a spot analysis with a diameter of 1 mm. The proposed approach (DGT-EDXRF coupling) was applied to determine the analytes at five sampling sites (48 h in situ deployment) on the Piracicaba river basin...

"Utilização de duas variantes da fluorescência de raios X (EDXRF e TXRF) na determinação de chumbo em águas e sedimentos" ; Use of two variants of X-ray fluorescence (EDXRF and TXRF) in the determination of lead in waters and sediments

Moraes, Liz Mary Bueno de
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 13/12/2004 PT
Relevância na Pesquisa
28.16%
Este trabalho teve como objetivo principal a utilização de duas variantes da técnica analítica de fluorescência de raios X, dispersiva em energia - EDXRF e reflexão total TXRF, na determinação de Pb em amostras de águas superficiais e subterrâneas, e em sedimentos em suspensão e de fundo. Cinco amostras de cada matriz foram coletadas em uma área contaminada, nas proximidades da desativada fábrica de baterias Indústria Acumuladores Ajax Ltda., localizada no km 229 da rodovia Jaú-Ipaussu, em Bauru, SP. As variantes EDXRF com pré-concentração com APDC e medida direta por TXRF mostraram resultados satisfatórios na determinação de Pb em soluções-padrão e amostra certificada de água natural SRM1640, produzida pelo NIST, obtendo-se concentrações compatíveis com os valores esperados. A primeira técnica resultou em limite de detecção da ordem de 0,70 mg L-1, com tempo de análise de 300 s, melhor que a segunda técnica (4,46 mg L-1), em 200 s. Estas duas variantes também foram utilizadas para outros elementos químicos, como o Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn e Br, onde a EDXRF mostrou também melhores limites de detecção para todos os elementos. Para Ni, Cu e Zn, importantes na indústria de baterias, foram encontrados os limites de 0...

"Caracterização química do material particulado suspenso na atmosfera empregando a fluorescência de raios X dispersiva em energia (EDXRF)"; Chemical characterization of the particulate matter suspended in the atmosphere using the energy dispersive x-ray fluorescence (EDXRF)

Lopes, Fabio
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 18/08/2003 PT
Relevância na Pesquisa
37.83%
O objetivo principal do trabalho foi a avaliação da composição química do material particulado em suspensão na atmosfera em Londrina/PR e Piracicaba/SP. A amostragem foi realizada nas estações de verão e inverno, utilizando-se um amostrador tipo stacker, permitindo a coleta simultânea de particulados fino (partículas com diâmetro aerodinâmico menor que 2,5 'mü'm) e grosso (entre 2,5 e 10 'mü'm), utilizando filtros com 47 mm de diâmetro e diâmetros de poros de 0,4 e 8 'mü'm, respectivamente.Para a análise das amostras, foi utilizada a técnica de fluorescência de raios X por dispersão em energia (EDXRF). As excitações e detecções dos raios X característicos foram realizadas sob atmosfera de ar e vácuo, quantificando-se os elementos químicos na faixa do Al ao Zr. Os espectros de raios X obtidos foram interpretados com o auxílio do programa AXIL. A quantificação dos elementos químicos foi realizada pela metodologia dos parâmetros fundamentais. Foi utilizado também um microscópio eletrônico de varredura acoplado a um sistema de fluorescência de raios X por dispersão em energia para a caracterização química e morfológica dos principais grupos de partículas existentes no material particulado. A metodologia de análise de agrupamento foi usada para identificar as possíveis fontes de emissão ou de formação do material particulado; The main objective of this work was the chemical composition evaluation of the suspended particulate matter in the Londrina/PR and Piracicaba/SP atmospheres. The sampling was accomplished in the summer and winter seasons...

Determinação da concentração de elementos químicos potencialmente tóxicos em aerossóis presentes no interior de uma pequena indústria de fundição de metais, utilizando amostrador temporal e a técnica de fluorescência de raios X; Toxic inorganic elements content in suspended particulate matter inside a small foundry plant by streaker sampler and energy dispersive X-ray fluorescence technique

Massoni, Paulo Rogério
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 09/03/2009 PT
Relevância na Pesquisa
27.61%
Este trabalho foi desenvolvido objetivando a determinação e a avaliação dos perfis temporais da concentração de alguns elementos químicos potencialmente tóxicos presentes no material particulado em suspensão (MPS) no interior de uma pequena indústria de fundição de metais bronze, ferro e alumínio que, em concentrações elevadas, podem acarretar sérios riscos à saúde do trabalhador. Para isso foi utilizado um amostrador temporal de MPS, que coleta amostras de aerossóis em intervalo de tempo pré-programados, separando-os por tamanho: (a) fração fina ou respirável (partículas com diâmetro aerodinâmico menor que 2,5 m, MP2,5) e (b) fração grossa ou inalável (entre 2,5 a 10 m, MP10-2,5), durante todo o período do processo de fundição (da fusão à moldagem). As amostras coletadas, na forma de faixas (strips) sobre um filtro (fração fina) e sobre um impactador (fração grossa), foram analisadas pela técnica de fluorescência de raios X por dispersão de energia (EDXRF), utilizando na excitação um tubo de raios X com alvo de Mo e e na detecção dos raios X característicos um detector semicondutor de Si(Li) acoplado a um analisador de pulsos multicanal, interpretando-se posteriormente os espectros de raios X obtidos pelo aplicativo AXIL. Para algumas amostras também foi feita uma análise com microscópio eletrônico de varredura (SEM/EDS) para se conhecer a morfologia dos particulados. Deste modo foi possível determinar a concentração de elementos químicos potencialmente tóxicos presentes em um ambiente de uma pequena indústria de fundição de metais...

Utilização da técnica de fluorescência de raios X por dispersão em energia (EDXRF) na avaliação do material particulado em suspensão na cidade de Limeira - SP; Using energy dispersive X ray fluorescence (EDXRF) technique to evaluate the suspended particulate matter from Limeira city, State of São Paulo, Brazil

Moraes, Liz Mary Bueno de
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 31/08/2009 PT
Relevância na Pesquisa
37.95%
O objetivo principal deste trabalho foi avaliar a composição química do material particulado em suspensão na atmosfera na cidade de Limeira/SP, pela técnica de fluorescência de raios X dispersiva em energia (EDXRF). Um amostrador tipo stacker foi utilizado para coletar particulados fino (partículas com diâmetro aerodinâmico entre 2,5 e 10 'mü'm) e grosso (partículas maiores que 10 'mü'm), utilizando filtros de policarbmüonato de 47 mm de diâmetro e com diâmetros de poro de 0,4 e 8 'mü'm, respectivamente. As amostras foram coletadas em 2006 (de janeiro a dezembro), 2008 (de janeiro a abril e de julho a dezembro) e 2009 (de janeiro a março). Na excitação da técnica de EDXRF utilizou-se um tubo de Mo com filtro de Fe (análise sob vácuo) para a determinação dos elementos do Al ao Ca, e com filtro de Zr (análise sob ar atmosférico) para determinação do Sc ao Zn e também do Pb. Para a detecção dos raios X utilizou-se um detector semicondutor de Si(Li) acoplado a um analisador multicanal, com um tempo de aquisição de 300 s. Os espectros de raios X foram interpretados através do programa AXIL e a para a quantificação dos elementos químicos fez-se o uso da metodologia dos parâmetros fundamentais. Realizou-se também microanálises nas amostras utilizando-se um microscópio eletrônico de varredura acoplado a um sistema de fluorescência de raios X por dispersão em energia (SEM/EDS) para a caracterização química e morfológica das partículas coletadas no material particulado em suspensão. Determinou-se também a concentração de negro de fumo (black carbon) utilizando a técnica de reflectância. Embora a amostragem não tenha sido suficiente para indicar a contribuição de cada fonte de emissão...

Determinação de elementos químicos inorgânicos em amostras de sangue total humano e de animais de experimentação (hamster dourado e cavalo da raça crioula) pela técnica de fluorescência de raios X(EDXRF); Inorganic elements determination in human and animal whole blood samples by X-ray fluorescence technique (EDXRF)

Redigolo, Marcelo Miyada
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 24/05/2011 PT
Relevância na Pesquisa
27.83%
O sangue é uma suspensão de células contidas num líquido complexo chamado plasma. O termo sangue total refere-se a amostras de sangue com a totalidade de seus constituintes, parte sólida e líquida. Sendo os elementos químicos responsáveis por funções essenciais, como regulação osmótica, frequência cardíaca e contratibilidade, coagulação sanguínea e excitabilidade neuromuscular. A determinação de elementos químicos em fluidos corporais como sangue, soro, plasma, tecido e urina é usada como monitor de parte ou de todo o organismo. Nesse trabalho, utilizou-se a técnica de fluorescência de raios X (EDXRF) para análise de amostras de sangue total humano e animal, hamsters da espécie dourada (Mesocricetus auratus) e cavalos da raça crioula (Equus caballus). Nas amostras de sangue humano, foram determinados intervalos de referência de Na (1788 - 1826 μg g-1), Mg (63 - 75 μg g-1), P (602 - 676 μg g-1), S (1519 - 1718 μg g-1), Cl (2743 - 2867 μg g-1), K (1508 - 1630 μg g-1), Ca (214 - 228 μg g-1), Cu (4 - 6 μg g-1) e Zn (1 - 3 μg g-1). Foram determinados intervalos de referência de Na (1714 - 1819 μg g-1), Mg (51 - 79 μg g-1), P (970 - 1080 μg g-1), S (1231 - 1739 μg g-1), Cl (2775 - 2865 μg g-1)...

Determinação de metais na bacia do rio Piracicaba usando as técnicas de Difusão em Filmes Finos por Gradiente de Concentração (DGT) e Fluorescência de Raios X Dispersiva em Energia (EDXRF) e por Reflexão Total (TXRF); Determination of metals in Piracicaba river basin using Diffusive Gradients in Thin Films, and Energy Dispersive X-ray Fluorescence (EDXRF) and Total Reflection (TXRF) techniques

Almeida, Eduardo de
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 06/09/2011 PT
Relevância na Pesquisa
28.08%
O desenvolvimento e aplicação de métodos analíticos na avaliação das concentrações de metais nas frações dissolvida e lábil na bacia do rio Piracicaba são de relevante importância para o estudo do comportamento químico-ambiental desses metais e para seu monitoramento, devido ao impacto das atividades antropogênicas nessa bacia. A técnica de difusão em filmes finos por gradiente de concentração (DGT, do inglês diffusive gradients in thin-films), é uma promissora ferramenta analítica de amostragem, pois permite pré-concentração, análise temporal, remoção de interferentes, avaliação lábil e amostragem in situ. A quantificação dos metais pelas técnicas de fluorescência de raios X dispersiva em energia por reflexão total (TXRF, total reflection X-ray fluorescence analysis) para amostras líquidas e da fluorescência de raios X dispersiva em energia (EDXRF, energy dispersive X-ray fluorescence) para amostras sólidas, mostram-se interessantes devido ao caráter multielementar, simultâneo e não destrutivo da análise. Neste trabalho avaliou-se a DGT para a determinação de Cr, Mn, Co, Ni, Cu, Zn e Pb em águas naturais, utilizando-se como agente ligante a membrana de celulose P 81 e como meio difusivo...

Três estratégias para análise quantitativa ou qualitativa por espectroscopia de fluorescência de raios-X por energia dispersiva.; Three strategies for quantitative or qualitative analysis by Energy Dispersive X-ray Fluorescence Spectroscopy.

Pinto, Herbert Prince Favero
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 10/07/2013 PT
Relevância na Pesquisa
27.61%
Este trabalho apresenta estratégias para análise quantitativa e semiquantitativa por Espectrometria de Fluorescência por Dispersão de Energia de Raios-X (EDXRF) em três situações típicas: a) materiais homogêneos cujos componentes estejam majoritariamente dentro do campo de detecção da técnica (análise quantitativa), b) materiais homogêneos cujos componentes estejam majoritariamente fora do campo de detecção da técnica (análise quantitativa de elementos minoritários detectados) e, c) materiais heterogêneos em camadas sobrepostas cujos componentes de interesse analítico estejam dentro do campo de detecção da técnica (análise semi-quantitativa de elementos detectados). O trabalho descreve os dois espectrômetros utilizados para as medidas, desenvolvidos no laboratório. Para a determinação das áreas dos picos, foi utilizado principalmente o software PyMCA, desenvolvido pelo CERN. Para a determinação de composições, foram utilizados dois softwares de análise quantitativa que utilizam o método dos Parâmetros Fundamentais. O primeiro é o PyMCA, que efetua de forma integrada o ajuste dos picos e a determinação dos teores. O segundo pertence ao pacote Ara-Lihuen, desenvolvido no próprio laboratório, e obtém teores a partir de áreas dos picos. O trabalho apresenta o desenvolvimento de rotinas do Ara-Lihuen que permitem a verificação de etapas intermediárias de cálculo.; This work presents the strategies for quantitative and semi quantitative analyses by Energy Dispersive X-Ray Fluorescence (EDXRF) in three typical situations: a) homogeneous materials whose components are mainly within the field of detection of the technique (quantitative analysis)...

Paper-based diffusive gradients in thin films technique coupled to energy dispersive X-ray fluorescence spectrometry for the determination of labile Mn, Co, Ni, Cu, Zn and Pb in river water

de Almeida, Eduardo; do Nascimento Filho, Virgilio Franco; Menegario, Amauri Antonio
Fonte: Pergamon-Elsevier B.V. Ltd Publicador: Pergamon-Elsevier B.V. Ltd
Tipo: Artigo de Revista Científica Formato: 70-74
ENG
Relevância na Pesquisa
27.74%
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); The diffusive gradients in thin films (DGT) technique has shown enormous potential for labile metal monitoring in fresh water due to the preconcentration, time-integrated, matrix interference removal and speciation analytical features. In this work, the coupling of energy dispersive X-ray fluorescence (EDXRF) with paper-based DGT devices was evaluated for the direct determination of Mn, Co. Ni, Cu, Zn and Pb in fresh water. The DGT samplers were assembled with cellulose (Whatman 3 MM chromatography paper) as the diffusion layer and a cellulose phosphate ion exchange membrane (Whatman P 81 paper) as the binding agent. The diffusion coefficients of the analytes on 3 MM chromatography paper were calculated by deploying the DGT samplers in synthetic solutions containing 500 mu g L-1 of Mn. Co, Ni, Cu, Zn and Pb (4 L at pH 5.5 and ionic strength at 0.05 mol L-1). After retrieval, the DGT units were disassembled and the P81 papers were dried and analysed by EDXRF directly. The 3 MM chromatographic paper diffusion coefficients of the analytes ranged from 1.67 to 1.87 x 10(-6) cm(2) s(-1). The metal retention and phosphate group homogeneities on the P81 membrane was studied by a spot analysis with a diameter of 1 mm. The proposed approach (DGT-EDXRF coupling) was applied to determine the analytes at five sampling sites (48 h in situ deployment) on the Piracicaba river basin...

Multielemental evaluation of garbage bags by EDXRF

Almeida, Eduardo de; Cavagis, Alexandre D. M.; Menegario, Amauri Antonio; Nascimento Filho, Virgilio Franco
Fonte: Taylor & Francis Ltd Publicador: Taylor & Francis Ltd
Tipo: Artigo de Revista Científica Formato: 1113-1122
ENG
Relevância na Pesquisa
37.74%
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP); Garbage bags have been broadly used for collecting household waste in Brazil and worldwide. Many of these bags are made from recycled polymers, and the presence of harmful elements is a matter of concern. In this study, an energy dispersive X-ray fluorescence (EDXRF) approach for direct analysis of garbage bags is proposed. The concentrations of K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr and Pb were determined in 14 garbage bags of different brands purchased from local markets in Piracicaba, Sao Paulo State, Brazil. The EDXRF technique proved to be an effective technique for multielemental, environmentally friendly and direct garbage bag monitoring. For most samples, Ca and Ti presented at minor concentration ranges and K, Cr, Mn, Fe, Ni, Cu, Zn and Pb at minor and trace levels. The EDXRF limits of quantification were K: 220; Ca: 112; Ti: 42; Cr: 19; Mn: 13; Fe: 9.2; Ni: 5.7; Cu: 5.3; Zn: 5.2; Br: 12; Rb: 20; Sr: 28 and Pb:17 mu gg(-)(1). The samples had variable thicknesses, with a superficial density variation of 1.5 to 23% among the triplicates. The trueness of the method was checked by analysing the National Institute of Standards and Technology standard reference material SRM2783.

Estudo da contaminação ambiental atmosferica e de aguas superficiais, empregando a fluorescencia de raios X dispersiva em energia (EDXRF) e reflexão total (TXRF)

Edson Matsumoto
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 10/01/2001 PT
Relevância na Pesquisa
27.74%
A poluição ambiental é um problema já existente, e não solucionado, nos grandes centros urbanos e que vem se estendendo para outros centros em expansão populacional e industrial. Este crescimento tem criado regiões metropolitanas fora das grandes capitais estaduais. Um desses centros é a cidade de Campinas, SP, onde este estudo foi realizado. Para se obter algumas informações relacionadas com o nível da poluição ambiental de Campinas, foram analisadas amostras de particulado atmosférico e de águas superficiais (chuva e rio). Foi utilizada a técnica analítica da fluorescência de raios X, nas duas variantes, dispersiva em energia (EDXRF), com tubo de raios X, para a análise de água de rio e, reflexão total (TXRF), com radiação síncrotron, para a análise de particulado atmosférico e água de chuva. A análise gravimétrica do material particulado inalável depositado nos filtros, para um período de 24 h de amostragem, mostrou que o limite estabelecido pelo Conselho Nacional do Meio Ambiente (CONAMA), que é de 150 Jlglm3, foi ultrapassado somente em duas ocasiões nas amostras coletadas no posto da região central da cidade de Campinas. Após um tratamento químico adequado, as amostras foram analisadas utilizando a TXRF...

Identification of ancient gilding technology and Late Bronze Age metallurgy by EDXRF, Micro-EDXRF, SEM-EDS and metallographic techniques

Figueiredo, Elin; Silva, Rui J. C.; Araújo, Maria de Fátima; Martinez, João Carlos de Sena
Fonte: Springer-Verlag Publicador: Springer-Verlag
Tipo: Artigo de Revista Científica
Publicado em /01/2010 ENG
Relevância na Pesquisa
27.83%
A combination of analytical techniques capable of elemental and microstructural characterisation was used for the identification of ancient gilding technology and bronze metallurgy. EDXRF, micro-EDXRF, SEM-EDS analysis and metallographic examinations were applied in the study of artefacts dating to the end of the second millennium BC from Crasto de São Romão in Central Portugal. Results report to the finding of an exceptional gilded copper nail among bronze artefacts with 9 wt.% to15 wt.% tin and minute other metallic impurities. Additionally, analysis of a crucible fragment points out for bronze production at the archaeological site. EDXRF and micro-EDXRF analysis made on the copper nail showed that it was gilded only on the front side of the head, and that the gold layer has been lost in the most exposed areas. SEM-EDS analysis showed that the gold layer has 5–8 μm in thickness and is covered with a thick corrosion layer. The gilding technique is discussed based on the gold layer composition and gold/copper substrate interface. So far, this object seems to be the first diffusion gilded artefact identified in the Portuguese territory dated to Late Bronze Age.

Evaluation of EDXRF for the Determination of Elements in PM10 Filter

YATKIN SINAN; GERBOLES Michel; BOROWIAK Annette; TANET Gerard; PEDRONI Valerio; PASSARELLA Rosanna; LAGLER Friedrich
Fonte: Publications Office of the European Union Publicador: Publications Office of the European Union
Tipo: EUR - Scientific and Technical Research Reports Formato: Online
ENG
Relevância na Pesquisa
27.74%
Energy Dispersive X-ray Fluorescence (EDXRF) was compared to Inductively Coupled Plasma Mass Spectrometer (ICP-MS) for the measurements of elements in particulate matter (PM10). Lead (Pb), arsenic (As), nickel (Ni) and cadmium (Cd)) and the ones included in the EMEP programme, namely copper, chromium and zinc were tested. Other elements such as magnesium, aluminium, silicon, sulphur, chloride, potassium, calcium, titanium, vanadium, iron, cobalt, manganese, bromide, strontium, molybdenum, tin and antimony, which are essential for source apportionment studies, were also tested. PM10 samples collected at different sites on several types of filter were analyzed using both EDXRF and ICP-MS. As the overall result of this study, EDXRF can be considered as an alternative method to ICP-MS for measurements of PM-bound elements, particularly on Teflon filters. The European legislative requirements of Pb could be met for whatever filters type. The European legislative requirements of Ni and As are likely be met, but, it is unknown for Cd. The EMEP requirements can be met for Cu and Zn, but not for Cr. EDXRF can also be used to measure elements for source apportionment purposes; JRC.H.2-Climate change and air quality

Evaluation of standardless EDXRF analysis for the determination of elements on PM10 loaded filters

YATKIN SINAN; GERBOLES Michel; BOROWIAK Annette
Fonte: PERGAMON-ELSEVIER SCIENCE LTD Publicador: PERGAMON-ELSEVIER SCIENCE LTD
Tipo: Articles in Journals Formato: Online
ENG
Relevância na Pesquisa
27.99%
Energy Dispersive X-ray Fluorescence (EDXRF) was compared to Inductively Coupled Plasma Mass Spectrometer (ICP-MS) for the measurements of elements (Mg, Al, Si, S, Cl, K, Ca, Ti, V, Cr, Fe, Co, Ni, Mn, Cu, Zn, As, Br, Sr, Pb, Mo, Cd, Sn and Sb) in particulate matter (PM10) collected on Teflon and two types of quartz filters at different sites. Two different calibration methods of EDXRF, linear calibration and standardless analysis, were studied. For the linear calibration, Pb, Mn, Fe, Cu and Zn were found to be site and filter type independent whereas Ca was only site independent. The site effect was evidenced for K, As, Ni, Ti, and V for quartz filter. The standardless EDXRF analysis showed better results than linear calibrations except for As, Co and V for Teflon filters and Cr and V for quartz filters. The estimated measurement uncertainties of standardless EDXRF analysis were calculated. They were found to be equal to or less than those field ones at certain masses for most of the studied elements. This suggests that the model equation to estimate measurement uncertainty of standardless EDXRF analysis covers all the uncertainty sources for certain elemental masses. It was found that standardless EDXRF analysis is able to quantify most of the elements studied...

Investigation of the mass loss of water soluble ionic compounds caused by EDXRF analysis of PM 10 loaded filters

YATKIN Sinan; GERBOLES Michel
Fonte: PERGAMON-ELSEVIER SCIENCE LTD Publicador: PERGAMON-ELSEVIER SCIENCE LTD
Tipo: Articles in Journals Formato: Online
ENG
Relevância na Pesquisa
27.83%
The PM mass loss due to EDXRF analysis of PM 10 loaded filters was investigated in this study. The mass loss was gravimetrically evaluated on collocated filters analyzed both by EDXRF under vacuum condition and by Ion Chromatography. Then, this comparison was repeated with a gaseous mixture of air and Helium (He) instead of evacuating the measurements chamber of the EDXRF spectrometer. It was shown that EDXRF analysis under vacuum medium leads to mass loss of water soluble ions and other volatile constituents of PM 10 . The total PM mass loss was found not to be limited to water soluble ionic species, indicating that other volatile components of PM were likely to be lost. The use of a He and air mixture medium considerably reduced the PM mass losses. As the conclusion of the first step of this study, the mass loss of PM and ions mainly resulted from vacuum medium and to a lower extent to the level of x-Ray energy. In the second part of the study, the influence of EDXRF analysis using vacuum medium on the mass losses of ions were individually investigated. It was revealed that different amounts of NO 3 , NH 4 , Cl, Na, Mg and Ca were lost whereas SO 4 and K remained unchanged. At the last step of the study...

Análise arqueométrica de cerâmica Tupiguarani da região central do Estado do Rio Grande do Sul, Brasil, usando fluorescência de raios X por dispersão de energia (EDXRF)

Bona,Irene Akemy Tomiyoshi; Sarkis,Jorge Eduardo S.; Salvador,Vera Lucia Ribeiro; Soares,André Luis Ramos; Klamt,Sergio Célio
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/08/2007 PT
Relevância na Pesquisa
37.42%
Energy dispersive X-ray fluorescence methodology (EDXRF) was used to determine Al, Ba, Ca, Cr, Fe, K, Mn, Pb, Rb, S, Si, Sr, Ti, V, Zn in pottery sherds from seven archaeological sites in the central region of Rio Grande do Sul State, Brazil. The potteries' chemical fingerprints from Ijuí River, Ibicuí Mirim River, Vacacaí Mirim River and Jacuí River were identified. Interactions between sites from the Jacuí River, Vacacaí Mirim River and Ibicui Mirim River could have occurred because some samples from these sites are overlapping in a principal component analysis (PCA) graphic. The pottery provenance could be the same.

Caracterização de pinturas do artista Alfredo Volpi por meio de métodos não destrutivos: espectrofotômetro, EDXRF, MEV e imageamento multiespectral; Characterization of the artist Alfredo Volpi\'s paintings by non-destructiva methods: spectrophotometer, EDXRF, SEM and multispectral imaging

Mori, Eva Kaiser
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 02/09/2015 PT
Relevância na Pesquisa
37.83%
Alfredo Volpi (1896 - 1988) é um dos mais importantes pintores brasileiros contemporâneos. Sua extensa obra foi marcada, principalmente, por composições cromáticas e abstrações geométricas. Foi um artista que dava importância muito grande à técnica e aos materiais, tendo desenvolvido uma maneira própria e sistemática de trabalhar: confeccionava suas próprias telas, tintas e até pigmentos, com terras naturais. Analisou-se ao todo 11 pinturas a têmpera em diversos suportes (tela, aglomerado de madeira e mural), 10 delas realizadas na década de 1950, período em que a obra do artista passou por uma grande transformação, do figurativismo ao abstracionismo e do uso de tintas industriais à base de óleo para a técnica medieval da têmpera. As características de opacidade, saturação cromática e presença material do pigmento sobre a superfície da tela, inerentes a esta técnica pictórica, tornam-se elementos tão importantes em sua obra, quanto o uso da cor na formação do espaço. Foram realizados estudos de cor e composição química dos materiais e levantamentos de informações sobre seus procedimentos técnico-artísticos a partir de métodos analíticos complementares não destrutivos e pesquisa em diversas fontes...

Elemental analysis of mining wastes by energy dispersive X-ray fluorescence (EDXRF)

González-Fernández, Oscar; Queralt Mitjans, Ignacio; Carvalho, M.L.; García, G.
Fonte: Elsevier Publicador: Elsevier
Tipo: Artículo Formato: 210620 bytes; application/pdf
ENG
Relevância na Pesquisa
37.42%
An energy dispersive X-ray fluorescence (EDXRF) tri-axial geometry experimental spectrometer has been employed to determine the concentrations of 13 different elements (K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Rb, Sr and Pb) in mine wastes from different depths of two mine tailings from the Cartagena-La Union (Spain) mining district. The elements were determined and quantified using the fundamental parameters method. The concentrations of Cr, Ni, Cu, Zn and Pb were compared to the values from the European and Spanish legislation to evaluate the environmental risk and to classify the wastes as inert wastes or as wastes that have to be control land-filled. The results obtained demonstrate that these wastes can be considered as inert for the considered elements, apart from the concentration levels of Zn and Pb. Whilst Zn slightly overpasses the regulatory levels, Pb mean value exceeds three to six times the value to be considered as Class I potential land-filling material.; This research was made on the framework of the project CGL2004-05963-C04 of the Spanish National Research Programme. Also Oscar Gonzalez Fernandez acknowledges a grant from the Spanish Government (BES-2005-6810).; Peer reviewed

Spectroscopic analytical methodologies for the study of cultural heritage materials

Pitarch i Martí, Àfrica
Fonte: [Barcelona] : Universitat Autònoma de Barcelona, Publicador: [Barcelona] : Universitat Autònoma de Barcelona,
Tipo: Tesis i dissertacions electròniques; info:eu-repo/semantics/doctoralThesis; info:eu-repo/semantics/publishedVersion Formato: application/pdf
Publicado em //2015 ENG
Relevância na Pesquisa
28.11%
Els estudis que es presenten en aquesta tesi doctoral se centren en l'aplicació i millora de metodologies analítiques existents, relativament senzilles, i el desenvolupament de nous procediments que poden utilitzar-se per a l'estudi de materials del Patrimoni Cultural. La posada en pràctica i la modelització de la resposta analítica de les tècniques espectroscòpiques utilitzades en aquest treball s'ha dut a terme mitjançant l'anàlisi de materials antics de diferent tipus, començant amb materials de composició relativament senzilla com ara aliatges metàl·lics i passant, gradualment, a l'estudi de materials amb matrius més complexes tals com pigments minerals, papers i tintes. Els resultats obtinguts són de notable interès per a la conservació d'aquests materials, aspecte rellevant donada la seva fragilitat i elevat potencial d'alterabilitat. En aquest sentit, en primer lloc es va fer un estudi exhaustiu de monedes antigues de diversa cronologia, mitjançant l'ús de la fluorescència de raigs X per dispersió d'energies (EDXRF). Els resultats de les anàlisis van permetre determinar no només la composició química elemental de les monedes i donar resposta a algunes de les qüestions plantejades pels historiadors, sinó que també van permetre optimitzar al màxim les condicions experimentals de les anàlisis i fixar els límits de quantificació per aquest tipus de matrius. En segon lloc...