Página 2 dos resultados de 45 itens digitais encontrados em 0.000 segundos

Sugestão de valores de referência de qualidade para os elementos químicos cobalto, estanho, fósforo, lítio, molibdênio, níquel, prata, tálio, titânio e vanádio em amostras de água subterrânea coletadas nos Aquíferos Bauru e Guarani, confo; Suggestion of Reference Quality Values for the chemical elements cobalt, tin, phosphorus, lithium, molybdenum, nickel, silver, thallium, titanium and vanadium in groundwater samples collected from Bauru and Guarani Aquifer according to 396 CONAMA Resolution

Savazzi, Eduardo Angelino
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 17/10/2013 PT
Relevância na Pesquisa
16.72%
Os metais são encontrados em todos os organismos vivos, sendo responsáveis por diversas funções e suas deficiências podem comprometer diversas funções biológicas, Mas, quando presentes em concentrações excessivas podem causar efeitos deletérios, modificando uma população ou um conjunto de espécies dentro de um ecossistema. O aquífero Bauru é predominantemente freático e grande parte do aquífero Guarani estudado neste trabalho localiza-se na sua faixa aflorante. Portanto apresentam vulnerabilidade alta, mostrando-se expostos ao risco de degradação antropogênicas, seja por atividades agrícolas ou uso do solo sem critérios em relação as suas aptidões. Os objetivos desse trabalho foram a validação da técnica de análise dos elementos químicos cobalto, estanho, fósforo, lítio, molibdênio, níquel, prata, tálio, titânio e vanádio por espectrometria de emissão atômica com plasma (ICP-OES) com nebulizador ultrassônico acoplado, avaliação da presença desses elementos em amostras coletadas nos aquíferos Bauru e Guarani, visando propor valores de referência para os elementos em estudo. Foram avaliados 57 e 34 pontos de coleta, respectivamente nos aquíferos Bauru e Guarani, em 88 municípios no Estado de São Paulo...

Efeito da intervenção educativa sobre a técnica de administração de medicamentos inalatorios por profissionais de enfermagem

Maciel, Paola Panazzolo
Fonte: Universidade Federal do Rio Grande do Sul Publicador: Universidade Federal do Rio Grande do Sul
Tipo: Trabalho de Conclusão de Curso Formato: application/pdf
POR
Relevância na Pesquisa
16.72%
Introdução: O controle dos sintomas e a prevenção de exacerbações de doenças respiratórias se baseiam no uso de broncodilatadores e corticóides administrados pela via inalátoria. Os dispositivos inalatórios mais utilizados são o nebulizador e o nebulímetro dosimetrado (ND) podendo ser acoplado, ou não, a um espaçador. Evidências da literatura afirmam que profissionais administram o medicamento de forma inadequada. A hipótese do presente estudo é que uma intervenção educativa através de aulas teórico - práticas sobre a técnica inalatória de ND aos profissionais de enfermagem proporcionam uma técnica de administração de medicamento superior àqueles que não receberam treinamento. Objetivo: Avaliar o efeito da intervenção educativa, treinamento, na técnica de administração de medicamentos inalatórios por profissionais de enfermagem. Método:Trata- se de um estudo quantitativo, com desenho quase-experimental. Utilizou-se para comparar o conhecimento entre os grupos, treinados e não treinados, uma avaliação teórico contendo 5 questões fechadas e duas avaliações práticas da administração da técnica para ND com e sem aerocâmara, através de um escore padronizado com 10 itens para cada simulação. Resultados: Participaram 50 profissionais de enfermagem...

Comparação metodológica para determinação empírica de enxofre em fertilizantes minerais

Dalla Vechia, Jacqueline
Fonte: Universidade Federal do Rio Grande do Sul Publicador: Universidade Federal do Rio Grande do Sul
Tipo: Trabalho de Conclusão de Curso Formato: application/pdf
POR
Relevância na Pesquisa
16.72%
Neste trabalho foram comparados três métodos para determinação de enxofre em fertilizantes minerais. Dentre as metodologias aplicadas, encontram-se o método gravimétrico por peróxido de hidrogênio, o método por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e o método turbidimétrico com sistema de injeção em fluxo. Utilizou-se extração com hidróxido de potássio e peróxido de hidrogênio para permitir a determinação do enxofre em suas diversas formas, inclusive elementar. No método gravimétrico, foi realizada a precipitação do enxofre na forma de sulfato de bário, com solução de cloreto de bário 100 g L-1, e posterior filtragem à vácuo do precipitado, à fim de verificar a massa obtida. A amostra de fertilizante foi diluída, e o enxofre determinado em um ICP OES com nebulizador pneumático. Na turbidimetria, foi precipitado sulfato de bário por uma solução de cloreto de bário 5% m/v e foi detectada a turbidez da mistura em um espectrofotômetro de absorção molecular no UV-Visível. A extração em meio alcalino não foi satisfatória para métodos espectrométricos, devido ao alto efeito de matriz gerado no ICP OES e, da capacidade de limitar a formação do precipitado de sulfato de bário na turbidimetria. Dos métodos estudados...

Efeitos da adição de N2 ao gás nebulizador em ICP OES com configuração axial

Cerveira, Camila; Scheffler, Guilherme Luiz; Pozebon, Dirce
Fonte: Universidade Federal do Rio Grande do Sul Publicador: Universidade Federal do Rio Grande do Sul
Tipo: Conferência ou Objeto de Conferência Formato: application/pdf
POR
Relevância na Pesquisa
16.72%

Uso de nitrogênio em nebulizador de alta eficiência para introdução de soluções no plasma indutivamente acoplado

Velho, Arthur Cavada de Campos
Fonte: Universidade Federal do Rio Grande do Sul Publicador: Universidade Federal do Rio Grande do Sul
Tipo: Conferência ou Objeto de Conferência Formato: application/pdf
POR
Relevância na Pesquisa
16.72%

Emprego de nebulizador pneumático de ICP-MS como câmara de diluição em sistemas de injeção em fluxo para determinações multielementares

Gomes Neto, José Anchieta; Silva, José Bento B.; Rodrigues Neto, Renato; Curtius, Adilson José; Souza, Ivan G.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: 405-409
POR
Relevância na Pesquisa
16.72%
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq); Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES); An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.

Avaliação de aspectos configuracionais e analiticos da tecnica TSFFAAS; Evaluation of configurational and analytical aspects of the TSFFAAS technique

Marcel Luis Brancalion
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 15/12/2006 PT
Relevância na Pesquisa
16.72%
Nesta Dissertação foi avaliado o mecanismo de formação do spray térmico na técnica TSFFAAS (Thermospray Flame Furnace Atomic Absorption Spectrometry) via filmagens com altas velocidades de aquisição, relacionando estes aspectos com os resultados analíticos obtidos para o elemento Cd. Para isso foram utilizadas uma câmera com arranjos CCD operando à velocidade de 1000 qps (1/1000 s) e outra com sensores CMOS à taxa de até 18000 qps (1/18000 s), observando pela primeira vez que o mecanismo de formação do spray é bastante distinto daqueles já descritos na literatura. Operando em baixa pressão de bombeamento (ca. 0,15 MPa), os efeitos térmicos se sobressaem à componente mecânica (propulsão) na formação do spray térmico, de modo que o mesmo se apresenta na forma de pequenos jatos sendo ejetados pelo capilar cerâmico (320 ± 50 pulsos/s e velocidades ca. 40 km h), em meio a uma grande fase gasosa, resultado da alta eficiência de vaporização, bem como do efeito de Leidenfrost. Os aspectos configuracionais foram utilizados de maneira satisfatória para explicar os resultados analíticos obtidos mediante a avaliação dos diversos parâmetros que regem a técnica, baseadas na determinação de Cd. Foram otimizadas as variáveis físicas: vazão da solução carregadora (0...

Emprego da técnica MF-HG-AAS na determinação de estanho : análise de parâmetros analíticos e morfológicos do atomizador metálico; Employment of a metallic furnace hydride generation atomic absorption spectrometry (MF-HG-AAS) method for tin determination : analytical and morphological parameters analysis of metallic atomizer

Rodrigo Moretto Galazzi
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 20/02/2013 PT
Relevância na Pesquisa
16.72%
Nessa dissertação, otimizou-se um método para a determinação de estanho (Sn) em amostras biológicas empregando a técnica de Espectrometria de Absorção Atômica por Geração de Hidretos e Forno Metálico (MF-HG-AAS, do inglês Metallic Furnace Hydride Generation Atomic Absorption Spectrometry). Foram avaliadas algumas variáveis químicas como o tipo e concentração do carregador/diluente da solução padrão, concentração do redutor tetraidridoborato (-1) de sódio (THB) e concentração de hidróxido de sódio, bem como variáveis físicas do sistema dentre elas a vazão de carregador, proporção de acetileno:ar na chama, volume de solução injetado, vazão de argônio como gás de arraste, vazão de água no nebulizador e área total de furos no tubo metalico Inconel600®. Foi realizado um estudo do efeito de memória observado em condições de chama oxidante nas vazões de 1,5:9; 1,4:9; 1,3:9; 1,4:10; 1,4:8 e 1,5:11 L min de acetileno:ar, respectivamente. Em todas essas proporções de chama diferentes da otimizada (1,5:10 L min acetileno:ar) há efeito de memória, o que é extremamente indesejável. Após a otimização do sistema, foram realizados testes de exatidão e precisão do mesmo com os materiais PACS-2 (sedimento) e SRM 1643e (amostra de água) em que...

Determinação de elementos traço em amostras de águas do mar, sedimento, mexilhões e ostras, da região costeira da Ilha de Santa Catarina, SC, Brasil, por espectrometria de massa com fonte de plasma indutivamente acoplado

Seibert, Edson Luiz
Fonte: Florianópolis, SC Publicador: Florianópolis, SC
Tipo: Tese de Doutorado Formato: xiii, 149 f.| il., tabs., grafs.
POR
Relevância na Pesquisa
16.72%
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química.; Moluscos bivalves são freqüentemente utilizados como indicadores para análises de contaminação aquática representando a base de inúmeros programas de monitorização ambiental. Com a perspectiva de se avaliar riscos potenciais à saúde humana, este trabalho investigou a qualidade de mexilhões Perna perna e ostras Crassosstrea gigas cultivadas em zonas costeiras da Ilha de Santa Catarina ao longo dos anos de 1999 e 2000, quanto ao teor de elementos traço. Três pontos de coleta foram selecionados: Enseada da Pinheira, Praia do Ribeirão da Ilha e Praia de Sambaqui. Parâmetros físico-químicos da água do mar considerados relevantes na medida do grau de eutrofização mostraram valores compatíveis com a dinâmica do meio ambiente estudado. Concentrações de elementos metálicos e semi-metálicos foram determinadas na água do mar, nas fases dissolvida e particulada, nos tecidos dos bivalves e no sedimento. As concentrações foram similares ou menores do que aquelas encontradas em outros países. Também foram determinadas as concentrações dos elementos traço nos sedimentos coletados nas regiões de cultivo...

Síntese e caracterização de fotocatalisadores aplicados a desinfecção do ar de ambientes internos climatizados

Moreira, Isabel Medeiros
Fonte: Florianópolis, SC Publicador: Florianópolis, SC
Tipo: Dissertação de Mestrado Formato: 140 p.| il., grafs., tabs.
POR
Relevância na Pesquisa
16.72%
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2011; A poluição do ar em ambientes internos deve-se à presença de diferentes tipos de poluentes. Entre as diversas técnicas de tratamento do ar interno destaca-se a oxidação fotocatalítica. A oxidação fotocatalítica trata-se de um processo oxidativo avançado, caracterizando-se pela oxidação via radicais livres, como o radical hidroxila, que transforma os compostos poluentes em espécies químicas inócuas (geralmente dióxido de carbono e água). Este trabalho propôs-se a preparar e caracterizar fotocatalisadores e aplicá-los como uma alternativa para o tratamento de contaminantes presentes em ambientes internos, tais como as bactérias. Os fotocatalisadores foram sintetizados pelo método de Sol/Gel e depositados em filtros de fibra de vidro. Os fotocatalisadores foram caracterizados pela técnica de Microscopia Eletrônica de Varredura (MEV), Espectroscopia de Energia Dispersiva (EDS) e Difratometria de Raios-X (DRX). Entre os resultados obtidos nos testes de caracterização o fotocatalisador sintetizado com concentração de 0,4 M de TiO2 e pelo Método de Deposição e Calcinação 1...

Qual dispositivo utilizar no tratamento da crise de sibilância em crianças? Nebulizador ou inalador dosimetrado?

Rodrigues,Joaquim Carlos
Fonte: Sociedade Brasileira de Pediatria Publicador: Sociedade Brasileira de Pediatria
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/10/2003 PT
Relevância na Pesquisa
16.72%

Emprego de nebulizador pneumático de ICP-MS como câmara de diluição em sistemas de injeção em fluxo para determinações multielementares

Gomes Neto,José Anchieta; Silva,José Bento B.; Rodrigues Neto,Renato; Curtius,Adilson José; Souza,Ivan G.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/07/1998 PT
Relevância na Pesquisa
16.72%
An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.

Conhecimentos de pais de crianças asmáticas sobre a doença no momento da admissão a um serviço especializado

Zhang,Linjie; Costa,Marilice G.; Ávila,Laila H.; Bonfanti,Thiago; Ferruzzi,Emerson H.
Fonte: Associação Médica Brasileira Publicador: Associação Médica Brasileira
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2005 PT
Relevância na Pesquisa
16.72%
OBJETIVO: Avaliar conhecimentos de pais de crianças asmáticas sobre a doença no momento da admissão a um serviço especializado. MÉTODOS: O presente trabalho foi um estudo descritivo. Foram entrevistados os pais de 93 crianças asmáticas com idade entre 29 dias e 18 anos, no momento da admissão ao ambulatório de Pneumologia Pediátrica de um hospital universitário, por meio de um questionário para avaliar os conhecimentos deles sobre asma. As avaliações concentraram-se no entendimento da natureza, do prognóstico e do tratamento da asma. Foram analisados somente os dados obtidos em pais de 87 crianças com idade entre 29 dias e 10 anos. RESULTADOS: Na auto-avaliação, 93,1% dos pais consideraram seus conhecimentos sobre asma insuficientes; e 88,5% demonstraram interesse em adquirir mais informações. Na avaliação específica de conhecimentos sobre natureza, prognóstico e tratamento da asma, 96,6% dos pais não sabiam o papel da inflamação das vias aéreas na síntese dos sintomas da doença; e 51,7% acreditavam na cura desta doença; entre os pais cujos filhos usavam nebulizador domiciliar, 80,6% costumavam cometer erros na sua aplicação; e todos os pais cujos filhos usavam inalador pressurizado sem espaçador não conheciam a técnica inalatória correta; 65...

Respostas fisiológicas e produtivas de vacas holandesas em lactação submetidas a diferentes ambientes

Martello,Luciane Silva; Savastano Júnior,Holmer; Silva,Saulo da Luz e; Titto,Evaldo Antonio Lencioni
Fonte: Sociedade Brasileira de Zootecnia Publicador: Sociedade Brasileira de Zootecnia
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/02/2004 PT
Relevância na Pesquisa
16.72%
Este trabalho foi realizado, no verão de 2002, com o objetivo de avaliar a influência de alguns recursos de climatização na produção de leite e na termorregulação dos animais. Foram utilizadas 10 primíparas e 17 multíparas em lactação, distribuídas em instalação controle (ICO), instalação com nebulizador associado a ventiladores (ICL) e instalação com tela de sombreamento (IT). A produção de leite e o consumo individual foram medidos diariamente para cada animal. A temperatura retal foi medida três vezes ao dia, em três animais de cada instalação; a temperatura de superfície da pele, três vezes ao dia em todos os animais; e a freqüência respiratória, duas vezes ao dia em todos os animais. Os dados climáticos de cada instalação foram registrados e posteriormente calculados os índices de temperatura e umidade (ITU) e de globo negro e umidade (ITGU). Foram selecionados e analisados 26 dias com entalpia elevada. O ITU entre 75 e 76, apesar de considerado estressante por diversas fontes da literatura, não foi associado à condição de estresse pelos animais. As multíparas da instalação climatizada apresentaram freqüência respiratória e temperatura de pele significativamente menor em relação às multíparas das demais instalações. As primíparas apresentaram freqüências respiratórias e temperaturas retais mais altas que as multíparas...

Avaliação da hiperresponsividade brônquica à solução salina hipertônica em crianças e adolescentes

Kussek,Paulo; Rosario Filho,Nelson Augusto; Cat,Mônica
Fonte: Sociedade Brasileira de Pneumologia e Tisiologia Publicador: Sociedade Brasileira de Pneumologia e Tisiologia
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2006 PT
Relevância na Pesquisa
16.72%
OBJETIVO: Avaliar a hiperresponsividade brônquica à solução salina hipertônica a 4,5% como método alternativo a outros agentes broncoconstritores e sua relação com a sensibilização alérgica do paciente. MÉTODOS: Estudo transversal, experimental, com 85 indivíduos assim distribuídos: 45 no grupo de asmáticos e 17 no grupo controle não asmáticos e não alérgicos, que completaram o teste. Para nebulizar a solução salina hipertônica foi utilizado um nebulizador ultra-sônico de grande volume, sucessivamente durante 0,5, 1, 2, 4 e 8 minutos até haver queda > 15% em relação ao volume expiratório forçado no primeiro segundo basal. A dosagem de imunoglobulina E específica ao Dermatophagoides pteronyssinus por ImmunoCap foi considerada positiva quando > 0,35 kU/L. RESULTADOS: No grupo de asmáticos, 36 apresentaram queda média do volume expiratório forçado no primeiro segundo de 27,4% após nebulização de solução salina hipertônica. Nenhum do grupo controle (imunoglobulina E < 0,35 kU/L) apresentou resposta à solução salina hipertônica e a queda média do volume expiratório forçado no primeiro segundo foi de 9%. Nove asmáticos tiveram provocação brônquica negativa. A freqüência de provocação brônquica positiva foi maior nos indivíduos com imunoglobulina E específica elevada...

Nebulizadores: fonte de contaminação bacteriana em pacientes com fibrose cística?

Brzezinski,Lorena Xavier Costa; Riedi,Carlos Antônio; Kussek,Paulo; Souza,Helena Homem de Melo de; Rosário,Nelson
Fonte: Sociedade Brasileira de Pneumologia e Tisiologia Publicador: Sociedade Brasileira de Pneumologia e Tisiologia
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2011 PT
Relevância na Pesquisa
16.72%
OBJETIVO: Determinar se os nebulizadores de pacientes com fibrose cística são fonte de contaminação microbiana e verificar se a técnica e a frequência de desinfecção dos nebulizadores é apropriada. MÉTODOS: Estudo de corte transversal observacional, sem grupo controle. Foram coletadas amostras de 28 pacientes com fibrose cística, no domicílio do paciente, sem aviso prévio sobre o motivo da visita. Foram colhidas três amostras por paciente: do reservatório do nebulizador, da máscara/bocal e do próprio paciente (swab da orofaringe/escarro). As amostras foram acondicionadas adequadamente e levadas para análise. Os pacientes, seus pais ou responsáveis preencheram um questionário sobre métodos de limpeza e desinfecção dos nebulizadores. RESULTADOS: Foram obtidas 84 amostras dos 28 pacientes. Destes, 15 (53,5%) eram do gênero masculino. A mediana de idade foi de 11 anos (variação: 1-27 anos). Dos 28 pacientes, 15 apresentaram culturas de escarro/orofaringe positivas. As bactérias encontradas com maior frequencia foram Streptococcus aureus (8/15) e Pseudomonas aeruginosa (4/15). A cultura obtida dos nebulizadores identificou diversos patógenos, sem nenhum predominante. Não houve associações entre os resultados das culturas obtidas dos nebulizadores e aquelas dos pacientes em 27 casos (96...

Nebulização a jato associada à ventilação não-invasiva : análise cintilográfica da ventilação pulmonar pela deposição do radioaerossol

Érico Tenório de França, Eduardo; de Fátima Dornelas de Andrade, Armele (Orientador)
Fonte: Universidade Federal de Pernambuco Publicador: Universidade Federal de Pernambuco
Tipo: Outros
PT_BR
Relevância na Pesquisa
16.72%
A nebulização é rotineiramente usada em situações de emergência para administração de fármacos (broncodilatadores e corticóides). A associação da nebulização com a ventilação não-invasiva (VNI) visa otimizar essa terapêutica. O objetivo deste estudo foi analisar a ventilação pulmonar regional durante a associação da nebulização com a VNI com dois níveis de pressão positiva (binível), através da cintilografia pulmonar, analisar a taxa de depuração pulmonar e ainda a correlação da deposição pulmonar com o fluxo inspiratório e o volume corrente. Foram estudados 13 voluntários, com idade de 23,30 ± 1,49 anos, sem história de doença respiratória e com valores espirométricos normais. O estudo foi realizado em duas fases: com a nebulização em respiração espontânea (RE) e outra fase associada à VNI com IPAP (12 cmH2O) e EPAP (5 cmH2O). O radioaerossol foi gerado durante 9min por um nebulizador a jato, contendo tecnécio (Tc 99m) associado ao DTPA. A cada 3min foram monitorizados: FC, FR, SO2, VC, VM e do fluxo inspiratório. Após a inalação, os voluntários permaneciam na câmara de cintilação para obtenção das imagens, nos tempos (0, 15, 30, 45 e 60) minutos. Foram delimitadas as regiões de interesse (ROIs) que foram analisadas no gradiente vertical e horizontal. Para análise estatística foram usadas Análise da Variância com medidas repetidas...

Desenvolvimento de mátodos espectroanalíticos para a determinação de polifenóis totais e elementos minerais em vinhos

Andrade, Marcelo Farias de; Paim, Ana Paula Silveira (Orientadora); Sanz, Maria Luisa Cervera (Coorientadora)
Fonte: Universidade Federal de Pernambuco Publicador: Universidade Federal de Pernambuco
Tipo: Tese de Doutorado
BR
Relevância na Pesquisa
16.72%
O vinho é constituído por sais minerais, vitaminas, polifenóis e diversos outros nutrientes que o faz ser uma bebida benéfica à saúde. De acordo com as técnicas de vinificação empregadas, bem como as peculiaridades inerentes ao ambiente de plantio, o vinho pode adquirir características que o tornem único daquela região, tornando-o capaz de receber uma Denominação de Origem (D.O.). Objetivando-se caracterizar e fornecer dados para se contribuir com a D.O. foram desenvolvidos métodos de análise espectroanalíticas para determinação de polifenóis totais e minerais, os quais foram aplicados em amostras de Vinhos do Vale do São Francisco (VSF) e de outras regiões para efeito de comparação. No primeiro capítulo, foi desenvolvida uma metodologia de análise em fluxo com minibombas solenóide, com o intuito de caracterizar vinhos com relação ao seu teor de polifenóis totais. Para tanto, se oxida os compostos polifenólicos nas amostras com o uso de hipoclorito proveniente de água sanitária comercial e, posteriormente, detecta-se a quimiluminescência gerada pela reação entre luminol e o excesso de hipoclorito, por meio de um luminômetro lab-made. Após a otimização de variáveis e validação da metodologia proposta...

Análisis multielemental secuencial de aleaciones mediante plasma de argón generado por acoplamiento inductivo de radiofrecuencia; Multielement sequential analysis of alloys by radiofrequency inductively coupled argon plasma

Farías de Funes, Silvia
Fonte: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires Publicador: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires
Tipo: info:eu-repo/semantics/doctoralThesis; tesis doctoral; info:eu-repo/semantics/publishedVersion Formato: application/pdf
Publicado em //1996 SPA
Relevância na Pesquisa
16.72%
En el presente trabajo se describe la caracterización espectroscópica y analítica de un espectrómetro óptico constituido por el acoplamiento de una fuente de plasma inductivo de argón (IPC) y un monocromador programable de alta resolución, aplicable a la determinación secuencial de Mg, Mn, Cr, Mo en aleaciones de aluminio y de base Cu-Ni. Después de una discusión general sobre las características fundamentales del dispositivo instrumental empleado, se consideran aspectos básicos relacionados con al medición experimental del poder de resolución práctico del monocromador programable, controlado por computadora. Utilizando fuentes de líneas atómicas angostas (lámparas de cátodo hueco), se determinó la variación del ancho de banda espectral en función del ancho de ranura para diferentes regiones de longitud de onda, lo que permitió establecer la capacidad del sistema para la resolución de espectros complejos. Utilizando un modelo simple de convolución cuadrática, se evaluó un término que representa la contribución de efectos de aberración óptica. Pudo demostrarse que es posible obtener valores de resolución del orden de 5 pm utilizando ranuras angostas de altura reducida. La caracterización espectroscópica de la fuente se basó en la medición de parámetros fundamentales de la descarga en condiciones de operación analítica...

Análisis multielemental secuencial de aleaciones mediante plasma de argón generado por acoplamiento inductivo de radiofrecuencia; Multielement sequential analysis of alloys by radiofrequency inductively coupled argon plasma

Farías de Funes, Silvia
Fonte: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires Publicador: Facultad de Ciencias Exactas y Naturales. Universidad de Buenos Aires
Tipo: Tesis Doctoral Formato: text; pdf
Publicado em //1996 ESPAñOL
Relevância na Pesquisa
16.72%
En el presente trabajo se describe la caracterización espectroscópica y analítica de un espectrómetro óptico constituido por el acoplamiento de una fuente de plasma inductivo de argón (IPC) y un monocromador programable de alta resolución, aplicable a la determinación secuencial de Mg, Mn, Cr, Mo en aleaciones de aluminio y de base Cu-Ni. Después de una discusión general sobre las características fundamentales del dispositivo instrumental empleado, se consideran aspectos básicos relacionados con al medición experimental del poder de resolución práctico del monocromador programable, controlado por computadora. Utilizando fuentes de líneas atómicas angostas (lámparas de cátodo hueco), se determinó la variación del ancho de banda espectral en función del ancho de ranura para diferentes regiones de longitud de onda, lo que permitió establecer la capacidad del sistema para la resolución de espectros complejos. Utilizando un modelo simple de convolución cuadrática, se evaluó un término que representa la contribución de efectos de aberración óptica. Pudo demostrarse que es posible obtener valores de resolución del orden de 5 pm utilizando ranuras angostas de altura reducida. La caracterización espectroscópica de la fuente se basó en la medición de parámetros fundamentales de la descarga en condiciones de operación analítica...