Página 1 dos resultados de 205 itens digitais encontrados em 0.016 segundos

A Survey of Fungal Contamination on Books in Public Libraries with Mechanical and Natural Ventilation

REIS-MENEZES, Adriana Araujo; GAMBALE, Walderez; GIUDICE, Mauro Cintra
Fonte: SAGE PUBLICATIONS LTD Publicador: SAGE PUBLICATIONS LTD
Tipo: Artigo de Revista Científica
ENG
Relevância na Pesquisa
46.13%
Libraries are very propitious environments for the growth of fungi. The great concentration of organic material available for these microorganisms, and often with the lack of adequate ventilation or climate control, would favour this situation. This study was conducted in 2003 to determine the predominant genera of fungi in public libraries by a survey of fungi contaminating the upper surface of books, with and without air conditioning in the city of Sao Paulo, Brazil, in the winter and summer, during the respective periods with high and low levels of airborne fungi in that city. Six libraries were chosen, located on the campus of the University of Sao Paulo, three of them with air conditioning and the other three with natural ventilation. In these six libraries, 31 genera of fungi were identified in total. The genera and frequency of contaminant fungi recovered differed significantly between the libraries with and without air conditioning and in the samples collected in the summer as opposed to the winter. Cladosporium was the most frequent in the libraries with and without air conditioning, and in the winter. Aspergillus was isolated more often in the summer.; CAPES - Brazilian Ministry of Education; Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Sistema de ar condicionado com insuflamento pelo piso em ambientes de escritórios: avaliação do conforto térmico e condições de operação.; Underfloor air supply system applied to office buildings: thermal comfort and operational conditions evaluation.

Leite, Brenda Chaves Coelho
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 06/03/2003 PT
Relevância na Pesquisa
56.17%
Desde a introdução do conceito de escritório aberto, o tipo de ocupação e a distribuição das cargas internas têm sofrido grandes mudanças, requerendo maior flexibilidade nos edifícios. Além disto, avaliações de desempenho de edifícios de escritórios da atualidade têm apresentado resultados que são fortes indicadores da necessidade de mudanças de conceitos de projeto, operação e uso de sistemas de condicionamento de ar, devido ao elevado nível de insatisfação dos usuários quanto ao conforto e à qualidade do ar. Para tentar solucionar estes problemas, outro conceito em distribuição de ar, já em uso nos países desenvolvidos, está começando a ser adotado também no Brasil; trata-se de insuflamento pelo piso, com difusores instalados em placas de piso elevado e nas estações de trabalho, que permitem flexibilidade e controle individual de vazão de ar. Neste trabalho foi feita a avaliação de sistema de condicionamento de ar com insuflamento pelo piso em um laboratório com condições controladas. O laboratório em que foram realizados os ensaios foi projetado e instalado com características similares àquelas de ambientes reais de edifícios de escritórios. Este fato, aliado à participação de usuários no processo de avaliação das condições de conforto térmico...

Determinação de índices de ajuste no controle de sistema de condicionamento de ar do tipo 'teto frio'.; Determination of adjustment indexes in control of "cooling ceiling" air conditioning system.

Ikeda, Marcelo Jun
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 14/05/2008 PT
Relevância na Pesquisa
66.21%
O presente trabalho é um estudo para a determinação de índices de ajuste em medidas efetuadas por sensores de temperatura do ar utilizadas em algoritmos de controle do sistema de automação do sistema de condicionamento de ar do tipo "Teto Frio". É um trabalho experimental baseado na coleta de dados de diversas variáveis ambientais em um laboratório que utiliza este tipo de sistema. Esse laboratório possui um sistema de climatização misto composto por circuitos de água gelada que percorre serpentinas instaladas em placas metálicas de forro, para troca de calor por radiação (retirada de calor sensível) e circuitos de ar, com distribuição de ar pelo teto, para troca de calor por convecção (retirada de calor latente). Seu funcionamento é controlado por um sistema de automação (hardware e software) específico. Este estudo pretende determinar índices de ajuste que, introduzidos nos algoritmos de controle do sistema de automação, corrijam as leituras de temperatura do ar realizadas no ambiente por sensores do sistema posicionados em locais que, embora esteticamente sejam os mais adequados, funcionalmente, não o são. Os resultados, concluídos através de método estatístico e recursos de representação gráfica...

Medição, predição e análise de partículas aéreas em salas cirúrgicas.; Measurement, prediction and analysis of airborne particles in surgical rooms.

Pereira, Marcelo Luiz
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 10/10/2008 PT
Relevância na Pesquisa
46.13%
Os sistemas de condicionamento de ar exercem função importante em uma sala cirúrgica, que é proteger a ferida cirúrgica e os equipamentos estéreis dos microrganismos carreados pelo ar. Essa proteção é feita pelo controle simultâneo da movimentação e distribuição do ar, da temperatura, da umidade, da filtragem, das infiltrações de ar de outros setores, entre outros. Esses são fatores que afetam diretamente a quantidade de partículas aéreas presentes em uma sala cirúrgica. Dentro deste contexto, no presente trabalho foi desenvolvido um modelo matemático para predição da concentração de partículas em salas cirúrgicas e para determinação da importância relativa dos fatores que interferem na geração e remoção dessas partículas. O modelo proposto baseia-se no balanço de massa para o cálculo da concentração de partículas, que foi aplicado e validado com os dados obtidos em salas cirúrgicas com diferentes tipos de sistemas de condicionamento de ar. Nessas salas cirúrgicas foram realizadas medições de variáveis ambientais considerando diferentes situações que normalmente ocorrem na rotina de salas cirúrgicas. Para cada uma das condições analisadas, é proposto um determinado conjunto de parâmetros relativos ao ambiente...

Modelagem de sistema de controle de ar condicionado baseado em redes de Petri.; Air conditioning control systems modelling using Petri nets.

Almeida, Antonio Gabriel Souza
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 16/10/2008 PT
Relevância na Pesquisa
76.21%
Dentre as tendências de uso racional de recursos, principalmente energia, e da necessidade de assegurar a produtividade e qualidade na execução de atividades produtivas, destaca-se o conceito de edifício inteligente. Este ambiente materializa o conceito de integração dos sistemas prediais potencializando a otimização dos recursos e a eficiência do trabalho humano. Neste contexto, abordagens conceituais baseadas em sistemas a eventos discretos e técnicas derivadas de rede de Petri têm sido introduzidas como uma alternativa eficaz de modelagem e análise das soluções de integração dos sistemas prediais. Um resultado expressivo destas iniciativas são os métodos propostos para a modelagem e análise de estratégias de gerenciamento de sistemas de ar condicionado, utilizando uma abordagem híbrida, onde são considerados os aspectos de sistemas a eventos discretos e as variáveis de dinâmica contínua. Contudo, as abordagens e métodos existentes são limitados a soluções específicas de implementação, como os sistemas de ar condicionado com volume de ar contínuo. Assim, o presente trabalho introduz uma extensão destas abordagens para modelar e analisar soluções de automação predial que incluem sistemas de ar condicionado com volume de ar variável. A eficiência deste método na concepção e validação destas soluções é ilustrada através de um estudo de caso.; Among the trends of rational use of resources...

Detecção de bactérias do gênero Legionella em amostras de água provenientes de sistemas de ar condicionado; Detection of bacteria genus Legionella in water samples of airconditioning systems [master degree]

Etto, Helder Yudji
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 16/06/2009 PT
Relevância na Pesquisa
46.13%
Introdução: Destaca-se a importância dos organismos do gênero Legionella como agentes causadores de doenças do aparelho respiratório como a legionelose ou doença do Legionário, e ainda de um controle na manutenção adequada de sistemas de ar condicionado, uma vez que estes foram identificados como ambientes favoráveis à proliferação desses microrganismos. Objetivo: Devido à importância de bactérias do gênero Legionella como agentes causadores de doenças, e um crescente número de casos de legionelose relacionados à permanência em ambientes fechados, este estudo teve como objetivo determinar a presença de Legionella em águas de bandejas de sistemas de ar condicionado. Métodos: Foram realizadas análises de amostras de água provenientes de bandejas de ar condicionado de dois hospitais, uma instituição de ensino superior e um centro comercial, totalizando 41 amostras. Volumes de 1L das amostras coletadas foram concentrados em membrana, seguida de tratamento ácido. Alíquotas das amostras tratadas e não tratadas com ácido, foram então inoculadas em meio Agar BCYE-, com e sem adição de antibióticos. As cepas isoladas foram submetidas a teste sorológico para identificação. Resultados: Das amostras analisadas...

Eficiência energética em edifícios hospitalares obtida por meio de estratégias passivas: estudo da redução do consumo com climatização para arrefecimento do ar em salas de cirurgia; Energy efficiency in hospital buildings achieved through passive strategies: a study of reduced consumption with air conditioning for air-cooling in operating rooms.

Campos, Clarissa Cordeiro de
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 03/04/2013 PT
Relevância na Pesquisa
46.12%
A pesquisa propõe avaliar quantitativamente a eficácia do emprego de estratégias passivas em um bloco cirúrgico hospitalar para a redução do consumo de energia elétrica com fins de arrefecimento do ar. A partir do estudo da conformação histórica do edifício hospitalar e da identificação das unidades funcionais em que é obrigatório o uso de ar condicionado; das características de geração e consumo de energia elétrica no Brasil e potenciais de economia energética em edificações, com foco em hospitais; seguidos do estabelecimento de conceitos básicos de térmica de edificações, estabeleceu-se o embasamento teórico para a realização de estudos de caso na cidade de Belo Horizonte, Minas Gerais. A análise comparativa dos dados de área física, sistemas de iluminação artificial, climatização e equipamentos coletados em seis blocos cirúrgicos possibilitou a seleção de uma unidade para construção de modelo computacional e realização de simulações em software de análise de desempenho térmico e energético de edificações. Os resultados alcançados demonstraram a importância de se considerar as condições bioclimáticas locais, em especial o controle da insolação direta, bem como reforçaram a concepção de que o projeto arquitetônico pode contribuir para a eficiência energética da edificação...

Conforto térmico e concentração de CO2 em salas de cirurgias e salas de espera para pacientes, climatizadas artificialmente.; Thermal comfort and CO2 concentration in air conditioned operating rooms and waiting rooms for patients.

Santana, Elaine Gonçalves Ferreira
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 19/04/2013 PT
Relevância na Pesquisa
46.1%
Nos últimos anos tem havido um aumento no estudo da qualidade do ar interno relacionado aos sistemas de ventilação mecânica e condicionamento do ar. Isso é especialmente fundamental em hospitais, onde a transmissão da contaminação pelo ar é considerada uma das principais causas de aquisição de doenças por pacientes, profissionais de saúde e visitantes. Além disso, essas instituições por abrigarem diversos setores, cada um com uma especificidade e função, exigem diferentes condições de conforto ambiental, sob os aspectos higrotérmico e de qualidade do ar, além do acústico e luminoso. Com o objetivo de avaliar a qualidade o ar, sob os parâmetros de conforto térmico e da concentração de dióxido de carbono em ambientes hospitalares climatizados artificialmente, realizou-se uma investigação de campo em salas de espera e salas de cirurgias de uma amostra de seis edifícios hospitalares na cidade de São Paulo e região metropolitana. Para coleta dos dados foram utilizados instrumentos de monitoramento, portáteis e de elevada precisão, adequados para a realização da pesquisa. Os resultados obtidos a partir da análise desses dados apontaram relevantes problemas relacionados ao conforto e a qualidade do ar. Dentre esses problemas...

The role of allergic rhinitis in nasal responses to sudden temperature changes

Graudenz, Gustavo Silveira; Landgraf, Richardt G.; Jancar, Sonia; Tribess, Arlindo; Fonseca, Simone G.; Fae, Kellen Cristhina; Kalil, Jorge
Fonte: Elsevier B.V. Publicador: Elsevier B.V.
Tipo: Artigo de Revista Científica Formato: 1126-1132
ENG
Relevância na Pesquisa
46.13%
Background: Air conditioning-induced rhinitis in allergic individuals is a common epidemiologic finding, but its physiopathology,is still controversial. The aim of this study was to describe and compare the effects of experimental air conditioning temperature changes on the nasal mucosa of individuals with persistent allergic rhinitis compared with a control group.Methods: A case-control challenge study was performed in a laboratory of thermal comfort with experimental twin challenge chambers set at a 12 C difference in temperature. A group of 32 patients with persistent allergic rhinitis and a group of 16 control subjects were exposed for 30 minutes, 3 times alternately in each chamber. Nasal symptom scores were recorded and nasal samples collected before, immediately after, and 24 and 48 hours after the challenge.Results: the rhinitis group showed a higher symptom score, epithelial shedding, percentage of eosinophils, total inflammatory cells, leukotriene C-4, eosinophil cationic protein, albumin, and tryptase levels compared with controls. There was also a significant increase in symptom score, total cells recovered, percentage of eosinophils, epithelial shedding, albumin, myeloperoxidase, and soluble intercellular adhesion molecule 1 in both groups compared with baseline levels.Conclusion: Sudden temperature changes led to a more pronounced inflammatory nasal response in the rhinitis group with the recruitment and activation of eosinophils.Clinical implications: Persistent allergic rhinitis is a risk factor for developing sudden temperature change-related rhinitis even in the absence of allergen exposure.

Experimental research on the influence of the air humidity conditions in an air conditioning system

Sobrinho, Pedro Magalhães; Tuna, Celso Eduardo
Fonte: Universidade Estadual Paulista Publicador: Universidade Estadual Paulista
Tipo: Artigo de Revista Científica Formato: 152-159
ENG
Relevância na Pesquisa
66.08%
The factors that have influence on the energy consumption of a small air conditioning system that are worth mentioning are the efficiencies of the compressor, evaporator and condenser, the form that the refrigerant flow is controlled, the fan model used, and climatic conditions. Within the climate issue, an interesting factor is that the relative humidity when it comes to the effect that it causes, especially in the performance of the air condenser, which generally is not considered in the projects. This study aims to evaluate the influence of humidity on the coefficient of system performance (COP), seeking to quantify their influence when it happens. The tests were performed on a testing bench, mounted at the Laboratory for Energy Efficiency (LAMOTRIZ) UNESP-Campus Guaratinguetá. In the study, the wet bulb temperature was ranged, keeping the rotation of the scroll compressor with application of a frequency inverter in its best performance. The test bench is provided with a supervisory system of data collection that is also able to control all functions of the bench. In the results, there was a significant influence, particularly when comparing high humidity conditions with low humidity, noting that only over 65% relative humidity is that significant changes are observed in the COP of the system. © 2013 Elsevier Inc.

Implementação de uma bancada de ensaios para analise de estrategias de controle de sistemas de refrigeração e ar condicionado; Conditioned air system control analysis with termical storage in a ice storage

Fabio Alejandro Carvajal Florez
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 27/02/2004 PT
Relevância na Pesquisa
66.05%
No presente trabalho se realiza o estudo do controle da válvula de expansão e da velocidade de rotação do motor do compressor para um sistema de ar condicionado com armazenamento térmico em banco de gelo. Utilizando os princípios de projeto térmico, projeto eletrônico, programação de computadores e técnicas de controle procuram-se o aumento da eficiência do sistema. Neste controle propostos usou-se a lógica difusa. Inicialmente controlou-se o grau de superaquecimento através do controle da abertura da válvula de expansão e trabalhando o compressor em sua rotação máxima. Em seguida foi implementado um controle que trabalha regulando simultaneamente a velocidade do compressor e a abertura da válvula de expansão; In this work is realized a control analysis ofthe expansion valve and the rotacional speed of the compressor engine for an air conditioning system with thermal storage in an ice storage tank. The thermal project, electronical project, computer programming and control technics are integrated to increase the performance of the system. To implement the proposed controls the logic fuzzy is used. Inicially, the refrigerant superheat was controlled through the expansion valve with the compressor working at highest rotational speed. Then...

Acaroid mite allergens from the filters of air-conditioning system in China

Li, Chao-Pin; Guo, Wei; Zhan, Xiao-Dong; Zhao, Bei-Bei; Diao, Ji-Dong; Li, Na; He, Lian-Ping
Fonte: e-Century Publishing Corporation Publicador: e-Century Publishing Corporation
Tipo: Artigo de Revista Científica
Publicado em 15/06/2014 EN
Relevância na Pesquisa
46.13%
Accumulation of acaroid mites in the filters of air-conditioners is harmful to human health. It is important to clarify the allergen components of mites from the filters of local air-conditioning system. The present study was to detect the allergen types in the filters of air-conditioners and assesse their allergenicity by asthmatic models. Sixty aliquots of dust samples were collected from air conditioning filters in civil houses in Wuhu area. Total protein was extracted from the dust samples using PBS and quantified by Bradford method. Allergens I and II were also detected by Western blot using primary antibody (anti-Der f1/2, Der p1/Der f2/Der p2, respectively). Ten aliquots of the positive samples were randomly selected for homogenization and sensitized the mice for developing asthmatic animal models. Total serum IgE level and IFN-γ, IL-4 and IL-5 in the bronchoalveolar lavage fluid (BALF). The allergenicity of the extraction was assessed using pathological sections developed from the mouse pulmonary tissues. The concentration of extract from the 60 samples was ranged from 4.37 μg/ml to 30.76 μg/ml. After analyzing with Western blot, 31 of 60 samples were positive for 4 allergens of acaroid mites, and yet 16 were negative. The levels of total IgE from serum IL-4 and IL-5 from the BALF in the experimental group were apparently higher than that of negative control and PBS group (P < 0.01)...

Modeling Validation and Control Analysis for Controlled Temperature and Humidity of Air Conditioning System

Lee, Jing-Nang; Lin, Tsung-Min; Chen, Chien-Chih
Fonte: Hindawi Publishing Corporation Publicador: Hindawi Publishing Corporation
Tipo: Artigo de Revista Científica
EN
Relevância na Pesquisa
46.19%
This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for controlling the air mass flow rate, humidifying capacity, and heating, capacity. The simulation results show that the temperature and humidity are stable at 541 sec, the disturbance of temperature is only 0.14°C, 0006 kgw/kgda in steady-state error of humidity ratio, and the error rate is only 7.5%. The results prove that the proposed system is an effective controlled temperature and humidity of an air conditioning system.

Solar energy dehumidification experiment on the Citicorp Center building : final report

Fonte: MIT Energy Laboratory Publicador: MIT Energy Laboratory
Tipo: Relatório Formato: 9053484 bytes; application/pdf
EN_US
Relevância na Pesquisa
56.01%
The technical and economic feasibility of using solar energy to reduce conventional energy consumption of a large urban commercial building were studied in depth. Specifically, solar assisted dehumidification of ventillation air to reduce conventional air conditioning requirements for the Citicorp Center in New York City was investigated. A detailed computer simulation of yearly operation was made on an hourly basis using New York City temperature, humidity and solar data. Several system configurations were examined and were defined each operating in its most efficient fashion. It was found that maximum energy savings was achieved by optimizing the operation of the conventional system. Maximum energy savings could be achieved by the following, in order of decreasing impact: optimization of the operation of the conventional system, use of additional conventional equipment for energy savings, and use of the solar assisted system.; NSF/RA-760003 Prepared for National Science Foundation, RANN/Research Applied to National Needs under Grant no. PTP-75-05156

Intelligent energy management control of vehicle air conditioning via look-ahead system

Khayyam, H.; Nahavandi, S.; Hu, E.; Kouzani, A.; Chonka, A.; Abawajy, J.; Marano, V.; Davis, S.
Fonte: Pergamon-Elsevier Science Ltd Publicador: Pergamon-Elsevier Science Ltd
Tipo: Artigo de Revista Científica
Publicado em //2011 EN
Relevância na Pesquisa
46.1%
http://www.sciencedirect.com/science/journal/13594311; Hamid Khayyam, Saeid Nahavandi, Eric Hu, Abbas Kouzani, Ashley Chonka, Jemal Abawajy, Vincenzo Marano and Sam Davis

Sustainable and Smart Cities

Kahn, Matthew E.
Fonte: World Bank, Washington, DC Publicador: World Bank, Washington, DC
Tipo: Publications & Research :: Policy Research Working Paper; Publications & Research
ENGLISH; EN_US
Relevância na Pesquisa
46.07%
This paper explores the challenges and opportunities that government officials face in designing coherent 'rules of the game' for achieving urban sustainability during times of growth. Sustainability is judged by three criteria. The first involves elements of day-to-day quality of life, such as having clean air and water and green space. The provision of these public goods has direct effects on the urban public's health and productivity. The second focuses on the city's greenhouse gas emissions. Developing cities are investing in new infrastructure, from highways and public transit systems to electricity generation and transmission. They are building water treatment, water delivery, and sewage disposal systems. Residents of these cities are simultaneously making key decisions about where they live and work and whether to buy such energy-consuming durables as private vehicles and home air-conditioning units. Given the long-lived durability of the capital stock, short-term decisions will have long-term effects on the city's carbon footprint. The third criterion is a city's resilience to natural disasters and extreme weather events. This subsection focuses on how the urban poor can be better equipped to adapt to the anticipated challenges of climate change.

Mexico - Low-Carbon Development : Main Report; Mexico - Estudio sobre la disminución de emisiones de carbono

World Bank
Fonte: World Bank Publicador: World Bank
Tipo: Economic & Sector Work :: Other Environmental Study
ENGLISH
Relevância na Pesquisa
46.05%
This study analyzes a range of energy efficiency options available in Mexico, including supply-side efficiency improvements in the electric power and oil and gas industries and demand-side electricity efficiency measures to limit high-growth energy-consuming activities, such as air conditioning and refrigeration. It also evaluates a range of renewable energy options that make use of the country's vast wind, solar, biomass, hydro, and geothermal resources. But low-carbon (CO2) development is not only about energy production and consumption. In Mexico one of the most important sources of greenhouse gas emissions continues to be emissions from deforestation. The rate of deforestation has fallen steadily in Mexico over the past decades. Expanded programs for forest management, wildlife conservation, and efforts to increase the stock of forests can provide needed employment in rural areas and help make Mexican forests net absorbers of CO2 in the coming years. A fundamental question often asked about low-cost mitigation options is why they are not already being undertaken. As the study shows...

Low-Carbon Development for Mexico; Mexico - Estudio sobre la disminucion de emisiones de carbono

Johnson, Todd M.; Alatorre, Claudio; Romo, Zayra; Liu, Feng
Fonte: World Bank Publicador: World Bank
Tipo: Publications & Research :: Publication; Publications & Research :: Publication
ENGLISH
Relevância na Pesquisa
46.05%
One of the most compelling reasons for pursuing low-carbon development is that the potential impacts of climate change are predicted to be severe, for both industrial and developing countries, and that reducing greenhouse gas emissions can reduce the risk of the most catastrophic impacts. The challenge of reducing emissions is sobering: leading scientific models indicate that limiting the rise in global mean temperatures to less than two degree Celsius will require that global greenhouse gas emissions peak within the next 10-15 years and then fall by 2050 to levels about 50 percent lower than in 1990. Although many countries recognize the need to curtail carbon emissions, there is considerable uncertainty about how much this will cost in individual countries, what measures can be undertaken in both the short and longer term, and how cost-effective specific interventions are in reducing emissions. This study analyzes a range of energy efficiency options available in Mexico, including supply-side efficiency improvements in the electric power and oil and gas industries...

Sustainable and Smart Cities

Kahn, Matthew E.
Fonte: World Bank, Washington, DC Publicador: World Bank, Washington, DC
Tipo: Publications & Research :: Working Paper; Publications & Research
ENGLISH; EN_US
Relevância na Pesquisa
46.07%
This paper explores the challenges and opportunities that government officials face in designing coherent 'rules of the game' for achieving urban sustainability during times of growth. Sustainability is judged by three criteria. The first involves elements of day-to-day quality of life, such as having clean air and water and green space. The provision of these public goods has direct effects on the urban public's health and productivity. The second focuses on the city's greenhouse gas emissions. Developing cities are investing in new infrastructure, from highways and public transit systems to electricity generation and transmission. They are building water treatment, water delivery, and sewage disposal systems. Residents of these cities are simultaneously making key decisions about where they live and work and whether to buy such energy-consuming durables as private vehicles and home air-conditioning units. Given the long-lived durability of the capital stock, short-term decisions will have long-term effects on the city's carbon footprint. The third criterion is a city's resilience to natural disasters and extreme weather events. This subsection focuses on how the urban poor can be better equipped to adapt to the anticipated challenges of climate change.

Smart Sensors Enable Smart Air Conditioning Control

Cheng, Chin-Chi; Lee, Dasheng
Fonte: MDPI Publicador: MDPI
Tipo: Artigo de Revista Científica
Publicado em 24/06/2014 EN
Relevância na Pesquisa
66.13%
In this study, mobile phones, wearable devices, temperature and human motion detectors are integrated as smart sensors for enabling smart air conditioning control. Smart sensors obtain feedback, especially occupants' information, from mobile phones and wearable devices placed on human body. The information can be used to adjust air conditioners in advance according to humans' intentions, in so-called intention causing control. Experimental results show that the indoor temperature can be controlled accurately with errors of less than ±0.1 °C. Rapid cool down can be achieved within 2 min to the optimized indoor capacity after occupants enter a room. It's also noted that within two-hour operation the total compressor output of the smart air conditioner is 48.4% less than that of the one using On-Off control. The smart air conditioner with wearable devices could detect the human temperature and activity during sleep to determine the sleeping state and adjusting the sleeping function flexibly. The sleeping function optimized by the smart air conditioner with wearable devices could reduce the energy consumption up to 46.9% and keep the human health. The presented smart air conditioner could provide a comfortable environment and achieve the goals of energy conservation and environmental protection.